Housing Urban and Rular Development Local Bodies Closing in 1 days TDR #57086046

Tender For Providing And Installation Of Cctvs Cameras At Block -B, Of Children Home, Snehalaya For Boys, Maloya, Chandigarh.

Issued by Local Bodies · Chandigarh, Chandigarh
Tender Value
32.32 Lakhs
Estimated cost
Bid Submission
26 Aug 2026
1 days left
EMD
64700
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Providing And Installation Of Cctvs Cameras At Block -B, Of Children Home, Snehalaya For Boys, Maloya, Chandigarh.

BOQ

Name of Work:- PROVIDING AND INSTALLATION OF CCTVS CAMERAS AT BLOCK –B, OF CHILDREN HOME, SNEHALAYA FOR BOYS, MALOYA, CHANDIGARH.
Sl. No. Item Description
1DSR 40.6 Supplying Installation Testing and Commissioning of 5MP/6 MP IP IR Bullet Camera having following specifications, type of lens and features etc AS PER COMPLETE ITEM NO.1 OF DNIT.
25MP/6MP IP IR 2.7 to 4 mm ~12 to 13.5mm or better Varifocal Motorized lens outdoor Bullet Camera.
3DSR 40.5 Supplying Installation Testing and Commissioning of 5/6MP IP IR Dome Camera having following specifications and features etc AS PER COMPLETE ITEM NO.2 OF DNIT.
45MP/6MP IP IR 2.7 to 4 mm ~12 to 13.5mm or better Varifocal Motorized lens Dome Camera.
5DSR 40.9 Supplying Installation Testing and Commissioning of PTZ (Pan,Tilt and Zoom) IP IR Camera having following spcifications and features etc :- PTZ (Pan,Tilt and Zoom) IP IR Camera having following spcifications and features etc AS PER COMPLETE ITEM NO.3 OF DNIT.
65MP IP IR motorized PTZ @25/30fps or better camera, Triple streaming , configurable on resolution:- Main stream: 5MP@25/30 fps Sub streams:1080p@25/30 fps, varifocal lens 3.95mm (±5mm) ~ 177.75mm (±5mm) or better with Automatic & manual Focus Adjustment provisions, 32x Optical zoom and 12x Digital zoom with angle of view H:65.7°–1.9°V: 39.4°–1.1°D: 73.1°–2.1, PAN Travel: Pan: 0° ~ 360° endless,Manual Pan: 260° /s, Preset : 300° /s, Tilt Travel: Tilt: -20° ~ 90°, auto flip 180°, Manual Tilt: 120° /s, Preset : 200° /s
7DSR Item no.40.11Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc AS PER COMPLETE ITEM NO.4 OF DNIT.
864 Channel Network Video Recorder (NVR) having display split:- Main screen: 1/4/8/9/16/25/36/64, 2nd screen: 1/4/8/9/16
9DSR item no.42.4 LED displaySupplying, Installation, Testing and Commissioning of following size LED display (LED monitor) industrial grade with 3840x2160 resolution or better, USB playback, Bluetooth and miracast connectivity, 4X HDMI 2.0, DP 1.2, HDR 10/10+, brightness: 500-nits or better, Video wall mode should be available, contrast ratio: 1200:1, OPS slot, viewing angle (H/V):170°/ 170°, response time less than 12ms, Display control shall be on monitor screen and programmable with remote (remote shall be supplied with system), Key Board, Optical Mouse, etc.as required.
1055 inch or larger
11DSR item no.40.12 Supplying, Installation, Testing and Commissioning following capacity Surveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications.
1210TB (Terabytes)
13DSR item no.39.1 Supplying, installation, Testing and commissioning of following capacity 8 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: Minimum 8 X RJ45 Gigabit Ethernet Ports and additional 2 X 1G SFP Ports with non-blocking architecture by having Switching capacity of minimum 20Gbps and packet forwarding rate of 14Mpps or higher, 8K MAC table. Internal dual AC Power supply with operating temperature of -5 0C to +50 0C. Jumbo frame: 9KB or higher, IGMP Snooping, IGMP snooping querier and support for IGMP Snooping Fast Leave, Should create 250 or more MLD groups, MLD Snooping, Per VLAN MLD Snooping C MLD Snooping Fast Leave, STP, RSTP, MSTP, Loopback detection, Multicast filtering, VLAN Tagging, ǪOS: 8 Ǫue per port, WRR, IPv4/IPv6 Interface : minimum 100 IPv4 static route entries and minimum 50 IPv6 static route entries, 700 Acess Control entries, SSH CSSL for IPv4 and IPv6, 802.1x, ARP Spoofing, DHCP Snooping and server screening, IP+MAC+Port Binding, Per Port Bandwidth Control, 802.1X Authentication (Supports local/RADIUS database, Port-based Access Control and EAP, OTP, TLS, TTLS, PEAP Support) Cable Diagnostic feature, LLDP, LLDP-MED, SNTP/NTP, RMON, SNMP v1,v2c, v3 and SNMP Traps. Certifications: FCC, CE marked, UL/EN, RoHS and relevant МТСТЕ (ТЕC)/BIS compliance/certification as applicable, etc. complete as required.
148 port PoE Layer 2 Network Switch with PoE Support of 130W or higher with each copper port supporting 802.3at PoE+.
15DSR Item no.39.3Supplying, installation, Testing and commissioning of following capacity 24 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking architecture by having Switching capacity of min. 128Gbps and packet forwarding rate of 95Mpps or higher, 16K MAC table. Console Port, USB port, Stacking support of min. 4 units per stack. Internal dual AC Power supply, STP, RSTP, MSTP, BPDU Filter, BPDU Restriction, Min. 9K Jumbo Frame, LBD, IGMP Snooping V1/V2/V3, MLD Snopping V1/V2. IGMP /MLD Groups 1K or more, IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6 ND, VRRPv3, UDP Helper, ECMP. VLAN: 802.1Ǫ, Port based, Ǫ-in-Ǫ, Multicast VLAN, Protocol VLAN, VLAN Trunking, DHCP Snopping, Server, server Screening. RADIUS , TACACS+ Authentication, ǪoS: 802.1P, 8 queues per port, ǪoS : WRR, Strict+WRR, WRED, 802.1p. ACL: MAC based, IPv4C IPv6, TCP/UDP Port number, time based ACL, TFTP Client, SNMP V1, v2c, v3, SNMP traps, RMON, DHCP server, relay, client, LLDP, LLDP-MED, OAM, Dying Gasp, 802.3ah, sflow, RIP, OSPF v2/v3, policy based route, SSL, SSH. 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. Certifications: FCC, CE marked Ul/EN, RoHs and relevant MTCTE (TEC)/ BIS complained certification as applicable etc complete as required
1624 port PoE Layer 2 Network Switch with PoE Support of 370W or higher with each copper port supporting 802.3at PoE+ min.
17DSR item no.39.23Supply and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U' Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required.
186U Rack
199U Rack
20DSR Item no.39.19Supplying and drawing following core Fiber Optic Cable having corrugated steel armoring. The Fiber should be SM Fiber Central -loose tube filled with Thixotropic jelly, duly following Standards: ISO 11801, IEC 60793-1/60794-1-2, ITU-T-REC G.652D and Telecordia GR-20-core, High quality Electro Chromium Coated Corrugated Steel tape (ECCS ) and HDPE- Sheath, Operating ambient Temperature should be – 5 0C to +50 0C and Storage Temperature shall be – 5 0C to +50 0C, Max Attenuation ± 0.36 (db / km) at Operational Wavelength 1310 nm and ± 0.22 db / km at Operational Wavelength 1550 nm. type of fiber should be 9/125 / G.652D & Refractive Index should be 1.4670/1.4675. The value for Mode-filed, Cladding Diameter 9.2 ± 0.4 μm and 125 ± 0.7 μm correspondingly. The Dispersion value < 3.5 < 18 ps/nm-km and PMD value < 0.2 ps/km and Cable Cutoff wavelength < 1260 nm i/c splicing & marking etc complete as required.
21Single Mode 6 Core Optical fiber cable
22Supply Installation Testing and Commissioning of SFP 1000 Base Fiber Module of Make Cisco / Alcatel / Extreme/ HPE/Juniper / Dlink only.
23DSR 39.12 Supplying, Installation, Testing and commissioning of following CAT6 Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required.
24Copper Patch Cords of length 1m (3ft)
25DSR 39.11 Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel. 24 Ports Cat-6 Patch Panel should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required.
26OFC CORDS: Supply Installation testing and Commissioning of OPTICAL FIBER EQUIPMENT CORDS (MINIMUM 2 METER ) SC-LC /SC -SC. All optical fiber patch leads shall comprise of Single-mode 9/125μm fiber OS2. Jacket should be anti-rodent and outer metal spiral sheath protection, Sheath: LSZH.Make: R&M / Systimax / Seimon / Molex /Dlink only.
27OPTICAL FIBER PIGTAILS: Supply Installation testing and Commissioning of OPTICAL FIBER PIGTAILS, 1.5 MTR SM OS2. Precision ferrule end face geometry SC Type SM. Factory polished tested and serialized. Buffer Diameter: 900um tight buffer. Minimum bend radius: install: 30 mm. Retention Strength: 100N. Cable: 900um Buffered. Sheath: LSZH.Make: R&M/DlinkSystimax / Seimon / Molex only.
28DSR item no.39.21Supply and fixing following port Rack Mount loaded LIU with pigtail, Front-mounted cable saddles for jumper management, suitable to manage both splices and terminations, Pre-assembled shelves in multiple configurations, Rubber fiber slotted bracket built-in, metal splice shelf to protect the fibers, 2 fiber spools built-in for 900μm tight buffered fiber storing, Capable of storing up to 3 meters of 900μm tight buffered fiber per adapter, Removable front and rear covers for better access to interior of LIU, Should be Single / Multi mode LC Type fully loaded. Accessory kit consists of cable ties, mounting ear screws, and spiral wrap tube etc complete as required.
296 Port LIU
3024 Port LIU
31DSR item no.26.1Online UPS - Input supply: Single Phase, Output Supply: Single Phase Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch alongwith for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion(ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 lagging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 deg C, Relative humidity 0-95% non condensing, noise level less than 60 db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge. Display for watt/VA, Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . The UPS should be with IGBT Based Inverter Technology, Communication RS232/RS485/SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accessories are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc
322 KVA
33Supply and erection of Steel Tabular Pole IS- 410 SP-6 swaged and welded in three steps 7.50mtr. Long weight 93 kgs as per IS 2713 (Part I & II 1980) amended upto date with the following specifications:-
34The pole shall have a sectional length of 4.50-1.50-1.50. Mtr.
35The outside diameter and thickness of each section shall be 114.30 mm x 5.40 mm, 88.9 mm x 4.85 mm and 76.1 mm x 3.25 mm.
36The circular base plate- 10G more than over all dia of bottom of the pole duly welded shall be provided.
37The pole shall be erected 1.25 meter below ground level in 10” internal diaready made RCC muff 1.25 Mtr. in length. The gap between the pole and muff shall be filled with cement concrete 1:2:4. The job includes the cost of cutting of road / pucca floor for erection of pole.
38The cost includes carriage, all labour and material including installation of Pole to the entire satisfaction of the Engineer-in-Charge.
39DSR item no.1.17Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
403 x 2.5 sq. mm
41DSR Item No.39.17Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required.
421 Run of cable
43DSR ITEM NO.1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
4425 mm
45Supplying and drawing of UTP 4 pair CAT 6 Armored outdoor Armouring: Corrugated Steel Tape Armour (ECCS Tape). Strength Member: Two Steel wires on periphery/Two FRPLAN Cable in the existing surface/ recessed Steel/ PVC conduit as required i)1 run of cable
46DSR item No.14.16 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
4763 mm dia ( OD-63 mm & ID-51 mm nominal)
48Providing AMC for CCTVs camases under the AMC the supplier shall provide comprehensive Mtc. of all equipment installed by the agency and there shall be no hidden cost. Preventive Mtc. Service of the equipment under AMC must be carried out once in fortnight during the period of AMC service / repair calls are to be attended by the supplier /agency with in 2 hours from the time of such calls. The defective equipment should be repaired on the same day at purchaser’s location. In case of major defects requiring the defective equipment to be taken to the supplied workshop if should be return with in weeks time duly repair and immigrate substituted equipment with the provided by the supplier for the smoothed operation. Delays in attended equipment the calls and or repairing the defective equipment beyond time limit of one day will attract penalty @500/- per day . the bidder will undertake the supplies of necessary Mtc. equipment .all the equipment and the complete system for a period of 5 years on continuing basis 1st year free and therefore for four years on paid basis. The bidder shall quote the rates on per year basis.
49For 2nd year
50For 3rd year
51For 4th year
52For 5th year Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57086046
AUTHORITY Local Bodies
TENDER VALUE 32.32 Lakhs
LAST DATE 26-08-2026
Authority
Authority Name Chandigarh Administration Engineering Department
Work Description Tender for Providing And Installation Of Cctvs Cameras At Block -B, Of Children Home, Snehalaya For Boys, Maloya, Chandigarh.
Basic Detail
Tender No E3/47W/116
Bidding Type Tender
Location
City Chandigarh
State Chandigarh
Key Dates
Publish Date 19 Aug 2026
Submission Date 26 Aug 2026
Open Date 26 Aug 2026
Finance
Tender Value 32.32 Lakhs
Tender Fee Ref. Documents
EMD 64700
Exemption Not Available
Document List
BOQ_116460.xls
d0cecb23-cc12-4a6b-8543-a958606a03b3.html
Tendernotice_1 (18).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 26, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Aug 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
xls

BOQ_116460.xls

html

d0cecb23-cc12-4a6b-8543-a958606a03b3.html

pdf

Tendernotice_1 (18).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders