Tender For Special Repair To Security Lights From Div Rear Gate To Nair Gate And Tigertrail Under Age E/M Of Ge 862 Ews
Tender Value
19.40 Lakhs
Estimated cost
Bid Submission
09 Sep 2026
16 days left
EMD
39000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Rajouri → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repair To Security Lights From Div Rear Gate To Nair Gate And Tigertrail Under Age E/M Of Ge 862 Ews
BOQ
| Sl. No. | Item Description |
| 1 | M&L for dismantling of LT steel/ PCC pole, complete all as specified and directed. |
| 2 | M&L for dismantling of cross-arms of M.S. channel or angle sections etc, complete all as specified and directed. |
| 3 | M&L for dismantling of ACSR or AAC conductors, complete all as specified and directed. |
| 4 | Supply, laying and testing of cable XLPE insulated, galvanised steel strip armoured,1100 volts grade with multistranded aluminium conductor of cross-sectional area 35 sqmm; 3.5 core laid in trenches/pipes/ducts/walls and connection with necessary cable lugs and glands, nuts, bolts and washers etc and testing, complete all as specified and directed. |
| 5 | Supply, laying and testing of cable XLPE insulated,galvanised steel strip armoured,1100 volts grade with multistranded aluminium conductor of cross-sectional area 25 sqmm; 4 core laid in trenches/pipes/ducts/walls and connection with necessary cable lugs and glands, nuts, bolts and washers etc and testing, complete all as specified and directed. |
| 6 | Supply, laying and testing cable XLPE insulated, screened, PVC bedded, Galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm, 4 core laid in trenches/ pipes/ ducts/ walls and making cable connections by providing cable lugs and glands, complete all as specified and directed. |
| 7 | Supply and fix in replacement LED street light fitting 60 watts, made in pressure diecast housing with epoxy powder coated dark graphite grey colour finish.prismatic polycarbonate cover with individual LED lenses with IP 65 complete with all accessories and necessary fixing arrangement on wall at any height including three core 0.5 sqmm copper cable from connector to fitting and removing old unserviceable item, complete all as specified and directed. |
| 8 | Supply and erecting in true vertical position steel tubular swaged pole, 9 metre long, complete with mild steel base plate 6mm thick of size 300mm x 300mm, B-118 finial taper plug, bolts, nuts, washers and screws, type 410 SP-31 including drilling of holes of required size and nuts for fixing of cross arms, painting with two coats of aluminium paint over a coat of red oxide primer and two coats of black bituminous paint for portion embedded in concrete, painting five black and white bands at lower portion of pole each of 300 mm height at 300mm spacing, complete all as specified and directed. |
| 9 | Supply and fix GI bracket pipe of size 50 mm dia light grade of 1.2 mtr long bent to shape hot or cold suitable for street light fitting and making the one end of GI pipe bracket suitable for fixing of street light fittings of any type and the GI bracket pipe shall be fixed on wall/pole surfaces by providing suitable MS iron clamps 2 nos of length as required at site to the bracket pipe and painting to MS clamps with synthetic enamel paint and fixing with necessary suitable nuts, bolts & washers, complete all as specified and directed. |
| 10 | Supply and fix FRP looping box of size 300x200x105 mm with 3 phase & Neutral with bus bar and comprising of MCB SP 6 Amps, ISI marked,240V complete with and including providing GI clamps,nuts bolts etc suitable for fixing on PCC pole/ wall/steel tubular pole etc and including removing old unserviceable item, complete all as specified and directed. |
| 11 | Supply and fix copper conductor cable, PVC insulated, sheathed,flexible, multistranded,ISI marked, 1100 volts grade, 3 core, 1.5 sqmm and including PVC conduit pipe of 20mm dia, complete all as specified and directed. |
| 12 | Excavation in trenches not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying of cables, pipe lines, protection pipes and foundations etc and getting out in soft/ loose soil, complete all as specified and directed. |
| 13 | All as per Item No 12.00 here-in-before but depth exc. 1.5m and n. exc. 3.00m deep. |
| 14 | Returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm, complete all as specified and directed. |
| 15 | Removing excavated soil not exc 50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and directed. |
| 16 | M&L for double wall corrugated pipe (DWC) of 75mm dia IS 16205 Part 24 and IEC 61386 (Part 24) for cable protection under/above ground, complete all as specified and directed. |
| 17 | M&L for PCC 1:4:8 (nominal mix) type D-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete for poles and stay/installation paths, complete all as specified and directed. |
| 18 | M&L for PCC 1:3:6 (nominal mix) type C1 (using 20mm graded crushed stone aggregate) as in coping of poles and the like complete including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 19 | Supply and laying GI pipe 50mm dia light grade in any length with all GI fittings such as socket, elbow, bend, union, Tee etc laid in trenches/duct/culvert/road crossing etc for protection of cables, complete all as specified and directed. |
| 20 | Supply and laying GI pipe 80mm dia light grade in any length with all GI fittings such as socket, elbow, bend, union, Tee etc laid in trenches/duct/culvert/road crossing etc for protection of cables, complete all as specified and directed. |
| 21 | M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically Each Set to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with a 15 cm thick layer of char coal dust and common salt, earth lead GI strip 32 x 6 mm by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth strip connected to main switch board and protected by galvanized iron pipe light grade 40 mm bore and water pipe 20 mm bore Gl light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-1 & RCC cover, 40mm thick all as specified & shown in elect plate No. 3 of SSR part I of 2010, complete all as specified and directed. |
| 22 | Design, supply, erection, testing and commissioning of outdoor type LT Feeder Pillar of overall size not less than 1050mm width x 800mm Height (With Canopy & Base Channel) x 400mm Depth, M.S. Channel Base Frame mounted (to be mounted on the 3 side covered brick. pedestal of height 900mm above ground level) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 100 amps, Provision of Spreader link to incoming side of MCCBs for termination of cables and 4 way ebonite cable connector (rating 32 amps) for termination of outgoing cables with MCBs.TheFeeder Pillar shall be duly fabricated in a approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.15mm thick CRCA mild steel sheet and 3.15mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be comprising of the followings :- Location : STREET LIGHT CONTROLLER |
| 23 | PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided in the bottom for both incoming and outgoing cables. BUS BARS & INTERNAL CONNECTIONS :- The bus bars should be made of Aluminium, duly insulated with 1100 volts grade standard colour coded heat shrink type PVC sleeves and rigidly mounted on suitable size 'F' class insulators of non hygroscopic non combustable, track resistant,high strength FRP / SMC / DMC material. 4 Nos Aluminium bus bars of rating 100 amps, . For all internal connections from main bus bars to switch gears shall be carried out with suitable size FRLS grade PVC insulated multiflexible type copper wire as per the current carrying capacity of individual switch gears. Earthing bar shall be provided as per standard practice and shall be made of Galvanized Steel flats of size 25mm x 6 mm.CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched,tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges.INCOMING :- 4 pole MCCB ( with panel mounted rotary handle ) having breaking capacity 16 KA Fixed magnetic and Fixed thermal setting of rating 63 Amps. -01 NoMake : LEGRAND /SCHNEIDER / ABB.OUTGOINGS :- (i) MCB 40 Amp,TPN,04 POLE having breaking capacity 16 KA -02 Nos Make : LEGRAND /SCHNEIDER / ABB |
| 24 | STREET LIGHT CONTROLLERThis should be made of the following articles complete with all wiring harness as required :-(i) 3 Pole power contactor, suitable for 415 volts AC 50 Hz supply and current carrying capacity 40 Amps. - 01 No.Make : L&T (ML-3) / BCH / TC.(ii) DIN rail mounted, Astronomical Time Switch, 1 Channel, suitable for operate in 230 volts AC 50 Hz supply and operating mechanism based on sun rise / sun set timing of a preset lattitude and longitude of a particular location - 01 No.Make : LEGRAND (Cat No. - 412654 Alpharex D21 astro) OR Equivallent model in SCHNEIDER.(iii) 6 Amps rated Rotary type selector Switch for Auto / Manual Selection - 01 No. Make : KAYCEE / L&T / C&S (RAAS).MISCELLANEOUS ITEMS :- (a) SP MCB 6 Amps 10 KA (For Control Wiring) - 01 No. Make : LEGRAND /SCHNEIDER / ABB.(b) Danger Notice Plate duly written in Signal Red colour on Aluminium plate in English & Hindi language and of size not less than 150mm x 100mm - 02 Nos. |
| 25 | Note for Item Nos.1) All incoming & outgoing feeders to be marked with aluminium name plates duly rivetted on the front inner door of the feeder pillar.2) All the cable entry / exit will be through bottom only, duly glanded with single compression type brass cable gland of suitable size. Cost of end termination of cable shall deemed to be included in the cost of feeder pillar.3) All the inner / outer doors should have locking facility through castle locks4) Cost of all civil work for brick pedestal, duly plastered, shall deemed to be included in the unit rate quoted, no separate payment shall be allowed for this. 5) The dimention of Panel Board as mentioned above is tentative. If it is required to be enhance to accomodate the switchgears and maintaining the gaps as per IE Rules, it shall be enhanced as per requirement without any extra cost to the department.6) The thickness of MS Sheet for outer shell and canopy shall be of 3.0mm and inner doors and partitions shall be of 2.0 mm7) The Panel Board shall be designed in such a way that adequete workable space is made available inside every compartments.8) The drawing of the Panel Board shall have to be got approved by Garrison Engineer before starting of fabrication process. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysSep 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender