Tender For Annual Rate Contract For The Work Of Construction And Commissioning Of Bore Hole By Dth/Rotary/ Combination Rig Of 200 Mm Dia, Supply And Installation Of Energy Efficient Submersible Pump Sets, Panels, Cables And Other Allied Works Includi
Tender Overview
Project Description
Tender for Annual Rate Contract For The Work Of Construction And Commissioning Of Bore Hole By Dth/Rotary/ Combination Rig Of 200 Mm Dia, Supply And Installation Of Energy Efficient Submersible Pump Sets, Panels, Cables And Other Allied Works Including Commissioning And Testing Of Tube Well Under Jurisdiction Of City Circle Ajmer With 02 Year Defect Liability Including 5 Years Operation And Maintenance
BOQ
| Sl. No. | Item Description |
| 1 | Construction of tube well from ground level & up to 100 mtr depth to accommodate housing and assembly pipe of following sizes in all type of alluvium strata unconsolidated formation such as pebbles, boulders etc. by percussion/rotary drilling method as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications, with gravel as per IS:4097-1967 and it's packing as per IS: 2800 (Part I & II) 1979 as amended up to date (the work includes the cost of gravel & it's primary packing and packing during development, lowering of housing & strainer assembly pipes with supply and wrapping of coir-rope, wherever necessary for arresting fine sand particles and development work, but excluding the cost of housing and strainer pipe assembly). The work would be completed after obtaining sand free water.Rates are exclusive of GST. |
| 2 | Nominal bore 150 mm dia. |
| 3 | Nominal bore 200 mm dia. |
| 4 | Add 15% extra on above item for drilling depth beyond 100 mtr, If depth of bore is more than 100 mtr. (150 mm dia) |
| 5 | Add 15% extra on above item for drilling depth beyond 100 mtr, If depth of bore is more than 100 mtr. (200 mm dia) |
| 6 | Construction of Tube Well from ground level and up to 100 mtr. depth to accommodate housing and assembly pipe in all type of alluvium strata, unconsolidated formation such as pebbles, boulders etc. by percussion/ rotary drilling method as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications for removal of overburden. The work includes the cost of lowering of casing pipe, but excludes the cost of casing pipe. Rates are exclusive of GST. |
| 7 | Nominal bore 200 mm dia. |
| 8 | Add 15% extra on above item (Item No 6) for drilling depth beyond 100 mtr, rate shall be applicable for only extra depth beyond 100 mtr . |
| 9 | Construction of tube well after completion of drilling by rotary /percussion method & up to 100 mtr. depth in all type of rocks by DTH system as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work shall be deemed completed only after obtaining sand free water. The bore well should have a throughout nominal size bore beyond casing pipe. Rates are exclusive of GST. |
| 10 | Nominal bore 150 mm dia. |
| 11 | Nominal bore 200 mm dia. |
| 12 | Add 15% extra on above item for drilling depth beyond 100 mtr, If depth of bore is more than 100 mtr. 150 mm dia. |
| 13 | Add 15% extra on above item for drilling depth beyond 100 mtr, If depth of bore is more than 100 mtr. 200 mm dia. |
| 14 | Construction of Tube Well up to 100 mtr. depth in all type of rocks by DTH system & over burden to accommodate casing pipe of following sizes in all types of soils & over burden including lowering of casing pipes, (if required) excluding cost of casing pipes, as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work would be completed after obtaining sand free water. The tube well should have a through out bore as per nominal dia of casing pipe.Rates are exclusive of GST. |
| 15 | Nominal bore 150 mm dia. |
| 16 | Nominal bore 200 mm dia. |
| 17 | Add 15% extra on above item for drilling depth beyond 100 mtr, If depth of bore is more than 100 mtr. 150 mm dia. |
| 18 | Add 15% extra on above item for drilling depth beyond 100 mtr, If depth of bore is more than 100 mtr. 200 mm dia. |
| 19 | Construction of tube well from ground level and up to 100 mtr. depth and above of following sizes in all types of soils in alluvium strata, unconsolidated formation such as pebbles, boulders etc. by \\"bailing\\" method and without gravel packing as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work includes formation of cavity at bottom by development with appropriate air compressor or bailer pumping and also lowering of casing pipe but excluding cost of the casing pipe. The tube well should have a throughout bore as per nominal dia of casing pipe. The work would be completed after obtaining sand free water.Rates are exclusive of GST. |
| 20 | Nominal bore 125 mm dia. |
| 21 | Nominal bore 150 mm dia. |
| 22 | Nominal bore 200 mm dia. |
| 23 | Construction of tube well from ground level and up to 100 mtr depth and above to accommodate housing assembly pipe in all type of unconsolidated formation such as pebbles, boulders, collapsible formation etc. by Odex drilling method as per IS: IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work will include lowering of housing and strainer pipe assembly and casing shoe including cost of casing shoe, but excluding cost of the casing pipe. The work would be completed after obtaining sand free water. Rates are exclusive of GST. |
| 24 | Nominal bore 125 mm dia. |
| 25 | Nominal Bore 150 mm dia. |
| 26 | Nominal bore 200 mm dia. |
| 27 | Add 15% extra on above item for drilling depth beyond 100 mtr, If depth of bore is more than 100 mtr.125 mm dia. |
| 28 | Add 15% extra on above item for drilling depth beyond 100 mtr, If depth of bore is more than 100 mtr. 150 mm dia. |
| 29 | Add 15% extra on above item for drilling depth beyond 100 mtr, If depth of bore is more than 100 mtr.200 mm dia. |
| 30 | Deepening of existing tube well by DTH system beyond existing depth up to 100 mtr. and above in all type of rocks including flushing of tube well and obtaining sand free water. Rates are exclusive of GST. |
| 31 | Nominal bore 150 mm dia. |
| 32 | Nominal bore 200 mm dia. |
| 33 | Testing verticality of tube well by plumbing system and yield test and draw down test by pumping system as per IS : 2800 (Part – II) – 1979 or as per amended up to date.Rate is exclusive of GST. |
| 34 | Supplying & Packing P-gravel suitable for slot size/mesh size as suggested in IS 2800 (Part-1) 1991 or as per amended up to date.Rate is exclusive of GST. |
| 35 | Development of tube well having depth up to 250 mtr as per IS: 11189- 1985 and IS: 2800 (Part- I)- 1991 (both amended up to date) using suitable methods to give sand free water for required yield of the gravel packed tube well.Rate is exclusive of GST. |
| 36 | Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to date of following sizes Rates are exclusive of GST. |
| 37 | 150 mm dia NB(Thickness of pipe 5.0 mm & mass of tube 20.13 Kg/m) |
| 38 | 200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m) |
| 39 | Labour charges for making slots on blank pipes made of ERW MS black pipe ISI marked of following sizes, the slotting should be as per IS:8110-1985. Rates are exclusive of GST. |
| 40 | 125 mm dia nominal bore of 4.8 mm thickness |
| 41 | 150 mm dia nominal bore of 4.8 mm thickness |
| 42 | 200 mm dia nominal bore of 5.4mm thickness |
| 43 | Providing & laying ISI marked GI Pipe Light duty ( “A” class) as per IS: 1239 for casing pipe for submersible cable external work 40 mm dia complete in all respect.Rate is exclusive of GST. |
| 44 | Supply & Installation of single phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.Rates are exclusive of GST. |
| 45 | Up to 2.0 KW |
| 46 | Above 2.0 KW |
| 47 | Supply & Installation of 3 phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.Rates are exclusive of GST. |
| 48 | Up to 5.5 KW (7.5 HP) & head up to 120 mtr. |
| 49 | Up to 5.5 KW (7.5 HP) & head above 120 mtr. |
| 50 | 7.5 KW (10 HP) & head up to 120 mtr. |
| 51 | 7.5 KW (10 HP) & head above 120 mtr. |
| 52 | 9.3 KW (12.5 HP) & head up to 120 mtr. |
| 53 | 9.3 KW (12.5 HP) & head above 120 mtr. |
| 54 | 11 KW (15 HP) & head up to 120 mtr. |
| 55 | 11 KW (15 HP) & head above 120 mtr. |
| 56 | 13 KW (17.5 HP) & head up to 120 mtr. |
| 57 | 13 KW (17.5 HP) & head above 120 mtr. |
| 58 | 15 KW (20 HP) and above, head up to 120 mtr. |
| 59 | 15 KW (20 HP) and above, head above 120 mtr. |
| 60 | Supply and Fixing of Electric feeder panel (having projected canopy)for submersible pump set Single phase up to 5 HP, comprising of DOL Starter, MCB, Indicating Light, Ammeter, Volt meter, connection plate, condensers of approved make and the panel enclosure should be made out from 18 gauge M.S. Sheet with powder coating. Panel size Height 600 mm Width 500 mm depth 250 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete platform. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The operation of panel should be suitable for on 240 Volt AC Supply.Rate is exclusive of GST. |
| 61 | Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB, DOL starter, overload relay, ampere meter, volt meter, phase preventer, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 300mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete platform. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.Rate is exclusive of GST. |
| 62 | Up to 5.00 HP |
| 63 | Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.Rates are exclusive of GST. |
| 64 | Above 5 HP and up to 10 HP |
| 65 | Above 10 HP and up to 15 HP |
| 66 | Above 15 HP and up to 20 HP |
| 67 | Above 20 HP and up to 30 HP |
| 68 | Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc. Rates are exclusive of GST. |
| 69 | 3 core 4.0 Sq.mm |
| 70 | 3 core 6.0 Sq.mm |
| 71 | 3 core 10.0 Sq.mm |
| 72 | 3 core 16.0 Sq.mm |
| 73 | Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. Rates are exclusive of GST. |
| 74 | 10.0 Sq.mm, 4 core |
| 75 | 16.0 Sq.mm, 4 core |
| 76 | 25.0 Sq.mm, 3.5 core |
| 77 | 35.0 Sq.mm, 3.5 core |
| 78 | Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. Rate is exclusive of GST. |
| 79 | Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set.Rate is exclusive of GST. |
| 80 | Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2\\" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug.Rates are exclusive of GST. |
| 81 | 125 mm dia |
| 82 | 150 mm dia |
| 83 | 200 mm dia |
| 84 | Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B\\" class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.Rates are exclusive of GST. |
| 85 | 32 mm dia |
| 86 | 50 mm dia |
| 87 | Providing & Lowering in tube well ISI marked HDPE pipe as per IS 4984:1995 or amended up to date in PE 80 grade and class PN 10 of following dia. including HDPE/GI fittings and PVC rope confirming to IS 5175:1992 or amended up to date, along with clamping of submersible cable etc. complete in all respect.Rates are exclusive of GST. |
| 88 | 40 mm dia |
| 89 | 50 mm dia |
| 90 | 63 mm dia |
| 91 | 75 mm dia |
| 92 | 90 mm dia |
| 93 | Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended up to date of approved make including cost of all material and labour as per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of following dia.Rates are exclusive of GST. |
| 94 | 50 mm dia |
| 95 | 65 mm dia |
| 96 | 80 mm dia |
| 97 | Providing & Fixing pump safety cage as per specifications or as directed by Engineer in charge.Rate is exclusive of GST. |
| 98 | Providing and Fixing of ISI marked PVC storage tank of following capacity as per IS: 12701-1989 (of approved make) with cover, 25 mm dia. 1 mtr long GI overflow pipe, 25 cm long 25 mm dia washout GI pipe with plug & socket, including P&F 32 mm dia Ball Cock (Float valve) IS 1703 marked with rod and PVC ball complete with brass weight 1000 gm, including P&F 15mm dia CI quarter turn heavy duty Bib Cocks four no's of superior quality and approved make, including interconnections complete job.Rates are exclusive of GST. |
| 99 | 1000 litres capacity |
| 100 | 2000 litres capacity |
| 101 | Fabrication & Fixing M.S. Stand of specified class of angle iron L-shaped of 50 mm size with four legs grouted by 300*300*300 mm CC Block M-15 in the ground and all legs tied up with each other through same size of angle iron along with cross bars to support the bottom of 1000 Ltr./ 2000 Ltr. PVC tank complete in all respect.Rate is exclusive of GST. |
| 102 | Providing & Fixing of double flanged, CI body, ISI marked NRV of approved make of following sizesRates are exclusive of GST. |
| 103 | 65 mm dia |
| 104 | 80 mm dia |
| 105 | Proving and Fixing 32 mm dia Full way valve or wheel valve as per IS:778 or amended up to date of approved make, on pump delivery pipe.Rate is exclusive of GST. |
| 106 | Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg. including all jointing material as per specification with safety cover.Rate is exclusive of GST. |
| 107 | Construction of bore hole for shallow depth tube well from ground level to required depth for following size for all type of relevant strata by percussion/ rotary drilling/ hand boring method excluding cost of casing pipe. The bore hole should be as per nominal bore of PVC casing pipe. The work will be complete after obtaining sand free water. Rates are exclusive of GST. |
| 108 | 125 mm dia nominal bore |
| 109 | 150 mm dia nominal bore |
| 110 | 200 mm dia nominal bore |
| 111 | Providing and Lowering of ISI mark PVC-U casing and screen pipe as per IS : 12818 : 2010 or amended up to date having pipe thickness as per IS code suitable for TW and DCB with threading , winding with superior quality of plastic mesh & rope in three layers with end cap complete as per technical specification and direction of Engineer In charge.Rates are exclusive of GST. |
| 112 | Shallow well casing pipe (CS) suitable for depth up to 80 mtr. |
| 113 | 150 mm nominal dia ( internal dia ). |
| 114 | 200 mm nominal dia ( internal dia ). |
| 115 | Medium well casing pipe (CM) suitable for depth above 80 mtr and up to 250mtr. |
| 116 | 125 mm nominal dia ( internal dia ) |
| 117 | 150 mm nominal dia ( internal dia ) |
| 118 | 200 mm nominal dia ( internal dia ) |
| 119 | Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended up to date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method , including transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) . Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M.Rates are exclusive of GST. |
| 120 | HDPE PE-80 PN-6 |
| 121 | 90 mm dia |
| 122 | 110 mm dia |
| 123 | HDPE PE-100 PN-6 |
| 124 | 90 mm dia |
| 125 | 110 mm dia |
| 126 | HDPE PE-80 PN-10 |
| 127 | 90 mm dia |
| 128 | 110 mm dia |
| 129 | HDPE PE-100 PN-10 |
| 130 | 90 mm dia |
| 131 | 110 mm dia |
| 132 | Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge.Rates are exclusive of GST. |
| 133 | MS pipe specials up to 600mm dia (with minimum 5mm thickness sheet) |
| 134 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.:All kinds of soilRate is exclusive of GST. |
| 135 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and stacking serviceable material for measurements and disposal of unserviceable material as directed, with in a lead of 50 Mtr. including all safety provisions required .:Rates are exclusive of GST. |
| 136 | Ordinary rock |
| 137 | Hard rock (requiring blasting) |
| 138 | Hard rock(blasting prohibited) |
| 139 | Dismantling of flexible pavement for pipe line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work.Rates are exclusive of GST. |
| 140 | Bituminous courses |
| 141 | Granular courses |
| 142 | Dismantling of cement concrete pavement for pipe line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work.Rate is exclusive of GST. |
| 143 | Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves straight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - AISI- 410 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel Insertion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 144 | Manually Operated CI Sluice valve of Class PN-1.0 |
| 145 | 80 mm HW |
| 146 | 100 mm HW |
| 147 | Work of Inter Connection in CI/DI/MS pipe line up to 1.5 mtr depth by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site, cutting of existing pipeline, jointing of Tee (complete) and other specials to make inter connection repair leak proof and then refill the pit from excavated sand by ramming it at sides of pipe & upto ground level for entire job contractor will use his own T&P & labour and will arrange transportation of material required from store. (Material such as Tee/ Tee Clamp/rubber sheet/ CID joints required for inter connection shall be provided by the department free of cost).Rate is exclusive of GST. |
| 148 | In all type Soil |
| 149 | 80 mm to 100 mm |
| 150 | 125 mm to 150 mm |
| 151 | 200 mm to 300 mm |
| 152 | Add on above item no.17 for B.T. Road 5% Each |
| 153 | Add on above item no.17 for CC Road 10% Each |
| 154 | Add on above item no.17 if depth of pipe line is above 1.5 mtr and up to 3.0 mtr 20% Each |
| 155 | P & F Gun-metal Non-return Valve or Check Valve (IS : 778 Make) of approved make, superior quality:(PWD Building BSR 2026) Exclusive of GST |
| 156 | 40mm nominal bore. |
| 157 | Horizontal |
| 158 | 50mm nominal bore. |
| 159 | Horizontal |
| 160 | Maintenance of tubewells which includes round the clock monitoring of tubewells of all sizes, complete repairs / rewinding of submersible pump sets including cost of material components required to repair pumpsets, starters, meters etc. of electric panel of tube wells, Lowering and unlowering of pumpsets complete in all respect, maintenance of log-books & Histroy sheet as directed by Engineer-in-charge for tubewell per month.Rate is exclusive of GST. |
| 161 | 0.5 HP to 5.0 HP |
| 162 | 6.0 HP to 7.5 HP |
| 163 | 8.0 HP to 10.0 HP |
| 164 | 11.0 HP to 12.5 HP |
| 165 | 13.0 HP to 15.0 HP |
| 166 | Daily/ periodical operation of valves at supply times for specified by department per sluice valve per month. (Valve rod and cap to be arranged by contractor)Rate is exclusive of GST. |
| 167 | 80-300mm |
| 168 | SITC of Digital Type Single Phase DOL Starter Electrical Control Feeder Panel, 63A, suitable for operation of Single-phase pump set on 215V AC supply, comprising input MCB (DP 63A.), GFU with auxiliary contact for earth fault protection, AC-3 duty PMC based DC contactors 50 Amp. 1P (DOL type), Microprocessor basedDigital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal, connectors, complete internal wiring with copper conductors (for control and power), capacitor bank and all necessary hardware.The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, Complete with all standard protections, indications and automation features required for safe, efficient and reliable operation of pump sets under varying field conditions, complete in all respects as per specification and direction of Engineer-in-Charge. Rate is exclusive of GST. |
| 169 | Upto 5 HP (Single Phase) |
| 170 | SITC of Digital Type DOL Starter Electrical Control Feeder Panel, 40A, suitable for operation of 3-phase pump set on 415V AC supply, comprising input MCB (40Amp. FP), GFU with auxiliary contact for earth fault protection, 32Amp. AC-3 duty PMC based DC contactors (for DOL and APSC type),Microprocessorbased Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications,Heavy Duty terminal, connectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 3 kVAR, and all necessary hardware.The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, Complete with all standard protections, indications and automation features required for safe, efficient and reliable operation of pump sets under varying field conditions, complete in all respects as per specification and direction of Engineer In Charge. Rate is exclusive of GST. |
| 171 | Up to 5 HP (DOL type) |
| 172 | SITC of Digital Type Star Delta Starter Electrical Control Feeder Panel, 100A, suitable for operation of 3-phase pump set on 415V AC supply, comprising input 100Amp. MCCB (TP), GFU with auxiliary contact for earth fault protection, 32Amp. AC-3 duty PMC based DC contactors (For Star and Main), 40Amp. 1 Pole Contactor for APSC, 22Amp. Contactor for Delta,Microprocessor based Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal connectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 3 kVAR, and all necessary hardware.The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, Complete with all standard protections, indications and automation features required for safe, efficient and reliable operation of pump sets under varying field conditions, complete in all respects as per specification and direction of Engineer-in-Charge. Rate is exclusive of GST. |
| 173 | Above 5 HP and up to 10 HP (Star Delta type) |
| 174 | SITC of Digital Type Star Delta Starter Electrical Control Feeder Panel, 100A, suitable for operation of 3-phase pump set on 415V AC supply, comprising input 100Amp. MCCB (TP), GFU with auxiliary contact for earth fault protection, 35Amp. AC-3 duty PMC based DC contactors (For Star and Main), 45Amp. 1 Pole Contactor for APSC, 25Amp. Contactor for Delta,Microprocessor based Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal connectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 5 kVAR, and all necessary hardware.The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, Complete with all standard protections, indications and automation features required for safe, efficient and reliable operation of pump sets under varying field conditions, complete in all respects as per specification and direction of Engineer-in-Charge. Rate is exclusive of GST. |
| 175 | Above 10 HP and up to 15 HP (Star Delta type) |
| 176 | SITC of Digital Type Star Delta Starter Electrical Control Feeder Panel, 100A, suitable for operation of 3-phase pump set on 415V AC supply, comprising input 100Amp. MCCB (TP), GFU with auxiliary contact for earth fault protection, 40Amp. AC-3 duty PMC based DC contactors (For Star and Main), 45Amp. 1 Pole Contactor for APSC, 32Amp. Contactor for Delta,Microprocessor based Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal connectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 7 kVAR, and all necessary hardware.The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, Complete with all standard protections, indications and automation features required for safe, efficient and reliable operation of pump sets under varying field conditions, complete in all respects as per specification and direction of Engineer-in-Charge. Rate is exclusive of GST. |
| 177 | Above 15 HP and up to 20 HP (Star Delta type) |
| 178 | SITC of Digital Type Star Delta Starter Electrical Control Feeder Panel, 125A, suitable for operation of 3-phase pump set on 415V AC supply, comprising input 125Amp. MCCB (TP), GFU with auxiliary contact for earth fault protection, 45 Amp. AC-3 duty PMC based DC contactors (For Star and Main), 50 Amp. 1 Pole Contactor for APSC, 40 Amp. Contactor for Delta,Microprocessor based Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal connectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 8.3 kVAR, and all necessary hardware.The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, Complete with all standard protections, indications and automation features required for safe, efficient and reliable operation of pump sets under varying field conditions, complete in all respects as per specification and direction of Engineer-in-Charge. Rate is exclusive of GST. |
| 179 | Above 20 HP and up to 25 HP (Star Delta type) |
| 180 | SITC of Digital Type Star Delta Starter Electrical Control Feeder Panel, 125A, suitable for operation of 3-phase pump set on 415V AC supply, comprising input 125Amp. MCCB (TP), GFU with auxiliary contact for earth fault protection, 63 Amp. AC-3 duty PMC based DC contactors (For Star and Main), 80 Amp. 1 Pole Contactor for APSC, 50 Amp. Contactor for Delta,Microprocessor based Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal connectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 12.5 kVAR, and all necessary hardware.The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, Complete with all standard protections, indications and automation features required for safe, efficient and reliable operation of pump sets under varying field conditions, complete in all respects as per specification and direction of Engineer-in-Charge. Rate is exclusive of GST. |
| 181 | Above 20 HP and up to 30 HP (Star Delta type) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender