Tender For Annual Plan-Kuzhimanna Grama Panchayat Minimast Lights Repair At Neeruttikkal Angadi-So 101/27-General Electrical Work
Tender Overview
Project Description
Tender for Annual Plan-Kuzhimanna Grama Panchayat Minimast Lights Repair At Neeruttikkal Angadi-So 101/27-General Electrical Work , Wiring , 90.15.4.8:Supply Conveyance, Installation, Testing And Commissioning Of 120W Led Flood Light Output Greater Than 105Lumen/W 4000-6000 K With Ip 66 Protection Led Chip Make Cree/Lumilled/Nichea With Power Factor Greater Than 0.95 At Full Load, Internal Surge Protection Up To 8 Kv,And Aluminium Pressure Die-Cast Powder Coated Housing, Acrylic Cover Complete With Thd Less Than 10%, Power Factor Greater Than 0.98, Rohs Compliant, Duly Wired Up For Use On 230 V Ac Supply. Driver Compartment Should Be Seperatly Accessible For Maintenance (Lm 79&80 Certificates From Nabl Accredited Third Party Lab To Be Produced Mentioning Chip Manufacturer) , 1.17.1:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.1 X 1.5 Sq. Mm , Od99176/2026-2027: Supply Conveyance, Installation, Testing And Commissioning Of Digital Time Switch Relay 230V Ac Contact1 Construction of Spdt, Relay Rating 16A / 20 Mounting On Din Rail Mount Including Connections Etc As Required , 2.10.3:Supplying And Fixing 5A To 32 A Rating, 240/415 Volts, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Double Pole , 2.12.1:Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps , 2.14.2:Supplying And Fixing Following Rating, Double Pole, (Single Phase And Neutral),240 Volts, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Milli Amperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Od99177/2026-2027:Dismantling The Existing Damaged Flood Lights, Timer, Isolator, Rccb Etc From Pole Conveyed And Handed Over To The Agreement Authority With Reciepts , Od104695/2026-2027:Supply And Installation Of Dust And Vermin Proof Syntax Junction Box( Gs-Jb-3425-Nf ] And To Fix Fuse Units, Ct, Dp Mcb Etc As Required Including Fixing It On Wall, Making Good The Damages Colour Washing Etc. As Required
BOQ
| Sl. No. | Item Description |
| 1 | wiring |
| 2 | 90.15.4.8:Supply Conveyance, installation, testing and commissioning of 120W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 3 | 1.17.1:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x 1.5 sq. mm |
| 4 | OD99176/2026-2027: Supply Conveyance, installation, testing and commissioning of Digital Time Switch Relay 230V AC Contact1 C/O SPDT, Relay Rating 16A / 20 Mounting on DIN Rail Mount including connections etc as required |
| 5 | 2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Double pole |
| 6 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 7 | 2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 8 | OD99177/2026-2027:Dismantling the existing damaged flood lights, timer, Isolator, RCCB etc from pole conveyed and handed over to the agreement authority with reciepts |
| 9 | OD104695/2026-2027:Supply and installation of dust and vermin proof Syntax Junction box( GS-JB-3425-NF ] and to fix fuse units, CT, DP MCB etc as required including fixing it on wall, making good the damages colour washing etc. as required Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender