Housing Urban and Rular Development Local Bodies Closing in 7 days TDR #57088736

Tender For Running And Maintenance Of Dda Roshanara Club.Sub Head: Supply Replacement Testing And Commissioning Of Damaged/Outdated Feeder Pillar I/C Miscellaneous Electric Work At Dda Roshanara Club.

Issued by Local Bodies · Delhi, Delhi
Tender Value
22.10 Lakhs
Estimated cost
Bid Submission
27 Aug 2026
7 days left
EMD
44217
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Running And Maintenance Of Dda Roshanara Club.Sub Head: Supply Replacement Testing And Commissioning Of Damaged/Outdated Feeder Pillar I/C Miscellaneous Electric Work At Dda Roshanara Club.

BOQ

Name of Work:- Running and Maintenance of DDA Roshanara Club.Sub Head: Supply Replacement Testing and Commissioning of damaged/outdated feeder pillar i/c miscellaneous electric work at DDA Roshanara Club.
Sl. No. Item Description
1SRTC of indoor type cubical Feeder pillar(With 900 mm stand made out of 40x40x5 mm thick angle iron framework), fully compartmentalized made out of 2 mm thick CRCA Sheet having IP54 protection with canopy, pedestal mounted, suitable for use on 415V, 3 Phase, 4 wire, 50 HZ and complete with powder painted of approved shade, suitable size for accommodating the following component, including providing detachable gland plate of 3 mm thick MS sheet with knock outs of different size cables as required for incoming and outgoing cables entry, erected on cement concrete foundation, Brick work & plaster for covering all sides complete with painting with 2 or more coats of exterior paint after making the surface smooth with Birla putty, connections & interconnections, earthing etc complete as required. (for Gym, health club, swimming pool , admin building, badminton court, gust house and AC of club , card room , billyyard and bar )A) INCOMERi) 400 Amps FP MCCB (36KA) with thermomagnetic release for O/L+S/C-3 Nos. ii) calibrated Intelligent multifunction digital panel meters of class 0.5S accuracy with communication interface port RS 485 for recording Voltage (Between Phases and between each phase and neutral), Current (In each Phase and neutral), KVA, KW, KWhr, KVAR, pf, 64 samples/cycle, Total harmonic distortion, with suitable rating 250/5 amps CTs etc. complete with wiring , connections etc. iii) 6 Nos. Phase indication LED lamps with 2 Amp back up MCB, breaker 'ON/OFF' indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. B) BUSBARSi) 600 Amps TP&N Aluminum bus bars mounted on SMC supports.( Extension type )C) OUTGOINGSi) 125 Amps FP MCCB (25KA) with thermomagnetic release for O/L+S/C having overcurrent and short circuit protection- 8 Nos.
2SRTC of outdoor type cubical Feeder pillar(With 900 mm stand made out of 40x40x5 mm thick angle iron framework), fully compartmentalized made out of 2 mm thick CRCA Sheet having IP55 protection with canopy, pedestal mounted, suitable for use on 415V, 3 Phase, 4 wire, 50 HZ and complete with powder painted of approved shade, suitable size for accommodating the following component, including providing detachable gland plate of 3 mm thick MS sheet with knock outs of different size cables as required for incoming and outgoing cables entry, erected on cement concrete foundation, Brick work & plaster for covering all sides complete with painting with 2 or more coats of exterior paint after making the surface smooth with Birla putty, connections & interconnections, earthing etc complete as required. (for cricket ground high mast)A) INCOMERi) 400 Amps FP MCCB (36KA) with thermomagnetic release for O/L+S/C-1 Nos. ii) calibrated Intelligent multifunction digital panel meters of class 0.5S accuracy with communication interface port RS 485 for recording Voltage (Between Phases and between each phase and neutral), Current (In each Phase and neutral), KVA, KW, KWhr, KVAR, pf, 64 samples/cycle, Total harmonic distortion, with suitable rating 250/5 amps CTs etc. complete with wiring , connections etc. iii) 6 Nos. Phase indication LED lamps with 2 Amp back up MCB, breaker 'ON/OFF' indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. B) BUSBARSi) 600 Amps TP&N Aluminum bus bars mounted on SMC supports.( Extension type )C) OUTGOINGSi) 100 Amps FP MCCB (25KA) with thermomagnetic release for O/L+S/C having overcurrent and short circuit protection- 4 Nos.ii)ii) 16 AMP DP MCB,10KA -2 Nos.
3SRTC of outdoor type cubical Feeder pillar(With 900 mm stand made out of 40x40x5 mm thick angle iron framework), fully compartmentalized made out of 2 mm thick CRCA Sheet having IP55 protection with canopy, pedestal mounted, suitable for use on 415V, 3 Phase, 4 wire, 50 HZ and complete with powder painted of approved shade, suitable size for accommodating the following component, including providing detachable gland plate of 3 mm thick MS sheet with knock outs of different size cables as required for incoming and outgoing cables entry, erected on cement concrete foundation, Brick work & plaster for covering all sides complete with painting with 2 or more coats of exterior paint after making the surface smooth with Birla putty, connections & interconnections, earthing etc complete as required. (for jogger park )A) INCOMERi) 200 Amps FP MCCB (36KA) with thermomagnetic release for O/L+S/C-1 Nos. ii) calibrated Intelligent multifunction digital panel meters of class 0.5S accuracy with communication interface port RS 485 for recording Voltage (Between Phases and between each phase and neutral), Current (In each Phase and neutral), KVA, KW, KWhr, KVAR, pf, 64 samples/cycle, Total harmonic distortion, with suitable rating 200/5 amps CTs etc. complete with wiring , connections etc. iii) 6 Nos. Phase indication LED lamps with 2 Amp back up MCB, breaker 'ON/OFF' indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. B) BUSBARSi) 375 Amps TP&N Aluminum bus bars mounted on SMC supports.( Extension type )C) OUTGOINGSi) 63 Amps FP MCCB (25KA) with thermomagnetic release for O/L+S/C having overcurrent and short circuit protection- 2 No.iii) 32 AMP DP MCB,10KA -2 Nos.iii) 16 AMP SP MCB,10KA -1 Nos.
4SRTC of outdoor type cubical Feeder pillar(With 900 mm stand made out of 40x40x5 mm thick angle iron framework), fully compartmentalized made out of 2 mm thick CRCA Sheet having IP55 protection with canopy, pedestal mounted, suitable for use on 415V, 3 Phase, 4 wire, 50 HZ and complete with powder painted of approved shade, suitable size for accommodating the following component, including providing detachable gland plate of 3 mm thick MS sheet with knock outs of different size cables as required for incoming and outgoing cables entry, erected on cement concrete foundation, Brick work & plaster for covering all sides complete with painting with 2 or more coats of exterior paint after making the surface smooth with Birla putty, connections & interconnections, earthing etc complete as required. (for gym , sauna steam, change room of swimming pool )A) INCOMERi) 250 Amps FP MCCB (36KA) with thermomagnetic release for O/L+S/C-1 Nos. ii) calibrated Intelligent multifunction digital panel meters of class 0.5S accuracy with communication interface port RS 485 for recording Voltage (Between Phases and between each phase and neutral), Current (In each Phase and neutral), KVA, KW, KWhr, KVAR, pf, 64 samples/cycle, Total harmonic distortion, with suitable rating 400/5 amps CTs etc. complete with wiring , connections etc. iii) 6 Nos. Phase indication LED lamps with 2 Amp back up MCB, breaker 'ON/OFF' indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. B) BUSBARSi) 400 Amps TP&N Aluminum bus bars mounted on SMC supports.( Extension type )C) OUTGOINGSi) 100 Amps FP MCCB (25KA) with thermomagnetic release for O/L+S/C having overcurrent and short circuit protection- 4 No.ii) 63 AMP FP MCB,10KA -3 Nos.
5SRTC of outdoor type cubical Feeder pillar(With 900 mm stand made out of 40x40x5 mm thick angle iron framework), fully compartmentalized made out of 2 mm thick CRCA Sheet having IP54 protection with canopy, pedestal mounted, suitable for use on 415V, 3 Phase, 4 wire, 50 HZ and complete with powder painted of approved shade, suitable size for accommodating the following component, including providing detachable gland plate of 3 mm thick MS sheet with knock outs of different size cables as required for incoming and outgoing cables entry, erected on cement concrete foundation, Brick work & plaster for covering all sides complete with painting with 2 or more coats of exterior paint after making the surface smooth with Birla putty, connections & interconnections, earthing etc complete as required. (forswimming pool plant room)A) INCOMERi) 125 Amps FP MCCB (25KA) with thermomagnetic release for O/L+S/C-1 Nos. ii) calibrated Intelligent multifunction digital panel meters of class 0.5S accuracy with communication interface port RS 485 for recording Voltage (Between Phases and between each phase and neutral), Current (In each Phase and neutral), KVA, KW, KWhr, KVAR, pf, 64 samples/cycle, Total harmonic distortion, with suitable rating 150/5 amps CTs etc. complete with wiring , connections etc. iii) 6 Nos. Phase indication LED lamps with 2 Amp back up MCB, breaker 'ON/OFF' indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. B) BUSBARSi) 200 Amps TP&N Aluminum bus bars mounted on SMC supports.( Extension type )C) OUTGOINGSi) 7.5 HP DOL starter - 2 No.ii) 5 HP DOL starter - 1 No.iii) 40 AMP FP MCB,10KA -1 No.iv) 40 AMP DP MCB,10KA -2 No.
6SRTC of outdoor type cubical Feeder pillar(With 900 mm stand made out of 40x40x5 mm thick angle iron framework), fully compartmentalized made out of 2 mm thick CRCA Sheet having IP55 protection with canopy, pedestal mounted, suitable for use on 415V, 3 Phase, 4 wire, 50 HZ and complete with powder painted of approved shade, suitable size for accommodating the following component, including providing detachable gland plate of 3 mm thick MS sheet with knock outs of different size cables as required for incoming and outgoing cables entry, erected on cement concrete foundation, Brick work & plaster for covering all sides complete with painting with 2 or more coats of exterior paint after making the surface smooth with Birla putty, connections & interconnections, earthing etc complete as required. (for lawn tennis clay court)A) INCOMERi) 160 Amps FP MCCB (25KA) with thermomagnetic release for O/L+S/C-1 Nos. ii) calibrated Intelligent multifunction digital panel meters of class 0.5S accuracy with communication interface port RS 485 for recording Voltage (Between Phases and between each phase and neutral), Current (In each Phase and neutral), KVA, KW, KWhr, KVAR, pf, 64 samples/cycle, Total harmonic distortion, with suitable rating 160/5 amps CTs etc. complete with wiring , connections etc. iii) 6 Nos. Phase indication LED lamps with 2 Amp back up MCB, breaker 'ON/OFF' indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. B) BUSBARSi) 200 Amps TP&N Aluminum bus bars mounted on SMC supports.( Extension type )C) OUTGOINGSi) 63 AMP FP MCB,10KA -4 Nos.
7SRTC of outdoor type cubical Feeder pillar(With 900 mm stand made out of 40x40x5 mm thick angle iron framework), fully compartmentalized made out of 2 mm thick CRCA Sheet having IP55 protection with canopy, pedestal mounted, suitable for use on 415V, 3 Phase, 4 wire, 50 HZ and complete with powder painted of approved shade, suitable size for accommodating the following component, including providing detachable gland plate of 3 mm thick MS sheet with knock outs of different size cables as required for incoming and outgoing cables entry, erected on cement concrete foundation, Brick work & plaster for covering all sides complete with painting with 2 or more coats of exterior paint after making the surface smooth with Birla putty, connections & interconnections, earthing etc complete as required. (for TT panel )A) INCOMERi) 125 Amps FP MCCB (25KA) with thermomagnetic release for O/L+S/C-1 Nos. ii) calibrated Intelligent multifunction digital panel meters of class 0.5S accuracy with communication interface port RS 485 for recording Voltage (Between Phases and between each phase and neutral), Current (In each Phase and neutral), KVA, KW, KWhr, KVAR, pf, 64 samples/cycle, Total harmonic distortion, with suitable rating 63/5 amps CTs etc. complete with wiring , connections etc. iii) 6 Nos. Phase indication LED lamps with 2 Amp back up MCB, breaker 'ON/OFF' indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. B) BUSBARSi) 100 Amps TP&N Aluminum bus bars mounted on SMC supports.( Extension type )C) OUTGOINGSi) 63 AMP FP MCB,25KA -2 No.ii) 32 AMP FP MCB,10KA -1 No.
8SRTC of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730,hermetic compressor IS 10617, heat exchanger IS 11329,capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature).Inverter Type - Cooling onlya)1.5 TR with 5 Star BEE Rating
92.0 TR with 5 Star BEE Rating
10Earthing with GI earth pipe 4.5 meter long, 40mm dia including accessories, and providing masonry enlosure with cover plate having locking arrangment abd watering pipe etc with charcoal/coke and salt as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57088736
AUTHORITY Local Bodies
TENDER VALUE 22.10 Lakhs
LAST DATE 27-08-2026
Authority
Authority Name Delhi Development Authority
Work Description Tender for Running And Maintenance Of Dda Roshanara Club.Sub Head: Supply Replacement Testing And Commissioning Of Damaged/Outdated Feeder Pillar I/C Miscellaneous Electric Work At Dda Roshanara Club.
Basic Detail
Tender No 36/EE(E)/ELD-2/DDA/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 19 Aug 2026
Submission Date 27 Aug 2026
Open Date 28 Aug 2026
Finance
Tender Value 22.10 Lakhs
Tender Fee Ref. Documents
EMD 44217
Exemption Not Available
Document List
53ee1c85-b1a1-4899-8ec8-053bce563c41.html
BOQ_969665.xls
NIT36.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Aug 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

53ee1c85-b1a1-4899-8ec8-053bce563c41.html

xls

BOQ_969665.xls

pdf

NIT36.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders