Tender For Special Repair To Md Accommodation Bldg No P-183 And Provision Of Exhaust Fan In Otm Accn And Ors Bathroom At Mariani Under Ge Jorhat.
Tender Value
43 Lakhs
Estimated cost
Bid Submission
15 Sep 2026
22 days left
EMD
86000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jorhat → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repair To Md Accommodation Bldg No P-183 And Provision Of Exhaust Fan In Otm Accn And Ors Bathroom At Mariani Under Ge Jorhat.
BOQ
| Sl. No. | Item Description |
| 1 | NOTE:-(i) The bidders/contractors are advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates.(ii) It is highlighted that the certain condition of General Condition of Contracts (IAFW-2249) has been modified as per direction of MoD i.e. inclusssion of Performance Security, deletion of Risk & Cost Provisions and increase in defect liability period all as per tender documents. The tenderers should keep in mind while quoting their offer. (iii) (Applicable for all items/parts):- The bidders/contractors are advised to refer Notes on BOQ/SCH'A' before entry/quoting the rates. |
| 2 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quions, arches, pillers etc complete all as specified and as directed. |
| 3 | Demolition of stone slab or tiles of any description or thickness in floors or aprons etc (laid bedded and pointed in any mortar) complete all as specified and as directed. |
| 4 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 5 | Dismantling plain or corrugated steel sheeting, any gauge, thickness including Nainital or similar pattern roof covering complete all as specified and as directed. |
| 6 | Dismantling timber boarding of any description fixed in any position secured with nails complete all as specified and as directed. |
| 7 | Dismantling Wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed. |
| 8 | Taking down wooden chowkats or frames with shutters with exceeding 1.50 Sqm but not exceeding 4.00 Sqm each (without taking of shutters from the frames) complete all as specified and as directed. |
| 9 | Taking down wooden chowkats or frames with shutters with not exceeding 1.50 Sqm each (without taking of shutters from the frames) complete all as specified and as directed. |
| 10 | Taking down cement plaster of any description built in cement mortar on brick or stone walls etc including racking out joints, hacking for Key, scrubbing down with water etc. complete all as specified and as directed. |
| 11 | Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams staircases, landing, chajjas and similar suspended work (reinforcement to be cut as required to facilitate demolition) complete all as specified and as directed. |
| 12 | Demolition of cement concrete of (unreinforced) any description and any position not otherwise specifically provided for and removal of rubbish from the site complete all as specified and as directed. |
| 13 | Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15cm thick (below or above ground level) and removal of rubbish from the site complete all as specified and as directed. |
| 14 | Dismantling timber scantling 40 Sqcm and over in section, in any position in unframed work and removing materials from site of work complete all as specified and as directed. |
| 15 | Dismantling wrought iron or mild steel work of any description not otherwise provided for and segregating serviceable materials and keeping for reuse at site and removing unserviceable materials from site of work complete all as specified and as directed. |
| 16 | Material and labour for providing cement concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concreting complete all as specified and as directed. |
| 17 | Material and labour for PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in surface channel, drains and like etc. complete all as specified and as directed. |
| 18 | Material and labour for plain cement concrete 1:2:4 type B0 (using 12.5mm graded crushed stone aggregate) as in roof kerb or mud stops, rounded or chamfered on edges complete all as specified and as directed. |
| 19 | Material and labour for PCC 1:2:4, type B-1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary use and waste of formwork complete all as specified and as directed. |
| 20 | Material and labour for reinforced cement concrete 1:2:4 type B1 (Nominal Mix) (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roof landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 21 | Material and labour for 75mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in plinth protection, paving, footpath etc and finished the surface even and smooth without using extra cement laid in panels including joint filled with sealing compound complete all as specified and as directed. |
| 22 | Material and labour for 25mm thick PCC (1:2:4) type B0 (using 12.5mm graded stone aggregate) as in sub base floring and finish the surface fair and even complete all as specified and as directed. |
| 23 | Material and labour required extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and as directed. |
| 24 | .-Ditto- all as per item No 22.00 above but add or deduct for each 25mm girth or part there of over or under 30cm and -ditto-. |
| 25 | Material and labour for brick work with sub class `B` bricks, old size, straight or curved on plan exceeding 6m mean radius built in cement mortar (1:4) complete all as specified and as directed. |
| 26 | Material and labour for flat formwork to soffits of suppended slab such as roof slabs, floor slab, landings and similar works, not exceeding 200mm thick (Horizontal or sloping) with rough finished flat surface complete all as specified and as directed. |
| 27 | Material and labour for well seasoned 2nd class hard wood timber in scantlings, clean sawn, timber framed and fixed complete all as specified and as directed. |
| 28 | Supply and fix 35mm thick 2nd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc. sizes of members of shutters as specified in SSR Part I, Sec-tion 8, clause 8.24 (a) complete all as specified and as directed. |
| 29 | Supply and fixing for 30mm thick factory made flush door shutters solid core construction with block board core and ply wood face panels commercial type on both faces complete all as specified and as directed. |
| 30 | Material and labour for mild steel TMT bars 10mm dia and over, cut to length bent to shape required, including cranking bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and as directed. |
| 31 | Material and labour for mild steel works as in bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed. |
| 32 | Supply and fix framed work such as grills, grating, etc, with ends of bars shouldered and/or riveted or forged into spikes ; window framed gurad bars ; barred iron doors, laddrs, framed balasters, walk ways, railings framed work of water and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed. |
| 33 | Material and labour for structural steel roof trusses ( framed), trussed, purlins, crane grantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe 410-W (Gde-E-250) quality-A complete all as specified and as directed. |
| 34 | Supply and fixing pressed steel frames of size 125 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc.,complete all as specified and as directed. |
| 35 | Supply and fixing pressed steel frames of size 105 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc.,complete all as specified and as directed. |
| 36 | Supply and fixing Anodised powder coated aluminium (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators etc with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed. |
| 37 | Supply and fixing Anodised powder coated aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21, 100mm long (2 no.) suitable handle (1 no.) complete all as specified and as directed. |
| 38 | Supply and fixing Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, as per requirement complete all as specified and as directed. |
| 39 | Supply and fixing 0.50mm thick pre-painted galvalume aluminium Zinc coating GI based corrugated / semi corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturer instruction complete all as specified and as directed. |
| 40 | Supply and fixing 0.50mm thick pre-painted galvalume aluminium Zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as per manufacturer instruction complete all as specified and as directed. |
| 41 | Supply and fixing 4mm thick HSPC(High Pressure Steam Cured) board as in false ceiling with powder coated GI/aluminium snap grid/section of size 600mm x 600mm fixed to wall hanging from soffits/trusses using adjustable supporting hanger comprising of 4mm dia MS rod or wire ‘J’ type hook, nuts, bolts, holding down clips with GI/aluminium section of size 36.5mm x 25mm x 1.4mm (main tee) and 23.5mm x 26.4mm x 1.4mm (cross tee) and wall angle of size 25mm x 25mm x 1.4mm complete all as specified and as directed. |
| 42 | Supply and fixing 4.00 mm thick Sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.50 Sqm in each pane complete all as specified and as directed. |
| 43 | Supply and fixing 4.00 mm thick frosted glass, ordinary quality and glazing in square not exceeding 0.5 sqm in each pane fixed to aluminium frame window/ventilator complete all as specified and as directed. |
| 44 | Supply and fix solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and as directed. |
| 45 | Supply and fix factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded decorative coloured laminates PVC `C` channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and decorative coloured laminates PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail or bottom rail ; panelling of decorative coloured laminates PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC laminated sheet beeding, and joined together with solvent cement, supplying and fixing in the frame at the site as per specification complete all as specified and as directed. |
| 46 | Supply and fixing 100mm size stainless steel butt hinges complete all as specified and as directed. |
| 47 | Supply and fixing 100mm size butt hinges, medium weight, cold rolled mild steel, complete all as specified and as directed. |
| 48 | Supply and fixing aluminium anodized, barrel tower bolts, 200mm long of extruded section complete all as specified and as directed. |
| 49 | Supply and fixing 150mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed. |
| 50 | Supply and fixing 300mm long aluminium alloy, anodized, sliding door bolt with hasp, staple(bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts,of extruded sections or cast aluminium alloy complete all as specified and as directed. |
| 51 | Supply and fixing for 300mm long mild steel ordinary rat tail rod pattern springs for doors including roller and roller plate complete all as specified and as directed. |
| 52 | Supply & fixing floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, overall length of cover plate 150mm complete all as specified and as directed. |
| 53 | Supply and fixing stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 and fixed with tinned tacks or galvanised wire staples complete all as specified and as directed. |
| 54 | Supply and fixing as in replacement 19/20mm dia mild steel chromium plated curtain rods with and including fixing socket and Bracket complete all as specified and as directed. |
| 55 | Supply and fixing 18/19mm thick MDF board, commercial type fixed with screws to timber frame work as in linings, panelling similar location cup board shutter, shelf, kitchen cabinets etc. complete all as specified and as directed. |
| 56 | Supply and fixing 12mm thick prelaminated particle board interior grade, prelaminated both side with decorative choice laminations fixed with screws to timber/Aluminium frame work complete all as specified and as directed. |
| 57 | Material and labour for non skid ceramic coloured tiles (Premium Quality) 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm coloured in floor etc set and jointed in neat cement slurry and pointed in white cement with pigment to match the shade of tiles over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed. |
| 58 | Material and labour for non skid ceramic coloured tiles (Premium Quality) 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm coloured in floor etc set and jointed in neat cement slurry and pointed in white cement with pigment to match the shade of tiles over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed. |
| 59 | .-Ditto- all as per item No 57.00 above but in skirting and dado laid over and including 10mm thick rendering in cement mortar (1:4) and -ditto-. |
| 60 | Material and labour for glazed ceramic coloured tiles (Premium Quality) of size 350x250x7mm/ 450x350x 7mm thick as on vertical surfaces, set and jointed in neat cement slurry and pointed in white cement with pigment to match with the shade of tiles laid over and including 10mm thick cement plaster in CM (1:4) complete all as specified and as directed. |
| 61 | Material and labour for precast Cement Concrete chequered tiles of size 200 x 200 x 25mm thick as in floor, set and jointed in neat cement slurry and pointed with cement laid over and including 20mm thick screed bed in CM (1:4) complete all as specified and as directed. |
| 62 | Material and labour for Granite work (of any type) 20 mm thick (table rubbed and polished) in slab, jambs,pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with granite shade complete all as specified and as directed. |
| 63 | Materials and labour for 15 mm thick rendering on brick work in cement mortar (1:6) and finished the surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 64 | Materials and labour for 15 mm thick rendering on fair faces of brick work or concrete surface in cement mortar (1:4) with using water proofing coumpound and as per manufacturer specification and finished the surfaces even and smooth without using extra cement complete all as specified and as directed.Note : WPC will be measured and paid separately. |
| 65 | Materials and labour for 5 mm thick rendering on concrete surfaces in ceiling in cement mortar (1:3) and finished the surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 66 | Supply only liquid integral water proofing compound conforming to IS-2645 complete all as specified and directed. |
| 67 | Materials and labour for roughening surfaces of old concrete floor by picking, sweeping, cleaning and washing down with water to remove dust and brushing with neat cement slurry with 3 kg cement per sqm complete all as specified and as directed. |
| 68 | Materials and labour for 15 mm thick screed bed on concrete surface in cement mortar (1:4) with using water proofing coumpound and as per manufacturer specification and finished the surfaces fair and even complete all as specified and as directed.Note : WPC will be measured and paid separately. |
| 69 | Material and labour for water proofing treatment to RCC roof slab incl parapet comprising with the following course of treatment/specifications from bottom to top :- (a) Applying bituminous primer @ 200-300 gm per Sqm over plastered surfaces of roof including parapet surfaces. (b) One layer of APP based polymeric membrane of approved manufacturer, 3mm thick, weight not less than 3.60 kgs per sqm, reinforced with non woven polyester fabric or weight not less than 150 grm per sqm. Polymeric membrane shall taken to a height 60 cm (minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. Note: (i) Laying of APP based polymeric membrane shall be done by torch on method or as per manufacturers instructions. (ii) A minimum overlap of 100mm and 75mm should be made in the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as manufacturers instructions. (c) Applying two coats of bituminous aluminum paint on top of APP membrane. |
| 70 | Material and labour for preparation of old plastered surfaces by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coats of cement base paint on walls complete all as specified and as directed. |
| 71 | Materials and labour for preparation of old plastered surfaces of wall and Finishing walls with distempering with 1st quality acrylic washable distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification with two coats of distemper including priming coat over and including 1mm thick wall care putty after complete removal of existing treatment on walls complete all as specified and as directed. |
| 72 | Materials and labour for preparation of old plastered surfaces of walls after complete removal of existing treatment and applying Acrylic Smooth exterior paint (Weather Coat) 1st quality of required shade (Two coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and as directed. |
| 73 | Materials and labour for preparation of newly plastered surfaces of wall and Finishing walls with distempering with 1st quality acrylic washable distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification with two coats of distemper including priming coat over and including 1mm thick wall care putty complete all as specified and as directed. |
| 74 | Materials and labour for preparation of newly plastered surfaces of ceiling and Finishing walls with distempering with 1st quality acrylic washable distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification with two coats of distemper including priming coat complete all as specified and as directed. |
| 75 | Material and labour for applying two coats of cement base paint over a coat of alkali resistant primer including preparation of newly plastered surfaces of wall complete all as specified and as directed. |
| 76 | Material and labour for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 77 | Material and labour for preparation of old steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 78 | Material and labour for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 79 | Taking up or down steel tubing 20 mm bore and connections including cleaning for refixing or removal to store complete all as specified and directed. |
| 80 | Taking up or down steel tubing 15 mm bore and connections including cleaning for refixing or removal to store complete all as specified and directed. |
| 81 | Supply and fixing CPVC pipes 20 mm outer diameter of SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors, complete all as specified and as directed. |
| 82 | Supply and fixing CPVC pipes 16 mm outer diameter of SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors, complete all as specified and as directed. |
| 83 | Supply and fixing as in replacement 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall with suitable size of MS flat iron clamp complete all as specified and as directed. |
| 84 | Supply and fixing as in replacement 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall with suitable size of MS flat iron clamp complete all as specified and as directed. |
| 85 | Supply and fixing 110 mm bore PVC (SWR) bends any radius with oval access door complete all as specified and directed. |
| 86 | Supply and fixing 75 mm bore PVC (SWR) bends any radius with oval access door complete all as specified and directed. |
| 87 | Supply and fixing 110mm bore PVC (SWR) junction single, (Single T) equal or unequal, with oval access door complete all as specified and as directed. |
| 88 | Supply and fixing 75mm bore PVC (SWR) junction single, (Single T) equal or unequal, with oval access door complete all as specified and as directed. |
| 89 | Supply and fixing 110 mm bore PVC (SWR) vent cowl complete all as specified and as directed. |
| 90 | Supply and fixing 75 mm bore PVC (SWR) vent cowl complete all as specified and as directed. |
| 91 | Supply and fixing 75mm dia, PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed. |
| 92 | Supply, hoisting and fixing in proper position ISI marked multi-layer rotational moulded polyethylene water storage tank (cylindrical vertical with closed top), of capacity 500 litres with and including 20mm bore PTMT float and ball valve set including providing necessary connections after dismantling existing PVC tank complete all as specified and as directed. |
| 93 | Supply and fixing as in replacement vitreous China white wash down water closet pan (pedestal pattern) with ‘P’ or ‘S’ trap, front or back inlet, fixing bolts, with white PVC seat cover, jet spray and providing 32 mm dia PVC flush pipe and making all necessary connections complete as specified and as directed. |
| 94 | Supply and fixing as in replacement vitreoues china WHB, white, flat back, of size 550X400mm including CP brackets, CP waste coupling 32 mm bore, PVC waste pipe 32mm dia with and including 15mm bore PVC connection pipe 450mm long with PTMT nuts at both ends complete all as specified and as directed. |
| 95 | Supply and fixing as in replacement looking mirror of size 600mm x 450mm x 5mm thick bevelled edge of selected quality glass, decorative type mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. |
| 96 | Supply and fixing as in replacement Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long fixed with screws complete all as specified and as directed. |
| 97 | Supply and fixing as in replacement 10 litre capacity low level PVC flushing cistern (White colour), syphonic action type, with inlet, ball valve, float, handle, fixed with cast iron bracket (of suitable size) and providing 32 mm dia PVC flush pipe and making all necessary connections complete all as specified and as directed. |
| 98 | Supply and fixing as in replacement 15mm bore Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and as directed. |
| 99 | Supply and fixing as in replacement 15mm bore fancy type bib taps cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed to pipe complete all as specified and as directed. |
| 100 | Supply and fixing as in replacement for 15mm bore stop valve, brass fancy type chromium plated, screwed down high pressure with crutch or butter fly handle screwed both ends fixed to GI pipe complete all as specified and as directed. |
| 101 | Supply and fixing as in replacement 15mm bore fancy type angular stop cock made of brass chromium plated screwed both ends for pipe with crutch handle, screwed down, screwed for iron pipe complete all as specified and as directed. |
| 102 | Supply and fixing as in replacement 15mm bore Chromium Plated pillar tap fancy type cast copper alloy, with capstan heads screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for pipe complete all as specified and as directed. |
| 103 | Supply and fixing as in replacement 125mm dia chromium plated shower rose with revolving joints fixed to 240mm long chromium plated shower arm (Light weight) round shape with wall flange complete all as specified and as directed. |
| 104 | Supply and fixing as in replacement Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and as directed. |
| 105 | Supply and fixing as in replacement soap dish holder brass chromium plated of approximate size 200x 200x90mm fixed to plugs with chromium plated brass screws complete all as specified and as directed. |
| 106 | Supply and fixing as in replacement tubular towel rail brass chromium plated, 20mm dia, D type, 60cm long fixed with two plugs (gutties) of 2nd class hard wood embedded in CM 1:3 with screws complete all as specified and as directed. |
| 107 | Supply and fixing as in replacement stainless steel (conforming to AISI-304 grade) kitchen sink with drain board of overall size 915mm x 460mm and bowl size 410mm x 352mmx 178mm depth or equivalent made of 1mm thick stainless steel sheet with 32mm bore CP waste coupling, 32mm bore PVC waste pipe(heavy duty) 90 cm long, 15mm dia 450mm long PTMT connection pipe and bedded in cement mortar and fixed on CP cantilever brackets, complete all as specified and as directed. |
| 108 | Supply and fixing as in replacement stainless steel (conforming to AISI-304 grade) plate rack of overall size 610mm x 610mm x 254mm or equivalent made of 0.60mm thick stainless steel sheet fixed on CP cantilever brackets, complete all as specified and as directed |
| 109 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed. |
| 110 | Material and labour for (concealed Type) point wiring including necessary chase cutting of wall for one light/fan/call bell point with 1.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts grade controlled by one way switch including 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including PVC conduit medium grade with all accessories and sunk modular GI box for mounting of fittings like switch, socket and fan regulator and making good the disturbed surfaces as per the existing complete all as specified and as directed by the Engr-in-Charge.Note: A. Red colored cable shall be used for live connection; black colored cable shall be used for neutral connection and green colored cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.B. The Rate of point wiring includes the following: - (i) Copper standard wire. (ii) PVC conduit with accessories. (iii) Chase cutting. |
| 111 | . -Ditto- all as per item No 109.00 here-in-before but for 3 pin 6 amps switch socket combination on the same board with 1.5 Sqmm cable and -ditto-. |
| 112 | . -Ditto- all as per item No 109.00 here-in-before but for 3 pin 6 amps switch socket combination on the independent board with 1.5 Sqmm cable and -ditto-. |
| 113 | . -Ditto- all as per item No 109.00 here-in-before but for one 6 pin multi, Modular socket outlet, 6/16 Amps, independent, with single core multi strand insulated unsheathed copper conductor 4.00 Sqmm FRLSH of size including single core multi strand unsheathed copper conductor 4.00 Sqmm FRLSH for earth continuity and connecting to common earth dolly and -ditto-. |
| 114 | Supply and fixing Metal flush box modular for 3 module complete all as specified and as directed. |
| 115 | Supply and fixing Metal flush box modular for 6 module complete all as specified and as directed. |
| 116 | Supply and fixing Metal flush box modular for 8 module complete all as specified and as directed. |
| 117 | Supply and fixing White cover plate with frame (both inner plate & outer plate cover),modular for 3 module complete all as specified and as directed. |
| 118 | Supply and fixing White cover plate with frame (both inner plate & outer plate cover),modular for 6 module complete all as specified and as directed. |
| 119 | Supply and fixing White cover plate with frame (both inner plate & outer plate cover),modular for 8 module complete all as specified and as directed. |
| 120 | Supply and fixing Modular type shuttered socket outlet 2/3 pin, 6 Amps, 230 volt, 2 Module complete all as specified and as directed. |
| 121 | Supply and fixing Modular type shuttered socket outlet 2/3 pin, 6/16 Amps, 230 volt, 2 Module complete all as specified and as directed. |
| 122 | Supply and fixing Modular switch single pole one way 6 Amps, 230 volt, 1 Module complete all as specified and as directed. |
| 123 | Supply and fixing Modular switch single pole one way 16 Amps, 230 volt, 1 Module complete all as specified and as directed. |
| 124 | Supply and fixing Piano switch flush button single pole one way 5/6 Amps, 240 volt complete all as specified and as directed. |
| 125 | Supply and fixing Modular type 5 step fan regulator 120 watt step type, AC 220 Volt, 2 Module complete all as specified and as directed. |
| 126 | Supply and fixing ceiling rose surface Bakelite three terminal complete all as specified and as directed. |
| 127 | Supply and fixing Exhaust fan steel body AC single phase 230 V of size 300 mm sweep with blades, frame & louvers including necessary hole for insertion of exhaust fan all as specified and directed.Note:– (i)The item rate is inclusive of making holes or making existing opening suitable for the installation of exhaust fan as per site condition all as specified and directed by Engr-in-chrg.(ii) The louvers for the exhaust fan shall be made of GI sheet suitable and properly fixed to the opening. |
| 128 | Supply and fixing as in replacement MCB DB TPN 4 ways double door with MCB TPN incommer including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and as directed.Note:- MCB TPN, MCB SPN and MCB SP shall be measured and paid seperately under respective item. |
| 129 | Supply and fixing as in replacement sheet metal enclosure single pole and neutral with two pin & earth plug with socket complete with one single pole MCB 20 Amps, SP, 240 Volts `C’ series complete all as specified and as directed. |
| 130 | Supply and fixing MCB TPN, 240 Volts, of 100 amps current rating, 10 KA breaking capacity ‘C' series complete all as specified and as directed. |
| 131 | Supply and fixing as in replacement MCB SPN, 240 Volts, of 32 amps current rating, 10 KA breaking capacity ‘C' series complete all as specified and as directed. |
| 132 | Supply and fixing as in replacement MCB SP, 240 Volts, of 6-32 amps current rating, 10 KA breaking capacity ‘C' series complete all as specified and as directed. |
| 133 | Supply and fixing sub-main wiring with PVC insulated & unsheathed two run of 6 Sqmm single core multi stranded copper conductor cable (FRLSH), 1100 Volt grade alongwith one run of 6 Sqmm PVC insulated & unsheathed copper conductor cable (FRLSH), 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through 20 mm conduit/ Casing Caping with all accessories and PVC rectangular boxes for mounting switch socket and fan regulator etc including taking down old sub-main wiring complete all as specified and as directed.Note : Three runs of 6 Sqmm cable and conduit shall be measured as one unit. |
| 134 | Supply and fixing sub-main wiring with PVC insulated & unsheathed two run of 4 Sqmm single core multi stranded copper conductor cable (FRLSH), 1100 Volt grade alongwith one run of 4 Sqmm PVC insulated & unsheathed copper conductor cable (FRLSH), 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through 20 mm conduit/ Casing Caping with all accessories and PVC rectangular boxes for mounting switch socket and fan regulator etc including taking down old sub-main wiring complete all as specified and as directed. complete all as specified and as directed.Note : Three runs of 4 Sqmm cable and conduit shall be measured as one unit. |
| 135 | Supply and fixing as in replacement LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 136 | Supply and fixing as in replacement LED mirror lights fitting 1x 10 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 137 | Supply and fixing as in replacement Compact street lighting luminaires with deep drawn housing for single 35 Watt LED, 5700K with toughened glass protection, pressure die cast aluminium housing IP66,with epoxy white powder coated and fixing bracket made of 32mm bore galvanised iron light grade pipe made to shape having overall length 1.2 mtr,fixed over the vertical wall through two numbers mild steel clamp of 25mm width, 3mm thick MS flat strip and four Nos nuts, bolts & washers of 12mm dia, 150mm long grouted into wall complete all as specified and as directed. |
| 138 | Materials and labour as in replacement for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised wire of 4mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 15mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed. |
| 139 | Supply and laying GI tubing 40mm bore light grade with fittings laid in trenches or for road crossing for protection of LT underground cables including taking up old unserviceable pipe complete all as specified and as directed. |
| 140 | Labour only for boring of hole under roads with mechanical arrangement upto 50 mm dia without disturbing the top surface of the road for passing the cable across the road complete all as specified and as directed. |
| 141 | Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 70 Sqmm 4 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc. and replaement of old unserviceable cable complete all as specified and as directed. |
| 142 | Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m in depth for foundations or for shafts, wells, cesspits, manholes, pier holes etc. not exceeding 10Sqm on plan and not exceeding 1.50m in depth and getting out in soft/loose soil complete all as specified and as directed. |
| 143 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm on soft/loose soil complete all as specified and as directed. |
| 144 | Removing excavated materials not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. |
| 145 | Material and labour for sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 cm in depth after laying the Cable) and consolidated (punned) upto 18 cm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only shall be measured and paid for. |
| 146 | Material and labour for Brick with subclass 'B' bricks in cable protection, laying with built in each other complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 18, 2019
11:30 IST
Tender Published
Tender notice published.
CompletedSep 15, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 22 daysSep 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 28 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender