Tender For Survey Design Engineering Manufacture Supply Installation Testing Commissioning Of New Car Parking Structure With Grid Connected Solar Pv Power Plant Of Cumulative Capacity 50Kw Including 5 Years Comprehensive Operation Maintenance At Spas
Tender Overview
Project Description
Tender for Survey Design Engineering Manufacture Supply Installation Testing Commissioning Of New Car Parking Structure With Grid Connected Solar Pv Power Plant Of Cumulative Capacity 50Kw Including 5 Years Comprehensive Operation Maintenance At Spas Bldg In G.U. C Us
BOQ
| Sl. No. | Item Description |
| 1 | Supplying, installing, testing and commissioning of 50 kWp ON-GRID Solar pV System / Plant consisting Solar PV Poly Crystalline Panel and Solar ON-GRID Inverter of similar capacity (THD<3%) with interconnecting wires / cables up to solar ON GRID inverter, proper base plate, canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB ,MCB etc. wiring up to solar Inverter in casing and capping, display board, sign board, two distinct earthing, lightning arrester, liasoning charges, remote monitoring system with maintaining card / chip for 5 years including net chargesfor RMS System, complete upto net meter Installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract |
| 2 | Supplying, installing, testing and commissioning AC three phase LT four wire CT Embedded Net Meter of Current Capacity 40-200 AMPS and Voltage 3x240 Volts Ph-N as per the technical specifications given in MSEDCL order no. CE/QC-T/MSCII/Net 40-200 A Date 03.02.2021 + MCCB Charges with Box |
| 3 | Supplying, installing, testing and commissioning AC three phase LT four wire CT Embedded Energy Meter of Current Capacity 40-200 AMPS and Voltage 3x240 Volts Ph-N as per the technical specifications given in MSEDCL order no. CE/QC-T/MSCII/Net 40-200 A Date 03.02.2021 + MCCB Charges with Box |
| 4 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double all corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 5 | Providing and fixing board displaying information, such as 'Name of work, Tender cost, Name of Contractor, Work completion and liability period etc', having rectangular shape of 1.20mx0.90m size made out 18gauge(1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border/messages/symbols etc. with approved colour shade paint complete, on M.S.angle of size35x35x3mm frame with properly cross braced M.S. angles of size35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65mmx65 mmx 6mm, 3.65m long painted with alternate black and white bands of 25 cm width including all fixtures etc. and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75cm including, excavation, refilling, transportation, and labor etc complete. Spec.Number As directed by Engineer in Charge |
| 6 | Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. 3 1/2 Core 70 sq.mm |
| 7 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 400 sq.mm in the existing masonry open duct, etc. complete as required |
| 8 | Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.(4) 3 1/2 x 70 Sq. mm. |
| 9 | Design, fabrication, supply and erection of the Solar panel mounting car port structure, Hot-dip galvanized steel with 80 micron with withstand the basic wind speed of 180 kmph with T2 or T1 condition. SS304/SS316 Fasteners with at least 700MPa UTS or equivalent to 8.8 grade fasteners with specialized coatings. For gutters epoxy based long lasting coating. The parking size and vehicular movement as per IRC:SP:12-2015 (As per the guidelines for parking facilities in urban area) j. The structure according to withstand wind loads as per IS875 part 3-2015 and deflections as per IS800. The mounting structure steel as per latest IS 2062: 1992 and galvanization of the mounting structure as per IS 4759 compliance. The civil structures shall be according to the load bearing capacity of the land. |
| 10 | Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878/15683 complete erected with necessary clamp made from 50x 6 mm. M. S. flat with nut & bolts grouted in wall complete. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender