Tender For Special Repair To Building No P-68 At Mh K Tee.
Tender Value
30.18 Lakhs
Estimated cost
Bid Submission
08 Sep 2026
15 days left
EMD
60360
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Nagpur → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repair To Building No P-68 At Mh K Tee.
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of Stone slabs & tiles of any description or thickness in floors, aprons etc. Laid, bedded & pointed in any mortar complete all as specified and directed. |
| 2 | S&F pre-polished granite 20mm thick fixed on platform/shelves/steps/cill over 20mm thick screed bed in cement mortar 1:4 including necessary moulding etc complete all as directed. |
| 3 | M&L Machine cut kota stone slab flooring 20-25mm thick over 15mm thick screed in CM(1:4) laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete, all as specified and directed. |
| 4 | S&F Pressed steel frame for doors of size 105 x 60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc including one coat of priming complete. |
| 5 | S&F Pressed steel frame for doors of size 125 x 60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc including one coat of priming complete all as specified and directed. |
| 6 | M&L PCC (1:3:6) type C-0 using 12.5 mm graded stone aggregate as in filling of pressed steel frame complete all as specified and directed. |
| 7 | Taking down door / window frame with shutter (without taking of shutter from the frame) area n. exc 1.50 sqm complete all as specified and directed. |
| 8 | Taking down door / window frame with shutter (without taking of shutter from the frame) area exc 1.50 sqm but not exc 4 sqm complete all as specified and directed. |
| 9 | S&F 30 mm thick flush shutters solid core construction with block board core and plywood face panels commercial type on both sides complete all as specified and directed. |
| 10 | Factory made solid panel PVC door shutter30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. but wire gauzed i.e. panel will be of wire gauze in lieu of single side prelam PVC sheet panel. The wire gauze shall be wrapped on an additional square 8mm M.S. Solid tube and this tube shall be welded to M.S.tubes. The wire gauge shall be stretched to tighten firmly |
| 11 | Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling& fixing in opening as per specification & drawing but wood grain printed PVC sheet used instead of Plain colour PVC sheet & edges will be painted tomatch with printed sheet complete all as spd and directed. |
| 12 | S&F factory made solid PVC moulded door shutter, 28 to 30mm thick (stiles), with 4mm thick moulded laminated PVC Sheet on the front face & 4mm plain colour PVC sheet on back face, with wood free EPS supplying & fixing in frame at site as per specification & drawing complete all as specified and directed. |
| 13 | S&F Butt hinges medium weight cold rolled stainless steel 100mm size complete all as spd and directed. |
| 14 | Supply & fixing 150mm Aluminium barrel tower bolts, fixed complete all as specified and as directed |
| 15 | Supply & fixing 150 mm Aluminium pressed handles fixed complete all as specified and directed. |
| 16 | S&F 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixibng bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as directed. |
| 17 | S&F 250 mm long Brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed. |
| 18 | S & F powder coating aluminium frame for doors, windows , ventilators with one or more rebates incl joining cleat for fixing etc. complete all as specified and directed. (thickness or powder coating not less than 50 micron) |
| 19 | Supply and fixing factory made uPVC white colour Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multi chambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge. (Glass or wiremesh shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 20 | S&F powder coated aluminium ventilator louvers type section aluminium sections weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc louvers after open use in ventilator in order to allow air or light in while keeping sun in or moisture out complete all as specified and directed.(thickness or powder coating not less than 50 micron) Note-(i) Glass and other filling material in panels shall be measured and paid seperately |
| 21 | Material & labour for preparation of new wooden surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 22 | Material & labour for preparation of old wooden surface of any description over 10cm width or girth and applying one coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 23 | M&L for preparation of old painted surfaces of steel and iron work of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint over a coat of redoxide on new surfaces in any tint complete all as specified. |
| 24 | M&L for preparation of new untreated surfaces of steel and iron work of any description over 10 cm width or girth not otherwise described and applying two coat of synthetic enamel paint over a coat of redoxide on new surfaces in any tint complete all as specified. |
| 25 | Hacking out old broken glass (any thickness size and quality and description) from wooden/steel/aluminium frames glazed with putty or fixed with beads etc complete all as specified and directed. |
| 26 | S&F 4.8 mm thick glass, ordinary quality and glazing with oil putty/wooden beads in square exceeding 0.5 square metre in each pane complete. |
| 27 | S&F 4 mm thick figured (frosted) glass, ordinary quality and glazing with oil putty/wooden beads in square not exceeding 0.5 square metre in each pane complete. |
| 28 | S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. |
| 29 | Dismantling floor, hearth or wall tiling including cement mortar beddeing (but not backing), removing serviceable tiles to store and debris complete all as specified and as directed. |
| 30 | Materials and labour for light shade doubled charge Vitrified Ceramic tiles light shade 10 mm thick (square/rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neatcement slurry and pointed in white or coloured cement to match over 15mm thick screed bed or bedding layer in cement mortar 1:4 (including bodder tile) complete all as specified and as directed. |
| 31 | Materials and labour for light shade double charge vitrified ceramic tiles 10mm thick (square/rectangular), polished, area of each tiles exc 0.42 sqm but not exc 1.00 Sqm as in vertical surfaces, set and jointed in neat cement slurry and pointed in white or coloured cement to match and incl.10mm thick backing coat in CM 1:3 finished even and fair complete all as specified. |
| 32 | M&L for coloured joints free non skid ceramic tiles, 6 to7 mm thick, edgeless , area of each tile exc 0.11 sqm but n. exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in colored cement over and incl 15 mm thick screed bed or bedding layers of cement mortar 1:4 to match Shade, pattern, laying etc of tiles as directed at site complete all as specified and directed. |
| 33 | Material & labour for glazed ceramic coloured tiles 300mm x 450mm, on vertical surface such as skirtings/dados set and jointed in neat cement slurry and pointed in coloured cement to match and incl.10mm thick backing coat in CM 1:3 finished even and fair complete all as specified. |
| 34 | M & L for coloured non skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding. 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed with white or coloured cement to match over and including 15 mm thick screed bed of cement mortar (1:6) etc complete all as specified and as directed. |
| 35 | M & L for coloured non skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding. 0.38 sqm, in vertical/dados etc. set and jointed in neat cement slurry and pointed with white or coloured cement to match over and including 10 mm thick screed bed of cement mortar (1:3) etc complete all as specified and as directed. |
| 36 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as spd and directed. |
| 37 | S&F Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks & similar work conforming to Fe 290-0 Gde E-165 complete all as specified and directed. |
| 38 | Demolition of brick work, built in cement mortar or cement lime mortar including all quoins, pillars etc. and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 50m as complete all as specified and directed. |
| 39 | M&L for brick with fly ash brick old size straight of curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and as directed. |
| 40 | All as per item No 39.00 above but half brick wall in CM 1:4 complete all as specified and directed. |
| 41 | Taking down cement Plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc., including removal of debris, complete all as specified and as directed. |
| 42 | M&L Rendering 10 mm thick on fair faces of brick work or concrete surfaces with CM 1:6 on internal walls finished even and smooth (without using extra cement) complete all as specified and directed. |
| 43 | Material & labour for Rendering 15 mm thick on brick or concrete surfaces in CM 1:4 external wall using water proofing liquid compound as per manufacturer instructions, and finished fair and even complete all specified and directed.(WPC shall be measured and paid separately.) |
| 44 | Supply only liquid water proofing compound complete all as specified and directed. |
| 45 | M&L rendering 10mm thick in cement plaster 1:3 on ceiling surface finished even and fair without using extra cement Complete all as specified and directed. |
| 46 | M & L for prepartion of new plastered surface of wall and applying two coats of oil bound distemper over a coat of Primer over a coats of wall care putty complete all as specified and directed. |
| 47 | Material and labour for complete removal of Existing Treatment and applying two coats of oil bound distemper over a coat of cement Primer and wall care putty complete all as specified and directed.Note:- Scrapping and painting to be executed by mechanical means through authorized applicator of approved make. |
| 48 | M&L for preparion of new plastered surfaces on wall including brooming down or steel wire brushing ,scraping down moulds , washing down and applying two coats of acrylic emulsion weather proof paint apex of Asian 1st quality over a coat of acrylic primer complete all as specified and directed. |
| 49 | Material and labour for complete removal of Existing Treatment and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over Existing surfaces including preparation of surfaces complete all as specified and directed Note:- Painting to be executed by mechanical means through authorized applicator of approved make. |
| 50 | M&L for preparation of new plastered surfaces and applying three coats of white wash on ceilings complete all as specified and directed |
| 51 | Material and labour for applying two coats of white wash on undecorated ceiling surfaces complete all as specified and directed. |
| 52 | M & L for GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste complete all as specified and directed. |
| 53 | M & L for Dubbing out average 15mm thick on irregular face of walls cement plaster in CM 1:4 (when specifically ordered in writing) complete all as specified and directed. |
| 54 | Taking up or down steel tubing 15 mm bore and connection complete all as specified and directed. |
| 55 | Taking up or down steel tubing 20 mm bore and connection complete all as specified and directed. |
| 56 | Supplying and laying of CPVC pipes 16 mm bore SDR 11 & Plain CPVC SDR 11 fittings in trenches and including taking up or down steel tubing and connection complete all as specified. |
| 57 | Supplying and laying of CPVC pipes 20 mm bore SDR 11 & Plain CPVC SDR 11 fittings in trenches and including taking up or down steel tubing and connection complete all as specified. |
| 58 | S & F Brass Elbow 16 mm for CPVC pipes complete all as specified and directed. |
| 59 | S & F Brass Elbow 20 mm for CPVC pipes complete all as specified and directed. |
| 60 | S & F Brass Tee 16 mm for CPVC pipes complete all as specified and directed. |
| 61 | S & F Brass Tee 20 mm for CPVC pipes complete all as specified and directed. |
| 62 | S & F Brass Union 16 mm for CPVC pipes complete all as specified and directed. |
| 63 | S & F Brass Union 20 mm for CPVC pipes complete all as specified and directed. |
| 64 | S & F Brass Ball Valve 16 mm for CPVC pipes complete all as specified and directed. |
| 65 | S & F Brass Ball Valve 20 mm for CPVC pipes complete all as specified and directed. |
| 66 | Supply & fixed in repairs vitreous china wash down water closet (pedestal pattern) 'P' or 'S' trap including jointing including plastic water closet seat cover, closed pattern with flat bottom and cover and mild steel CP or aluminimised hinging device,complete all as specified and directed. |
| 67 | S & F in repairs vitreous china white squatting pan \\"Orissa Pattern\\" size 580x440mm, with integrated foot rest (excluding flushing sistern, flush pipe etc) including making good to floor complete, all as specified and directed. |
| 68 | S&F Chromium plated toilet paper holder fixed to wall with plugs and brass chromium plated screws. complete all as specified and directed. |
| 69 | S & F 32 mm dia PVC waste pipe fixed in repairs complete all as specified and directed. |
| 70 | S&F in repairs shower rose brass cromium plated with swivel joints of size 75 mm dia cast copper alloy CP, fancy type with CP neck 6\\" long made to shape complete all as spd and directed. |
| 71 | S&F sinks with drainage board made of stainless steel 1.00mm thick in kitchen with plugs, washers and waste, incl bedding in cement mortar on wall incl fixing cantilever brackets and connecting union to pipe overall size 914 mm x460 mmx203mm , bowl size 405 mm x354 mmx203 mm complete all as specified and directed. |
| 72 | S&F kitchen rack plate made of stainless steel 1.00mm thick in kitchen with screws, incl complete all accessories overall size 24\\" x 30\\" x 10 \\" complete all as specified and directed. |
| 73 | S & Ffor 15mm dia CP wall mixer 3 in 1 for mixing hot and cold with L bend (provision for over head shower) screwd down for iron pipe complete all as specified and directed. |
| 74 | S&F central hole basin mixer(hot & cold) complete all as spd and directed. |
| 75 | S&F CP Sink with mixture with regular spout hot and cold arrangement long shank suitable for GI tubing complete all as specified and directed. |
| 76 | S & F 15 mm bore CP nozzle for RO connection complete complete all as spd and directed. |
| 77 | S & F Floor door stopper of aluminium alloy body and tongue, anodized, with hand drawn steel spring fixed in door, overall length of cover plate 150 mm complete all as specified and directed. |
| 78 | S&F in repair Vitreous China wash basin, white,with padestal flat back, size 540x400mm excluding ditto but including brackets and padestal etc all as specified and directed. |
| 79 | S & F in repairs 10 ltr cap PVC valve less symphonic action type flushing cistern low level, white with inlet ball valve float and handle including bracket etc complete all as specified. |
| 80 | S&F in repair bib tap 15 mm dia cast copper alloy with crutch or butter fly handle screwd for iron pipe or for brass ferrule and fixed complete all as specified. |
| 81 | S & F in repair PVC connection 15 mm dia, 450 mm long including PTMT check nut complete all as specified and directed. |
| 82 | S&F in repairs stop valve/angle cock 15 mm dia cast copper alloy high pressure with crutch or butter fly handle screwd for iron pipe or union and fixed. Chromium plated fancy type. complete all as specified and directed. |
| 83 | S&F in repairs 2-way bib cock with flange 15 mm dia cast copper alloy high pressure with crutch or butter fly handle screwd for iron pipe or union and fixed. Chromium plated fancy type, complete all as specified and directed. |
| 84 | S & F in repair health faucet of 15 mm bore brass cromium plated including PVC pipe to connection GI tubing 15 mm bore all complete all as specified and directed. |
| 85 | S & F in repair jet spray (butterfly) with 1.5 mtrs tube with complete all accessories complete all as specified and directed. |
| 86 | S &F Tubular towel rail, 20mm dia, D type, 60cm long between flanges of brass Chromium plated fixed with and including Chromium plated brass screws and wooden/plastic cleats complete all as specifed and directed. |
| 87 | S&F in repairs towel rack complete all as specified and directed. |
| 88 | S& F for Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms)Towel ring complete all as specified and directed. |
| 89 | S&F in repair PVC (SWR) gully trap 125/110 mm , setting and jointing with solvent cement complete all as specified and directed. |
| 90 | M&L for 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 91 | S & F in repair 110 mm bore PVC (SWR) pipe, single socketed in any length with rubber ring joints, fixed to walls/floor with stack clamp every one mtr apart complete all as specified and as directed. |
| 92 | S&F in repair CP grating doom with waste hole of size 125mm dia complete all as specifed and directed complete all as specifed and directed. |
| 93 | S & F in repair 75 mm bore PVC (SWR) pipe, single socketed in any length with rubber ring joints, fixed to walls/floor with stack clamp every one mtr apart complete all as specified and as directed. |
| 94 | S&F in repair PVC (SWR) Bends any radius for 110 mm bore complete all as specified and directed. |
| 95 | S&F in repair PVC (SWR) Bends any radius for 75 mm bore complete all as specified and directed. |
| 96 | S&F PVC (SWR) bends any radius provided with access door of 110mm dia complete all as spd and directed. |
| 97 | S&F PVC (SWR) bends any radius provided with access door of 75 mm dia complete all as spd and directed. |
| 98 | S&F PVC (SWR) branch pieces, single (equal or unequal) ordinary or inverted (spigot or socket type) or with paralled branches of 110mm bore with access door complete all as spd and directed. |
| 99 | S&F PVC (SWR) branch pieces, single (equal or unequal) ordinary or inverted (spigot or socket type) or with paralled branches of 75 mm bore with access door complete all as spd and directed. |
| 100 | S&F PVC (SWR) vent cowl of 110 mm dia complete all as spd and directed. |
| 101 | Dismantling water tank of capacity exc 500 ltr & not exc 1000 ltrs and removing to store of any description complete all as specified and directed |
| 102 | S & F 1000 ltrs capacity Rotational moulded multi layer polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in including 20mm bore PTMT float valve position including connections complete all as specified and directed. |
| 103 | M & L Gun-metal, globe or gate valves, 20mm bore with iron wheel head, screwed both ends for iron pipe and fixed as specified and directed. |
| 104 | S&F in repairs cabinet mirror 400x 500 mm for bathrooms complete all as specified and directed. |
| 105 | S&F in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with CP bracket guard & railing 60cm long complete all as specified and directed. |
| 106 | S&F in repair corner sheet glass shelf assemble consisting of 5.5mm thick sheet glass shelf with chromium plated bracket guard and railing complete all as specified |
| 107 | S&F in repairs CP soap dish with glass complete all accessories complete all as specified and directed. |
| 108 | S&F in repairs 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 109 | S&F in repair for curtain rails, Stainless steel, chromium plated with fixing brackets,stops rollers etc complete all as specified and directed. |
| 110 | Dismantling of asbestos cement (Corrugated, semi corrugated etc.) of any thickness including ridges hips valleys as in roof covering.complete all as specified and as directed. |
| 111 | M & L for 0.50 mm thick prepainted galvalume aluminium zinc coating G.I. based corrugated steel sheet of on colour having tensile strength of 550 MPA as in roof covering, fixed with and including self tapping screw complete all as per manufacturer instructions. |
| 112 | Demolition of RCC of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 113 | M&L Form work to chullah hoods, chajjas, troughs and similar items including edges and simillar work complete all as specified and directed. |
| 114 | M&L for providing RCC 1:1 1/2:3 type A-1 (nominal mix) (using 20 mm graded stone aggregate) as in chajja etc complete all as specified and directed. |
| 115 | M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending pirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed |
| 116 | Demolition of cement concrete any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 117 | M&L for Cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete /sub base complete all as specified and directed. |
| 118 | Material & labour 75 mm th PCC (1:3:6) Type C2 (using 40 mm graded stone aggregate), as in plinth protection and finishing surfaces even & smooth without using extra cement including mastic filling in the joint complete all as specified and directed. |
| 119 | Taking down existing water proofing treatment including PCC padding, mortar etc and disposal of rubbish outside of MD land and hacking for key, scrubbing down with water complete all as specified and directed. |
| 120 | M&L for provision of water proofing treatment by using APP torch on non woven polyster film reinforcement with 3 mm thick and weight not less than 3.00 kg/sq m over roof and vertical surfaces including preparation of surfaces and applying oil based bituminous primer coat @ 0.30 ltr per sqm on clean and dry surface and then providing APP membrane laid with 100 mm over lap on both sides all as per manufacturer's instructions including 15mm thick cement plaster in CM 1:4 with WPC and two coat of aluminium paint of 0.2Kg/Sqm over membrane complete all as specified and directed. |
| 121 | Dismantling boarding, any description, fixed in any position with Screw ,complete all as specified and directed. |
| 122 | S& F in repair 18 mm thick Alstone wood Polymer Composive Board ( WPC) in cupboard shutter and like with decorative on both side design fixed by drilling screws and brackets all as specified all as directed. |
| 123 | S&F in repair Continuous (piano) hinges, SS, bright finish with 30 mm width of flaps (When open), complete all as specified and directed. |
| 124 | S&F magnetic catcher of size 20mmx50mm suitable for cup board shutters complete all as specified and as directed. |
| 125 | S&F PVC bedding 18/19 mm width 0.8mm thick fixed with pvc edge bending tape with necessary glue complete all as spd & directed.Make : PROPOND |
| 126 | S & F in repairs 40 mm dia, cupboard Knobs fixed with nut, screws and washer of mild steel, bright finished complete all as spd and directed. |
| 127 | S&F stainless steel cabinet /drawer handle (Silver) including all accessories complete all as specified and as directed. |
| 128 | Demolition of cement concrete any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 129 | Material and labour for 100 mm thick plain cement concrete type C1, (1:3:6) (using 20mm graded stone aggregate) as in sub , etc finished surface even and fair without using extra cement, complete all as specified and directed. |
| 130 | Material and labour for pre-polished chequered tiles rubber pressed glossy finish (any colour) 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment over and including 20mm screed bedding in cement mortar (1:4) complete all as specified and directed. |
| 131 | M&L for providing cement concrete1:3:6 type C1 (20mm graded aggregate) as in copings,plinth courses including weathering,slightly rounded or chamfered angles and throating on edges complete all as specified and directed. |
| 132 | Taking down point wiring with aluminium conductor cable of light point fan & socket light & power complete including light fittings any type switches, sockets, ceiling rose, switch boards, bell/buzzer, bell push, tube light fitting, regulator etc, and making good to the disturbed surfaces of walls/ floor etc to macth with existing surfaces including white washing/colour washing/ distempering to match with existing wall/floor/ceiling finishes, complete all as specified and directed. |
| 133 | Taking down sheet metal enclosure, DB & MCBs main switch etc and making good distrubed sufaces to match with exisiting surfaces, complete all as specified and directed. |
| 134 | Taking down sub main wiring of any size/ capacity complete all as specified and making good disturbed sufaces to match with the existing surfaces, complete all as specified and directed. |
| 135 | Material and labour for point wiring 1100 volt grade single core FRLSH PVC insulated and unsheathed cable with multistranded copper conductor 1.50 sqmm drawn in and including electrical grade PVC conduit not less than 20mm dia with IS 9537 (Part-III) 1983 marked medium grade concealed on surface of wall/ceiling including FRLSH PVC insulated unsheathed earth wire with multistranded copper conductor of size 1.50 sqmm modular boxes sunk on wall for mounting of any type modular switches, switch sockets, fan regulator etc including modular cover with frame any size complete all as specified and making good disturbed surfaces for one light point controlled by one, one way switch, complete all as specifed and directed.Note :- Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate. All switches, fan, sockets, ceiling roses and holders shall be connected to common earth dolly. |
| 136 | All as per item Sl No 135 above but One ceiling/exhaust fan point controlled by oneway switch and regulator, complete all as specified and directed. |
| 137 | Ditto allAll as per item Sl No 135 above but One 3 pin 5 amp socket outlet point on the same board with other switches, complete all as specified and directed. |
| 138 | All as per item Sl No 135 above but One 3 pin 5 amps socket out let point on independent board, with 1.5 sqmm multi stranded cable and earth wire with copper conductor of size 1.5 sqmm complete all as specified and directed. |
| 139 | All as per item Sl No 135 above but One bell/buzzer point controlled by one bell push, complete all as specified and directed. |
| 140 | All as per item Sl No 135 above but wiring with 2.5 sqmm multi stranded cable and earth wire with copper conductor of size 2.5 sqmm for 15 amps power point, complete all as specified and directed. |
| 141 | All as per item Sl No 135 above but wiring with 4.0 sqmm multi stranded cable and earth wire with copper conductor of size 4.0 sqmm for 15 amps power point. complete all as specified and directed. |
| 142 | Material and labour for sub main wiring with two single core PVC FR LSH insulated unsheathed stranded copper conductor and earth wire 1100 volt grade and drawing into PVC conduit not less than 25 mm medium grade concealed in wall of the size 2x6.0 Sqmm with earth wire of 1x6.0 Sqmm, complete all as specified and directed.PVC Conduit.Note:- one run of 3 x6.0 sqmm and conduit will be measured as one unit. |
| 143 | Supply and fixing for switch modular type single pole one way 6 amp 1 module 250 volts AC suitable for modular switch boxes, complete all as specified and directed. |
| 144 | Supply and fixing for socket modular type single pole one way 6 amp 2 module 3 pin 250 volts AC suitable for modular switchboxes, complete all as specified and directed. |
| 145 | Supply and fixing for switch modular type single pole one way 6/16 amp 3 pin 250 volts AC suitable for modular switch boxes, complete all as specified and directed. |
| 146 | Supply and fixing for socket modular type single pole one way 6/16 amp 2/3 pin 2 module, 250 volts AC suitable for modular switch boxes, complete all as specified and directed |
| 147 | Supply & Fix modular motor starter 25A , 2 module for AC complete all as specified and directed. |
| 148 | Supply and fixing ceiling rose, surface type, three terminals 5 amps, complete all as specified and directed. |
| 149 | Supply and fixing Electric Bell Ding dong AC 230 volts, single phase, complete all as specified and directed. |
| 150 | Supply and fixing bell push switch modular type single pole one way 5 amp 240 volts, complete all as specified and directed. |
| 151 | Supply and fixing 0-4 step -2 module modular type electronic regulators for ceiling fan 1200/1400 mm sweep, 240 volts, 80 watts single pole complete all as specified and directed. |
| 152 | Supplying and fixing 20 Watt LED Tube light fittings complete with PVC body including tube rod, driver with not less than 2000 Lumen O/P and I/p rated voltage 220 to 240 V , 50 Hz, CCT 6500K, THD<10% connecting with 3 core 1 sqmm copper conductor cable complete all as specified and directed. |
| 153 | Supply and fix lamp holder insulated body with back plate for angle/ batten fitting complete all as specified and directed. |
| 154 | Supply and fixing LED light fitting 10W bulk head luminaries made of diecast PVC housing with lamp holders etc complete with all accessories and including connecting upto with twin core twisted flexible cable suitable size of 220 to 240V, 50Hz, THD<10%, lumen 100 lm /watt, 6500 K complete all as specified and directed. |
| 155 | Supplying and fixing 10 Watt LED Tube light fittings complete with pvc body including tube rod, driver with not less than 1000 Lumen O/P and I/p rated voltage 220 to 240 V , 50 Hz, CCT 6500K, THD<10% connecting with 3 core 1 sqmm copper conductor cable complete all as specified and directed. |
| 156 | Supply and fix building security light LED 35 W with Lumen O/P 3500 with driver with rated voltage 220 to 240 V, 50Hz, IP 66 including mounting GI (made out of light grade GI pipe of suitable dia) 0.8 m bent two shape including clamps nut bolts etc. complete all as specified and directed. |
| 157 | Supply and Fix ceiling fan 1200 mm sweep complete with 3 blades controllable by regulator min 225 CFM air delivery BEE 5 star rated copper wound Brushless Direct Current(BLDC) motor including all accessories like down rod, electronic circuit board complete all as specified and directed |
| 158 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. complete all as specified and directed |
| 159 | Supply and fixing Exhaust fan metallic body 300 mm sweep, 1400 RPM single phase, 3 blades 230 Volts, 50Hz, with nut and bolts, washers etc., and connecting up with twin core twisted flexible copper conductor cable of suitable size from fitting to ceiling rose, and making holes for exhaust fan in wall complete all as specified and directed.Note :- Wire mesh shall be fixed outside the opening to prevent insect/flies at no extra cost |
| 160 | Supply and fixing Exhaust fan PVC body 250 mm sweep, 1200 RPM single phase, 230 Volts, 50Hz, 5 blades with nut and bolts, washers etc., and connecting up with twin core twisted flexible copper conductor cable of suitable size from fitting to ceiling rose, and making holes in window frame of suitable size complete all as specified and directed. |
| 161 | Supply and fix sheet metal enclosure triple pole & neutral for 415 volts 4 way with 200 Amp rated bus bar flush /surface mounting double door including dummy plates wherever required complete all as specified and directed |
| 162 | Supply and fix MCB triple pole and neutral 415 volt 40 to 60 amps 10 KA complete all as specified and directed. |
| 163 | Supply and fix sheet metal enclosure single pole & neutral for 240 volts 12 way with 200 Amp rated bus bar flush /surface mounting, double door, complete all as specified and directed. |
| 164 | Supply and fix MCB single pole & neutral 240 volt 32 amps 10 KA, \\"C\\" curve complete all as specified and directed. |
| 165 | Supply and fix MCB single pole 240 volt 6 to 40 amps 10 KA, \\"C\\" curve complete all as specified and directed. |
| 166 | S&F in repairs energy meter boxes suitable to accommodate single phase energy meter with all connections made of metallic sheet and bakelite window complete all as specified and directed. |
| 167 | Earthing complete with galvanised steet earth plate electrode 600x600x6mm thick burried directly in ground (earth plate not less than 2.25mtr deep below normal ground level) with top edge of the plate not less then 1.50 mtr. below the normal ground level connected to galvanised earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washer of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point all as specified and testing on completion including the material and labour for :-(a) Excavation and earth work or drilling hole for electrode in any type of soil(b) PCC pit in cement concrete 1:2:4 TYPE B-1(c) Pre cast RCC cover with suitable handle 40mm thick in PCC 1:2:4 reinforced with welded steel wire fabric(d) Funnel with watering pipe of GI 20mm nominal bore light grade and copper lugs etc all as specified.(e) 15mm nominal bore meduim grade GI protec-tion pipe 7.50 metre long for protection of earthing lead.(f) Requisite quantity of charcoal and common salt(g) Connection to earthing test point and testing on completion. |
| 168 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in hard/dense soil for foundation of poles, structures, stay rods, laying of underground cable etc complete all as specified and directed |
| 169 | Returning, filling in soils including spreading, leveling, watering and well ramming in layers each not exceeding 25cm thick complete all as specified and directed |
| 170 | Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed |
| 171 | Supply and lay GI tubing 50 mm dia, light grade for cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete all as specified and directed |
| 172 | M&L XLPE insulated ,armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq mm 3.5 core complete all as specified and directed |
| 173 | S&F of HDPE double wall corrugated pipe confirming to IS -14930 Part with IP protection IP-67 having outer dia 50mm complete all as specified and directed |
| 174 | M & L for road/footpath cutting for laying of cable as repairing the same by using PCC 1:2:4 all as specified and as directed |
| 175 | Supply and lay pipe galvanized, “Medium class”, including fittings 50 mm (2”) dia. including Bends, increasing sockets/decreasing or double socket etc, complete all as specified and directed |
| 176 | Supply and lay pipe galvanized, “Medium class”, including fittings 25 mm (1”) dia. including Bends, increasing sockets/decreasing or double socket etc, complete all as specified and directed |
| 177 | S&F Gun metal gate valve with iron wheel head screwed both end of size 50mm dia for iron pipe and fixed complete all as specified and directed |
| 178 | S&F Gun metal gate valve with iron wheel head screwed both end of size 25mm dia for iron pipe and fixed complete all as specified and directed |
| 179 | Excavation in trenches for laying of cable trench, pole and stay foundation in any type of soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.50 mtr deep and getting out complete all as specified and directed |
| 180 | Returning filling in,including spreading,leveling watering and well ramming in layers not exceeding 25 cms thick. Complete all as specified and directed |
| 181 | Removing excavated materials to a distance not exceeding 50 Mtr & depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed |
| 182 | M&L for cutting cast iron/Galvanised Iron pipes and reducing to required length before laying or in position for insertion of new tees,branches, for upto 100 mm pipe etc complete all as specified and directed |
| 183 | Construction of stone masonry valve pit for Gate valve all as specified and as per drawing including plastering, PCC in foundation, Excavation and earth work in any type of soil, MS sheet cover 3mm thick sheet with locking arrangement painted with two coat of anti corossive paint over one coats of zinc chrome primer of 450X450X600mm (type 'B') for 50 mm valve complete all as specified and directed |
| 184 | NOTE:- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.) [(-) Rs. 68,165.73] Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysSep 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender