Tender for Tender for Maintenance Work Of Ht/Lt Line In The Area Of A.E. (Tech)-Surendra Nagar, Muzaffarnagar Under Eudd Technical Muzaffarngar Maintenance Work Of Ht/Lt Line In The Area Of A.E. (Tech)-Surendra Nagar, Muzaffarnagar Under Eudd Technic
Tender Overview
Project Description
Tender for Maintenance Work Of Ht/Lt Line In The Area Of A.E. (Tech)-Surendra Nagar, Muzaffarnagar Under Eudd Technical Muzaffarngar Maintenance Work Of Ht/Lt Line In The Area Of A.E. (Tech)-Surendra Nagar, Muzaffarnagar Under Eudd Technical Muzaffarnagar
BOQ
| Sl. No. | Item Description |
| 1 | Carriage of all pettey material of estimate from JE Store/Electricity Store Center, Muzaffarnagar to site of work with loading and unloading at both ends on Kachha Packka road. |
| 2 | STP Pole 11/13 mtr |
| 3 | PCC Pole 8.5/9 mtr |
| 4 | PCC Pole 11 mtr |
| 5 | ACSR Conductor (Dog, Weasel, Rabbit) |
| 6 | ABC Conductor (all sizes) |
| 7 | 11 KV XLPE Cable (3x35-3x70+3x120-3x185-3x300sqmm) |
| 8 | 33 KV XLPE Cable (3x185/240/300 Sqmm) |
| 9 | Re-straightening of Tilted Pole after digging of pit of suitable size Adjacent per RESPO/Norms and as per direction of site incharge. |
| 10 | Cutting of tree branches along the route of the line and disposal of the same at suitable places and as per direction of site incharge. |
| 11 | Repair and replacement of damaged stay and concreting of stay with all accessories complete in all respect as per RESPO/Norms and as per direction of site incharge. |
| 12 | Guarding of 11KV Line, repair of damaged guarding with all accessories complete in all respect as per RESPO/Norms and as per direction of site incharge. |
| 13 | Repairing of broken/rusted pole at site by digging the base of round pole/joist approx. 3' depth straightening of pole in rest position by welding work including dismantling of L.T/H.T. line sagging and resagging after welding & refling the base of pole with sand, concrete and cement. Welding work by providing 1 mtr. long four pieces of M.S Angle 50x50x6 mm and 2 nos. M.S. Round ring in each pole of 12 mm thick for smooth working and Grouting of the same pole/supports in CC 1:4:8 (Cement, sand & 40mm brick ballast) Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, up to ground level, 300mm plinth above the ground level with CC 1:3:6 (Cement, core sand and Stone grit) with mufting as per RESPO norms, work includes back filling & proper ramming by providing all required grouting materials, as per direction of site incharge. All the material requried for above work will be provided by contractor. |
| 14 | Erection, Fixing and Grouting of PCC Pole 8.5 mtr. long in LT. line after digging of suitable pits including fixing of requisite accessories as per RESPO Norms by providing L.T. Pin Clamps, M.S. Flat of size 50x6 & shackle Insulator of size 75x90mm, with proper size nuts and bolts. |
| 15 | Erection, Fixing and Grouting of PCC Pole 8.5 mtr. long in 11 KV line after digging of suitable pits including fixing of requisite accessories as per RESPO Norms by providing F-Bracket made of M.S. Flat of size 65x6 mm, Cross Arm holding Clamps made of M.S. Flat of size 65x6 mm with proper size nuts and bolts. |
| 16 | Filling of 11 KV/33 KV XLPE straight through cable jointing kit |
| 17 | Filling of 11 KV/33 KV XLPE Indoor/Outdoor cable jointing kit |
| 18 | Erection, Fixing and Grouting of PCC/ST. Pole in 11 KV line after digging of suitable pits including fixing of requisite accessories as per RESPO Norms by providing F-Bracket made of M.S. Flat of size 65x6 mm, Cross Arm holding Clamps made of M.S. Flat of size 65x6 mm with proper size nuts and bolts. |
| 19 | PCC Pole 11 Mtr. |
| 20 | S.T. Pole 11/13 Mtr. |
| 21 | Erection, Fixing and Grouting of following pole in 33 KV line after digging of suitable pits including fixing of requisite accessories as per RESPO Norms by providing F-Bracket made of M.S. Flat of size 65x8 mm, Cross Arm holding Clamps made of M.S. Flat of size 65x8 mm with proper size nuts and bolts. |
| 22 | PCC Pole 11 Mtr. |
| 23 | S.T. Pole 11/13 Mtr. |
| 24 | Grouting of following PCC/STP Pole supports in CC 1:4:8 (Cement, sand & 40mm brick ballast) Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, up to ground level, 300mm plinth above the ground level with CC 1:3:6 (Cement, core sand and Stone grit) with mufting as per drawing, work includes back filling & proper ramming by providing all required grouting materials. |
| 25 | Grouting & fixing of stay rods (20x1800)mm including all work of excavation, cement concrete in size (0.60x0.60x0.30)m in ratio 1:4:8 cement, sand, 40mm brick ballast as per drg. Including back filling, proper ramming etc and fixing tightening & nozzling of stay wire with stay rod with the poles of required tension as per drawing as per RESPO Norms by providing all grouting material and stay clamp/stay insulator made of M.S. Flat of size 50x6mm with proper size bolts & nuts & loops. |
| 26 | Earthing of supports with MS earth Rod of (20x2500)mm long including excavation of pit and driving M.S. Rod 3.0 M apart from support and 0.5m below the ground level and connection below the earth electrodes with the help of G.I. wire & earthing lugs as per RESPO Drawing/Norms by providing proper size nuts & bolts, lugs and GI wire. |
| 27 | Dismantling & removal of existing ACSR Conductor of all size and opening of all accessories and bundling the same at various places. |
| 28 | Stringging, Saggging of old loose ACSR Conductor and binding from insulator & proper completion of work as per RESPO/Drawing Norms. |
| 29 | (a) ABC Conductor (all sizes) |
| 30 | (b) ACSR Weasel Conductor |
| 31 | (c) ACSR Rabbit Conductor |
| 32 | (d) ACSR Dog Conductor |
| 33 | Replacement & fixing of damage X-Arm of 11 KV /33 KV Line by providing all necessary clamp and nut bolts |
| 34 | Replacement & fixing of damage 11 KV Disc Insulator of 11 KV/33 KV Line. |
| 35 | Dismantling & Removal of old and used STP (Scrap)/PCC Pole, after digging of pit of suitable size and removal of all accessoires as per RESPO/Drawing Norms. |
| 36 | Laying Stringging & Saggging of new ACSR Conductor and binding from insulator & proper completion of work as per RESPO Norms. |
| 37 | (a) ABC Conductor (all sizes) |
| 38 | (b) ACSR Weasel Conductor |
| 39 | (c) ACSR Rabbit Conductor |
| 40 | (d) ACSR Dog Conductor |
| 41 | Carriage of old & damaged STP Scrap Pole, from site of work to JE Store/Electricity Store Centre Muzaffarnagar including loading and unloading at both the ends on Kachha and Packka road. |
| 42 | Carriage of old & damaged scrap ABC/ACSR Conductor, from site of work to Electricity Store Centre Muzaffarnagar including loading and unloading at both the ends on Kachha and Packka road. |
| 43 | Jumpering work properly of 11 KV & 33 KV line as per RESPO/Norms. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender