Public Administrative Department Government Departments Closing in 4 days TDR #57089930

Tender For Providing Of Fire Alarm System, Fire Extinguishers, Emergency Lighting System, Public Address System And Rccb At Phc Tugapur Under Nacd, Apwd, Mayabunder.

Issued by Government Departments · North and Middle Andaman, Andaman And Nicobar Islands
Tender Value
7.13 Lakhs
Estimated cost
Bid Submission
28 Aug 2026
4 days left
EMD
14273
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
North and Middle Andaman → Andaman And Nicobar Islands
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Providing Of Fire Alarm System, Fire Extinguishers, Emergency Lighting System, Public Address System And Rccb At Phc Tugapur Under Nacd, Apwd, Mayabunder.

BOQ

Name of Work:- Providing of Fire Alarm System, Fire extinguishers, Emergency Lighting System, Public Address System and RCCB at PHC Tugapur under NACD, APWD, Mayabunder.
Sl. No. Item Description
1Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
23 x 2.5 sq. mm
3Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
420 mm
5Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
6Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
7Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
86 way , Double door
9Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
10Single pole
11Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
12Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
13Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.
14speaker cable Single pair, 2-core, 1.5 sqmm
15Supplying, installation. testing and commissioning of microprocessor based intelligent Addressable Main Fire alarm Four Loop Panel (without loop card), central processing unit capable of supporting 4 Loop Card circuits, inbuilt RS-485 Networking Circuit for peer to peer networking. LCD character display with touch screen or other keypad, events history log storage facility, power supply unit (230±5% V. 50 hz) and provision for battery backup 24V DC with built-in-charger. complete as required including necessary programming and configuration. Make: Ravel. Model No. Avani or its equivalent.
16Supplying, installation, testing & commissioning of Loop Card plugged into slot provided in the motherboard of Main Fire Alarm panel. which is capable of supporting both Class A and Class B SLC wiring of addressable Detectors, Manual Call Points. Modules etc. in any combination per loop, complete as required. Make: Ravel, Model No. RE-LC or its equivalent.
17Supplying, installation, testing & commissioning of Analogue Addressable photoelectric smoke Detector with base complete with all connections etc. as required. Make: Ravel, model No.RE 317D-SL or its equivelent.
18Supplying, installation, testing & commissioning of Analogue Addressable Heat Detector with base complete with all connections etc. as required. Make: Ravel, 317D-HL or its equivalent.
19Supplying, installation, testing & commissioning of Analogue Addressable Manual Call Point complete with mounting box, all connections etc. as required. Make: Ravel, Model No. RE-717M or its equivalent.
20Supplying installation, testing & commisssioning of Conventional Sounder cum Strobe 24VDC operated complete with all connections, etc. as required, mounted on wall/wood panel/true ceiling/false ceiling. Make: Ravel, Model No. RE-24SS or its equivalent.
21Supplying and fixing of 12 volt. 07 AH sealed maintenance free battery in Fire Alarm Panel as standby power source. Make. Exide or its equivalent.
22Supplying, installation, testing & commissioning of Addressable Isolator Module complete as required. Make Ravel, Model No. RE- 717Ml or its equivalent.
23Supplying and fixing of PVC mounting box 4x4 on surface/recess for smoke detectors, modules, etc. as required.
24Supplying and fixing of ABC powder stored pressure type fire extinguisher 09 Kg capacity (ISI Marked conforming to 15:15683) squeeze grip type with discharge hose & nozzle complete with initial charge wall bracket fixing with suitable screws etc. as required. Make: EcoFire or its equivalent
25Supplying and fixing of Mechanical Foam stored pressure type fire extinguisher 09 Ltr capacity (ISI Marked conforming to IS:15583) squeeze grip type with discharge hose & nozzle complete with initial charge, wall bracket fixing with suitable screws etc. as required. Make: EcoFire or its equivalent.
26Supplying of Fire Bucket Stand (for 4 buckets) made of MS with canopy of size 3 ft x 2 ft galvanized sheet. Stand height 3.5 ft and wide 3 ft red colored conforming to 1S:2546
27Supplying of Fire bucket made from 24 SWG GI sheet red coloured 9 Ltr with hanging handle conforming to 1S:2546.
28Supplying, installation, testing & commissioning of Emergency Exit Light (Double high glow LED based beam & Exit sign) operating on 220V 50Hz power supply having minimum 2 hours back-up with 12V maintenance free batteries for wall/ceiling mounting with suspension mounting kit and battery charger etc. complete as required. Make: Qutak, Model: QT-EL3250 or its equivalent.
29Supplying, installation, testing & commissioning of Exit Light (Double sided Laser LED light) operating on 220V 50Hz power supply having back-up with 6V maintenance free batteries for wall/ceiling mounting with suspension / 2 mounting kit and battery charger etc. complete as required. Make: Qutak, Model: QT-LT17500 or its equivalent.
30Supply and fixing of Wall mount Network Rack-Standard 19 rack x 6U, made of CRCA sheet with toughened glass door, lock & key arrangement for mounting PA system accessories including connections, etc. as required.
31Supplying, installation, testing & commissioning of 2 zone PA Amplifier (60+60Watts) with 5 Mics & 2 Aux inputs and AC/DC operation complete as required. Make: Ahuja. Model: TZA-1200 or its equivalent.
32Supplying, installation, testing & commissioning of Paging wired microphone fitted with flexible 12 inch gooseneck and high quality unidirectional dynamic cartridge i/c 6 mtr twin core shielded low noise cable complete as required. Make: Ahuja. Model: ACM96 or its equivalent.
33Supplying, installation, testing & commissioning of 6 inch full range 6W/100V wall speakers mounted on wall complete with connections, etc. as required. Make: Ahuja. Model: W5661T or its equivalent Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57089930
AUTHORITY Government Departments
TENDER VALUE 7.13 Lakhs
LAST DATE 28-08-2026
Authority
Authority Name Andaman Public Works Dept
Work Description Tender for Providing Of Fire Alarm System, Fire Extinguishers, Emergency Lighting System, Public Address System And Rccb At Phc Tugapur Under Nacd, Apwd, Mayabunder.
Basic Detail
Tender No NIT No. 90/2026-27/EE/NACD
Bidding Type Tender
Location
City North and Middle Andaman
State Andaman And Nicobar Islands
Key Dates
Publish Date 19 Aug 2026
Submission Date 28 Aug 2026
Open Date 28 Aug 2026
Finance
Tender Value 7.13 Lakhs
Tender Fee Ref. Documents
EMD 14273
Exemption Not Available
Document List
0bed56ab-2176-411b-b2e6-fa9f177fdc6c.html
BOQ_25739.xls
Tenderdocument.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Aug 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

0bed56ab-2176-411b-b2e6-fa9f177fdc6c.html

xls

BOQ_25739.xls

pdf

Tenderdocument.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders