Housing Urban and Rular Development Local Bodies Closing in 7 days TDR #57088891

Tender For Replacement Of Existing Defective Light Fixtures/ Fans And Defective Switchgear In Gmsss- Karsan, Chandigarh.

Issued by Local Bodies · Chandigarh, Chandigarh
Tender Value
32.06 Lakhs
Estimated cost
Bid Submission
31 Aug 2026
7 days left
EMD
64125
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Replacement Of Existing Defective Light Fixtures/ Fans And Defective Switchgear In Gmsss- Karsan, Chandigarh.

BOQ

Name of Work:- REPLACEMENT OF EXISTING DEFECTIVE LIGHT FIXTURES/ FANS AND DEFECTIVE SWITCHGEAR IN GMSSS- KARSAN, CHANDIGARH.
Sl. No. Item Description
1DSR item No.1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
2Group-C
3DSR item No.1.17 Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
43 x 1.5 sq.mm
53 x 2.5 sq.mm
63 x 4 sq. mm
7DSR 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
8DSR item No.1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
95/6 A switch
103 pin 5/6 A socket outlet
11DSR 1.26 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
12DSR 1.27 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
134 Module (125 mm x 75 mm)
146 Module (200 mm x 75 mm)
158 Module (125 mm x 125 mm)
1612 Module (200 mm x 150 mm)
17DSR 1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
18DSR item No.1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
19DSR 1.33 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
20DSR 1.38 Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
21DSR item No.1.57 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.
22DSR item No.2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.
23100 A,30KA,FPMCCB
24200 A,36KA,FPMCCB
25400 A,50KA,FPMCCB
26DSR 2.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
276 way, Double door
2812 way, Double door
29DSR Item No.2.5 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required).
308 way (4 + 24), Double door
31DSR 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
32Single pole
33Double Pole
34Triple Pole
35Triple pole and neutral
36DSR item No.2.14 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
37DSR 5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
38DSR item No.5.12 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
39DSR item No.5.16 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
40DSR item No.8.7 LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt) (Recessed/ Surface type)(Please refer DNIT for complete specification of item no.20)
4136 watt
42DSR item No.8.9 LED Batten light (System lumen efficacy ≥105 <120 lm/Watt).(Please refer DNIT for complete specification of item no.21)
4318- 22 Watt
44DSR item No.8.16 LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt). (Please refer DNIT for complete specification of item no.22)
45200 Watt.
46DSR item No.15.16 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
4763 mm dia (OD-63 mm & ID-51 mm manual horizontal boring
4890 mm dia (OD-90 mm & ID-76 mm nominal)
49DSR item No.9.1 Brush Less Direct Current (BLDC) Fan with Remote (Please refer DNIT for complete specification of item no.24)
501400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum)
51Supply & fixing of OEM made Junction box IP-66/67 made out of Polycarbonate with Glass fiber reinforced of size 210x155x90 (minimum) with 5 nos. OEM made connectors/ terminal blocks. The Jn. Box and connectors/ terminal blocks should be supplied by OEM. The terminal blocks/ connectors should be of Hensel/ Wago/ Elmax/ Siemens make only and junction box shall be of Hensel make KF-1616 G or its equivalent Clipsal/ Legrand/ Rittal/ Schneider/ ABB make only. The Junction box shall be fire retardant and self-extinguishing. The gasket material shall be polyurethane and the gasket shall be internally embedded. The job includes the cost of cable glands for cable entry, mounting kit for pipe and post installation, fixing screw, all labour and petty material required to complete the job to the entire satisfaction of the Engineer in Charge of work.
52Supply and erection of MS bracket F type suitable size and suitable shape made form 40mm x 40mm x 5mm thick angle iron to be installed on exiting parapet/ wall with help of suitable size of nuts and bolts etc. for erection of existing LED flood light fittings. The job also includes the cost of painting of box with superior quality of paint and other petty material etc as per required to complete the job.
53Supply and fixing of 12 modules (200 mm x 150 mm) G.I box suitable for accommodate the following accessories along with modular base and cover plate for modular switches in recess/ surface etc as required for Computer Point with 4 Nos. 5/6 Amp. modular switch and 4 Nos. 3 pin 5/6 Amp. modular socket outlet. The job includes the cost of making interconnections with suitable copper wire, painting of box with approved paint and other petty material required to complete the job to the entire satisfaction of Engineer-in-Charge at site. The Modular accessories should be of Lauritz Knudsen (Entice) / ABB (Ivie) / Legrand (Myrius) / Crabtree (Athena)/ Norisys (Square series) make only.
54Supply & erection of Wall Fan 400mm sweep oscillating type complete with blades with regulator. The fan should be of Havells (Swing)/ Usha (MAXX AIR)/ Orient (400mm Wall44)/ Crompton (WM Hiflo wave Plus)/ Bajaj (Esteem Double String) make only. The wall fan should be provided with double string i.e. one no. controlling oscillating and one for speed. The cost including connection with adjacent light points.
55Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operation, epoxy powder coating along with metallic louver to be installed in the existing opening including cost of making the hole to suit the size of above fan making good the damage, Carriage Charges connection, testing, commissioning etc. as required to complete the job to the entire satisfaction of Engineer-in-charge.
56Size 15 inch (380mm) Sweep, 900 RPM Heavy Duty Exhaust fan (Single Phase) with louver of Havells (Turbo Force SP) / Orient (Industrial Heavy Duty)/ Usha (Turbo HDEF)/ Crompton (EXHD300-6-1)/ Bajaj (Supreme Plus) make only.
57S/E of 3mm thick white glazed Bakelite sheet on the existing M.S box. The job includes the cost of sheets and making holes and cutting charges of switches & sockets. The job includes the cost of all labour & petty material required to complete the job. The Bakelite sheet should be of Superhylam/ Greenlam/ Formica make only.
58S/E of on load change over switch of 400 Amp. 4 pole 415 Volt with enclosure. The changeover switch should be of Havells/ Lauritz Knudsen/ Siemens/ Schneider/ABB/ Hager make only. The Changeover switch should be installed in existing cubicle panel / angle iron board/ including drilling holes in cubicle panel / angle iron board, making connections with suitable rating of copper wire / copper strip etc. as required. The job includes the cost of all petty material and labour charge etc as required to complete the job to the entire satisfaction of Engineer-in-charge.
59Supply and erection of sheet metal cubical pedestal of suitable dimensions made from 50 mm X 50 mm X 6 mm thick M.S angle iron frame, covered with 1.6 mm thick M.S. sheet duly welded on five sides and front side hinged complete with locking arrangement with 4 Nos. switchgear supporting members each of M.S. flat 50 mm X 6 mm thick of suitable length duly welded. The cubical pedestal shall have 4 Nos. legs of 50 mm X 50 mm X 6 mm each 60 cm long M.S. angle iron each long including painting, bonding to the existing earth etc. the same shall be erected in the 1:2:4 cement concrete plat-form of suitable dimensions 15cm high form ground level and 45 mm thick. The cubical pedestal shall be 15 cm from the top of cement concrete platform.
60Cubical size 1000 mm X 1500 mm X 500 mm
61Supply and laying of XLPE insulated PVC sheathed Aluminum conductor armoured cable of 1.1 KV grade as per IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be laid in existing Trench/Ducts/Cable Tray/ RCC/ HUME/ METAL/ DWC pipe / on surface with the help of MS clamps of suitable size/ as required at site to the entire satisfaction of Engineer-in-Charge. The job includes labour charges of laying the cable and making connections with suitable size aluminum lugs/thimbles etc. The cable shall be of Polycab / Havells / R.R. Kabel/ KEI/ Finolex make only.
6216 sq.mm 4 core (In existing pipe)
6316 sq.mm 4 core (On surface)
64185 sq.mm 3.5 core (In existing pipe)
65Supply fabrication & erection of M.S. angle iron board covered with 14 GMS sheet fixed in to the nitch for mounting switchgear. The board shall be fabricated out of 40mm x 40mm x 5mm angle iron frame and shall be covered with a 14 GMS sheet duly welded for erection of switchgear on it. The switches /BDB’s / ELCB shall be provided with required no. of supporting member of M.S. flat 25mm x 5mm to bring all the switchgear in one level including bonding the board switchgear etc. to the existing earth. The board shall be painted with two coat of approved shade of superior quality paint after one coat of primer. The rate includes carriage from factory to site, erection charges in the niche and other petty material required at site of work.
66Supply & erection of Adopter box of suitable size required made out of 16GMS sheet The box to be provided with front detachable cover and having holes of out going/ incoming pipe/ cable/ wire/ pipe. The boxes shall be painted with 2 coats of approval paint after applying one coat of primer. The size and design of the boxes shall be as per actual requirement at site. The box is fixed on existing surface by rawl plugs/ screws etc. suitable
67Supply & erection of fan hook for erection of ceiling fan. The hook shall be made out ½” dia MS bar in U shape formation. It shall be fixed after chasing the RCC slab and making necessary repair, plaster and making its original position.
68Supply and erection of sheet metal bus-bar chamber on existing surface with required No. of bus-bar strips of suitable length and cross-sectional area, made of copper strips of suitable length and cross-sectional area enclosure made of M.S. sheet 1.6mm thick with detachable cover fitted with dust excluding gasket and secured with sufficient No. of cadmium plated iron screws and of given overall dimensions and to be fixed with G.I. bolts and nuts/Rag bolts and nuts etc., complete with all accessories including connections with suitable size tin coated copper thimbles, bonding to the existing earth and painting etc. as desired by the Engineer-in-charge.
69Sheet metal bus-bar chamber suitable for 400 Amp. 3’ long 415 Volts capacity with 4 copper strip Bus-bars each of length 900 mm & cross-sectional area (38.10mm x 6.35mm) enclosure having overall dimensions (980mm x 550mm x 200mm) nominal.
70Dismantling of existing switch board box and repairing the same with cement and sand. The job includes the cost of all labour and other petty material required to complete the job to entire satisfaction of Engineer-in-charge.
71LED Panel light 1x4 ft. (System lumen efficacy ≥120 <135 lm/Watt) (Recessed/ Surface type) (Please refer DNIT for complete specification of item no.39)
7233 Watt./ 36 Watt. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57088891
AUTHORITY Local Bodies
TENDER VALUE 32.06 Lakhs
LAST DATE 31-08-2026
Authority
Authority Name Chandigarh Administration Engineering Department
Work Description Tender for Replacement Of Existing Defective Light Fixtures/ Fans And Defective Switchgear In Gmsss- Karsan, Chandigarh.
Basic Detail
Tender No E2/26/77
Bidding Type Tender
Location
City Chandigarh
State Chandigarh
Key Dates
Publish Date 19 Aug 2026
Submission Date 31 Aug 2026
Open Date 31 Aug 2026
Finance
Tender Value 32.06 Lakhs
Tender Fee Ref. Documents
EMD 64125
Exemption Not Available
Document List
56b63871-61bf-4b09-8ccd-78d09eb44c28.html
BOQ_116467.xls
Tendernotice_1 (18).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Aug 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

56b63871-61bf-4b09-8ccd-78d09eb44c28.html

xls

BOQ_116467.xls

pdf

Tendernotice_1 (18).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender