Tender For Special Repair To Lt Cable And Other Misc Works Under Jorhat Mil Stn.
Tender Value
43.54 Lakhs
Estimated cost
Bid Submission
07 Sep 2026
14 days left
EMD
87500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jorhat → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repair To Lt Cable And Other Misc Works Under Jorhat Mil Stn.
BOQ
| Sl. No. | Item Description |
| 1 | NOTE:-(i) The bidders/contractors are advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates.(ii) It is highlighted that the certain condition of General Condition of Contracts (IAFW-2249) has been modified as per direction of MoD i.e. inclusssion of Performance Security, deletion of Risk & Cost Provisions and increase in defect liability period all as per tender documents. The tenderers should keep in mind while quoting their offer. (iii) (Applicable for all items/parts):- The bidders/contractors are advised to refer Notes on BOQ/SCH'A' before entry/quoting the rates. |
| 2 | Supply , install, testing and commissioning as in replacement of cubical housing cabinet type CPRI approved Confirming to IP55 LT panel board outdoor type of size 0.80m x 0.80m x 0.40m, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3.15 mm thick CRCA MS Sheet and built upon suitable size MS angle iron frame work, having front and rear hinged doors, lifting lugs (2 Nos), earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coat of synethetic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts, 50Hz, 3 phase 4 wire system and internal connection should be provided with aluminium strips of suitable size and necessary foundation work and comprising following:-System Voltage-415V, 3-Ph, 4 wire, 50 HZAluminium BUSBAR rating -200 Amps, cable entry (incomming and outgoing ) form bottom with cable gland Incomming : 63 Amps MCCB FP, 16 KA, 415 Volts, 50 Hz-01 No Outgoing - (a) MCB 4 pole 40 Amps 10 kA Ac 50 Hz - 01 Nos(b) Fully Automatic Star Delta Starter-01 No(c) Motor Protection Relay - 01 No(d) Digital Multifunction Meter - 01 No(e) LED indicating lamps -03 Nos(f) Spare Compartment - 01 No |
| 3 | Labour only for boring of hole under roads with mechanical arrangement upto 50 mm dia without disturbing the top surface of the road for passing the cable across the road complete all as specified and as directed. |
| 4 | Supply and laying GI tubing 40mm bore light grade with fittings laid in trenches or for road crossing for protection of LT underground cables including taking up old unserviceable pipe complete all as specified and as directed. |
| 5 | Supply and laying GI tubing 80mm bore light grade with fittings laid in trenches or for road crossing for protection of LT underground cables including taking up old unserviceable pipe complete all as specified and as directed. |
| 6 | Material and labour for HDPE pipe of pressure rating 10 kgf/cm² and dia 75 mm for passing of cable through PCC foundation from trench to distribution board with necessary clamp nuts and bolts complete all as specified and as directed. |
| 7 | Material and labour for HDPE pipe of pressure rating 10 kgf/cm² and dia 100 mm for passing of cable through PCC foundation from trench to distribution board with necessary clamp nuts and bolts complete all as specified and as directed. |
| 8 | Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 16 Sqmm 4 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc. and replaement of old unserviceable cable complete all as specified and as directed. |
| 9 | Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 25 Sqmm 4 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc. and replaement of old unserviceable cable complete all as specified and as directed. |
| 10 | Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 35 Sqmm 3.5 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc. and replaement of old unserviceable cable complete all as specified and as directed. |
| 11 | Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 50 Sqmm 3.5 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc. and replaement of old unserviceable cable complete all as specified and as directed. |
| 12 | Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 70 Sqmm 3.5 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc. and replaement of old unserviceable cable complete all as specified and as directed. |
| 13 | Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 95 Sqmm 3.5 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc. and replaement of old unserviceable cable complete all as specified and as directed. |
| 14 | Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 120 Sqmm 3.5 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc. and replaement of old unserviceable cable complete all as specified and as directed. |
| 15 | Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 150 Sqmm 3.5 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc. and replaement of old unserviceable cable complete all as specified and as directed. |
| 16 | Material and labour for LT 1.1 KV (Earthed) grade heat shrinkable end termination jointing kit straight through joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 to 50 sqmm complete all as specified and as directed. |
| 17 | Material and labour for LT 1.1 KV (Earthed) grade heat shrinkable end termination jointing kit straight through joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 to 100 sqmm complete all as specified and as directed. |
| 18 | Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m in depth for taking out and laying at cable etc soft/loose soil complete all as specified and as directed. |
| 19 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm on soft/loose soil complete all as specified and as directed. |
| 20 | Removing excavated materials not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. |
| 21 | Material and labour for sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 cm in depth after laying the Cable) and consolidated (punned) upto 18 cm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only shall be measured and paid for. |
| 22 | Material and labour for Brick with subclass 'B' bricks in cable protection, laying with built in each other complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysSep 08, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender