Defence Statutory Bodies & Commissions/Committees Closing in 19 days TDR #57088804

Tender For Addn/Altn To Bldg No P-35-37 Of Cook House And Provn Of Geysers And High Mast Light With 15 Meter Long Pipe And Connected Item At Nabha Under Ge (S) Patiala

Issued by Statutory Bodies & Commissions/Committees · Patiala, Punjab
Tender Value
36.11 Lakhs
Estimated cost
Bid Submission
09 Sep 2026
19 days left
EMD
73000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Patiala → Punjab
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Addn/Altn To Bldg No P-35-37 Of Cook House And Provn Of Geysers And High Mast Light With 15 Meter Long Pipe And Connected Item At Nabha Under Ge (S) Patiala

BOQ

Name of Work:- ADDN/ALTN TO BLDG NO P-35-37 OF COOK HOUSE AND PROVN OF GEYSERS AND HIGH MAST LIGHT WITH 15 METER LONG PIPE AND CONNECTED ITEM AT NABHA UNDER GE (S) PATIALA
Sl. No. Item Description
1'Notes: (i) Please refer Schedule 'A' Notes of tender documents.
2Taking down cement or cement lime plaster on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed.
3M&L for 15mm thick cement pastering in cement mortar 1:4 and mixig the water proofing compound as per manufactures instructions on brick or concrete surface of wall finished complete all as specified and directedNote : Water proofing compound shall be measured and paid saparately under item
4M&L 10mm thick cement plastering in cement mortar CM 1:6 finishing the surface even and smooth without using extra cement complete all as specified and directed.
5Complete removal of existing treatment of any type/description such as distempering work ,internal emulsion etc from internal/external surfaces of walls & ceiling with mechanical means/grinder including removal of material from site complete all as specified and directed.
6Material and Labour for exterior painting work including complete removal of existing loose paint layers till plaster level by using jet pressure washer and crack filling up to 3mm by using crack seal & up to 10mm by using textured crack filler. 1.5 mm thick wall putty with silicon additives followed by application of one coat of truecare exterior primer on walls and Chajjas and applying two coats of modified acrylic smooth emulsion exterior grade with silicon having anti-algal and Dust pickup resistance properties, Material should be applied (Dilution, Recoating period etc..) as per manufacturer instructions by using fully automatic air less spray machine having flow speed of minimum 1ltr per minute and pressure of 3300 PSI.Note-The above Specification is guaranteed for 4 year performence warrantyNote- (i) The contractor shall submit manufacturer generated 04 years warranty card for each buildings treated/ painted during submission of Final Bill and guarantee amount @ 5% will be kept as reserve till completion of warranty period and will be released thereafter. Any deterioration during the warranty period will be rectified by the contractor without any financial effect within a week.
7(ii) The work shall be executed by the contractor as per MoU from authorised applicator through manufacturer of the materials like Exterior/Interior Paint, Putty etc after approval by the GE.(iii) The Lowest bidder shall submit the \\"Memoradum of Understanding\\" (MOU) as per format given in Annexure ‘A’ after Schedule 'A' Notes with at least one of the manufacturers mentioned in the contract, after acceptance of the bid but before commencement of the work. If he fails to submit the same as referred above, his contract shall liable to be cancelled.(iv) Cost of T&P and a scaffolding/Jhoola, trestles, ladders, cradeles, centring, crane, boom lifts/ crane of any type and shuttering etc necessary for execution of work and protective measures complete upto all height shall be deemed to be included under respective item.(v) Cost of temporary covering to all joinery items (like doors, windows, window panes), sanitary fittings, dado/skirting, floors, etc to protect them from splashes.(vi) Packing material/empty Buckets will not be handed over to the contractor and will be property of the MES and will be disposed off with the permission of the Engineer-in-Charge and GE.(vii) Washing floors, cleaning glass, joinery , electric fittings , wirings etc. Drops and splashes of paint to be cleaned to the entire satisfaction of Engineer-in-Charge.(viii) Sample patch of 10Sqm be prepared and shall be got approved from GE prior to carrying out further work.(ix) Cost of removing of nails, making good holes, filling of cracks with acrylic crack filler paste etc shall be deemed to be included under respective item.(x) Work in patches and in narrow / widths, bands, cornices, pilasters etc and cutting in edge of line where necessary.
8Supplying & applying for two component elastomeric acrylic polymer modified cementitious waterproofing coating on Brick level, SmartCare Damp Block 2K or approved equivalent (For Effloresce treatment), having 100% elongation as per ASTM D412, resisting 5 bars hydrostatic pressure as per DIN 1048, reduction to rapid chloride shall be 70 as per ASTMC1202, crack bridging up to 1.2mm as per ASTM 4548.5. The coating shall have food grade certificate from laboratories like CFTRI, will be apply on both Positive & Negative side and resist up to 5 Bars of Hydrostatic Pressure. The mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing, etc. After coating will sprinkle Sand on the coating is in contractor scope, complete as manufacturer specifications and complete all as specified and directedNote-Taking Down Cement Plaster and Rendering will be paid seprately
9M&L prepration of new plastered or unplastered surface of walls and applying two coats of oil Bound Distemper over complete all as specified and directed
10Supply only integral water proofing compound ISI marked, complete all as specified and directed
11M&L for rendering 5mm thick in cement mortar 1:3 as on concrete surfaces in ceiling finished even and smooth without using extra cement complete all as specified and directed
12M&L for preparation of new plastered or unplastered surfaces applying three coat of white wash on ceiling surfaces complete all as specified and directed
13M&L for preparing old plastered surfaces of ceilings and applying one coat of white wash in all as specified and as directed.
14Taking down chowkhats or frames (without taking off shutters from the frame) exc 1.5 Sqm and n. exc 4.00 Sqm incl cutting holes and making good reqd shape for hold fast block for new frame complete all as specified and directed
15All as per srl item No 13 hereinbefore but n. exc 1.5 sqm each complete all as specified and directed
16S&F Powder coated Pressed steel frames made of MS sheet of 1.25 mm thickness for doors with single rebate including necessary fixing lugs, hinges, lock strike plate, hold fasts ,filling PCC 1:2:4 B1in hold fast blocks etc., complete as specified,size 105x 60mm including cutting holes and making good reqd to shape for hold fast blocks for new frame complete all as specified and directed.Note :- Disturbed portion of existing floor /wall / tile / plaster etc duing fixing of chowkhats shall be repaired to match with existing finish and Cost of the same will be included in this item
17S&F Powder coated Pressed steel frames made of MS sheet of 1.25 mm thickness for doors with double rebate including necessary fixing lugs, hinges, lock strike plate, hold fasts ,filling PCC 1:2:4 B1 in hold fast blocks etc., complete as specified,size 125x 60mm including cutting holes and making good reqd to shape for hold fast blocks for new frame complete all as specified.Note :- Disturbed portion of existing floor /wall / tile / plaster etc duing fixing of chowkhats shall be repaired to match with existing finish .Cost of the same will be included in this item
18M&L Plain cement concrete (1:3:6) type B-0,using 12.5 mm graded mechanically crushed stone aggregate as in back filling of pressed steel frame /hold fast blocks etc and similar complete all as specified and directed.
19S&F 35mm thick plain framed (Factory made) Panelled shutters of 2nd class HW without lock rail and panels of 9mm B.W.P commercial ply including beading on the facing side of shutters as per SSR Part I clause No 8.17.5. The size of rail and stiles as per IS 1003 (Part I) kiln seasoned and chemically pressure treated complete all as specified and directed.
20S&F 35mm 2nd class hard wood Glazed and skeleton shutters, 2nd class hard wood open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed.
21S&F Mild steel barrel tower bolt 200mm long stove enamelled black with bright bolt and fixed complete all as specified and directed.
22S&F Mild steel sliding door bolt of size 250mm , stove enamelled black with bright bolt not less than 12 mm dia, with and including a minimum of 6 bolts and nuts, complete all as specified and directed.
23S&F MS pressed handles of size 125mm oval type stove enamelled black, complete all as specified and directed.
24S&F 300 mm long MS rat tail pattern spring hinge including roller and roller plate, complete all as specified and directed
25S&F Floor door stopper of aluminum alloy body and tongue, anodised, with hard drawn steel spring fixed in floor ,with 140 mm overall length of cover plate complete all as specified and as directed.
26Providing and fixing factory made extruded aluminium casement windows with 50 micron powder coating doubled panelled and double shutters consisting of frame and mullion of 101.60X44.45X1.29 mm and shutters made of 63.5X31.75X1.29mm and to be fixed with and including EPDM gasket to render the glazing, air and water tight etc. & aluminium beeds 20mm size with and including 5mm thick glass in front shutters and stainless steel wire gauge 0.36mm dia and 1.40 aperature in inner shutters complete fixed in all respect as specified including supply and fixing following items :-(a) Stainless Steel (304 Grade) Finished Butt Hinges 150mm - 2 nos per leaf.(b) Powder Coated Aluminium Tower Bolt 150mm long - 2 nos per leaf.(c) Powder Coated Aluminium Handles 150 mm - 1 nos per leaf.
27S&F anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard sectionand fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, complete all as specified and directed
28S&F power coated 50 microns extruded aluminium ventilators with 50 micron coating of frame of 63.5x38.10x1.29 mm including 5mm thick frosted glass in lower 60% portion of shutters and stainless steel wire gauge 0.36mm dia and 1.4 aperture in upper 40% portion of shutters and stainless including EPDM gasket to render the glazing, air and water tight etc & aluminium beeds 20mm size complete fixed in all respect complete all as specified and directed.
29S&F in repair Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed
30M&L for preparing of new surface of wood and wood based material of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamel pain and one coat of pink primer complete all as specified and directed.
31M&L for preparing surfaces of any description over 10 cm girth or width, not otherwise described and applying two coats of synthetic enamel paint over a coat of Red oxide on new surfaces of steel or iron, complete all as specified and directed.
32Taking Up or down steel tubing of size 15mm bore and removal to store complete all as specified and directed.
33Supply and laying of 20mm outer dia CPVC pipes SDR11 & plain CPVC SDR 11 fitting fixed on wall / celling or laying in floor complete all as specified and as directed.
34S&F in repair Rotational moulded polythene water storage tank cylindrical vertical with closed top 500ltr capacity (ISI Marked) hoisted and fixed in position incl 20 mm bore ball brass valves high pressure with polythene float and fly nut all as specified in SSR Part-1.incl Dismantalling of old PVC tank and complete all as specified and directed
35S&F in Repair Bib taps with long Nose for 15 mm dia bore pipe cast copper alloy cromium plated with capstain head screwed down for iron pipe or brass ferrule and fixed and complete all as specified and directed
36S&F in Repair 20mm Stop valves/ gate valve , cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and complete all as specified and directed
37S&F in Repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs washers and wastes icluding bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe over all size 915mm x 460mm bowl size 410mm x 330mm x 160mm, complete all as specified and directed.
38Demolition of cement concrete (un-reinforced) in ground floors and pavings n exc 15cm thickness (below or above ground level), complete all as specified and directed.
39M&L 25mm thick PCC (1:2:4) type B-0 using 12.50 mm graded crushed stone aggregates in complete all as specified and directed.
40M&L for Ceramic Vitrified floor tiles of 7 to 8mm thick of size 600 X 600 mm in floor etc set and jointed in neat cement lurry and pointed in white cement to match over and including 15mm thick screed bed in CM (1:4) laid in complete all as specified and directed.
41Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed
42M&L Vitrified Ceramic tiles light shade 10 mm thick of size 600 X 300 mm as in wall tile, skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10 mm thick screed bed in cement motar 1:4. complete all as specified and directed
43M&L for 20 mm thick Granite (of any type, table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed
44S&F in Repair Stainless steel chromium plated 20mm curtain rod with fixing brackets, stops rollerss complete incl fixing brackets, stops etc all as specified & directed.Note For the purpose of mesurement and payment running length of curtain rod only shall be considered.
45Dismantling of brick tiles or terracing tiles single layar on roofs complete all as specified and directed
46Demolation of mud puska and removing on roof any thickness complete all as specified and directed
47M&L for PCC 1:2:4, type B-0 using 12.5 mm graded stone aggregates as in Roof Padding/ roof kerbs or mud stops/ coping etc including weathering slightly rounded or chamferred finish even and smooth without using extra cement complete all as specified and directed
48M&L for the following roof treatment.(a) Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3mm thick weight not less than 3.60kg/Sqm water proofing membrane, black finished reinforced with non woven polyester matt, fixed as per manufacturer’s instructions complete all as specified and directed.(b) Applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 kg per square metre including cleaning the surfaces all as directed and specified.
49S&F PVC ( SWR) rain water pipes 110 mm bore single socketed in any length with rubber ring joints fixed to walls complete as as pecified including flat iror clamps 25x3mm complete all as specified including taking out old damaged AC rain water pipes.
50M&L Hard core of broken bricks of gauge n exc. 63 mm spread and levelled in layers n exc.15cm thick, watered and rammed to a true surface complete all as directed and specified
51M&L for PCC (1:3:6) C2, 50mm thick as in PCC path/ plinth protection.finished the surfaces even and smooth with out using extra cement complete all as specified and directed
52M&L for Machine cut Kota stone slab flooring 20mm (+2mm) thick laid over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4 as base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
53All as per item No 51 here in before on vertical surfaces as in skirting/dado of size as required at site complete all as specified and directed
54M&L anodised aluminium snap grid false ceiling (Black Groove type) of grid size 605x605mm consisting of aluminium main and \\"T' sections of size 25x35x1.5mm thick and wall angles of size 25x 25x 1.5 mm thick suspended with GI wire suspenders of 6mm dia of suitable length and 8-10 mm thick gypsum board, 60x60 cm size fixed with staples on snap grid complete all as specified and directed.
55S&F for Solid PVC wall Lining (Fluted)Consisting of 5mm thick colour PVC sheet in Strips & Channel feathered at the edge of fixing on solid PVC wall lining and solid PVC pertition inclusive of solvent cement and fixing at site but single side prelam PVC sheet used insted of plain colour sheet, complete all as specified and directed
56S&F for pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/clading to wall, fixed to self tapping screws complete all as specified and directed
57S&F MS hollow rectangular/square/circular tubes/pipes of Fe410-W(Gde-E-250) Grade as in frame work for roof/rafter/purline/chajja/trusses/columns/struts etc and like similar items etc. complete all as specified and directed.
58Demolition of brick work or stone masonry built in cement mortar including all quions, arches, pillers, etc complete all as specified and directed
59M&L for Brickwork with fly ash bricks, old size, straight or curved on plan exc 6m mean radius, built in in cm 1:6 with sub class ‘B’ bricks straight or curved on plan exc 6m mean radius complete all as specified and directed
60S&F Fe-410 (Gde E-250) Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening complete all as specified and directed
61S&F 18 mm thick LEAD FREE PVC celuka ply of approved color fixed with screws, slovent cement/adhesive to make kitchen/bed rooms cabinet sides top and bottom and shelves inside the cabinets complete as per manufactured's specification complete all as specified and directed.NOTE: not less than 10kg per sqm
62S&F 12 mm thick LEAD FREE PVC celuka ply of approved colour, fixed with screws, slovent cement/adhesive to make wall mount kitchen cabinets back and pull out drawer sides complete as per manufactured's specification complete all as specified and directed.
63M&L for applying acrylic thick wall care putty on internal/external surfaces of walls/ ceilings /soffits (thickness vary from 1.5 to 2.5mm as required for desired smoothness and levelling of surfaces in two or more layers)by us ingready made wall careputty including sand papering after filling the putty to make surface smooth and ready for receiving painting etc complete all as specified and directed.
64S&F Ball bearing runners 45 mm Telescopic (KTS-20) full extension load capacity 50 Kg complete all as specified and directed
65S&F Paino/continuous hinge of size 30 mm stainless steel complete all as specified and directed
66S&F ball catchers 304 grade stainless steel finished suitable for cabinets premium quality complete fixed in position as per manufacture's instructions and complete all as specified and directed
67S&F D-type cabinet handles premium quality, stainless steel 304/gloss chrome/SN finished 150 mm long matt finished complete fixed in position complete all as specified and directed
68S&F stainless steel 304 grade wire Basket (avg wait 2.5 to 4 Kg per basket) of pull out type like plain/cup& saucer/bottle/multi purpose/2-3 shelf baskets etc for kitchens of required suze complete fixed in position and complete all as specified and directed
69M&L for reinforcement cement concrete (Normal mix )1:2:4 Type B1 (20mm graded aggregate) as in slab support on wall , beams and collums in floor roof landing balconies deck slab and in shelves and complete all as specified and directed
70Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed
71Use & waste of formwork to sides and soffits of floor and roof beams ,lintels beam ,cantilevers ,shelves including supports ,overhangs and similar work , for rough finished flat surfaces complete all as specified and directed
72M&L for plain cement concrete tiles with grey cement and pigment 20cmX 20cmX25mm thick, machine pressed; set jointed and pointed in neat cement slurry in floors, over 15 mm thick cement screed bedding layer in cem,ent mortar 1:6, complete all as specified and directed
73Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete with fittings and fixtures such as switches, ceiling roses, pendants, regulators, socket, lamp, holders brackets, bulk head, mirror light fittings etc removing material for taking credit ( credit shall be recovered as per credit Sch attached) and also making good disturbed surfaces of wall, floors etc complete all as specified and as directed
74M&L for point wiring with 1.50 sqmm in copper conductor cable ( multistrand) FRLS single core PVC insulated cable in and including PVC concealed conduit ( ISI Marked) of heavy duly with all accessories ie PVC gutties etc terminated in sunken/pressed metal flush box and white modular cover plate with frame for mounting of switches /sockets/ fan regulators etc and continuous earth wire 1.5 Sqmm copper cable PVC insulated FRLS controlled by one switch for one light/fan/sockets point/ in ceiling Portion surface conduit wiring to be done and complete all as specified and as directedNote : i) Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra costii) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth.(iii) Necessity cutting chasing where ever required shall be part of job & making good the disturbed surfaces shall be part of job.
75All as per item No 73 above, but for one 3/5 pin socket outlet 5 Amp on the same board with other switches complete all as specified and as directed
76All as per item No 73 above, but for one 3/5 pin socket outlet 5 Amp on independent board complete all as specified and as directed.
77All as per serial item No 73 here-in-before, but for one socket outlet 15 Amps on independent board with 2.5 Sqmm copper conductor ( Multi-stranded) PVC insulated and unsheating electric cable 1100 volts (ISI Marked) including PVC insulated and unsheathed electric cable 1100 volts 2.5 Sqmm copper stranded conductor as continuous earth wire connected to common earth dolly complete all as specified and as directed.
78S&F in replacement of modular switch 1 way, 6 Amps, 1 module complete all as specified and as directed
79S&F in replancement of modular type, switch 1 way, 16 Amps, 1 module complete all as specified and as directed
80S&F in replacement of modular type, socket 5 pin 6 Amps, 2 module complete all as specified and as directed
81S&F in in replacement of modular socket 5 pin 6/16 Amps, combination type 2 module complete all as specified and as directed
82S&F in replacement modular Fan regulator step type, 120 watts, 1 module complete all as specified and as directed
83M&L in replacement for Ceiling rose modular surface type, 65 mm x 50 mm two to three terminals / PVC / polycarbonate, isolated body fixed on PVC block complete all specified and as directed.
84S&F in replacement Vertical load line type VTPN DB, 4 way 415 V, double door as per IS - 8623, IP-54 protection, universal mounting with suitable capacity copper bus bar with nuetral bus bar, earth bar and cable ties for cable management, top and bottom removable gland plate suitable for accomodate MCCB TPN 100 Amp as incomer and TP&SP MCCB/MCBs as outgoing complete & making necessary electrical connection for incoming and outgoing cables, with copper lugs, crimpped with crimping tool complete all as specified and directed.Note: (i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble.(ii) The disturbed surface shall be match with existing shall be part of job.
85S&F in replacement of existing MCCB TPN, 63 Amps, 415 volts, 16 KA complete fixing in DBs including proper thimbles connections complete all as specified and directed.
86S&F in replacement SPN DB suitable for MCBs of single pole and neutral 12 Way as per IS - 8623, IP-54 protection,double door type with 200 amp rated bus bar.Note: i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble.(ii) Dismantling of existing sheet metal box will be deposited to MES. (iii) Masonry work to fill the space of iron sheet box will be part of the job.(iv) Energy Meter will be refixed & connected after fixing of new DB. (v) MCB'S shall be fixed with copper wires FRLS 1.5/2.5 Sqmm incl appropriate size of brass/Cooper thimbles.(vi) Existing metal enclosure of SPN DB will be deposited to MES.
87S&F in replacement 240V, 10 KA 'B' curve miniature circuit breaker (MCB SP) of single poles and current carrying capacity 6 to 32 Amp, in the MCB DB Complete with connection testing and commissioning complete all as specifed and directed
88S&F 240V, 10 KA 'B' curve miniature circuit breaker (MCB) SPN current carrying capacity 32 Amp, in the MCB DB complete with connection testing and commissioning complete all as specifed and directed
89S&F in replacement FTL with new techonlgy LED having high efficiency of capacity LED 20 Watt, 4 feet long, FIXT ELITE PRIDE PLUS 20 W 6500K, Cool Day Light (CDL) LHEXBLP7PN1W020. incl necessary electric conection complete all as specified and as directed
90S&F in replacement new generation energy saving and environmental friendly long life LED building security light 35 watt (110 lumen/watt) made up of pressure die cast alluminium housing with high power LED as light source and lense embedded PC cover having TOP OPENING separate driver compartment with IP65 protection and impact resistance of IK07, with all accessories including suitable bracket with suitable dia light grade GI pipe bend to shape, including MS clamp of size of required size and PVC cable 1.5 Sqmm twincore from ceiling rose to light fittings complete all as specified and directed.
91M&L in replacement for earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth plate not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth wire 4mm dia by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) including iron angle frme 40*40*6mm. and medium grade GI watering pipe 20mm dia with funnel and wire mesh and 15 mm bore GI pipe light grade proection pipe including excavation and charcoal ,common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I
92S&F Ceiling fan complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless current motor (BLDC) direct with remote control include writting MES No. with black/white synthetic enamel paint and complete all as specified and directed.(Note: - UNSV C/Fan will be deposited to MES office).
93S&F Exhaust fan 300 mm sweep, metal body type AC single phase 240 V with louver. Note : Fixing of exhaust Fan on wall with suitable size anchor bolt , cutting wall for making hole suitable for 300 mm sweep exhaust fan, grouting and making good the disturbed surface shall be part of job at no extra cost include writting MES No. with black/white synthetic enamel paint complete all as specified and directed.(Note: - UNSV Exhaust Fan will be deposited to MES office).
94Supply and fixing in replacement post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp and complete all as specified and as directed
95S&F in replacement 1100 volts grade heavy duty XLPE insulated, armoured heavy duty electric cable with aluminium conductor cross-sectional area 16 sq. mm, 4 core incl grouting into wall , connecting to DB/Panel with suitable size coppr thimbles, making good/mahing the surface of wall complete all as specified and directed.
96Excavating in trenches n exc 1.5m wide and n exc 1.5m deep and getting out in soft/loose soil complete all as specified and directed.
97Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as specified and directed.
98Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
99M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable complete all as apecified and directed.Note: Only punned sand shall be measured and paid separately
100Supply and laying in replacement well burnt sub class ‘B’ bricks. ( designated 75) locally available best quality laid dry in trenches for protection of underground cable complete all as specified and as directed
101Material and labour in replacement for of of GI tubing light grade 50 mm bore for passing through cables under the floor, along the wall or along the pole complete all as specified and directed.
102S&F Geyser (water heater) vertical storage type 240 volts, 2000 Watt, water proof IPX-4 Pprotection having adjustable knob for temperature settings, copper cell of 25 Ltr capacity, 5 star rating with all accessories such as safety valve, thermostate, NRV, connection piece etc. and incl cost of anchoring arrangement (nut & bolts) to the wall, corded copper electric cable etc incl dismantling of existing geyser and writting MES No. with black/white synthetic enamel paint complete all as specified and directed.(Note:-Unsv Geysers will be deposted to MES office.
103Supply and install hi wall split Air Conditioner units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with 5 star rating and EER 3.2 of capacity 2 TR include writting MES No. with black/white synthetic enamel paint complete all as specified and directed
104Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA include writting MES No. with black/white synthetic enamel paint complete all as specified and directed.
105S&F in replacement of existing unserviceable Plug & Socket Box (sheet metal) with PVC Plug, SPN 20 Amps for Acs complete all as specified and directed.Note :(i) Including cost of masonary work involved and the disturbed surface shall be repaired/match with existing shall be part of job.
106M&L Cutting of road /PCC path upto the depth of pipe & making good the disturbed surface with PCC 1:2:4 (20 mm aggregate) using extra cement including earth work complete all as specified and directed.
107M&L in replacement for Sub main wiring with 2 runs of single core FRLSH PVC insulated unsheathed multistranded copper conductor cable of size 2x4 sqmm ( line conductor) & 1x4 sqmm ( earth conductor), 1100 volt grade drawing in & including heavy duty non metallic PVC conduit , ISI marked, incl accessories not less than 25 mm in dia & concealed in wall, roof etc including PVC insulated, FRLSH unsheathed single core multistranded copper conductor cable, green in colour as earth conductor including cutting charges for concealed conduit wiring etc and making good cutting not exceeding 10 cm grith complete all as specified and directed.Note:(i) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth(ii) Connections of cables with MCBs or bus bars shall be done through brass/copper thimbles of appropriate size(iii) Two runs of copper conductor cable and one run of copper earth wire including PVC conduit will be measured and paid as one unit only.
108M&L in replacement for Sub main wiring with 2 runs of single core FRLSH PVC insulated unsheathed multistranded copper conductor cable of size 2x6 sqmm ( line conductor) & 1x6 sqmm ( earth conductor), 1100 volt grade drawing in & including heavy duty non metallic PVC conduit , ISI marked, incl accessories not less than 25 mm in dia & concealed in wall, roof etc including PVC insulated, FRLSH unsheathed single core multistranded copper conductor cable, green in colour as earth conductor including cutting charges for concealed conduit wiring etc and making good cutting not exceeding 10 cm grith complete all as specified and directed.Note:(i) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth(ii) Connections of cables with MCBs or bus bars shall be done through brass/copper thimbles of appropriate size(iii) Two runs of copper conductor cable and one run of copper earth wire including PVC conduit will be measured and paid as one unit only
109Supply and fix including commissioning of 15M high mast 360/150--3/3 shaft in two section suitable for 47 m/sec wind speed along with head frame, luminaires carriage suitable for 6-9 luminaires in symmetrical arrangement and other accessories manufactured in factory. Supply of raising lowering system comprising double drum winch, 4mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightning finial and aviation light etc complete including all accessories. All as specified and directed by Engr-in-Charge. (a) Supply and fix foundation bolts along with nuts, washers, anchor plate and common template.(b) Supply and fix LED type single dome aviation obstruction light.
110Material and labour for construction of shallow foundation with concrete for the highmast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 metre depth with all materials and labour and including the erection of the high mast with the help of suitable tools and plants, wiring of luminaires with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 1.5 sq. mm, lugs, MCB and all labour and Installation of the mast feeder pillar by grouting the stand in concrete complete all as specified and directed.
111Supply and fixing LED flood light 250 watt 230 Volts, AC, outdoor type with thermal management in multiple optics and equipped with IP-66 protection, with impact and corrosion resistant complete with driver and lamp, to be mounted on high mast pole and complete all as specified and directed.
112Supply and fixing in repair of automatic street light control switch single phase 5-8 KW 40 Amps using infrared sensor based nature switch for automatic switching of street lights. Nature switch operation should be based on Natural light lux level. The sensor along with suitable power contactors and incoming out going MCBs should be enclosed pole/wall mounted thermo plastic polycarbonate enclosure conforming to IP 66 Protection Class 2, and complete all as specified and directed.
113M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth plate not less than 3.25 mtr deep below the normal ground level ) with top edge of plate not less than 2.5 mtr below the normal ground level connected to galvanised iron strip 32×6mm by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC/CI cover in PCC 1:2:4 (type B-1) medium grade GI watering pipe 20mm dia with funnel and wire mesh and 40 mm bore GI pipe light grade proection pipe up to test point etc including excavation and charcoalt ,common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I complete all as specified and directed.
114Supply and laying LT Cable & Supply, laying, Jointing connecting LT UG cable XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 16.0 sqmm 4 core laid in trenches/on poles/walls/in ducts/passing through pipes and including necessary cable lugs, bolts, nuts and washers complete all as specified and directed.Note:- Earth work will be measured and paid separately under relavant items of schedule
115Material and labour for GI tubing 40 mm dia light grade for passing through cables under the road, floor, along the wall or along the pole of the following dia complete all as specified and directed.
116Supply and fix electric water heater, storage type steel body with copper inner tank and heating copper element upto 2 KW capacity 50 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, PVC hot & cold water connection pipes, fastners etc. include writting MES No. with black/white synthetic enamel paint all as specified and directed.
117S&F Steel water tubing, 15 mm bore, medium grade, galvanised with all fittings and fixed to walls and ceiling or laid in floors for providing water supply connection to the Geyser inlet and out let including extented connection to Kitchen complete concealed or surface run as per site requirement and complete all as specified and directed.
118S&F heavy duy PVC Tap of 15 mm dia including fittings such as socket, nipple, elbow complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57088804
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 36.11 Lakhs
LAST DATE 09-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Addn/Altn To Bldg No P-35-37 Of Cook House And Provn Of Geysers And High Mast Light With 15 Meter Long Pipe And Connected Item At Nabha Under Ge (S) Patiala
Basic Detail
Tender No GE(S)/PAT/T-57/2026-27
Bidding Type Tender
Location
City Patiala
State Punjab
Key Dates
Publish Date 19 Aug 2026
Submission Date 09 Sep 2026
Open Date 11 Sep 2026
Finance
Tender Value 36.11 Lakhs
Tender Fee 500
EMD 73000
Exemption Available
Document List
59e2d815-7fd7-4f04-8564-c93ac8f2ab90.html
BOQ_879782.xls
T-57.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Sep 11, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
html

59e2d815-7fd7-4f04-8564-c93ac8f2ab90.html

xls

BOQ_879782.xls

pdf

T-57.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders