Tender For Upgradation/Strengthening Of Infrastructure By Way Of Macdamization, Face-Lifting, Ele!Unexpected End Of Formulactrical Infrastructure, And Access Control & Security System At District Industries Centre Srinagar.
Tender Overview
Project Description
Tender For Upgradation/Strengthening Of Infrastructure By Way Of Macdamization, Face-Lifting, Ele!Unexpected End Of Formulactrical Infrastructure, And Access Control & Security System At District Industries Centre Srinagar.
BOQ
| Sl. No. | Item Description |
| 1 | Providing and Fixing of Wiring of Lighting Point/Bell Point/Exhaust fan Points in 2x1.5 Sq. mm FR PVC Insulated Multistrand Copper wire of ISI Marked including 6 Amp Switch |
| 2 | Providing and Fixing of Wiring for heating Points in 2x4 Sq. mm + 1x2.5 sqmm FR copper wire Multistrand of ISI Mark including 16-20 Amp switch socket with connection |
| 3 | Providing and Fixing of Wiring for Computer Point in 2x2.S Sq. mm + 1x1.5 FR PVC Insulated Multistrand Copper wire of ISI Mark including 5 Amp 3 Nos of socket with connection |
| 4 | Supply and Fixing of 1200 mm Sweep Celling Fan OF ISI Mark Complete With Necessary Connections. Complete Job |
| 5 | Providing and Fixing of Wiring of fan Points in 2x1.5 Sq. mm FR PVC Insulated Multistrand Copper wire of ISI Marked including 6 Amp Switch including 6 Amp fan regulator complete connections as required |
| 6 | Supply and Fixing of 200 mm Exhaust Fan Shutter Type Of ISI Mark Complete With Necessary Connections Complete Job |
| 7 | Supply and Fixing of Surface/recess 12/15 watt LED light including connection Complete job |
| 8 | Providing & Fixing of Double Door Distribution board TPN 8 way of ISI Mark Recessed In Walls including Refacing of Walls. Complete Job |
| 9 | Providing & Fixing of Double Door Distribution board TPN 4 way of ISI Mark Recessed In Walls including Refacing of Walls. Complete Job |
| 10 | Supply and fixing of 6-32 amp Single pole MCB OF ISI Mark With necessary Connections. |
| 11 | Supply and fixing of 63 amp DP MCB ISI make with necessary Connections |
| 12 | Supply and fixing of Main Service Line in 95 Sq. mm 3.5.Core Aluminum armed Cable of ISI Mark. |
| 13 | Chemical Earthing |
| 14 | Sub Main for heating lighting computer points: a) Providing & fixing of single core 10 sq.mm Multi stand 4x10 sqmm + 1x6 sqmm copper wire FR of ISI Mark Laid in PVC Conduit |
| 15 | b) Providing & fixing of single core 6 sq.mm Multi stand 4x6 sqmm + 1x2.5 sqmm copper wire FR of ISI Mark Laid in PVC Conduit |
| 16 | c) Providing & fixing of single core 2.5 sq.mm Multi stand 4x4 sqmm + 1x2.5 sqmm copper wire FR of ISI Mark Laid in PVC Conduit |
| 17 | Supply, installation and commissioning of Main Control Panel board 415 Volt Duly maid of 16 SWG Protected and Vermin proof with Gas kit led Lockable doors complete with inner connections crimping legs bounding to earth terminals with following Controlling EquipmentIncomer:250 AMP MCCB 4P300 AMP BUSBAROutgoing:100 AMP MCCB 4 P-4NoChangeoverDigital Meeting |
| 18 | Providing fixing and laying of PVC Conduit 25mm dia |
| 19 | Supply installation testing and commission of outdoor type copper wound Microcontroller-based diigital signal processor 3-phase automatic servo voltage stabilizer as per specification.3 phase input voltage is typically 415V between phases and 230V between phase and neutralOutput voltage: Output voltage is typically stabilized to a specific voltage like 400V or 415V.Output Voltage Regulation: Typically ± 1%.Capacity: Ranges can vary widely, from 15KVA to 250 KVA.Correction rate/speed: Typical correction speeds range from 35-65V/Sec to 70V/Sec, and even > 50 V/Sec, though this may vary for higher-rated stabilizers.Cooling: Oil-cooled stabilizers use oil as a cooling medium first fill of oil as per IS:335/1983Efficiency: Efficiency is generally high, with examples showing 98% efficiency at full load.Protection features: Stabilizers include built-in protection features, such as: Under Voltage (UV) and Over Voltage (OV) protection Output Over Load protection Short Circuit Protection (using HRC Fuses or MCB/MCCB) Phase Reversal ProtectionSingle Phasing PreventionProtection to prevent overcurrent by limiting or disabling current flow,Display and controls: Displays can include backlight LCD or LED Indicators for various parameters like Input/output voltage, frequency, and current. User Interfaces might include buttons for menu navigation and settings adjustment. Complete as required. |
| 20 | Supply, installation, testing and commissioning of dual Inverter type 1.5 Ton AC Hot and Cold make IFB, Bluestar, LG, Layord with connection |
| 21 | Supply and fixing industrial socket for AC's with necessary connection |
| 22 | Supply fixing and connecting 4 KV Stabilizer controlling for AC |
| 23 | Scraping/removal of old plaster/ whitewash including finishing of surface smooth complete job. |
| 24 | Providing and applying 2mm thick white cement based putty of specified thickness, of approved brand and manufacturer, over plastered wall surface to prepare the surface even and smooth complete |
| 25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement. Primer |
| 26 | Providing and fixing the ceiling at all height including providing and fixing of frame wisk made of special sections, power pressed from MS sheen and galvanized with sime cvating of 120 gospa (beah side income) as pa 18-277 and consisting of angle cleats of size 25 mm watex 1.6mm thick with flanges of 27mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 13.5 mm dia xadan long wah & mm dia bolts, other flange of cleat fixed to the angle hangers of 28x1050 Smen of required length with mits & bolts of required size and other end of angle hanger fixed with C.L. 25 channels 45x15x0.9 mm running at the spacing of 1200 centre to centre, to which the ceiling tion 0. Sqmm thick bottom wedge of 80mm with tapered flanges of 26 mm each having clips of 10.3 min at 450mm centre to centre, shall be fixed in a direction perpendicular 10 0.1. Intermediate channel with connecting clips made out of 2.6-4mm diaX230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre to centre, with 25mm longdrive all screws @ 230 mm interval, including fixing of gypsum board/calcium silicate board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25mm at 2.30mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the gypsum board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers' specification and also including the cost of making openings for light fittings, grills diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer-in-Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095-Part 1: 2011 (Board with BIS certification marks) |
| 27 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approve steel primer using structural steel etc. as required in frames, gates and similar wok. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender