Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Udhampur → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Upgradation Of Pwd Division Office Ramnagar.
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge All kinds of soil |
| 2 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil |
| 3 | Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked material : All kinds of soil |
| 4 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 5 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 6 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 7 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills, fillets etc upto floor V level, including curing but excluding the cost of centring, shuttering and finishing with. (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size |
| 8 | Providing and laying damp-proof Course 40 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete |
| 9 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete |
| 10 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing andreinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. All works upto plinth level |
| 11 | All works above plinth level upto floor V level |
| 12 | Add for plaster drip course/grooves in plastered surface or moulding to R.C.C. projections |
| 13 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth and above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for:Foundations, footings, bases of columns etc. for mass concrete. |
| 15 | Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 16 | Suspended floors, roofs, landings, balconies and access platforms. |
| 17 | Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 18 | Columns, pillars, piers, abutments, posts and struts. |
| 19 | Stairs (excluding landings) except spiral staircases. |
| 20 | Edges of slabs and breaks in floors and walls - Under 20 cm wide |
| 21 | Small surfaces such as cantilever ends, brackets and end of steps, caps and bases to pilasters and column and the like. |
| 22 | Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in superstructure above plinth level upto floor V level in cement mortar 1:4 (1 Cement : 4 coarse sand ) and curing complete. The rate includes providing and placing in position 2 nos. 6 mm dia M.S bars at every third course of masonry work. |
| 23 | Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in : Cement mortar 1:3 ( 1 cement : 3 coarse sand) |
| 24 | Extra for half Brick masonry in superstructure above plinth level upto floor V level. |
| 25 | Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxytouch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite of any colour or shade - (Area of slab upto 0.5 sqm) |
| 26 | Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. - Granite Work |
| 27 | Extra for providing opening of required size and shape for wash basin/ kitchen sink in kitchen platform, vanity counters and similar location in marble/granite / stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete |
| 28 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 29 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): In Second Class Deodar Wood |
| 30 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. : 4 mm thick glass pane (weighing not less than 10 kg/sqm) |
| 31 | Add for using 8 mm thick float glass |
| 32 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. : In Second Class Deodar Wood - 35 mm thick |
| 33 | Providing and fixing ISI marked flush door shutters conforming to IS: 22020 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters with ISI marked M.S.pressed butt hinges bright finished of required size with necessary screws : 35 mm thick |
| 34 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as perdirection of Engineer-in-charge : In Second Class Deodar Wood 35 mm thick |
| 35 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured) |
| 36 | Providing and fixing ISI marked oxidized M.S. door latches conforming to IS :5930 with screws etc. complete : 250x20x6 mm |
| 37 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 250x10 mm |
| 38 | 150x10 mm |
| 39 | 100x10 mm |
| 40 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.125 mm |
| 41 | 100 mm |
| 42 | Providing and fixing aluminum hanging floor door stopper, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : Twin Rubber Stopper |
| 43 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. With M.S. tube @10KG/SQM |
| 44 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. : In colour such as White, Ivory, Grey, Brown |
| 45 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including groutingthe joints with white cement and matching pigments etc. complete. :Size of tile 600x600 mm |
| 46 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement and matching pigments etc.complete. : Size of tile 600x600 mm |
| 47 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement: 3 fine sand) as per standard design. In 75x75 mm deep chase. |
| 48 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement: 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 49 | CEMENT PLASTER (IN COARSE SAND)12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 coarse sand) |
| 50 | CEMENT PLASTER (IN COARSE SAND 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 4 ( 1 cement : 4 coarse sand) |
| 51 | CEMENT PLASTER (IN COARSE SAND 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 coarse sand |
| 52 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) |
| 53 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ liter, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. : Two coat |
| 54 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content with ready mixed pink or grey primer on :Wood work (hard and soft wood) having VOC content less than50 grams/ liter |
| 55 | Wall surface having VOC content less than 50 grams/liter |
| 56 | Cement concrete 1:2:4 ( 1 cement :2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation, finishing and tamping complete. |
| 57 | Providing and Fixing Inaugural Stone of size 2’-0” × 3’-0” made of approved quality black granite stone of suitable thickness, machine cut and polished on front face, engraved with required inaugural matter/ information including lettering, logos and emblem (as approved), filled with enamel paint of approvedshade, fixed in position with cement mortar 1:3 over RCC/brick masonry backing, including necessary base support, edging, polishing, transportation, installation, curing and cleaning, complete in all respects as directed by the Engineer-in-Charge. |
| 58 | Carriage of Sand by mechanical transport @70km |
| 59 | Carriage of Aggrigate by mechanical transport @5km |
| 60 | Carriage of AAC Block by mechanical transport @50km |
| 61 | Carriage of Brick by mechanical transport @70km |
| 62 | ElectricalWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulatedcopper conductor single core cable etc. as required. Group A |
| 63 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 64 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 65 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 66 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 67 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.1 x 1.5 sq. mm |
| 68 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch |
| 69 | 3 pin 5/6 A socket outlet |
| 70 | 15/16 A switch |
| 71 | 6 pin 15/16 A socket outlet |
| 72 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 73 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 74 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm) |
| 75 | 3 Module (100mmX75mm) |
| 76 | 4 Module (125mmX75mm) |
| 77 | 6 Module (200mmX75mm) |
| 78 | 8 Module (125mmX125mm) |
| 79 | 12 Module (200mmX150mm) |
| 80 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 81 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 82 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugsto be used in non residential buildings). |
| 83 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 84 | Supplying & fixing suitable size GI box wih modular plate andcover in front on surface or in recess including providing andfixing 25 A modular socket outlet and 25 A modular DP MCB,\\"C\\" curve including connections, painting etc. as required |
| 85 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 4 way (4 + 12), Double door |
| 86 | 8 way (4 + 24), Double door |
| 87 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole 6 to 32 Amp |
| 88 | Single pole and neutral 6 to 32 Amp |
| 89 | Triple pole and neutral 6 to 32 Amp |
| 90 | Supplying and fixing following rating, Four pole, 415 V, 10 KaM.C.B in the existing MCB DB complete with connections,testing and commissioning etc. as required.Triple pole and neutral 40 to 63 Amp |
| 91 | Supplying and fixing single pole blanking plate in theexisting MCB DB complete etc. as required. |
| 92 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 93 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 94 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 95 | LED Batten light (System lumen efficacy ≥120 <135 lm/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as pe requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).36 watt |
| 96 | Supply installation testing and commissioning of Ceiling Fan 3Star Rated with Voltage Range 90 V to 300 V,Min. Air Delivery212 CMM,Service Value 5.3 Cu.m/min /watt, Aluminium Blades, including wiring the down rods of standard length(Upto 45 cm) with 1.5 sq.mm FR PVC insulated,copper conductor, single core cable including providing and fixing phenolic laminated sheet cover on the Fan Box etc as Required.1200 MM |
| 97 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt) Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120 deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 100 watt |
| 98 | LED Down lighter (SMD Type) (System lumen efficacy ≥120< 135lm/Watt) Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round /square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management : heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim . 18 watt |
| 99 | Supplying and fixing of following sizes Transair exhaust fan with metal blade complete set on existing holes on wall with necessary connection from ceiling rose to fan using 2 core flexible copper wire : 300mm/12\\" sweep exhust fan |
| 100 | SITC of Building Distribution Panel Indoor (IP:42) free standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/ switchgear c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar (>125). (d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge. |
| 101 | INCOMER100 A,36KA,FP MCCB |
| 102 | 200 A,36KA,FP MCCB |
| 103 | Aluminium Bus Bar 200 Amp set of 4 strips 18\\" |
| 104 | Digital Metering devices, comprising of Voltmeter, Ammeter,Selector Switch, Indicating Lamp, CT Set etc. |
| 105 | OUTGOINGSON Load Change Over Switch FP 100 amp. (Front operated) |
| 106 | 100 A,36KA,FP MCCB |
| 107 | Triple pole and neutral 63 Amp |
| 108 | Triple pole and neutral 32 Amp |
| 109 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 110 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in groundin Existing DWC Pipe including excavation, sand cushioning, protective covering and refilling the trench etc as required.3.5 C X 95 Sq.mm A2XFY |
| 111 | Supply and Making end Termination with Brass Compression Gland and Aluminium Lugs for the Following Sizes of PVC insulated and PVC Sheathed/XLPE Aluminium Conductor Cable of 1.1 KV Grade as Required (Comet)3½ X 95 sq. mm (45mm) |
| 112 | Supply installation testing and commissioning of 2.2 KVA Sine Wave Inverter , Input 1 Phase 3 wire and output 1 phase 3 wirewith 2 Nos of 12 V 200 aH Battery. |
| 113 | Plumbing and SanitationProviding and fixing white vitreous china pedestal type water closet(European type) with seat and lid , 10 liter low level white vitreous china flushing cistern and CP flush bend with fittings and C.I. brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid. |
| 114 | Providing and fixing Under Counter wash basin,with 32 mm WasteCoupling and other allied accessories including cutting and makinggood the walls wherever required:White Vitreous China Under Counter Wash basin |
| 115 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink with drain board 510x1040mm bowl depth 250mm |
| 116 | Providing and fixing white vitreous china pedestal type water closet(European type) wall hung including painting of fittings and brackets, cutting and making good the walls and floors wherever required: (For Specially Abled) W.C. pan with ISI marked white solid plastic seat and lid. |
| 117 | Providing and Fixing of 600 mm Grab Bar |
| 118 | Providing and Fixing of Foldable Grab Bar |
| 119 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:One urinal basin with 5 literwhite P.V.C automatic flushing cistern. |
| 120 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backingRectangular shape 1500x450 mm |
| 121 | Providing and fixing toilet paper holder with Flap made out of C.P Brass |
| 122 | Providing and fixing C.P Brass Soap Dish |
| 123 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto1 metre long with S.S. triangular plate to European type W.C. ofquality and make as approved by Engineer - in - charge |
| 124 | Providing and fixing CP brass towel rail complete with CP brackets fixed to wooden cleats with CP brass screws |
| 125 | Providing and fixing CP Short Body Bibcock with Valve Flange |
| 126 | Providing and fixing 15 mm nominal bore C.P. brass angle valve forbasin mixer and geyser points of approved make conforming to IS :8931 |
| 127 | Providing and fixing CP Brass Single lever telephonic wall mixer ofquality & make as approved by Engineer in charge. 15 mm nominal dia |
| 128 | Providing and fixing Stainless Steel Retractable Sink Basin Water Drain Pipe of approved quality & make and as per the direction of Engineer-incharge. (For Kitchen Sink) |
| 129 | Providing and fixing CP Brass Sink Mixer with Regular Swivel Spout of quality & make as approved by Engineer in charge. |
| 130 | Providing and fixing CP Brass 32mm size Bottle Trap of approvedquality & make and as per the direction of Engineer-in-charge. |
| 131 | Providing, laying and jointing 160 mm OD uPVC SWR Pipe, Type-B (Heavy Duty), conforming to IS: 13592:2013, with rubber ring socket joints (RRJ), including the cost of supply of pipes, special rubber lubricants, providing and fixing socketed ends, handling,transportation, and labor for proper jointing, as per technicalspecifications and direction of the Engineer-in-charge.110 mm diameter |
| 132 | 75 mm diameter |
| 133 | Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion.110 mm diameter |
| 134 | Providing and Fixing of Floor Traps 110 mm with double chrome plated Cover one Grated and one closed and all other fittings required. |
| 135 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarsesand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floatingcoat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :With common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 |
| 136 | Supply, Installation of PVC Gully Trap of Size 110 mm |
| 137 | Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms,lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. |
| 138 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20 cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m |
| 139 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of P.V.C pipes including bed concrete as per standard design :110 mm diameter |
| 140 | Providing and fixing Polyethylene- Aluminum- Polyethylene (PE-ALPE) Composite Pressure Pipes conforming to IS: 15450, U.V. stabilized with carbon black having thermal stability for hot and cold water supply, capable to withstand temperature upto 80ºC, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. Elbows, tees, reducers, couplers and connectors etc.This includes testing of joints complete as per direction of the Engineer-in-charge: Internal work-exposed on wall with clamps at 1.00 meter spacing 2025 (25mm OD) pipe |
| 141 | 4050 (50mm OD) pipe |
| 142 | Providing and fixing Polyethylene- Aluminum- Polyethylene (PE-ALPE) Composite Pressure Pipes conforming to IS: 15450, U.V. stabilized with carbon black having thermal stability for hot and cold water supply, capable to withstand temperature upto 80ºC, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. Elbows, tees, reducers, couplers and connectors etc.This includes testing of joints complete as per direction of the Engineer-in-charge: Internal work concealed with clamps at 1.00 meter spacingincluding cutting the chases and making good the wall etc. 1620 (20mm OD) pipe |
| 143 | 2025 (25mm OD) pipe |
| 144 | Providing and fixing Polyethylene- Aluminum- Polyethylene (PE-ALPE) Composite Pressure Pipes conforming to IS: 15450, U.V. stabilized with carbon black having thermal stability for hot and cold water supply, capable to withstand temperature upto 80ºC, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. Elbows, tees, reducers, couplers and connectors etc.This includes testing of joints complete as per direction of the Engineer-in-charge: External work including trenching and refilling etc. complete4050 (50mm OD) pipe |
| 145 | Providing and fixing unplasticised PVC connection pipe with brassunions:45 cm length 15 mm nominal bore |
| 146 | Cutting holes upto 30x30 cm in walls including making good the same with common burnt clay F.P.S.(non modular) bricks |
| 147 | Providing & fixing full way lever operated forged brass ball valve ofbrass body with forged brass hard chrome plated steel ball tested to a pressure not less than 16 Kg / sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc.25 mm Diameter |
| 148 | 50 mm Diameter |
| 149 | Fire FightingProviding, laying, testing & commissioning of 'C' class heavy dutyMS pipe conforming to IS 3589/IS 1239 including Welding, fittingslike elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixingthe pipe on the wall/ceiling with suitable clamp/support frame andpainting with two or more coats of synthetic enamel paint ofrequired shade complete as required :25 mm dia |
| 150 | 80 mm dia |
| 151 | 100 mm dia |
| 152 | Supplying and fixing single headed internal hydrant valve withinstantaneous Gunmetal/Stainless Steel coupling of 63 mm dia withcast iron wheel ISI marked conforming to IS 5290 (Type -A) withblank Gunmetal/Stainless Steel cap and chain as required :Single headed Gunmetal |
| 153 | Supplying and fixing orifice plate made out of 6 mm thick Stainlesssteel (Grade 304) with orifice of required size to be fitted betweenflange & landing valve of external and internal hydrants to reducepressure at the outlet to the level of 3.5 kg/cm2 complete asrequired. |
| 154 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63mm dia male and female couplings duly bound with GI wire, rivetsetc. conforming to IS 636 (type-A) as required :Gun Metal |
| 155 | Supplying and fixing first-aid Hose Reel with MS construction spraypainted in post office red,conforming to IS 884 complete with thefollowing as required. 20 mm nominal internal dia water hosethermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mmnominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30m |
| 156 | Supplying and fixing of fire brigade connection of cast iron bodywith gun metal male instantaneous inlet couplings complete withcap and chain as reqd. for suitable dia MS pipe connectionconforming to IS 904 as required :2way - 100 mm dia M.S. Pipe |
| 157 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge andpaintingwith synthetic enamel paint of approved shade as required. |
| 158 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20mm nominal internal diameter size nozzle conforming to IS 903suitable for instantaneous connection to interconnect hose pipecoupling as required :Gun metal |
| 159 | Providing and fixing Weather proof hose cabinets for yard hydrantfabricated from 16 g MS sheet with full glass door and lockingarrangement, suitable to accommodate one hydrant valve, 2nos.15m long hose, 1 No branch pipe and one fireman's axe. Thecabinet shall be painted with one coat of primer and finished stoveenamelled \\"Fire Red\\", \\"Fire Hose\\" written on front including suitablymounted on a raised masonry platform as required. (Approx0.75mx0.6 mx 0.25 m). |
| 160 | Providing and fixing standard fireman's axe with heavy insulatedrubber handle conforming to IS: 926 complete. |
| 161 | Supplying, installation, testing and commissioning of electric driventerrace pump suitable for automatic operation and consisting offollowing, complete in all respects, as required: (Terrace Pump) (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure,horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (d) Suitable cement concrete foundation duly plastered and with anti vibration pads.450 lpm at 35 m Head |
| 162 | Supplying,Installation,Testing and Commissioning of Cubical TypeOutdoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZAC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:55) (Terrace Panel). The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breake shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall beCPRI /ERDA/ANY NABL ACCREDITED LAB approved. Size of wiring for CTS:- 2.5 sqmmSize of wiring for voltage sensing Metering :-4.0 Sq.mmSize of wiring of all push buttons, indicating lamps:-1.5 Sq.mmTypes of wires:-PVC insulated 1100V grade ,Multistrand copperconductor Flexible FR-LSHHinged Door Earthing:-Device mounted hinged doors connected tocubicles body by means of 2.5 sqmm.green copper flexible wire .The Complete Panel Shall be Made out of 2.0 mm CRCA sheetincluding Frame/Partitions/Doors etc.Gland Plates to be 3.0 mm Thick. |
| 163 | INCOMERMCCB 63 A F.P 25 Ka with Adj. Thermal & Adj. magnetic releasewith Extendable ROH Icu=Ics=100% |
| 164 | Digital Metering Devices,comprising Voltmeter,Ammeter,SelectorSwitch,Indicating Lamps,C.T Set,Bus Bar(80 Amps ) and MCB Strip of suitable size as Required. |
| 165 | OUTGOINGSMPCB 19-25 A With STD. Magnetic Release |
| 166 | Power Contactor 40 A415 Volts, AC-3 Duty |
| 167 | Start/Stop Push Button 1 900 Set 900.00 |
| 168 | Supplying, fixing, testing and commissioning of butterfly valve ofPN 1.6 rating with bronze/gunmetal seat duly ISI marked completewith nuts, bolts, washers, gaskets conforming to IS 13095 offollowing sizes as required : 100 mm dia |
| 169 | Providing, installation, testing and commissioning of non-returnvalve of following sizes confirming to IS: 5312 complete with rubbergasket, GI bolts, nuts, washers etc.as required :100 mm dia |
| 170 | Providing, installation, testing and commissioning of stainless steelY-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304,sheet with 3 mm dia holes with stainless steel flange.100mm dia |
| 171 | Providing & fixing of pressure switch in M.S. pipe line includingconnection etc. as required. |
| 172 | Providing, installation, testing and commissioning of PressureGuages |
| 173 | Supplying,Installation,Testing and Commissioning of MAP 90 ABCType Fire Extinguisher 4.0 Kg. Capacity ISI Mark(IS:15683)suitablefor Class A/B/C Type Fires . |
| 174 | Supplying,Installation,Testing and Commissioning of CO2 TypeFire Extinguisher 4.5 Kg. Capacity ISI Mark(IS:15683)suitable forClass A/B/C Type Fires . Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 11, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 22 daysSep 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender