Tender For Supply Installation Testing and Commissioning of Dc Fast Charging Stations For Ev Passenger Coaches At Cochin International Airport.
Tender Value
31.77 Lakhs
Estimated cost
Bid Submission
09 Sep 2026
17 days left
EMD
80000
Bank guarantee accepted
Document Fee
2360
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ernakulam → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supply Installation Testing and Commissioning of Dc Fast Charging Stations For Ev Passenger Coaches At Cochin International Airport.
BOQ
| Sl. No. | Item Description |
| 1 | DC Fast charger |
| 2 | Supply of DC Fast charger of min 240kW capacity dual gun CCS2 type • The charger shall be a 240kW DC fast charger suitable for electric bus charging at an airport apron.• It must support CCS2 protocol and comply with IS 17017/IEC 61851.• The charger should provide full 240kW output when a single gun is operating and support dynamic power sharing in dual-gun mode.• It should be ARAI-approved and comply with BIS/Indian EV charger standards. Input Requirement1.Input Voltage: 380-415V AC, 3-phase2.Input Frequency: 50 Hz3.Power Factor: >0.98 for load 50-100%4.THDi: <5% at full load5.Efficiency: ≥93%6. Input Supply Failure back-up: Battery backup for minimum 1 hour for the control System and billing unit. Data logs should be synchronized with CMS during back up time, in case battery drains out.8.Cable Length: Minimum usable length 5 meters9.Warranty : 2 YearsOutput RequirementsMaximum Power Output: 240kW,DC Output Voltage Range: 200-1000V,Max Current per Gun: Minimum 250A Continious,No. of Charging Guns: 2 (CCS2 connectors)Dynamic Power Sharing: Yes (240kW in single gun mode, 120kW per gun in dual mode)Mechanical & Environmental Specifications,IP Rating: Minimum IP54 for outdoor installation,Cooling System: Forced air cooling,Operating Temperature: -10°C to +55°C ,Installation Type: Floor-mounted, free-standingUser Interface & CommunicationDisplay: Minimum 9” TFT LCD touchscreen,Connectivity: Ethernet, 4G LTE, Wi-Fi, Protocol Support: OCPP 2.0.1 minimum or higher,Remote Monitoring & Diagnostics: SupportedProtection & Safety FeaturesOvercurrent, overvoltage, undervoltage protection ,Short circuit, earth leakage, and insulation resistance monitoring, Emergency stop button, Surge protection and residual current detection.Compliance with IS 17017 & IEC safety standardsCertification & ComplianceARAI-certified for 240kW fast charger,BIS certification,Safety standards compliance (IEC 61851/IS17017),ISO 15118 Preferable |
| 3 | Installation, Testing and Commissioning of EV Charger: Installation, testing and commissioning of the EV charger, including providing and fixing a suitable MS base/support, all necessary components, auxiliaries, accessories and complete documentation. The scope shall also include glanding and termination of the incoming power cable and earthing conductor from the LT panel at the EV charger, including all required glands, lugs, hardware and accessories, ensuring proper connectivity and satisfactory operation of the complete system in accordance with applicable standards and OEM recommendations. |
| 4 | Charge Point Operator (CPO) System – Platform for managing two EV chargers with remote monitoring, user authentication (password/RFID/OTP login), real-time diagnostics, automated billing (monthly invoice generation), consumption-based reporting, mobile/web app access, and integration with Central Management System (CMS) (OCPP 2.0.1 or higher/latest supported version.). Includes CMS/CPO subscription or licence charges, cloud hosting, software/firmware updates, data storage, cybersecurity updates, technical support and associated services for a period of seven (7) years, without additional cost to CIAL.The CPOs shall have all the features as specified in the technical specifications and as directed by Engineer in charge. |
| 5 | Annual Maintenance Charges:Annual Maintenance Charges:The AMC for the EV chargers shall commence after completion of the two-year Defects Liability Period (DLP) and shall be carried out in accordance with the Technical Specifications and prescribed maintenance requirements.His includes software/firmware updates and upgrades, technical support, and other maintenance-related services required for satisfactory operation of the EV chargers during the AMC period. |
| 6 | For 1st year |
| 7 | For 2nd year |
| 8 | For 3rd year |
| 9 | For 4th year |
| 10 | For 5th year Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysSep 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender