Defence Statutory Bodies & Commissions/Committees Closing in 17 days TDR #57086245

Tender For Provision Of Certain Sanction Works Of Electrical And Mechanical Works Under Ge (Af) Jamnagar No.2

Issued by Statutory Bodies & Commissions/Committees · Jamnagar, Gujarat
Tender Value
45 Lakhs
Estimated cost
Bid Submission
08 Sep 2026
17 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jamnagar → Gujarat
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Provision Of Certain Sanction Works Of Electrical And Mechanical Works Under Ge (Af) Jamnagar No.2- 1 Supply , Installation, Testing And Commissioning Of Factory Made Cpri Approved, Outdoor Type Amf Panel For Dg Set Of Capacity 320Kva Made Out Of 3.15Mm Thick Crca Sheet, 415Volts, 3 Phase, 50Hz Supply Mounted On And Including Ms Angle Section 50X50X5Mm Thick Ms Frame With Front And Back Openable, Double Door With Provision Of Locking Arrangement Dust Proof, Gasket, Tpn Busbar Aluminium Of Capacity 630Amp Bus Bar With Formica Sheet , Rubber Gasket, Wiring With Copper Wire And Lugs Shall Be Insulated With Colour Coated Heat Shrinkable Sleeves And Shall Be Mounted On Proper Insulator, Gland, Welding Hinges Of Dust Proof, Overall Power Coated Complete With All Following Items Mccb , Amf Controller, Battery Charger Etc., All As Specified And Directed & Including Excavation For Panel Board Installation And Pcc 1:4:8 And Pcc 1:3:6 For Foundation Work Complete With Dismantlimng Of Exsting Panel Board :- 2 (I) Mccb 4 Pole , 36 Ka, 630 Amps 415 Volts Extended Terminals, Fixed Setting Type -02 Nos (Ii) Spreader Terminal 630A (Set Of 8) - 04 Nos (Iii) 600A Fp Contactor( Mcx 45 ) (Mcx45) --02 Nos (Iv) Three Phase Mfm Meter - 01 Nos (V) Ryb Indicator Lamp - 02Nos (Vi) Green Indicator Lamp - 02 Nos (Vii) 600/5 Ring Type Cl-1 Va -15Ct --06 Nos (Viii) 6A Sp ,C Mcb -Lk -08 Nos (Ix) 10 A Dp C Mcb-Lk -03Nos (X) Selector Switch 4 P 2W 6A-02 Nos (Xi) E-Stop Push Button -L&T -01 Nos (Xi) Amf Controller -01 No (Xii) 8 Channel 1 C/O Relay Card 24 V Dc --01 No (Xiii) Battery Charger 24 V Dc 10 A-01 Nos (Xiv) Hooter -01 No (Xv) Auxilary Contactor 2 No+2 Nc (Mx0 22E) (Location - Filtration Plant Af-Ii Dg Set ) 3 Supply And Fix On Load Change Over Outdoor Type Switch 415 Volt In Sheet Metal Enclosure 4 Pole Of Caapcity 630 Amp Side Handle Operated Complete With Angle Iron Suitable For Fixing Arrangement Including Pcc Work As Required All As Per Directed. 4 All As Per Item No - 1 But Bus Bar Capacity 400 Amp Suitable For 160Kva Dg Set With Following Items:- 5 (I) Mccb 4 Pole , 36 Ka, 400 Amps 415 Volts Extended Terminals, Fixed Setting Type -02 Nos (Ii) Spreader Terminal 400 - 4 Pole (Set Of 8) - 04 Nos (Iii) 325A Fp Contactor( Mcx 41) --02 Nos (Iv) Three Phase Mfm Meter - 01 Nos (V) Ryb Indicator Lamp - 02Nos (Vi) Green Indicator Lamp - 02 Nos (Vii) 400/5 Ring Type Cl-1 Va -15Ct --06 Nos (Viii) 6A Sp ,C Mcb -Lk -08 Nos (Ix) 10 A Dp C Mcb-Lk -03Nos (X) Selector Switch 4 P 2W 6A-02 Nos (Xi) E-Stop Push Button -L&T -01 Nos (Xi) Amf Controller -01 Nos (Xii) 8 Channel 1 C/O Relay Card 24 V Dc - 01 No (Xiii) Battery Charger 24 V Dc 10 A-01 Nos (Xiv) Hooter -01 No (Xv) Auxilary Contactor 2 No+2 Nc (Mx0 22E) (Location - Main Stp Af-I Dg Set ) 6 Supply And Fix On Load Change Over Outdoor Type Switch 415 Volt In Sheet Metal Enclosure 4 Pole Of Caapcity 400 Amp Side Handle Operated Complete With Angle Iron Suitable For Fixing Arrangement Including Pcc Work As Required All As Per Directed. 7 All As Per Item No - 1 But Bus Bar Capacity 250 Amp Suitable For 125 Kva Dg Set With Following Items:- 8 (I) Mccb 4 Pole , 36 Ka, 250 Amps 415 Volts Extended Terminals, Fixed Setting Type -02 Nos (Ii) Spreader Terminal 4 Pole (Set Of 8) - 04 Nos (Iii) 255A Fp Contactor (Mcx34) --02 Nos (Iv) Three Phase Mfm Meter - 01 Nos (V) Ryb Indicator Lamp - 02Nos (Vi) Green Indicator Lamp - 02 Nos (Vii) 250/5 Din Type Cl-1 Va -5Ct --06 Nos (Viii) 6A Sp ,C Mcb -Lk -08 Nos (Ix) 10 A Dp C Mcb-Lk -03Nos (X) Selector Switch 4 P 2W 6A-02 Nos (Xi) E-Stop Push Button -L&T -01 Nos (Xi) Amf Controller -01 Nos (Xii) 8 Channel 1 C/O Relay Card 24 V Dc - 01 No (Xiii) Battery Charger 24 V Dc 10 A-01 Nos (Xiv) Hooter -01 No (Xv) Auxilary Contactor 2 No+2 Nc (Mx0 22E) (Location - Dsc Pump House Dg Set ) 9 Supply And Fix On Load Change Over Outdoor Type Switch 415 Volt In Sheet Metal Enclosure 4 Pole Of Caapcity 250 Amp Side Handle Operated Complete With Angle Iron Suitable For Fixing Arrangement Including Pcc Work As Required All As Per Directed. 10 All As Per Item No - 1 But Bus Bar Capacity 200 Amp Suitable For 100 Kva Dg Set With Following Items:- 11 (I) Mccb 4 Pole , 25 Ka,200 Amps 415 Volts -02 Nos (Ii) Spreader Terminal Dn1/Dn2 - 4 Pole (Set Of 8) - 04 Nos (Iii) 200Amp Fp Contactor (Mcx33) -02 Nos (Iv) Three Phase Mfm Meter - 01 Nos (V) Ryb Indicator Lamp - 02Nos (Vi) Green Indicator Lamp - 02 Nos (Vii) 200/5 Din Type Cl-1 Va -5Ct --06 Nos (Viii) 6A Sp ,C Mcb -Lk -08 Nos (Ix) 10 A Dp C Mcb-Lk -03Nos (X) Selector Switch 4 P 2W 6A-02 Nos (Xi) E-Stop Push Button -L&T -01 Nos (Xi) Amf Controller -01 Nos (Xii) 8 Channel 1 C/O Relay Card 24 V Dc - 01 No (Xiii) Battery Charger 24 V Dc 10 A-01 Nos (Xiv) Hooter -01 No (Xv) Auxilary Contactor 2 No+2 Nc (Mx0 22E) (Location - Map Pump House Dg Set ) 12 Supply And Fix On Load Change Over Outdoor Type Switch 415 Volt In Sheet Metal Enclosure 4 Pole Of Caapcity 200 Amp Side Handle Operated Complete With Angle Iron Suitable For Fixing Arrangement Including Pcc Work As Required All As Per Directed. 13 All As Per Item No - 1 But Bus Bar Capacity 160 Amp Suitable For 75 Kva Dg Set With Following Items:- 14 (I) Mccb 4 Pole , 25 Ka, 160 Amps 415 Volts -02 Nos (Ii) Spreader Terminal Dn1/Dn2 - 4 Pole (Set Of 8) - 04 Nos (Iii) 160Amp Fp Contactor (Mcx32) -02 Nos (Iv) Three Phase Mfm Meter - 01 Nos (V) Ryb Indicator Lamp - 02Nos (Vi) Green Indicator Lamp - 02 Nos (Vii) 150/5 Din Type Cl-1 Va -5Ct --06 Nos (Viii) 6A Sp ,C Mcb -Lk -08 Nos (Ix) 10 A Dp C Mcb-Lk -03Nos (X) Selector Switch 4 P 2W 6A-02 Nos (Xi) E-Stop Push Button -L&T -01 Nos (Xi) Amf Controller -01 Nos (Xii) 8 Channel 1 C/O Relay Card 24 V Dc - 01 No (Xiii) Battery Charger 24 V Dc 10 A-01 Nos (Xiv) Hooter -01 No (Xv) Auxilary Contactor 2 No+2 Nc (Mx0 22E) (Location - Ps No-Iii Dg Set ) 15 Supply And Fix On Load Change Over Outdoor Type Switch 415 Volt In Sheet Metal Enclosure 4 Pole Of Caapcity 125 Amp Side Handle Operated Complete With Angle Iron Suitable For Fixing Arrangement Including Pcc Work As Required All As Per Directed. 16 All As Per Item No - 1 But Bus Bar Capacity 125 Amp Suitable For 50 Kva Dg Set With Following Items:- 17 (I) Mccb 4 Pole , 25 Ka, 125 Amps 415 Volts -02 Nos (Ii) Spreader Terminal Dn1/Dn2 - 4 Pole (Set Of 8) - 04 Nos (Iii) 130Amp Fp Contactor (Mcx32) -02 Nos (Iv) Three Phase Mfm Meter - 01 Nos (V) Ryb Indicator Lamp - 02Nos (Vi) Green Indicator Lamp - 02 Nos (Vii) 150/5 Din Type Cl-1 Va -5Ct --06 Nos (Viii) 6A Sp ,C Mcb -Lk -08 Nos (Ix) 10 A Dp C Mcb-Lk -03Nos (X) Selector Switch 4 P 2W 6A-02 Nos (Xi) E-Stop Push Button -L&T -01 Nos (Xi) Amf Controller -01 Nos (Xii) 8 Channel 1 C/O Relay Card 24 V Dc - 01 No (Xiii) Battery Charger 24 V Dc 10 A-01 Nos (Xiv) Hooter -01 No (Xv) Auxilary Contactor 2 No+2 Nc (Mx0 22E) (Location - Main Power House Af-Ii ) 18 Supply And Fix On Load Change Over Outdoor Type Switch 415 Volt In Sheet Metal Enclosure 4 Pole Of Caapcity 63 Amp Side Handle Operated Complete With Angle Iron Suitable For Fixing Arrangement Including Pcc Work As Required All As Per Directed. 19 All As Per Item No - 1 But Bus Bar Capacity 100 Amp Suitable For 35 Kva Dg Set With Following Items:- 20 (I) Mccb 4 Pole , 25 Ka,100 Amps 415 Volts -02 Nos (Ii) Spreader Terminal Dn1/Dn2 - 4 Pole (Set Of 8) - 04 Nos (Iii) 80 Amp Fp Contactor (Mcx32) -02 Nos (Iv) Three Phase Mfm Meter - 01 Nos (V) Ryb Indicator Lamp - 02Nos (Vi) Green Indicator Lamp - 02 Nos (Vii) 100/5 Din Type Cl-1 Va -5Ct --06 Nos (Viii) 6A Sp ,C Mcb -Lk -08 Nos (Ix) 10 A Dp C Mcb-Lk -03Nos (X) Selector Switch 4 P 2W 6A-02 Nos (Xi) E-Stop Push Button -L&T -01 Nos (Xi) Amf Controller -01 Nos (Xii) 8 Channel 1 C/O Relay Card 24 V Dc - 01 No (Xiii) Battery Charger 24 V Dc 10 A-01 Nos (Xiv) Hooter -01 No (Xv) Auxilary Contactor 2 No+2 Nc (Mx0 22E) (Location - Ps - Ii ) 21 All As Per Item No - 1 But Bus Bar Capacity 100 Amp Suitable For 25 Kva Dg Set With Following Items:- 22 (I) Mccb 4 Pole , 25 Ka, 100Amps (Dn0 - 100C) 415 Volts -02 Nos (Ii) Spreader Terminal Dn1/Dn2 - 4 Pole (Set Of 8) - 04 Nos (Iii) 40 Amp Fp Contactor (Mcx 04) -02 Nos (Iv) Three Phase Mfm Meter - 01 Nos (V) Ryb Indicator Lamp - 02Nos (Vi) Green Indicator Lamp - 02 Nos (Vii) 40/5 Din Type Cl-1 Va -5Ct --06 Nos (Viii) 6A Sp ,C Mcb -Lk -08 Nos (Ix) 10 A Dp C Mcb-Lk -03Nos (X) Selector Switch 4 P 2W 6A-02 Nos (Xi) E-Stop Push Button -L&T -01 Nos (Xi) Amf Controller -01 Nos (Xii) 8 Channel 1 C/O Relay Card 24 V Dc - 01 No (Xiii) Battery Charger 24 V Dc 10 A-01 Nos (Xiv) Hooter -01 No (Xv) Auxilary Contactor 2 No+2 Nc (Mx0 22E) (Location - Ps-I ) 23 Supply & Lay Xlpe Insulated, Pvc Inner Sheathed, Armoured With Galvanised Steel Strip Or Wire, Heavy Duty, Lt Underground Cable Isi Marked With Aluminium Multistranded Conductor 1100 Volt Grade Of Size 150 Sqmm 3.5 Core Laid In Trenches / Duct Passing Through Pipe / Duct Or Fixed On Pole And Connecting And Testing Etc Including Taking Down Old Cable Complete All As Specified & Directed By Engr -In-Charge. 24 Supply & Lay Xlpe Insulated, Pvc Inner Sheathed, Armoured With Galvanised Steel Strip Or Wire, Heavy Duty, Lt Underground Cable Isi Marked With Aluminium Multistranded Conductor 1100 Volt Grade Of Size 120 Sqmm 3.5 Core Laid In Trenches / Duct Passing Through Pipe / Duct Or Fixed On Pole And Connecting And Testing Etc Including Taking Down Old Cable Complete All As Specified & Directed By Engr -In-Charge. 25 Supply & Lay Xlpe Insulated, Pvc Inner Sheathed, Armoured With Galvanised Steel Strip Or Wire, Heavy Duty, Lt Underground Cable Isi Marked With Aluminium Multistranded Conductor 1100 Volt Grade Of Size 95 Sqmm 3.5 Core Laid In Trenches / Duct Passing Through Pipe / Duct Or Fixed On Pole And Connecting And Testing Etc Including Taking Down Old Cable Complete All As Specified & Directed By Engr -In-Charge. 26 Supply & Lay Xlpe Insulated, Pvc Inner Sheathed, Armoured With Galvanised Steel Strip Or Wire, Heavy Duty, Lt Underground Cable Isi Marked With Aluminium Multistranded Conductor 1100 Volt Grade Of Size 70 Sqmm 3.5 Core Laid In Trenches / Duct Passing Through Pipe / Duct Or Fixed On Pole And Connecting And Testing Etc Including Taking Down Old Cable Complete All As Specified & Directed By Engr -In-Charge. 27 Supply & Lay Xlpe Insulated, Pvc Inner Sheathed, Armoured With Galvanised Steel Strip Or Wire, Heavy Duty, Lt Underground Cable Isi Marked With Aluminium Multistranded Conductor 1100 Volt Grade Of Size 50 Sqmm 3.5 Core Laid In Trenches / Duct Passing Through Pipe / Duct Or Fixed On Pole And Connecting And Testing Etc Including Taking Down Old Cable Complete All As Specified & Directed By Engr -In-Charge. 28 Earthing Complete With Galvanized Steel Earth Plate Electrode 60Cm X 60Cm X 6Mm Thick Buried Directly In Ground (Earth Pit Not Less Than 2.25 Mtrs Deep Below Ground Level) With Top Edge Of The Earth Plate At A Depth Of Not Less Than 1.5 Mtr Below Ground Level Connected To Galvanized Iron Strip 25 X 3 Mm As Earthing Lead By Means Of Bolts, Nuts And Washers Made Out Of Gi/Steel Earth Strip Protected By Gi Light Grade Pipe Of 40 Mm Dia And Connecting To Main Panel Board/Switch Board/Control Board All Shown In Electrical Plate No 3 Of Ssr Pt I Incl Pcc Chambers In 1:2:4 And Rcc Cover Slab With 8Mm Dia Ms Bars Reinforced At 10 Cm Center To Center Both Ways Incl Earth Work Like Excavation, Returning Filling Back Disposal Etc Complete. 29 Excavation In Trenches In Hard Dense Soil N.Exc 1.5 Mtr Wide & N.Exc 1.5Mtr In Depth And N. Exc. 10Sqm On Plan For Laying Pipe In Trenches And Getting Out Complete All As Specified And Directed. 30 Returning Filling In Trenches, Spreading, Levelling, Watering And Well Ramming In Layers N.Exc 25Cm In Hard Dense Soil Complete All As Specified And Directed. 31 Removing Of Surplus Soil To A Distance N.Exc 50 Mtr And Depositing Where Directed At A Level N.Exc 1.5 Mtr Above Starting Point Complete All As Specified And Directed. 32 M&L For Providing Dry River Sand As In Sand Cushioning 18Cm Before And 5 Cm After Laying Of Under Ground Electric Cable, Thickness Specified In Ssr Part -I, Including Punning Down Of Sand In Layer All As Specified And Directed By Engr-In-Charge. Note: For Measurement Purpose Punned Thickness Of Sand Only Will Be Considered. 33 Supply & Laying Isi Marked & Conforming To Is - 5820 - 1970 Unreinforced Precast Concrete Cable Cover Class Lv, Flat Of Size 250 Mm X 150 Mm X 40 Mm In Trenches As Protection To Lt Ug Cable All As Specified And Directed By Engr-In-Charge. 34 Material And Labour For Cross Arms, Bracings, Supports, Clamps And Back Plates Fabricated From Structural Steel Sections Including Nuts, Bolts, Washers, Welding, Bending Cold Or Hot, Drilling Holes For Bolts, In Any Shape Or Size As Indicated Or Directed And Inclusive Of One Primer Coat, One Under Coat And One Finishing Coat Of Paint Etc All Complete. 35 M & L For Pre-Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet 0.5Mm Of An Colour Having Tensile Strength Of 550Mpa As In Roof Covering/Cladding To Wall, Velley Gutter Fixed With Self Tapping Screws Completed All As Apecified And Directed. 36 Excavating In Post Holes (Or Similar Holes) Each N Exc 0.5 Cu. M, Getting Out In Any Type Of Soil, Returning, Filling In And Ramming Earth Or Broken Rubble Mixed With Earth Around, In Layers Not Exceeding 25 Cm Completed All As Apecified And Directed. 37 Supply & Fixing 5 Star Rated Electric Storage Water Heater (Vertical Type) 25 Ltr, 230 V, Ac, Single Phase Power Input 2000W,Standing Loss In Kwh 24 (Hours) 45 °C 0.511 Kwh With And Including Connecting Fastners Nuts Not Less Than 100 Mm With Suitable Nut, Bolt & Washers Grouted In Walls With Complete Masonary Work For Proper Mounting Of Geyser Fastning Bolts Etc As Directed As Site Reqmt And Making Necessary Inlet And Outlet Water Connection As Well As Electric Connection Including Testing On Load For Entire Satisfaction Of Engineer-In-Charge 38 M&L For Sub Main Wiring Using Pvc Insulated And Unsheathed Multistranded Frls Copper Conductor Cable Using Approved Colour Code As Per Is Drawing In And Incl Pvc Casing And Capping With All Accessories And Making Good Disturbed Surfaces Of Wall, Floor Or Ceiling With Plaster And Finishing The Surfaces With Distemper/White Washing/Colour Washing To Match With The Existing Surface Complete As Specified And As Directed By Engr-In-Charge Of The Following Sizes Of Cables. 39 Using Two Single Core Pvc Insulated Frls Cable 2.5 Sqmm Copper Conductor Multi Stranded And 1.5 Sqmm Copper Conductor Insulated Cable Using As Earth Wire Note :2 Runs Of 2.5Sqmm Copper Cable & 1 Run Of 2.5 Sqmm Copper Cable In And Including Pvc Casing And Capping Shall Be Measured As One Unit 40 S&F For Single Pole And Neutral Enclosure With Two Pin And Earth Plug And Socket Complete With A Single Pole Mcb 20 Amps Complete In Sheet Metal Enclosure Complete All As Specified And Directed. 41 M&L For Mcb Single Pole,5 To 30 Amp 240 Volt B Curve 10 Ka, Ip 20 Complete All As Specified And Directed. 42 Supply & Fixing Gi Pipe 15 Mm Bore Medium Grade With All Fitting Such As Unions, Tee, Nipple, Short Lengthand Socket For Connecting And Fixed Complete To Walls And Ceiling Or Laid In Floors Complete All As Specified And Directed. 43 Supply & Fixing Gi Pipe 20 Mm Bore Medium Grade With All Fitting Such As Unions, Tee, Nipple, Short Lengthand Socket For Connecting And Fixed Complete To Walls And Ceiling Or Laid In Floors Complete All As Specified And Directed. 44 S & F Pvc Connection Nylon Braided 15 Mm Size With Ptmt Nuts 450/600 Mm Long For Hot/Cold Water To And From Geyser Complete All As Specified And Directed. 45 S & F Stop Valve 15 Mm Bore Heavy Duty Fancy Type Chromium Plate With Long Sunk And Cup Connected In Wall Clamps As Per Site Reqmt For Cold Water Inlet & Hot Water Outlet Connection Complete All As Specified And Directed. 46 S & F Bib Cock 15 Mm Bore Heavy Duty Fancy Type Chromium Plate With Long Sunk And Cup Connected In Wall Clamps As Per Site Reqmt For Whb Purpose Complete All As Specified And Directed. 47 Supply And Fix In Repair 15 Mm Size Angular Cock, Cast Copper Alloy Chromium Plated, Screwed Down High Pressure With Capstan Head, Screwed Both Ends For Iron Pipe Or Unions, Complete All As Specified And Directed. 48 M & L For Cutting Hole Not Exceeding 150 Sqmm Into Through Brick Wall Built In Cement Mortar Or Stone Wall / Rcc Wall Built In Lime Mortar / Concrete For Passing Inlet Pipe Of Geyser Through Walls Or As Per Site Reqmt All As Directed Including Making Good The Disturbed Surfaces. 49 S & F Energy Efficient Bldc Ceiling Fan, 1200Mm Sweep Bee 5 Star Rated, Ac Single Phase, 230 Volts, 50 Hz, And Connecting Up Including Provision Of Three Core Flexible Copper Wire Of Size 1.5 Sqmm From Ceiling Rose To Ceiling Fan Complete In All Respect And All Accessories Complete All As Specified And Directed. 50 Supply And Fixing Exhaust Fans, Ac Single Phase, 230/240 Volts, 50 Hz, Metalic Body 300Mm Sweep, 1400 Rpm With Louvers, Fixing With 4 Nos Hold Fastener Nut And Bolt With Washer And Connecting With Flexible Pvc Insulated Multistranded Copper Conductor Cable Of Size 0.75 Sqmm From Ceiling Rose To Exhaust Fan Including Civil Work For Making Opening On Wall Of Suitable Size For Installation Of Exhaust Fan And Making Good Complete All As Specified And Directed. 51 Supply And Fixing Exhaust Fan, Pvc Body, Heavy Duty, Ac Single Phase, 230V Of Size 200/250Mm Sweep With, Blades, And Frame And Louvers Complete And Other Accessories Etc Complete All As Specified And Directed. 52 Supply And Fix Led Solar Post Top With Built In Solar Panel Led Light And Lithium Battery With Charge Controller And 2 Pir Sensors Wiyh 360 Degree Coverage Ip 65 Complete All As Specified And Directed. Make- Havells Cat Part No-Budz 1W 5700K Solar Bollard Light Or Equivalent Make As Mentioned In Appx B To Ps. 53 Supply And Fix Mano Led Post Top Ip65 Led Solar Post Top With Built-In Solar Panel, Led Light And Lithium Battery With Charge Controller And 2 Pir Sensors With 360º Coverage With Charge Controller And 2 Pir Sensors Wiyh 360 Degree Coverage Ip 65 Complete All As Specified And Directed. Make- Havells Cat Part No-Manor 20 W 5700 K Solar Post Top Or Equivalent Make As Mentioned In Appx B To Ps. Please Enable Macros To View Boq Information

BOQ

Name of Work:- PROVN OF CERTAIN SANCTION WORKS OF E/M WORKS UNDER GE (AF) JAMNAGAR NO.2
Sl. No. Item Description
1Supply , installation, testing and commissioning of factory made CPRI approved, outdoor type AMF PANEL FOR DG SET of capacity 320KVA made out of 3.15mm thick CRCA sheet, 415volts, 3 phase, 50Hz supply mounted on and including MS angle section 50x50x5mm thick MS frame with front and back openable, double door with provision of locking arrangement dust proof, gasket, TPN busbar aluminium of capacity 630Amp bus bar with formica sheet , rubber gasket, wiring with copper wire and lugs shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall power coated complete with all following items MCCB , AMF Controller, Battery charger etc., all as specified and directed & including excavation for panel board installation and PCC 1:4:8 and PCC 1:3:6 for foundation work complete with dismantlimng of exsting panel board :-
2(i) MCCB 4 Pole , 36 KA, 630 Amps 415 Volts extended terminals, fixed setting type -02 Nos (ii) spreader terminal 630A (set of 8) - 04 Nos (iii) 600A FP Contactor( MCX 45 ) (MCX45) --02 Nos (iv) Three Phase MFM Meter - 01 Nos (v) RYB Indicator Lamp - 02Nos (vi) Green Indicator Lamp - 02 Nos (vii) 600/5 Ring type CL-1 VA -15CT --06 Nos (viii) 6A SP ,C MCB -LK -08 Nos (ix) 10 A DP 'C' MCB-LK -03Nos (x) selector switch 4 P 2W 6A-02 Nos (xi) E-stop push button -L&T -01 nos (xi) AMF Controller -01 No (xii) 8 Channel 1 C/O Relay Card 24 V DC --01 No (xiii) Battery Charger 24 V DC 10 A-01 Nos (Xiv) Hooter -01 No (xv) Auxilary contactor 2 No+2 NC (MX0 22E) (Location - Filtration Plant AF-II DG set )
3Supply and fix ON LOAD change over outdoor type switch 415 volt in sheet metal enclosure 4 pole of caapcity 630 Amp side handle operated complete with angle iron suitable for fixing arrangement including PCC work as required all as per directed.
4All as per Item No - 1 but bus bar capacity 400 Amp suitable for 160KVA DG set with following items:-
5(i) MCCB 4 Pole , 36 KA, 400 Amps 415 Volts extended terminals, fixed setting type -02 Nos (ii) spreader terminal 400 - 4 pole (set of 8) - 04 Nos (iii) 325A FP Contactor( MCx 41) --02 Nos (iv) Three Phase MFM Meter - 01 Nos (v) RYB Indicator Lamp - 02Nos (vi) Green Indicator Lamp - 02 Nos (vii) 400/5 Ring type CL-1 VA -15CT --06 Nos (viii) 6A SP ,C MCB -LK -08 Nos (ix) 10 A DP 'C' MCB-LK -03Nos (x) selector switch 4 P 2W 6A-02 Nos (xi) E-stop push button -L&T -01 nos (xi) AMF Controller -01 NOs (xii) 8 Channel 1 C/O Relay Card 24 V DC - 01 No (xiii) Battery Charger 24 V DC 10 A-01 Nos (Xiv) Hooter -01 No (xv) Auxilary contactor 2 No+2 NC (MX0 22E) (Location - Main STP AF-I DG set )
6Supply and fix ON LOAD change over outdoor type switch 415 volt in sheet metal enclosure 4 pole of caapcity 400 Amp side handle operated complete with angle iron suitable for fixing arrangement including PCC work as required all as per directed.
7All as per Item No - 1 but bus bar capacity 250 Amp suitable for 125 KVA DG set with following items:-
8(i) MCCB 4 Pole , 36 KA, 250 Amps 415 Volts extended terminals, fixed setting type -02 Nos (ii) spreader terminal 4 pole (set of 8) - 04 Nos (iii) 255A FP Contactor (MCX34) --02 Nos (iv) Three Phase MFM Meter - 01 Nos (v) RYB Indicator Lamp - 02Nos (vi) Green Indicator Lamp - 02 Nos (vii) 250/5 Din type CL-1 VA -5CT --06 Nos (viii) 6A SP ,C MCB -LK -08 Nos (ix) 10 A DP 'C' MCB-LK -03Nos (x) selector switch 4 P 2W 6A-02 Nos (xi) E-stop push button -L&T -01 nos (xi) AMF Controller -01 NOs (xii) 8 Channel 1 C/O Relay Card 24 V DC - 01 No (xiii) Battery Charger 24 V DC 10 A-01 Nos (xiv) Hooter -01 No (xv) Auxilary contactor 2 No+2 NC (MX0 22E) (Location - DSC Pump House DG set )
9Supply and fix ON LOAD change over outdoor type switch 415 volt in sheet metal enclosure 4 pole of caapcity 250 Amp side handle operated complete with angle iron suitable for fixing arrangement including PCC work as required all as per directed.
10All as per Item No - 1 but bus bar capacity 200 Amp suitable for 100 KVA DG set with following items:-
11(i) MCCB 4 Pole , 25 KA,200 Amps 415 Volts -02 Nos (ii) spreader terminal DN1/DN2 - 4 pole (set of 8) - 04 Nos (iii) 200Amp FP Contactor (MCX33) -02 Nos (iv) Three Phase MFM Meter - 01 Nos (v) RYB Indicator Lamp - 02Nos (vi) Green Indicator Lamp - 02 Nos (vii) 200/5 Din type CL-1 VA -5CT --06 Nos (viii) 6A SP ,C MCB -LK -08 Nos (ix) 10 A DP 'C' MCB-LK -03Nos (x) selector switch 4 P 2W 6A-02 Nos (xi) E-stop push button -L&T -01 nos (xi) AMF Controller -01 NOs (xii) 8 Channel 1 C/O Relay Card 24 V DC - 01 No (xiii) Battery Charger 24 V DC 10 A-01 Nos (xiv) Hooter -01 No (xv) Auxilary contactor 2 No+2 NC (MX0 22E) (Location - MAP Pump House DG set )
12Supply and fix ON LOAD change over outdoor type switch 415 volt in sheet metal enclosure 4 pole of caapcity 200 Amp side handle operated complete with angle iron suitable for fixing arrangement including PCC work as required all as per directed.
13All as per Item No - 1 but bus bar capacity 160 Amp suitable for 75 KVA DG set with following items:-
14(i) MCCB 4 Pole , 25 KA, 160 Amps 415 Volts -02 Nos (ii) spreader terminal DN1/DN2 - 4 pole (set of 8) - 04 Nos (iii) 160Amp FP Contactor (MCX32) -02 Nos (iv) Three Phase MFM Meter - 01 Nos (v) RYB Indicator Lamp - 02Nos (vi) Green Indicator Lamp - 02 Nos (vii) 150/5 Din type CL-1 VA -5CT --06 Nos (viii) 6A SP ,C MCB -LK -08 Nos (ix) 10 A DP 'C' MCB-LK -03Nos (x) selector switch 4 P 2W 6A-02 Nos (xi) E-stop push button -L&T -01 nos (xi) AMF Controller -01 NOs (xii) 8 Channel 1 C/O Relay Card 24 V DC - 01 No (xiii) Battery Charger 24 V DC 10 A-01 Nos (xiv) Hooter -01 No (xv) Auxilary contactor 2 No+2 NC (MX0 22E) (Location - PS No-III DG set )
15Supply and fix ON LOAD change over outdoor type switch 415 volt in sheet metal enclosure 4 pole of caapcity 125 Amp side handle operated complete with angle iron suitable for fixing arrangement including PCC work as required all as per directed.
16All as per Item No - 1 but bus bar capacity 125 Amp suitable for 50 KVA DG set with following items:-
17(i) MCCB 4 Pole , 25 KA, 125 Amps 415 Volts -02 Nos (ii) spreader terminal DN1/DN2 - 4 pole (set of 8) - 04 Nos (iii) 130Amp FP Contactor (MCX32) -02 Nos (iv) Three Phase MFM Meter - 01 Nos (v) RYB Indicator Lamp - 02Nos (vi) Green Indicator Lamp - 02 Nos (vii) 150/5 Din type CL-1 VA -5CT --06 Nos (viii) 6A SP ,C MCB -LK -08 Nos (ix) 10 A DP 'C' MCB-LK -03Nos (x) selector switch 4 P 2W 6A-02 Nos (xi) E-stop push button -L&T -01 nos (xi) AMF Controller -01 NOs (xii) 8 Channel 1 C/O Relay Card 24 V DC - 01 No (xiii) Battery Charger 24 V DC 10 A-01 Nos (xiv) Hooter -01 No (xv) Auxilary contactor 2 No+2 NC (MX0 22E) (Location - Main power house AF-II )
18Supply and fix ON LOAD change over outdoor type switch 415 volt in sheet metal enclosure 4 pole of caapcity 63 Amp side handle operated complete with angle iron suitable for fixing arrangement including PCC work as required all as per directed.
19All as per Item No - 1 but bus bar capacity 100 Amp suitable for 35 KVA DG set with following items:-
20(i) MCCB 4 Pole , 25 KA,100 Amps 415 Volts -02 Nos (ii) spreader terminal DN1/DN2 - 4 pole (set of 8) - 04 Nos (iii) 80 Amp FP Contactor (MCX32) -02 Nos (iv) Three Phase MFM Meter - 01 Nos (v) RYB Indicator Lamp - 02Nos (vi) Green Indicator Lamp - 02 Nos (vii) 100/5 Din type CL-1 VA -5CT --06 Nos (viii) 6A SP ,C MCB -LK -08 Nos (ix) 10 A DP 'C' MCB-LK -03Nos (x) selector switch 4 P 2W 6A-02 Nos (xi) E-stop push button -L&T -01 nos (xi) AMF Controller -01 NOs (xii) 8 Channel 1 C/O Relay Card 24 V DC - 01 No (xiii) Battery Charger 24 V DC 10 A-01 Nos (xiv) Hooter -01 No (xv) Auxilary contactor 2 No+2 NC (MX0 22E) (Location - PS - II )
21All as per Item No - 1 but bus bar capacity 100 Amp suitable for 25 KVA DG set with following items:-
22(i) MCCB 4 Pole , 25 KA, 100Amps (DN0 - 100C) 415 Volts -02 Nos (ii) spreader terminal DN1/DN2 - 4 pole (set of 8) - 04 Nos (iii) 40 Amp FP Contactor (MCX 04) -02 Nos (iv) Three Phase MFM Meter - 01 Nos (v) RYB Indicator Lamp - 02Nos (vi) Green Indicator Lamp - 02 Nos (vii) 40/5 Din type CL-1 VA -5CT --06 Nos (viii) 6A SP ,C MCB -LK -08 Nos (ix) 10 A DP 'C' MCB-LK -03Nos (x) selector switch 4 P 2W 6A-02 Nos (xi) E-stop push button -L&T -01 nos (xi) AMF Controller -01 NOs (xii) 8 Channel 1 C/O Relay Card 24 V DC - 01 No (xiii) Battery Charger 24 V DC 10 A-01 Nos (xiv) Hooter -01 No (xv) Auxilary contactor 2 No+2 NC (MX0 22E) (Location - PS-I )
23Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 150 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & directed by Engr -in-charge.
24Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 120 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & directed by Engr -in-charge.
25Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 95 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & directed by Engr -in-charge.
26Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 70 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & directed by Engr -in-charge.
27Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 50 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & directed by Engr -in-charge.
28Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the earth plate at a depth of not less than 1.5 mtr below ground level connected to galvanized iron strip 25 x 3 mm as earthing lead by means of bolts, nuts and washers made out of GI/steel earth strip protected by GI light grade pipe of 40 mm dia and connecting to main panel board/switch board/control board all shown in electrical plate No 3 of SSR Pt I incl PCC chambers in 1:2:4 and RCC cover slab with 8mm dia MS bars reinforced at 10 cm center to center both ways incl earth work like excavation, returning filling back disposal etc complete.
29Excavation in trenches in hard dense soil n.exc 1.5 mtr wide & n.exc 1.5mtr in depth and n. exc. 10sqm on plan for laying pipe in trenches and getting out complete all as specified and directed.
30Returning filling in trenches, spreading, levelling, watering and well ramming in layers n.exc 25cm in hard dense soil complete all as specified and directed.
31Removing of surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above starting point complete all as specified and directed.
32M&L for providing dry river sand as in sand cushioning 18cm before and 5 cm after laying of under ground electric cable, thickness specified in SSR Part -I, including punning down of sand in layer all as specified and directed by Engr-in-Charge. Note: For measurement purpose punned thickness of sand only will be considered.
33Supply & laying ISI marked & conforming to IS - 5820 - 1970 unreinforced precast concrete cable cover Class LV, flat of size 250 mm X 150 mm X 40 mm in trenches as protection to LT UG cable all as specified and directed by Engr-in-Charge.
34Material and Labour for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint etc all complete.
35M & L for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, velley gutter fixed with self tapping screws completed all as apecified and directed.
36Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out in any type of soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm completed all as apecified and directed.
37Supply & Fixing 5 star rated electric storage water heater (vertical type) 25 Ltr, 230 V, AC, Single phase power input 2000w,standing loss in kWh 24 (hours) 45 °C 0.511 kWh with and including connecting fastners nuts not less than 100 mm with suitable nut, bolt & washers grouted in walls with complete masonary work for proper mounting of Geyser fastning bolts etc as directed as site reqmt and making necessary inlet and outlet water connection as well as electric connection including testing on load for entire satisfaction of Engineer-in-Charge
38M&L for sub main wiring using PVC insulated and unsheathed multistranded FRLS copper conductor cable using approved colour code as per IS drawing in and incl PVC casing and capping with all accessories and making good disturbed surfaces of wall, floor or ceiling with plaster and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete as specified and as directed by Engr-in-charge of the following sizes of cables.
39Using two single core PVC insulated FRLS cable 2.5 sqmm copper conductor multi stranded and 1.5 sqmm copper conductor insulated cable using as earth wire Note :2 runs of 2.5sqmm copper cable & 1 run of 2.5 sqmm copper cable in and including PVC casing and capping shall be measured as one unit
40S&F for single pole and neutral enclosure with two pin and earth plug and socket complete with a single pole MCB 20 Amps complete in sheet metal enclosure complete all as specified and directed.
41M&L for MCB single pole,5 to 30 Amp 240 volt B curve 10 KA, IP 20 complete all as specified and directed.
42Supply & Fixing GI pipe 15 mm bore medium grade with all fitting such as unions, tee, nipple, short lengthand socket for connecting and fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
43Supply & Fixing GI pipe 20 mm bore medium grade with all fitting such as unions, tee, nipple, short lengthand socket for connecting and fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
44S & F PVC connection nylon braided 15 mm size with PTMT nuts 450/600 mm long for hot/cold Water to and from geyser complete all as specified and directed.
45S & F stop valve 15 mm bore heavy duty fancy type chromium plate with long sunk and cup connected in wall clamps as per site reqmt for cold water inlet & hot water outlet connection complete all as specified and directed.
46S & F Bib cock 15 mm bore heavy duty fancy type chromium plate with long sunk and cup connected in wall clamps as per site reqmt for WHB purpose complete all as specified and directed.
47Supply and fix in repair 15 mm size Angular cock, cast copper alloy chromium plated, screwed down high pressure with capstan head, screwed both ends for iron pipe or unions, complete all as specified and directed.
48M & L for cutting hole not exceeding 150 sqmm into through brick wall built in cement mortar or stone wall / RCC wall built in lime mortar / concrete for passing inlet pipe of geyser through walls or as per site reqmt all as directed including making good the disturbed surfaces.
49S & F energy efficient BLDC Ceiling Fan, 1200mm sweep BEE 5 star rated, AC single phase, 230 volts, 50 Hz, and connecting up including provision of three core flexible copper wire of size 1.5 sqmm from ceiling rose to ceiling fan complete in all respect and all accessories complete all as specified and directed.
50Supply and fixing Exhaust fans, AC single phase, 230/240 volts, 50 Hz, Metalic body 300mm sweep, 1400 RPM with louvers, fixing with 4 nos hold fastener nut and bolt with washer and connecting with flexible PVC insulated multistranded copper conductor cable of size 0.75 sqmm from ceiling rose to exhaust fan including civil work for making opening on wall of suitable size for installation of exhaust fan and making good complete all as specified and directed.
51Supply and fixing Exhaust fan, PVC body, heavy duty, AC single Phase, 230V of size 200/250mm sweep with, blades, and frame and louvers complete and other accessories etc complete all as specified and directed.
52Supply and fix LED solar post top with built in solar panel LED light and lithium battery with charge controller and 2 PIR sensors wiyh 360 degree coverage IP 65 complete all as specified and directed. Make- Havells cat part No-BUDZ 1W 5700K Solar Bollard light or equivalent make as mentioned in Appx 'B' to PS.
53Supply and fix MANO LED Post Top IP65 LED Solar post top with built-in Solar panel, LED light and Lithium battery with charge controller and 2 PIR sensors with 360º coverage with charge controller and 2 PIR sensors wiyh 360 degree coverage IP 65 complete all as specified and directed. Make- Havells cat part No-MANOR 20 W 5700 K Solar Post Top or equivalent make as mentioned in Appx 'B' to PS. Please Enable Macros to View BoQ information
54Supply and fix MANO LED Post Top IP65 LED Solar post top with built-in Solar panel, LED light and Lithium battery with charge controller and 2 PIR sensors with 360º coverage with charge controller and 2 PIR sensors wiyh 360 degree coverage IP 65 complete all as specified and directed. Make- Havells cat part No-MANOR 20 W 5700 K Solar Post Top or equivalent make as mentioned in Appx 'B' to PS. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57086245
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45 Lakhs
LAST DATE 08-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Provision Of Certain Sanction Works Of Electrical And Mechanical Works Under Ge (Af) Jamnagar No.2- 1 Supply , Installation, Testing And Commissioning Of Factory Made Cpri Approved, Outdoor Type Amf Panel For Dg Set Of Capacity 320Kva Made Out Of 3.15Mm Thick Crca Sheet, 415Volts, 3 Phase, 50Hz Supply Mounted On And Including Ms Angle Section 50X50X5Mm Thick Ms Frame With Front And Back Openable, Double Door With Provision Of Locking Arrangement Dust Proof, Gasket, Tpn Busbar Aluminium Of Capacity 630Amp Bus Bar With Formica Sheet , Rubber Gasket, Wiring With Copper Wire And Lugs Shall Be Insulated With Colour Coated Heat Shrinkable Sleeves And Shall Be Mounted On Proper Insulator, Gland, Welding Hinges Of Dust Proof, Overall Power Coated Complete With All Following Items Mccb , Amf Controller, Battery Charger Etc., All As Specified And Directed & Including Excavation For Panel Board Installation And Pcc 1:4:8 And Pcc 1:3:6 For Foundation Work Complete With Dismantlimng Of Exsting Panel Board :- 2 (I) Mccb 4 Pole , 36 Ka, 630 Amps 415 Volts Extended Terminals, Fixed Setting Type -02 Nos (Ii) Spreader Terminal 630A (Set Of 8) - 04 Nos (Iii) 600A Fp Contactor( Mcx 45 ) (Mcx45) --02 Nos (Iv) Three Phase Mfm Meter - 01 Nos (V) Ryb Indicator Lamp - 02Nos (Vi) Green Indicator Lamp - 02 Nos (Vii) 600/5 Ring Type Cl-1 Va -15Ct --06 Nos (Viii) 6A Sp ,C Mcb -Lk -08 Nos (Ix) 10 A Dp C Mcb-Lk -03Nos (X) Selector Switch 4 P 2W 6A-02 Nos (Xi) E-Stop Push Button -L&T -01 Nos (Xi) Amf Controller -01 No (Xii) 8 Channel 1 C/O Relay Card 24 V Dc --01 No (Xiii) Battery Charger 24 V Dc 10 A-01 Nos (Xiv) Hooter -01 No (Xv) Auxilary Contactor 2 No+2 Nc (Mx0 22E) (Location - Filtration Plant Af-Ii Dg Set ) 3 Supply And Fix On Load Change Over Outdoor Type Switch 415 Volt In Sheet Metal Enclosure 4 Pole Of Caapcity 630 Amp Side Handle Operated Complete With Angle Iron Suitable For Fixing Arrangement Including Pcc Work As Required All As Per Directed. 4 All As Per Item No - 1 But Bus Bar Capacity 400 Amp Suitable For 160Kva Dg Set With Following Items:- 5 (I) Mccb 4 Pole , 36 Ka, 400 Amps 415 Volts Extended Terminals, Fixed Setting Type -02 Nos (Ii) Spreader Terminal 400 - 4 Pole (Set Of 8) - 04 Nos (Iii) 325A Fp Contactor( Mcx 41) --02 Nos (Iv) Three Phase Mfm Meter - 01 Nos (V) Ryb Indicator Lamp - 02Nos (Vi) Green Indicator Lamp - 02 Nos (Vii) 400/5 Ring Type Cl-1 Va -15Ct --06 Nos (Viii) 6A Sp ,C Mcb -Lk -08 Nos (Ix) 10 A Dp C Mcb-Lk -03Nos (X) Selector Switch 4 P 2W 6A-02 Nos (Xi) E-Stop Push Button -L&T -01 Nos (Xi) Amf Controller -01 Nos (Xii) 8 Channel 1 C/O Relay Card 24 V Dc - 01 No (Xiii) Battery Charger 24 V Dc 10 A-01 Nos (Xiv) Hooter -01 No (Xv) Auxilary Contactor 2 No+2 Nc (Mx0 22E) (Location - Main Stp Af-I Dg Set ) 6 Supply And Fix On Load Change Over Outdoor Type Switch 415 Volt In Sheet Metal Enclosure 4 Pole Of Caapcity 400 Amp Side Handle Operated Complete With Angle Iron Suitable For Fixing Arrangement Including Pcc Work As Required All As Per Directed. 7 All As Per Item No - 1 But Bus Bar Capacity 250 Amp Suitable For 125 Kva Dg Set With Following Items:- 8 (I) Mccb 4 Pole , 36 Ka, 250 Amps 415 Volts Extended Terminals, Fixed Setting Type -02 Nos (Ii) Spreader Terminal 4 Pole (Set Of 8) - 04 Nos (Iii) 255A Fp Contactor (Mcx34) --02 Nos (Iv) Three Phase Mfm Meter - 01 Nos (V) Ryb Indicator Lamp - 02Nos (Vi) Green Indicator Lamp - 02 Nos (Vii) 250/5 Din Type Cl-1 Va -5Ct --06 Nos (Viii) 6A Sp ,C Mcb -Lk -08 Nos (Ix) 10 A Dp C Mcb-Lk -03Nos (X) Selector Switch 4 P 2W 6A-02 Nos (Xi) E-Stop Push Button -L&T -01 Nos (Xi) Amf Controller -01 Nos (Xii) 8 Channel 1 C/O Relay Card 24 V Dc - 01 No (Xiii) Battery Charger 24 V Dc 10 A-01 Nos (Xiv) Hooter -01 No (Xv) Auxilary Contactor 2 No+2 Nc (Mx0 22E) (Location - Dsc Pump House Dg Set ) 9 Supply And Fix On Load Change Over Outdoor Type Switch 415 Volt In Sheet Metal Enclosure 4 Pole Of Caapcity 250 Amp Side Handle Operated Complete With Angle Iron Suitable For Fixing Arrangement Including Pcc Work As Required All As Per Directed. 10 All As Per Item No - 1 But Bus Bar Capacity 200 Amp Suitable For 100 Kva Dg Set With Following Items:- 11 (I) Mccb 4 Pole , 25 Ka,200 Amps 415 Volts -02 Nos (Ii) Spreader Terminal Dn1/Dn2 - 4 Pole (Set Of 8) - 04 Nos (Iii) 200Amp Fp Contactor (Mcx33) -02 Nos (Iv) Three Phase Mfm Meter - 01 Nos (V) Ryb Indicator Lamp - 02Nos (Vi) Green Indicator Lamp - 02 Nos (Vii) 200/5 Din Type Cl-1 Va -5Ct --06 Nos (Viii) 6A Sp ,C Mcb -Lk -08 Nos (Ix) 10 A Dp C Mcb-Lk -03Nos (X) Selector Switch 4 P 2W 6A-02 Nos (Xi) E-Stop Push Button -L&T -01 Nos (Xi) Amf Controller -01 Nos (Xii) 8 Channel 1 C/O Relay Card 24 V Dc - 01 No (Xiii) Battery Charger 24 V Dc 10 A-01 Nos (Xiv) Hooter -01 No (Xv) Auxilary Contactor 2 No+2 Nc (Mx0 22E) (Location - Map Pump House Dg Set ) 12 Supply And Fix On Load Change Over Outdoor Type Switch 415 Volt In Sheet Metal Enclosure 4 Pole Of Caapcity 200 Amp Side Handle Operated Complete With Angle Iron Suitable For Fixing Arrangement Including Pcc Work As Required All As Per Directed. 13 All As Per Item No - 1 But Bus Bar Capacity 160 Amp Suitable For 75 Kva Dg Set With Following Items:- 14 (I) Mccb 4 Pole , 25 Ka, 160 Amps 415 Volts -02 Nos (Ii) Spreader Terminal Dn1/Dn2 - 4 Pole (Set Of 8) - 04 Nos (Iii) 160Amp Fp Contactor (Mcx32) -02 Nos (Iv) Three Phase Mfm Meter - 01 Nos (V) Ryb Indicator Lamp - 02Nos (Vi) Green Indicator Lamp - 02 Nos (Vii) 150/5 Din Type Cl-1 Va -5Ct --06 Nos (Viii) 6A Sp ,C Mcb -Lk -08 Nos (Ix) 10 A Dp C Mcb-Lk -03Nos (X) Selector Switch 4 P 2W 6A-02 Nos (Xi) E-Stop Push Button -L&T -01 Nos (Xi) Amf Controller -01 Nos (Xii) 8 Channel 1 C/O Relay Card 24 V Dc - 01 No (Xiii) Battery Charger 24 V Dc 10 A-01 Nos (Xiv) Hooter -01 No (Xv) Auxilary Contactor 2 No+2 Nc (Mx0 22E) (Location - Ps No-Iii Dg Set ) 15 Supply And Fix On Load Change Over Outdoor Type Switch 415 Volt In Sheet Metal Enclosure 4 Pole Of Caapcity 125 Amp Side Handle Operated Complete With Angle Iron Suitable For Fixing Arrangement Including Pcc Work As Required All As Per Directed. 16 All As Per Item No - 1 But Bus Bar Capacity 125 Amp Suitable For 50 Kva Dg Set With Following Items:- 17 (I) Mccb 4 Pole , 25 Ka, 125 Amps 415 Volts -02 Nos (Ii) Spreader Terminal Dn1/Dn2 - 4 Pole (Set Of 8) - 04 Nos (Iii) 130Amp Fp Contactor (Mcx32) -02 Nos (Iv) Three Phase Mfm Meter - 01 Nos (V) Ryb Indicator Lamp - 02Nos (Vi) Green Indicator Lamp - 02 Nos (Vii) 150/5 Din Type Cl-1 Va -5Ct --06 Nos (Viii) 6A Sp ,C Mcb -Lk -08 Nos (Ix) 10 A Dp C Mcb-Lk -03Nos (X) Selector Switch 4 P 2W 6A-02 Nos (Xi) E-Stop Push Button -L&T -01 Nos (Xi) Amf Controller -01 Nos (Xii) 8 Channel 1 C/O Relay Card 24 V Dc - 01 No (Xiii) Battery Charger 24 V Dc 10 A-01 Nos (Xiv) Hooter -01 No (Xv) Auxilary Contactor 2 No+2 Nc (Mx0 22E) (Location - Main Power House Af-Ii ) 18 Supply And Fix On Load Change Over Outdoor Type Switch 415 Volt In Sheet Metal Enclosure 4 Pole Of Caapcity 63 Amp Side Handle Operated Complete With Angle Iron Suitable For Fixing Arrangement Including Pcc Work As Required All As Per Directed. 19 All As Per Item No - 1 But Bus Bar Capacity 100 Amp Suitable For 35 Kva Dg Set With Following Items:- 20 (I) Mccb 4 Pole , 25 Ka,100 Amps 415 Volts -02 Nos (Ii) Spreader Terminal Dn1/Dn2 - 4 Pole (Set Of 8) - 04 Nos (Iii) 80 Amp Fp Contactor (Mcx32) -02 Nos (Iv) Three Phase Mfm Meter - 01 Nos (V) Ryb Indicator Lamp - 02Nos (Vi) Green Indicator Lamp - 02 Nos (Vii) 100/5 Din Type Cl-1 Va -5Ct --06 Nos (Viii) 6A Sp ,C Mcb -Lk -08 Nos (Ix) 10 A Dp C Mcb-Lk -03Nos (X) Selector Switch 4 P 2W 6A-02 Nos (Xi) E-Stop Push Button -L&T -01 Nos (Xi) Amf Controller -01 Nos (Xii) 8 Channel 1 C/O Relay Card 24 V Dc - 01 No (Xiii) Battery Charger 24 V Dc 10 A-01 Nos (Xiv) Hooter -01 No (Xv) Auxilary Contactor 2 No+2 Nc (Mx0 22E) (Location - Ps - Ii ) 21 All As Per Item No - 1 But Bus Bar Capacity 100 Amp Suitable For 25 Kva Dg Set With Following Items:- 22 (I) Mccb 4 Pole , 25 Ka, 100Amps (Dn0 - 100C) 415 Volts -02 Nos (Ii) Spreader Terminal Dn1/Dn2 - 4 Pole (Set Of 8) - 04 Nos (Iii) 40 Amp Fp Contactor (Mcx 04) -02 Nos (Iv) Three Phase Mfm Meter - 01 Nos (V) Ryb Indicator Lamp - 02Nos (Vi) Green Indicator Lamp - 02 Nos (Vii) 40/5 Din Type Cl-1 Va -5Ct --06 Nos (Viii) 6A Sp ,C Mcb -Lk -08 Nos (Ix) 10 A Dp C Mcb-Lk -03Nos (X) Selector Switch 4 P 2W 6A-02 Nos (Xi) E-Stop Push Button -L&T -01 Nos (Xi) Amf Controller -01 Nos (Xii) 8 Channel 1 C/O Relay Card 24 V Dc - 01 No (Xiii) Battery Charger 24 V Dc 10 A-01 Nos (Xiv) Hooter -01 No (Xv) Auxilary Contactor 2 No+2 Nc (Mx0 22E) (Location - Ps-I ) 23 Supply & Lay Xlpe Insulated, Pvc Inner Sheathed, Armoured With Galvanised Steel Strip Or Wire, Heavy Duty, Lt Underground Cable Isi Marked With Aluminium Multistranded Conductor 1100 Volt Grade Of Size 150 Sqmm 3.5 Core Laid In Trenches / Duct Passing Through Pipe / Duct Or Fixed On Pole And Connecting And Testing Etc Including Taking Down Old Cable Complete All As Specified & Directed By Engr -In-Charge. 24 Supply & Lay Xlpe Insulated, Pvc Inner Sheathed, Armoured With Galvanised Steel Strip Or Wire, Heavy Duty, Lt Underground Cable Isi Marked With Aluminium Multistranded Conductor 1100 Volt Grade Of Size 120 Sqmm 3.5 Core Laid In Trenches / Duct Passing Through Pipe / Duct Or Fixed On Pole And Connecting And Testing Etc Including Taking Down Old Cable Complete All As Specified & Directed By Engr -In-Charge. 25 Supply & Lay Xlpe Insulated, Pvc Inner Sheathed, Armoured With Galvanised Steel Strip Or Wire, Heavy Duty, Lt Underground Cable Isi Marked With Aluminium Multistranded Conductor 1100 Volt Grade Of Size 95 Sqmm 3.5 Core Laid In Trenches / Duct Passing Through Pipe / Duct Or Fixed On Pole And Connecting And Testing Etc Including Taking Down Old Cable Complete All As Specified & Directed By Engr -In-Charge. 26 Supply & Lay Xlpe Insulated, Pvc Inner Sheathed, Armoured With Galvanised Steel Strip Or Wire, Heavy Duty, Lt Underground Cable Isi Marked With Aluminium Multistranded Conductor 1100 Volt Grade Of Size 70 Sqmm 3.5 Core Laid In Trenches / Duct Passing Through Pipe / Duct Or Fixed On Pole And Connecting And Testing Etc Including Taking Down Old Cable Complete All As Specified & Directed By Engr -In-Charge. 27 Supply & Lay Xlpe Insulated, Pvc Inner Sheathed, Armoured With Galvanised Steel Strip Or Wire, Heavy Duty, Lt Underground Cable Isi Marked With Aluminium Multistranded Conductor 1100 Volt Grade Of Size 50 Sqmm 3.5 Core Laid In Trenches / Duct Passing Through Pipe / Duct Or Fixed On Pole And Connecting And Testing Etc Including Taking Down Old Cable Complete All As Specified & Directed By Engr -In-Charge. 28 Earthing Complete With Galvanized Steel Earth Plate Electrode 60Cm X 60Cm X 6Mm Thick Buried Directly In Ground (Earth Pit Not Less Than 2.25 Mtrs Deep Below Ground Level) With Top Edge Of The Earth Plate At A Depth Of Not Less Than 1.5 Mtr Below Ground Level Connected To Galvanized Iron Strip 25 X 3 Mm As Earthing Lead By Means Of Bolts, Nuts And Washers Made Out Of Gi/Steel Earth Strip Protected By Gi Light Grade Pipe Of 40 Mm Dia And Connecting To Main Panel Board/Switch Board/Control Board All Shown In Electrical Plate No 3 Of Ssr Pt I Incl Pcc Chambers In 1:2:4 And Rcc Cover Slab With 8Mm Dia Ms Bars Reinforced At 10 Cm Center To Center Both Ways Incl Earth Work Like Excavation, Returning Filling Back Disposal Etc Complete. 29 Excavation In Trenches In Hard Dense Soil N.Exc 1.5 Mtr Wide & N.Exc 1.5Mtr In Depth And N. Exc. 10Sqm On Plan For Laying Pipe In Trenches And Getting Out Complete All As Specified And Directed. 30 Returning Filling In Trenches, Spreading, Levelling, Watering And Well Ramming In Layers N.Exc 25Cm In Hard Dense Soil Complete All As Specified And Directed. 31 Removing Of Surplus Soil To A Distance N.Exc 50 Mtr And Depositing Where Directed At A Level N.Exc 1.5 Mtr Above Starting Point Complete All As Specified And Directed. 32 M&L For Providing Dry River Sand As In Sand Cushioning 18Cm Before And 5 Cm After Laying Of Under Ground Electric Cable, Thickness Specified In Ssr Part -I, Including Punning Down Of Sand In Layer All As Specified And Directed By Engr-In-Charge. Note: For Measurement Purpose Punned Thickness Of Sand Only Will Be Considered. 33 Supply & Laying Isi Marked & Conforming To Is - 5820 - 1970 Unreinforced Precast Concrete Cable Cover Class Lv, Flat Of Size 250 Mm X 150 Mm X 40 Mm In Trenches As Protection To Lt Ug Cable All As Specified And Directed By Engr-In-Charge. 34 Material And Labour For Cross Arms, Bracings, Supports, Clamps And Back Plates Fabricated From Structural Steel Sections Including Nuts, Bolts, Washers, Welding, Bending Cold Or Hot, Drilling Holes For Bolts, In Any Shape Or Size As Indicated Or Directed And Inclusive Of One Primer Coat, One Under Coat And One Finishing Coat Of Paint Etc All Complete. 35 M & L For Pre-Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet 0.5Mm Of An Colour Having Tensile Strength Of 550Mpa As In Roof Covering/Cladding To Wall, Velley Gutter Fixed With Self Tapping Screws Completed All As Apecified And Directed. 36 Excavating In Post Holes (Or Similar Holes) Each N Exc 0.5 Cu. M, Getting Out In Any Type Of Soil, Returning, Filling In And Ramming Earth Or Broken Rubble Mixed With Earth Around, In Layers Not Exceeding 25 Cm Completed All As Apecified And Directed. 37 Supply & Fixing 5 Star Rated Electric Storage Water Heater (Vertical Type) 25 Ltr, 230 V, Ac, Single Phase Power Input 2000W,Standing Loss In Kwh 24 (Hours) 45 °C 0.511 Kwh With And Including Connecting Fastners Nuts Not Less Than 100 Mm With Suitable Nut, Bolt & Washers Grouted In Walls With Complete Masonary Work For Proper Mounting Of Geyser Fastning Bolts Etc As Directed As Site Reqmt And Making Necessary Inlet And Outlet Water Connection As Well As Electric Connection Including Testing On Load For Entire Satisfaction Of Engineer-In-Charge 38 M&L For Sub Main Wiring Using Pvc Insulated And Unsheathed Multistranded Frls Copper Conductor Cable Using Approved Colour Code As Per Is Drawing In And Incl Pvc Casing And Capping With All Accessories And Making Good Disturbed Surfaces Of Wall, Floor Or Ceiling With Plaster And Finishing The Surfaces With Distemper/White Washing/Colour Washing To Match With The Existing Surface Complete As Specified And As Directed By Engr-In-Charge Of The Following Sizes Of Cables. 39 Using Two Single Core Pvc Insulated Frls Cable 2.5 Sqmm Copper Conductor Multi Stranded And 1.5 Sqmm Copper Conductor Insulated Cable Using As Earth Wire Note :2 Runs Of 2.5Sqmm Copper Cable & 1 Run Of 2.5 Sqmm Copper Cable In And Including Pvc Casing And Capping Shall Be Measured As One Unit 40 S&F For Single Pole And Neutral Enclosure With Two Pin And Earth Plug And Socket Complete With A Single Pole Mcb 20 Amps Complete In Sheet Metal Enclosure Complete All As Specified And Directed. 41 M&L For Mcb Single Pole,5 To 30 Amp 240 Volt B Curve 10 Ka, Ip 20 Complete All As Specified And Directed. 42 Supply & Fixing Gi Pipe 15 Mm Bore Medium Grade With All Fitting Such As Unions, Tee, Nipple, Short Lengthand Socket For Connecting And Fixed Complete To Walls And Ceiling Or Laid In Floors Complete All As Specified And Directed. 43 Supply & Fixing Gi Pipe 20 Mm Bore Medium Grade With All Fitting Such As Unions, Tee, Nipple, Short Lengthand Socket For Connecting And Fixed Complete To Walls And Ceiling Or Laid In Floors Complete All As Specified And Directed. 44 S & F Pvc Connection Nylon Braided 15 Mm Size With Ptmt Nuts 450/600 Mm Long For Hot/Cold Water To And From Geyser Complete All As Specified And Directed. 45 S & F Stop Valve 15 Mm Bore Heavy Duty Fancy Type Chromium Plate With Long Sunk And Cup Connected In Wall Clamps As Per Site Reqmt For Cold Water Inlet & Hot Water Outlet Connection Complete All As Specified And Directed. 46 S & F Bib Cock 15 Mm Bore Heavy Duty Fancy Type Chromium Plate With Long Sunk And Cup Connected In Wall Clamps As Per Site Reqmt For Whb Purpose Complete All As Specified And Directed. 47 Supply And Fix In Repair 15 Mm Size Angular Cock, Cast Copper Alloy Chromium Plated, Screwed Down High Pressure With Capstan Head, Screwed Both Ends For Iron Pipe Or Unions, Complete All As Specified And Directed. 48 M & L For Cutting Hole Not Exceeding 150 Sqmm Into Through Brick Wall Built In Cement Mortar Or Stone Wall / Rcc Wall Built In Lime Mortar / Concrete For Passing Inlet Pipe Of Geyser Through Walls Or As Per Site Reqmt All As Directed Including Making Good The Disturbed Surfaces. 49 S & F Energy Efficient Bldc Ceiling Fan, 1200Mm Sweep Bee 5 Star Rated, Ac Single Phase, 230 Volts, 50 Hz, And Connecting Up Including Provision Of Three Core Flexible Copper Wire Of Size 1.5 Sqmm From Ceiling Rose To Ceiling Fan Complete In All Respect And All Accessories Complete All As Specified And Directed. 50 Supply And Fixing Exhaust Fans, Ac Single Phase, 230/240 Volts, 50 Hz, Metalic Body 300Mm Sweep, 1400 Rpm With Louvers, Fixing With 4 Nos Hold Fastener Nut And Bolt With Washer And Connecting With Flexible Pvc Insulated Multistranded Copper Conductor Cable Of Size 0.75 Sqmm From Ceiling Rose To Exhaust Fan Including Civil Work For Making Opening On Wall Of Suitable Size For Installation Of Exhaust Fan And Making Good Complete All As Specified And Directed. 51 Supply And Fixing Exhaust Fan, Pvc Body, Heavy Duty, Ac Single Phase, 230V Of Size 200/250Mm Sweep With, Blades, And Frame And Louvers Complete And Other Accessories Etc Complete All As Specified And Directed. 52 Supply And Fix Led Solar Post Top With Built In Solar Panel Led Light And Lithium Battery With Charge Controller And 2 Pir Sensors Wiyh 360 Degree Coverage Ip 65 Complete All As Specified And Directed. Make- Havells Cat Part No-Budz 1W 5700K Solar Bollard Light Or Equivalent Make As Mentioned In Appx B To Ps. 53 Supply And Fix Mano Led Post Top Ip65 Led Solar Post Top With Built-In Solar Panel, Led Light And Lithium Battery With Charge Controller And 2 Pir Sensors With 360º Coverage With Charge Controller And 2 Pir Sensors Wiyh 360 Degree Coverage Ip 65 Complete All As Specified And Directed. Make- Havells Cat Part No-Manor 20 W 5700 K Solar Post Top Or Equivalent Make As Mentioned In Appx B To Ps. Please Enable Macros To View Boq Information
Basic Detail
Tender No 8671/E8
Bidding Type Tender
Location
City Jamnagar
State Gujarat
Key Dates
Publish Date 18 Aug 2026
Submission Date 08 Sep 2026
Open Date 10 Sep 2026
Finance
Tender Value 45 Lakhs
Tender Fee 500
EMD 90000
Exemption Available
Document List
51PTenderDocs.pdf
56a55313-7280-4587-8490-93f01f90fd6b.html
BOQ_879578.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Sep 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
pdf

51PTenderDocs.pdf

html

56a55313-7280-4587-8490-93f01f90fd6b.html

xls

BOQ_879578.xls

pdf

Tendernotice_1.pdf