Educational and Research Institute Boards / Undertakings / PSU Closing in 2 days TDR #57089345

Tender For Extension Of Lt Line Alongwith Internal Electrification Work, Servo Stabilizer Etc For Chilly Plant Under (Hadp/Capex) At Kvk Haran, Skuast-K.

Issued by Boards / Undertakings / PSU · Srinagar, Jammu and Kashmir
Tender Value
10.04 Lakhs
Estimated cost
Bid Submission
31 Aug 2026
2 days left
EMD
20080
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Srinagar → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Extension Of Lt Line Alongwith Internal Electrification Work, Servo Stabilizer Etc For Chilly Plant Under (Hadp/Capex) At Kvk Haran, Skuast-K.

BOQ

Name of Work:- Extension of LT Line Alongwith Internal Electrification Work, Servo Stabilizer etc for Chilly Plant Under (HADP/CAPEX) at KVK Haran, SKUAST-K.
Sl. No. Item Description
1Supply of Steel tabular poles as per 410 SP 15 with base plate of size 1.5’x1.5’ x 8 mm with GI rod for earthing , painting , Earthing rod and spirla earthing etc .
2Erection of metallic pole of following length in cement concrete1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) foundation including excavation and refillingetc. as required.
3Above 6.5 Meter and upto 8.0 Meter
4Supply , laying and erection of ACSR Rabbit conductor 0.05 with jumpering and termination works.
5Supplying and erection of galvanised 'D' iron clamps complete with shackle insulator (100 mm X 110 mm), G.I. bolts, nuts and washers, coach screws etc. as required.
6S/l of Guy with turn buckler and Guy insulator etc, 8 SWg twisted GI wire laid in cement concrete . Complete job in all respects.
7Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modularswitch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
8Group C
9Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required.
102 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
112 X 4 sq. mm + 1 X 4 sq. mm earth wire
122 X 6 sq. mm + 1 X 6 sq. mm earth wire
132 X 10 sq. mm + 1 X 6 sq. mm earth wire
144 X 4 sq. mm + 2 X 4 sq. mm earth wire
154 X 16 sq. mm + 2 X 6 sq. mm earth wire
16Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies,shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance asper IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. Make USHA /CG/Havells/
171200 mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
18Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser andconstruction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (StandardDeviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connectionswith 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall besubmitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink ofaluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim8.1.1 5 - 7 watt Each 542
1912-15 Watt
20Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement withDriver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥ 0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation 45 DELHI SCHEDULE OF RATES (E&M)-2025Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard.Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sqmm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
2118-22 watt
22LED Tubelight Batten 300mm / Warm White / 5W
23P/f of Industrial exhaust fan 300 mm Make CG / havells /Usha
24P/f of shutter type PVC exhaust fan 200 mm Make CG / havells /Usha
25LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt). 50Watt
26Supplying,Installation,Testing and Commissioning of Indoor type Cubical Type Main Distribution Panel Board double door Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars,Interlocking ,Synchronising etc. as required as per the Following Description.(IP:42) Bus bar 400AINCOMERAdj. TMR Based MCCB 315 Amps FP Icu=Ics=100% Breaking Capacity 50 KA with Extendable ROH (01 Nos)Digital Metering Devices,comprising Voltmeter,Ammeter,Selector Switch,Indicating Lamps,C.T Set,Bus Bar( 400 Amps ) and MCB Strip of suitable size as Required.OUTGOINGS with bypass changeover 125 A FP and bus bar complete (additional )F.P MCCB 250 A 50 KA \\" C\\" Curve(01 Nos)FP M.C.B 32 A 16 KA \\" C\\" Curve(08 Nos)FP M.C.B 125 A 36 KA \\" C\\" Curve(01 Nos)Load Bearing Members to be made out of 2.0 mm CRCA Sheet.Partitions to be made out of 1.6 mm CRCA SheetGland Plates to be 3.0 mm Thick.The Complete Panel Shall be Made out of 2.0 mm CRCA sheet including Frame/Partitions/Doors etc. GI Angle iron stand 50x50x900 mm included.
27Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in groundin DWC Pipe including excavation, without sand cushioning, protective covering and refilling the trench etc as required.
283.5 C X 70 Sq.mm A2XFY
29Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
3012 way , Double door
31Supplying and fixing 5 amps. to 32 amps.rating 240 volts 'C' series, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
32Single Pole
33Single pole and neutral
34S/I of chemical earthing GI -Copper 3 mtr long with Pit and drilling etc , including earthing compound , Pit Cover etc . Drilling etc , Masonary chamber for PVC Pit cover etc as needed at site . Complete work .
35Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
36Supply,Installation,Testing and Commissioning and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (DPMCB),h
37S/ I of geyser 50 Ltr Racold /havells/Venus/Jaguar/Jupiton
38S/I of high bay light 50 Watt LED Cool White , with 2 year warrranty . Complete in mountage and installation works. Preferable Make Havells /Philips /Sysyka /Equivalent
39SITC of Servo stabilizer of following specification: capacity:1. Capacity : 60 KVA BUCK BOOST TYPE2. Input voltage: 155-415 V PP 90V -220V NP 3. Output: 400 Volts +/- 1 % 4. Winding Material : 99.9 % Pure copper wound strip with fibre glass5. Un- balanced type6. Dimmers with heat Sink based technology 7. Cooling : Oil Fresh IS 335 8. Micro Controller LCD True RMS with RS 485 Interface 9. Protection are overload, High Voltage, Under Voltage, Delay line, Single Phase , Preventive Neutral failure, through micro controller & L&T Make Connector 10. Display Parameters are KW, Current Power factor, Input, Output, Frequency, Trouble Shooting11. Auto Manual Selector switch with up/down switch in case card gets fault.12. Heavy duty Al, bus bar wiring input and output.13. Servo stabilizer tank shall be design in MS sheet Heavy gauge as suitable.14.Cooling of oil / Oil Level inlet, lifting huks etc 15. Earth terminal 16. Efficiency more than 98 % 17. Design as per IS 202618. Multi function meters L&T Make19. Warranty 1 year.
40Note:-The rates quoted are inclusive of all carriages of materials (Mechanical/Manual) from source to site work and all extra charges including dewatering if any during the execution of work till complete in all respects. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57089345
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 10.04 Lakhs
LAST DATE 31-08-2026
Authority
Authority Name Sher-E-Kashmir University Of Agricultural Sciences & Technology
Work Description Tender for Extension Of Lt Line Alongwith Internal Electrification Work, Servo Stabilizer Etc For Chilly Plant Under (Hadp/Capex) At Kvk Haran, Skuast-K.
Basic Detail
Tender No E-NIT-42 of 2026-27
Bidding Type Tender
Location
City Srinagar
State Jammu and Kashmir
Key Dates
Publish Date 19 Aug 2026
Submission Date 31 Aug 2026
Open Date 01 Sep 2026
Finance
Tender Value 10.04 Lakhs
Tender Fee 1000
EMD 20080
Exemption Not Available
Document List
05a1e565-9561-4a5f-8b5a-73ec4f77316a.html
BOQ_1074078.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Sep 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
html

05a1e565-9561-4a5f-8b5a-73ec4f77316a.html

xls

BOQ_1074078.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders