Tender For Modernisation And Upgradation Of State Pesticide Testing Laboratory Parottukonam ,Thiruvananthapuram
Tender Value
68.29 Lakhs
Estimated cost
Bid Submission
29 Aug 2026
10 days left
EMD
50000
Bank guarantee accepted
Document Fee
2500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvananthapuram → Kerala
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Modernisation And Upgradation Of State Pesticide Testing Laboratory Parottukonam ,Thiruvananthapuram
BOQ
| Sl. No. | Item Description |
| 1 | CIVIL WORKS |
| 2 | OD272929/2025-2026Engaging Labour for cleaning inside of building and shifting the furniture andwaste,etc... |
| 3 | 15.7.4Demolishing brick work manually / by mechanical means including stacking ofserviceable material and disposal of unserviceable material within 50 metres lead asper direction of Engineer-in-Charge.In cement mortar |
| 4 | 15.3Demolishing R.C.C. work manually / by mechanical means including stacking ofsteel bars and disposal of unserviceable material with in 50 metres lead as perdirection of Engineer -in-Charge. |
| 5 | 15.23.1Dismantling tile work in floors and roofs laid in cement mortar including stackingmaterial within 50 metres lead.For thickness of tiles 10 mm to 25 mm |
| 6 | 15.2.1Demolishing cement concrete manually / by mechanical means including disposal ofmaterial within 50 metres lead as per direction of Engineer - in-Charge.Nominalconcrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 7 | 15.12.1Dismantling doors, windows and clerestory windows (steel or wood ) shutterincluding chowkhats, architrave, holdfasts etc. complete and stacking within 50metres lead:Of area 3 sq. metres and below |
| 8 | 14.1.1Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters andunder, including cutting the patch in proper shape, raking out joints and preparing andplastering the surface of the walls complete, including disposal of rubbish to thedumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : finesand) |
| 9 | 15.56Dismantling old plaster or skirting raking out joints and cleaning the surface forplaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 10 | 11.41.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS :15622, of approved make, in all colours and shades, laid on 20 mm thick cementmortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600 x 600 mm. |
| 11 | 11.40Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm ormore (thickness to be specified by the manufacturer) of Ist quality conforming to IS:15622 of approved make in all colours, shades, except white, Ivory, Grey Fume RedBrown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) includingpointing the joints with white cement and matching pigments etc., complete. |
| 12 | 8.31Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,including pointing in white cement mixed with pigment of matching shade complete. |
| 13 | 4.1.3Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarsesand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mmnominal size derived from natural sources) |
| 14 | 15.52Dismantling of flushing cistern of all types (C.I. / PVC/ Vitrious China) includingstacking of useful materials near the site and disposal of unserviceable materialswithin 50 metres lead |
| 15 | 13.88Removing white or colour wash by scrapping and sand papering and preparing thesurface smooth including necessary repairs to scratches etc. complete. |
| 16 | 13.43.1Applying one coat of water thinnable cement primer of approved brand andmanufacture on wall surface:Water thinnable cement primer |
| 17 | 13.98.1Wall painting with plastic emulsion paint of approved brand and manufacture to givean even shade:One or more coats on old work |
| 18 | 13.111.1Finishing walls with Acrylic Smooth exterior paint of required shade :Old work (Twoor more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface |
| 19 | 13.99.1Painting with synthetic enamel paint of approved brand and manufacture of requiredcolour to give an even shade :One or more coats on old work |
| 20 | OD273187/2025-2026Engaging Carpenter for minor maintanence work ,existing joineries etc.. |
| 21 | OD273211/2025-2026Engaging Mason for repairing work of existing Civil work. |
| 22 | 9.123Providing and fixing factory made door frame (single rebate) made out of single pieceextruded solid PVC foam profile with homogeneous fine cellular structure havingsmooth outer integral skin having 62 mm width & 32 mm thickness, frame willbe mitred & jointed with self driven self tapping screws of size 38 mm x 4 mm& PVC solvent cement, including fixing the frame to wall with suitable dia& length anchor fastener as per manufacturer's specification and directionof Engineer-in-charge. |
| 23 | 9.124.1Providing and fixing factory made 30 mm thick door shutter made of solid PVC foamprofile. The styles & rails shall be of size 75 mm x 30 mm having wall thickness5 mm. The styles, top & bottom rails shall have one side wall thickness of 15mm integrally extruded on the hinge side of the profile for better screw holdingpower. The styles and rails shall be reinforced with M.S. tubes of size 33 mm x 17 mm x 1 mm, painted with primer, all four corners of reinforcement to be welded orsealed. Solid PVC extruded bidding (Push fit type) will be set inside the styles and therails with a cavity, to receive single piece extruded 5 mm PVC sheet as panel. Thestyles and rails will be mitred cut and joint with the help of PVC solvent cement& self driven self tapping screws. Single piece extruded solid PVC lock rails ofsixe 100mm x 30 mm with wall thickness 5 mm & 15 mm integrally extruded inthe middle of the lock rail & fixed with styles with the help of PVC solventcement & self driven self tapping screws of size 100 mm x 8 mm complete asper manufacturer's specifications and direction of Engineer -in-charge.Nondecorative finish |
| 24 | 50.6.1.8Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x15cmor nearest available size confirming to IS 2185 part I of 1979 for super structure up tofloor two level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand etccomplete |
| 25 | OD276189/2025-2026Engaging Welder for dismantling the existing Net Grills in First Floor of Lab Block. |
| 26 | 5.9.5Centering and shuttering including strutting, etc. and removal of form for:Lintels,beams, plinth beams, girders bressumers and cantilevers |
| 27 | 5.2.2Reinforced cement concrete work in walls (any thickness), including attachedpilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. up tot floor five level excluding cost of centering,shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 gradedstone aggregate 20 mm nominal size derived from natural sources) |
| 28 | 5.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more |
| 29 | 13.7.212 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1cement : 4 fine sand) |
| 30 | 13.60.1Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 31 | 13.46.1Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Twoor more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exteriorprimer applied @ 2.20 kg/10 sqm) |
| 32 | 9.48.2Providing and fixing M.S. Grills of required pattern in frames of windows etc. withM.S. flats, square or round bars etc. including priming coat with approved steelprimer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc |
| 33 | 21.10Providing and fixing double glazed hermetically sealed glazing in aluminiumwindow, ventilators and partition etc. with 6 mm thick clear float glass both side,having 12 mm air gap, including providing EPDM gasket, perforated aluminiumspacers, desiccants, sealant (Both primary and secondary sealant ) etc. as perspecifications, drawings and direction of Engineer-in-Charge complete. |
| 34 | 9.147C.1Providing and fixing factory made uPVC white colour casement/ Casement cumfixed glazed door comprising of uPVC multi-chambered frame, sash and mullion(where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thickgalvanized mild steel section made from roll forming process of required length(shape & size according to uPVC profile), uPVC extruded glazing beads ofappropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hingesand one handle on each side of panels along with zinc plated mild steel multipoint locking having transmission gear, cylinder with keeps and one side key,G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessarystainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusionwelded at all corners, mullion (if required) shall be also fusion welded includingdrilling of holes for fixing hardware's and drainage of water etc. After fixingframe the gap between frame and adjacent finished wall shall be filled withweather proof silicon sealent over backer rod of required size and of approvedquality, all complete as per approved drawing & direction of Engineer-in-Charge.(Single / double glass panes and silicon sealent shall be paid separately).Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable.Casement door with3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm bothhaving wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing beadof appropriate dimension. (Area of door upto 2.00 sqm). |
| 35 | 15.57Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and falseceiling including disposal of unserviceable material and stacking of serviceablematerial with in 50 metres lead as directed by Engineer - in-Charge |
| 36 | 26.22.2Providing and fixing false ceiling at all heights with integral densified calcium silicatereinforced with fibre and natural filler false ceiling tiles of Size 595x595mm ofapproved texture, design and patterns as per CPWD Specification 2019, to be laid intrue horizontal level suspended on inter-locking metal T-Grid of hot dippedgalvanised iron section of 0.33mmthick (galvanized @ 120 grams per sqm includingboth sides)comprising of main-T runners of size 24x38 mm of length 3000 mm,cross- T of size 24x32 mm of length 1200 mm and secondaryintermediate cross-T of size24x32 mm of length 600mm to formgrid module of size 600 x 600 mm, suspendedfrom ceiling usinggalvanised mild steel items (galvanizing @ 80 grams per sqm) i.e.12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mmlength and L-shape level adjuster of size 76x25x25x1.6 mm fixed with grid and Zcleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierceinto 12x50mm or even bigger size dash fastener if require, fixed with Glavanised ironperimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed onperiphey wall / partition with the help of plastic rawl plugs at 450mm center to centerand 40 mm long dry wall S.S screws. The workshall be carried out as perspecifications, drawing and as per directionsof the Engineer-in-Charge.With 15 mmthick tegular/butt edged without perforation plain/designer lightweight calcium silicate Anti-Microbial Bio-Safe coated false ceiling tilesConfirming to JIS-Z2801 and ASTM G-21 |
| 37 | 13.80Providing and applying white cement based putty of average thickness 1 mm, ofapproved brand and manufacturer, over the plastered wall surface to prepare thesurface even and smooth complete. |
| 38 | 2.28.1Surface dressing of the ground including removing vegetation and in-equalities notexceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.Allkinds of soil |
| 39 | 4.1.8AProviding and laying in position cement concrete of specified grade excluding the costof centering and shuttering - All work up to plinth level: 1:4:8 (1 cement : 4manufactured sand derived from Recycled Concrete Aggregate(RCA) : 8 graded stone aggregate 40 mm nominal size Recycled Aggregate (RA) |
| 40 | PLUMBING WORKS |
| 41 | 17.2.1Providing and fixing white vitreous china pedestal type water closet (European typeW.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, includingflush pipe, with manually controlled device (handle lever), conforming to IS : 7231,with all fittings and fixtures complete, including cutting and making good the wallsand floors wherever required:W.C. pan with ISI marked white solid plastic seat andlid |
| 42 | 17.7.3Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever require:White Vitreous China Washbasin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps |
| 43 | 18.51.1 Providing and fixing C.P. brass long body bib cock of approved quality conforming toIS standards and weighing not less than 690 gms.15 mm nominal bore |
| 44 | 18.65Providing and fixing PTMT Soap Dish Holder having length of 138 mm, breadth 102mm, height of 75 mm with concealed fittings arrangements, weighing not less than106 gms. |
| 45 | 50.17.1.2Supplying and fixing CP Towel rod 45cm or nearest available length including cost ofmaterials and labour charges etc complete as per the direction of site Engineer-incharge. |
| 46 | 50.17.1.5Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make )including cost of materials and labour charges etc complete as per the direction of siteEngineer-in-charge. |
| 47 | 18.53.1Providing and fixing C.P. brass angle valve for basin mixer and geyser points ofapproved quality conforming to IS: 893115 mm nominal bore |
| 48 | 17.32.2Providing and fixing mirror of superior glass ( of approved quality) and of requiredshape and size with plastic moulded frame of approved make and shade with 6 mmthick hard board backing :Rectangular shape 453x357 mm |
| 49 | od37954/2024_2025Providing and fixing 150mm silt with CP gratings |
| 50 | 50.18.7.2.1Providing and fixing PVC pipes, fittings including fixing the pipe with claps at 1.00metre spacing. This includes jointing of pipes & fittings with one step PVCsolvent cement and testing of joints complete as per direction of Engineer-in-Charge20 mm dia 12Kgf/cm2 - Internal work - Exposed on wall |
| 51 | 50.18.7.4.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 32 mmdia 10Kgf/cm2- Internal work - Exposed on wall |
| 52 | 50.18.7.6.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 50 mmdia 10 Kfg/cm - Internal work- Exposed on wall |
| 53 | 50.18.8.9.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes with one step PVC solvent cement andtesting of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2 |
| 54 | OD273247/2025-2026Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVCsolvent cement - 50mm dia Bend |
| 55 | OD273250/2025-2026Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVCsolvent cement - 50mm dia Elbow |
| 56 | OD273253/2025-2026Providing and fixing PVC moulded fittings/acessories for rigid PVC pipes includingjointing with PVC solvent Cement 50x50x50 mm dia Tee |
| 57 | 50.18.9.22.4Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement- 110 mm dia Bend |
| 58 | 50.18.9.22.1Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Elbow |
| 59 | 50.18.9.22.5Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipesincluding jointing with PVC solvent cement 110x110x110 mm dia Tee |
| 60 | 50.18.9.21.4Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 75 mm dia Bend |
| 61 | 50.18.9.21Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 75 mm dia Elbow |
| 62 | OD273261/2025-202675 mm PVC Pipe for down water of Drain duct |
| 63 | OD273263/2025-2026Supplying and fixing 150 mm dia PVC pipe for Rain duct in the end portion of Roofof Including all Labour charges, cost of materials etc .Complete |
| 64 | OD273266/2025-2026Providing and fixing PVC moulded fittings/acessories for Rigid PVC pipes includingjointing with PVC Solvent cement-150 mm Bend |
| 65 | OD273267/2025-2026Providing and fixing PVC moulded fittings/acessories for Rigid PVC pipes includingjointing with PVC Solvent cement-150 dia mm Elbow |
| 66 | 18.32.1Constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar1:4 (1 cement : 4 coarse sand) for stop cock, with C.I. surface box 100x100x75 mm(inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2coarse sand: 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation,foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mmnominal size) and inside plastering with cement mortar 1:3(1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cementcomplete as per standard design:With common burnt clay F.P.S (non modular) bricksof class designation 7.5 |
| 67 | ELECTRICAL WORKS |
| 68 | 1.10.3Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVCconduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C |
| 69 | 1.23.5Supplying and fixing following piano type switch / socket on the existing switch box/cover including connections etc. as required.6 pin 15/16 amp socket outlet |
| 70 | 1.24.3Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.15/16 amp switch |
| 71 | 1.27.2Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 72 | 1.28.2Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.3 Module |
| 73 | 1.14.2Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLS PVC insulated copper conductor, single core cable in surface / recessedmedium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 74 | 90.11.1.18Supply and installation of sheet steel, phosphatised and painted, dust and verminproof enclosure of MCB DB including copper /brass bus bar, neutral link, earth busand DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitableanchor bolts or fixed in recess including cutting hole on the wall , making good thedamages, colour washing etc. as required4 way (8+12) - double cover TPN verticalDB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP42/43) |
| 75 | 2.10.3Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Double pole |
| 76 | 2.14.3Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milliamperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.63 amps |
| 77 | 1.5Wiring for light/ power plug with 2x4 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed steel conduit along with 1 No 4 sq. mm FRLSPVC insulated copper conductor single core cable for loop earthing as required. |
| 78 | 1.7.5Wiring for circuit/ sub main wiring along with earth wire with the following sizes ofFRLS PVCinsulated copper conductor, single core cable in surface/ recessed steel conduit asrequired2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 79 | 1.7.4Wiring for circuit/ sub main wiring along with earth wire with the following sizes ofFRLS PVCinsulated copper conductor, single core cable in surface/ recessed steel conduit asrequired2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 80 | 5.1Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, andproviding masonry enclosure with cover plate having locking arrangement andwatering pipe etc. (but without charcoal/ coke and salt ) as required. |
| 81 | 5.19Providing and fixing 4.00 mm dia copper wire on surface or in recess for loopearthing along with existing surface/ recessed conduit/ submain wiring/ cable asrequired. |
| 82 | OD273289/2025-2026Supply and fixing Ceiling fan including all materials and labour charges etc |
| 83 | OD273290/2025-2026Supplying and fixing angle batten with LED bulb and other accessories |
| 84 | 1.25Supplying and fixing two module stepped type electronic fan regulator on the existingmodular plate switch box including connections but excluding modular plate etc. as required. |
| 85 | 2.13.2Supplying and fixing following rating, four pole, 415 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.63amps |
| 86 | OD273292/2025-2026Supplying and fixing LED tube set and other accessories |
| 87 | 90.11.1.21Supply and installation of sheet steel, phosphatised and painted, dust and verminproof enclosure of MCB DB including copper /brass bus bar, neutral link, earth busand DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitableanchor bolts or fixed in recess including cutting hole on the wall , making good thedamages, colour washing etc. as required12 way (8+12) - double cover TPN verticalDB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP42/43) |
| 88 | 90.17.5.2Fabrication, supply, Installation testing & commissioning of Electrical controlpanel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCAsheet, compartmentalised with hinged lockable doors, dust and vermin proof, powdercoated of approved shade after 7 tank treatment process, cable alley, inter-connectionwith suitable size copper conductor cable/solid copper strip, having switchgears andaccessories, mountings and internal wiring, earth terminals, numbering etc. completein all respect, suitable for main fire pump, pressurisation pump & diesel pumpset complete as per CPWD specification with following in coming and Outgoings,suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protectionclass IP 42 as required :Incomings400A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V withselector switch Ammeter (0-400 A) with selector switch & CTs etc. LED type RYBphase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 500AOutgoings( Note : All outgoing feeders for pumps should have digital Ammeter with selectorswitches, and LED type ON, OFF, trip indicating lamps)Main Fire Pump200 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta startersuitable for 75 hp pump with overload protection, current sensing type single phasepreventer complete with all accessories and internal wiring required for automaticoperation, selector switch for local/remote, auto/manual/OFF operation.Jockey Pump100 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Deltastarter with overload protection, current sensing type single phase preventer completewith all accessories and internal wiring required for automatic operation, selectorswitch for local/remote, auto/manual/OFF operation.Diesel Engine Control Control for diesel engine comprising - Automatic/Manual selector switch & 3 attemptstarting device, timers and relays as required, push buttons, start/stop in manual modeIndicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine onindication Battery charger suitable for 12V/24 V DC with boost and trickle selectorswitch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays andaccessories for automatic operation of diesel engine System Controller Designing,Supply, Installation, Testing and commissioning of system controller to controloperation of main electric fire pump, diesel pump, Pressurization pump, Terracepump in sequence as per specification consisting of relays, timers. Sensors,annunciation window for fault indication, complete as per specifications. |
| 89 | OD277397/2025-2026Supplying and fixing 1 feet x 1 feet sq. light and other accessories |
| 90 | Supplying,erection ,testing and commissioning of 30 KVA DG set and other accessories of reputed company etc complete |
| 91 | Supplying and fixing of 100 amps change over switch and other accessories |
| 92 | Supplying 35 sq.mm aluminium armoured cable and giving connection |
| 93 | Supplying 35 sq.mm aluminium lug |
| 94 | Supplying 35 sq.mm aluminium gland |
| 95 | Supplying 65 inch smart TV.Rate shall including all materials and labour charges etc complete. |
| 96 | AIRCONDITIONING WORKS |
| 97 | OD85649/2026-2027Supplying and fixing 1.5 TR 3 Star Split AC with cordless remote and 4 kv stabilizerincluding all installation charges etc complet |
| 98 | Supplying and fixing 2 TR 3 Star Split AC with cordless remote and 4 kv stabilizerincluding all installation charges etc complete |
| 99 | Supplying and fixing 1 TR 3 Star Split AC with cordless remote and 4 kv stabilizerincluding all installation charges etc complete |
| 100 | Providing additional copper piping for erection of AC unit |
| 101 | Supply and fixing outdoor stand including all materials and labour charges etccomplete. |
| 102 | NETWORKING WORKS |
| 103 | Supplying and fixing Switch 24 Port 10/100 2 Port Giga Poe Rackmount including all materials and labour charges etc.uding all materials and labour charges etc. |
| 104 | Supplying and fixing CEILING MOUNT ACCESS POINT WIRELESS N300 2.4ghzincluding all materials and labour charges etc. |
| 105 | Supplying and fixing Floor Rack 9U including all materials and labour charges etc. |
| 106 | Supplying and fixing Patch Panel 24 Port Unloaded including all materials and labour charges etc. |
| 107 | Supplying and fixing Rj45 Connector Cat6 100n Box including all materials andlabour charges etc. |
| 108 | Supplying and fixing Power Distribution Unit 10 Socket 6a/13a Pdu (Support 27uRack Onwards) including all materials and labour charges etc. |
| 109 | Supplying and fixing network cooling Fan for all Rack Support including allmaterials and labour charges etc. |
| 110 | Supplying and fixing Cantilever Tray including all labour charges,cost of materilasetc complete. |
| 111 | Supplying and fixing Cable Manager 1U including all materials and labour chargesetc. |
| 112 | Supplying and fixing Hw Screw 10nos M6 Cage Nuts including all materials and labour charges etc. |
| 113 | Supplying and fixing Faceplate 1/2 Module including all materials and labour charges etc. |
| 114 | Supplying and fixing Metal Box 1 Module including all materials and labour charges etc. |
| 115 | Supplying and fixing Patch Cord Cat6 1m including all materials and labour charges etc. |
| 116 | Supplying and fixing Keystone Rj45 Cat6 including all materials and labour chargesetc. |
| 117 | Supplying and fixing Network Cable Cat6 including all materials and labourcharges etc. |
| 118 | Supplying and fixing Wire Tie 100/2nos + Tape 20nos including all materials andlabour charges etc. |
| 119 | Engaging labour for fixing Network Crimping+Rack Dressing +Commissioningincluding all materials and labour charges etc. |
| 120 | TELEPHONE CABLING WORKS |
| 121 | Supplying and drawing two pair telephone cable through 1'' case and caping and giving connection |
| 122 | Suppluing and fixing IO box set and giving connection |
| 123 | Supplying and fixing rose set box and giving connection |
| 124 | Suplying and fixing ordinary type telephone (BPL make) and other assessories |
| 125 | Supplying and fixing 4 channel EPABX including all materials and labour charges etc. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 19, 2026
11:30 IST
Tender Published
Tender notice published.
TodayAug 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysAug 31, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender