Banking and Finance Government Departments Closing in 13 days TDR #57085072

Tender For Electrical Work For The Staff Canteen In The Banks Office Building At Bkc

Issued by Government Departments · Mumbai Suburban, Maharashtra
Tender Value
13 Lakhs
Estimated cost
Bid Submission
18 Sep 2026
13 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai Suburban → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Electrical Work For The Staff Canteen In The Banks Office Building At Bkc

BOQ

Name of Work:- Electrical work for the Staff Canteen in the Banks Office Building at BKC
Sl. No. Item Description
1MCCBDB: Main DB Supply, Installation, Testing and commissioning of approved make 12 Way, VTPN double door (metallic door) MCCBDB (IP 43) complete with 250 A Copper Busbar for each phase, 2 Neutral bar, 2 Earth bar and Cable ties for Cable management and fully insulated busbar & shrouded Neutral bars, required hardwares for mounting of MCBDB on wall with MS angle frame of minimum 35 mm x 35 mm x 5 mm size and required hardwares and following accessoriesIncomer:FPMCCB Qty 01 No.Rated current: 160 AmpCategory: 36 KA Thermal and Magnetic O/L and SC protection, Outgoing, “C” curve MCBs:TPMCB 32 Amp Qty 09 Nos.TP MCB 63 Amp Qty 02 Nos.SP MCB 63 AMP Qty 03 Nos.
2Cable End box:Supply and Installation of respective make metallic cable end box suitable for above 12 Way VTPN MCCBDB stated at Sr. No. 1 of this BOQ.
3MCBDB: Lighting and RAW Supply, Installation, testing and commissioning of approved make 8 Way, per phase isolation, ETPN PPI double door (metallic door) MCBDB (IP 43) complete with minimum 100 A copper busbar for each phase, neutral bar, earthbar and cable ties for cable management, fully insulated busbar & shrouded neutral bars, per phase isolation kit, required hardwares for mounting of MCBDB and following respective make ‘C’ curve MCBs, RCCBs on wall, with MS angle frame of minimum 35 mm x 35 mm x 5 mm size and required hardwares and following accessoriesIncomer:FPMCB 63 Amp Qty 01 No.Outgoing:RCCB (two pole two module) 40 Amp 100 mAmp Qty 03 NosSPMCB 6 Amp to 32 Amp Qty 18 Nos.
4Cable End box: Supply and Installation of respective make metallic cable end box suitable for above 8 Way ETPN MCBDB stated at Sr. No. 3 of this BOQ.
5MCBDB: Critical Load Raw PowerSupply, Installation, testing and commissioning of approved make 8 Way, SPN double door (metallic door) MCBDB suitable for flush mounting and surface mounting complete with minimum 100 A copper busbar for each phase, neutral bar, earthbar and cable ties for cable management, fully insulated busbar & shrouded neutral bars, required hardwares for mounting of MCBDB and following respective make ‘C’ curve MCBs, RCCBs.Incomer:RCCB (two pole two module) 40 Amp 100 mAmp Qty 01 No.Outgoing:SPMCB 16 Amp to 32 Amp Qty 06 Nos.
6Cable End box:Supply and Installation of respective make metallic cable end box suitable for above 8 Way SPN MCBDB stated at Sr. No. 6 of this BOQ.
7Supply, Installation, testing and commissioning of approved make C series 32 Amp FPMCB in respective make metal enclosure in surface manner
8PVC conduits:Supply and laying of approved make HMS grade of minimum 25 mm size PVC conduit along with required pipe fittings including required support, on wall in surface manner for vertical drop/horizontal looping of wiring upto MCBDB and on wall in concealed manner by providing chase cutting in wall for installation of PVC conduit and refilling the gap surrounding it by mortar making the good damages for vertical drop of wiring upto switch plates and on true ceiling in surface manner with required saddle and hardwares as directed by Bank’s Engineer as per site conditions.
9Circuit wiringSupply, Installation, Testing and Commissioning (SITC) of approved make 3 Nos. 2.5 Sq mm copper conductor Heat resistance Flame retardant Low smoke Halogen (HR-FR-LSH) insulated wire (Red/Yellow/Blue colour for Phase, Black colour for Neutral and Green colour for earth) partly in existing floor trunking/ PVC conduits from MCBDB to switch boards/ switch board to switch boards.
10Primary point:Supply, Installation, Testing and Commissioning (SITC) of approved make 3 Nos. 1.5 Sq mm copper conductor Heat resistance Flame retardant Low smoke Halogen (HR-FR-LSH) insulated wire (Red/Yellow/Blue colour for Phase, Black colour for Neutral and Green colour for earth) partly in approved make minimum 1” dia HMS grade PVC conduit with required support from true ceiling, vertical drop from PVC junction box to light fitting/exhaust fan in suitable size approved make FRLS PVC flexible conduit & with required PVC accessories and from existing SPMCB in MCBDB or existing switches of switch plates as per site conditions. The wires shall be terminated in switches and in mechanical connector near lights/providing new three plate ceiling rose near exhaust fan. Approximate average length of the wiring per point is of 11 Mtrs.
11Secondary Point Supply, Installation, Testing and Commissioning (SITC) of approved make 3 Nos. 1.5 Sq mm copper conductor Heat resistance Flame retardant Low smoke Halogen (HR-FR-LSH) insulated wire (Red/Yellow/Blue colour for Phase, Black colour for Neutral and Green colour for earth) partly in approved make minimum 1” dia HMS grade PVC conduit with required support from true ceiling, vertical drop from PVC junction box to light fitting in suitable size approved make FRLS PVC flexible conduit & PVC accessories, from primary light point to secondary light point and so on light point. The wires shall be terminated in mechanical connector near lights. Approximate average length of the wiring per point is of 5 Mtrs.
1216 Amp LED Indicator switchSupply, installation, testing and commissioning of approved make one no., minimum 16 Amp LED indicator switch, with respective make and model mounting plate and metal box in concealed manner by making required opening in wall and refilling the area surrounding it with mortar and making the good damages, required hardwares, etc. Rates shall be inclusive of termination of circuit wiring in switch and earth connectivity to metal concealed box.
136/16 Amp SocketSupply, installation, testing and commissioning of approved make one no., minimum 6/16 Amp socket with respective make and model mounting plate and metal box in concealed manner by making required opening in wall and refilling the area surrounding it with mortar and making the good damages, required hardwares, etc. Rates shall be inclusive of termination of circuit wiring in sockets and earth connectivity to metal concealed box.
14RAW Supply Light Plug Point Supply, installation, testing and commissioning of approved make two nos. minimum 6 Amp socket, two nos. minimum 6 Amp switch, respective make and model mounting plate and metal box in concealed manner by making required opening in wall and refilling the area surrounding it with mortar and making the good damages, required hardwares, switch socket looping wires etc. Rates shall be inclusive of termination of circuit wiring in switch sockets and earth connectivity to metal concealed box.
15RAW Supply Light Plug Point Supply, installation, testing and commissioning of approved make one no. minimum 6/16 Amp socket, one no. minimum 16 Amp LED Indicator switch, respective make and model mounting plate and metal box in concealed manner by making required opening in wall and refilling the area surrounding it with mortar and making the good damages, required hardwares, switch socket looping wires etc. Rates shall be inclusive of termination of circuit wiring in switch sockets and earth connectivity to metal concealed box.
16Lighting switchboardSupply, installation, testing and commissioning of approved make three nos. of minimum 6 Amp respective make and model mounting plate and metal box in concealed manner by making required opening in wall and refilling the area surrounding it with mortar and making the good damages, required hardwares, switch socket looping wires etc. Rates shall be inclusive of termination of circuit wiring in switch and earth connectivity to metal concealed box.
17Lighting switchboardSupply, installation, testing and commissioning of approved make four nos. of minimum 6 Amp respective make and model mounting plate and metal box in concealed manner by making required opening in wall and refilling the area surrounding it with mortar and making the good damages, required hardwares, switch socket looping wires etc. Rates shall be inclusive of termination of circuit wiring in switch sockets.
18Telephone cabling:Supply & laying of approved make four pair, Cat 6 conductor PVC insulated PVC sheathed Telephone cable in suitable PVC conduits from Telephone MDF from nearest MDF to respective telephone point.
19Telephone Socket:Supply & Installation of approved make RJ-11 Telephone Socket Qty 02 Nos with respective make plastic white Plate, surface PVC/metal box and required hardwares as directed by Bank’s Engineer as per site conditions.
20Cabling work: Supply and laying of approved make copper / aluminium conductor, 650/1100 Volt grade following sizes FRLS XLPE insulated armoured cables having sector / circular shaped copper conductor PVC insulated cores, laid up, PVC tape wrapped inner sheathed, GI strip / wire armoured and overall extruded PVC sheathed confirming to IS: 1554, partly on wall/ceiling with required size heavy duty GI saddle/clamp, partly on existing cable tray.
214C x 50.0 Sq mm (Aluminium)
224C x 10.0 sq mm (Copper)
234C x 6.0 sq mm (Copper)
244C x 4.0 Sq mm (Copper)
253C x 4.0 Sq mm (Copper)
26Termination of cables:Supply & Installation of end termination of following sizes armoured cables including compressed type brass glands, crimping type copper / Aluminium lugs, insulation tape etc. as 'required complete with earthing of glands
274C x 50.0 Sq mm (Aluminium)
284C x 10.0 sq mm (Copper)
294C x 6.0 sq mm (Copper)
304C x 4.0 Sq mm (Copper)
313C x 4.0 Sq mm (Copper)
32GI Earth Wire:Supply and installation of 10 SWG GI earth wire with tie band at required interval preferable minimum one at one feet length of cable.
33Hanging lights:Supply, Installation, Testing and Commissioning of approved make minimum 14 Watt, minimum 90 lumens / watt LED hanging/pedndant lights with required support from true ceiling / false ceiling, and gear wire assembly and main support from true ceiling, as directed by Bank’s Engineer as per site condition.
34LED downlighter:Supply, Installation, Testing and Commissioning of approved make wireless remote operated round shape LED dimmable and tuneable downlighter of minimum 18 watt, minimum 100 lumens per watt, white colour body
35LED Linear light fitting:Supply & Installation of approved make minimum 40 Watt, 1200 mm, minimum 100 lumens per watt aluminium body LED linear light fitting with required hardwares and gear wire set and main support from true ceiling.
36Supply, Installation, Testing and commissioning of approved make LED rope light of 8 Watt per mtr, 700 Lumens per watt, 120 LED per mtr.
37Supply, Installation, Testing and Commissioning of approved make Direct Online (DOL) starter suitable for 5 HP 3 Phase 415 Volt 50 HZ Induction motor having overload range suitable for motor current.
38Cable Tray:Supply and installing 150 mm x 50 mm x 1.6 mm size of perforated Hot deep Galvanized Iron cable tray (Galvanization thickness not less than 50 micron), bend, Tees, cross members, reducer etc, with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from ceiling with GI suspenders including G.I. bolts and nuts etc as required.
39Rebate for carefully dismantling of existing old electrical wiring, conduits, cables, switchboards etc and taking away. The lighting fixtures shall be handed over to bank. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57085072
AUTHORITY Government Departments
TENDER VALUE 13 Lakhs
LAST DATE 18-09-2026
Authority
Authority Name reserve bank of india
Work Description Tender For Electrical Work For The Staff Canteen In The Banks Office Building At Bkc
Basic Detail
Tender No RBI/Mumbai Regional Office/Estate BKC/26-27/1
Bidding Type Tender
Location
City Mumbai Suburban
State Maharashtra
Key Dates
Publish Date 18 Aug 2026
Submission Date 18 Sep 2026
Open Date 21 Sep 2026
Finance
Tender Value 13 Lakhs
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
a9faf44c-851d-4ab9-a82c-09f52df255e6.html
BOQ_335809.xls
Tender.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Sep 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
html

a9faf44c-851d-4ab9-a82c-09f52df255e6.html

xls

BOQ_335809.xls

pdf

Tender.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders