Educational and Research Institute Government Departments Closing in 3 days TDR #57088750

Tender For Supply Installation Testing and Commissioning of Auto-Sequential Timer Panel In Different Sites At Iit Delhi

Issued by Government Departments · Delhi, Delhi
Tender Value
7.45 Lakhs
Estimated cost
Bid Submission
27 Aug 2026
3 days left
EMD
14902
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Supply Installation Testing and Commissioning of Auto-Sequential Timer Panel In Different Sites At Iit Delhi

BOQ

Name of Work:- SITC of Auto-Sequential Timer Panel in Different Sites at IIT Delhi
Sl. No. Item Description
1Supply, installation, connections, testing and commissioning of sequential timer panel for automatic operation of two AC units with manual provision and settable / adjustable time slot comprising following components etc. complete as required. TIMER PANEL FOR TWO AC (a) Suitable size sheet steel enclosure of 2/1.6 mm thick duly powder coated painting with IP-42 protection, (b) 40 A DP MCB, 10kA, \\"C\\"-Curve - 1 nos., RYB Indicating Lamps, 22.5 mm Dia LED Type -1 nos., 2A SP, MCB 10kA , \\"C\\"-Curve -3 nos. AC3 Type category 2 Pole power contactor ML-1.5 type - 02 nos., (c) Analog GIC type Quartz Timer 240 VAC - 24 hour - 1 no., (d)2A SP, MCB, \\"C\\" Curve (e) LED type ON indication lamp, (f) Illuminated type ON-OFF push button, (g) Auto - Manual Selector / Toggle switch, (h) Aux Contactor for NO + NC - 02 nos. (i) SMC / DMC Connector with nuts & bolts as required, (j) Internal copper wiring with not less than 4.0 sqmm copper wire, (k) CRCA Powder coated enclosre with opening door of not less than 16 SWG thick, (l) Analog ammeter & voltmeter (m) 20A DP, MCB, 10kA, \\"C\\" Curve (Panel drawing must be got approved from Engineer-in-charge before finalisation). Size:- (0.45m x 0.40 m x 0.20m) (LxWxD)
2Supply, installation, connections, testing and commissioning of sequential timer panel for automatic operation of three AC units with manual provision and settable / adjustable time slot comprising following components etc. complete as required. TIMER PANEL FOR THREE AC (a) Suitable size sheet steel enclosure of 2/1.6 mm thick duly powder coated painting with IP-42 protection, (b) 40 A DP MCB, 10kA, \\"C\\"-Curve - 1 nos., RYB Indicating Lamps, 22.5 mm Dia LED Type -1 nos., 2A SP, MCB 10kA , \\"C\\"-Curve -3 nos. AC3 Type category 2 Pole power contactor ML-3 type - 02 nos., (c) Analog GIC type Quartz Timer 240 VAC - 24 hour - 2 no., (d)2A SP, MCB, \\"C\\" Curve (e) LED type ON indication lamp, (f) Illuminated type ON-OFF push button, (g) Auto - Manual Selector / Toggle switch, 2 no. (h) Aux Contactor for NO + NC - 02 nos. (i) SMC / DMC Connector with nuts & bolts as required, (j) Internal copper wiring with not less than 4.0 sqmm copper wire, (k) CRCA Powder coated enclosre with opening door of not less than 16 SWG thick, (l) Analog ammeter & voltmeter (m) 20A DP, MCB, 10kA, \\"C\\" Curve (Panel drawing must be got approved from Engineer-in-charge before finalisation). Size:- (0.45m x 0.40 m x 0.20m) (LxWxD)
3Supply, installation, connections, testing and commissioning of sequential timer panel for automatic operation of four AC units with manual provision and settable / adjustable time slot comprising following components etc. complete as required. TIMER PANEL FOR FOUR AC (a) Suitable size sheet steel enclosure of 2/1.6 mm thick duly powder coated painting with IP-42 protection, (b) 40 A DP MCB, 10kA, \\"C\\"-Curve - 1 nos., RYB Indicating Lamps, 22.5 mm Dia LED Type -1 nos., 2A SP, MCB 10kA , \\"C\\"-Curve -3 nos. AC3 Type category 2 Pole power contactor ML-3 type - 02 nos., (c) Analog GIC type Quartz Timer 240 VAC - 24 hour - 2 no., (d) 2A SP, MCB, \\"C\\" Curve (e) LED type ON indication lamp, (f) Illuminated type ON-OFF push button, (g) Auto - Manual Selector / Toggle switch, 02 nos. (h) Aux Contactor for NO + NC - 02 nos. (i) SMC / DMC Connector with nuts & bolts as required, (j) Internal copper wiring with not less than 4.0 sqmm copper wire, (k) CRCA Powder coated enclosre with opening door of not less than 16 SWG thick, (l) Analog ammeter & voltmeter (m) 20A DP, MCB, 10kA, \\"C\\" Curve (Panel drawing must be got approved from Engineer-in-charge before finalisation). Size:- (0.45m x 0.40 m x 0.20m) (LxWxD)
4commissioning of sequential timer panel for automatic operation of five AC units with manual provision and settable / adjustable time slot comprising following components etc. complete as required. TIMER PANEL FOR FIVE AC (a) Suitable size sheet steel enclosure of 2/1.6 mm thick duly powder coated painting with IP-42 protection, (b) 40 A DP MCB, 10kA, \\"C\\"-Curve - 1 nos., RYB Indicating Lamps, 22.5 mm Dia LED Type -1 nos., 2A SP, MCB 10kA , \\"C\\"-Curve -3 nos. AC3 Type category 3 Pole power contactor ML-3 type - 02 nos., (c) Analog GIC type Quartz Timer 240 VAC - 24 hour - 3 no., (d) 2A SP, MCB, \\"C\\" Curve (e) LED type ON indication lamp, (f) Illuminated type ON-OFF push button, (g) Auto - Manual Selector / Toggle switch, 02 nos. (h) Aux Contactor for NO + NC - 02 nos. (i) SMC / DMC Connector with nuts & bolts as required, (j) Internal copper wiring with not less than 4.0 sqmm copper wire, (k) CRCA Powder coated enclosre with opening door of not less than 16 SWG thick, (l) Analog ammeter & voltmeter (m) 20A DP, MCB, 10kA, \\"C\\" Curve (Panel drawing must be got approved from Engineer-in-charge before finalisation). Size:- (0.45m x 0.40m x 0.20m) (LxWxD)
5Supplying and Laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium armoured power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. (Acceptable make: Any reputed make)
64 Core x 16 sqmm armoured
7Providing and fixing following capacity TP&N MCCB inside with sheet steel enclosure including drilling holes, making connections, etc. as required.
840 A TP&N MCCB
9Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
103 X 4.0 sq. mm
11Supplying and fixing of following sizes of steel conduit along with accessories in surface/recessincluding painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
1225 mm Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57088750
AUTHORITY Government Departments
TENDER VALUE 7.45 Lakhs
LAST DATE 27-08-2026
Authority
Authority Name Indian Institute Of Technology
Work Description Tender for Supply Installation Testing and Commissioning of Auto-Sequential Timer Panel In Different Sites At Iit Delhi
Basic Detail
Tender No IITD/WORKS (SP-5379)/2026
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 19 Aug 2026
Submission Date 27 Aug 2026
Open Date 28 Aug 2026
Finance
Tender Value 7.45 Lakhs
Tender Fee Ref. Documents
EMD 14902
Exemption Not Available
Document List
BOQ_969612.xls
ceb2536c-e0b2-4186-8add-88b7f1c59928.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Aug 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_969612.xls

html

ceb2536c-e0b2-4186-8add-88b7f1c59928.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders