Tender For Purchase Of Equipment , Spectrofluorometer , • Optical System And Monochromator: Optical Design: Single/Double Monochromator Using Holographic Concave Grating - Excitation & Emission Range: Zero Order, 200 Nm To 750 Nm (Or) Better - Wavelength
Tender Overview
Project Description
Tender For Purchase Of Equipment , Spectrofluorometer , • Optical System And Monochromator: Optical Design: Single/Double Monochromator Using Holographic Concave Grating - Excitation & Emission Range: Zero Order, 200 Nm To 750 Nm (Or) Better - Wavelength Accuracy: Should Be At Least +/-1.5 Nm (Or) Better - Wavelength Repeatability: +/- 1.0 Nm (Or) Better - Spectral Bandwidth (Slits): Variable And Minimum Should Be 1, 2.5, 5,10,20, L5, L10Nm On Both Excitation And Emission Monochromators - High-Order Diffraction Removal: Automatic Software-Controlled Higher-Order Diffraction Cut Filters Must Be Provided As Standard On Both Channels. • Light Source And Detection Light Source: High-Stability, Long-Life 150 W Ozone-Free Xenon Annual Rate Contract Lamp With Shielded Lamp Housing (Rated Lifetime ≥ 3,000 Hours).- Validation Standard: Built-In / Integrated Mercury (Hg) Lamp For Automatic Wavelength Calibration And Instrument Validation.- Photofading Protection: Automatic Software-Controlled Shutter System To Protect Sensitive Biological Or Chemical Samples From Photobleaching During Idle Periods. - Detectors; Excitation Channel: Silicon Photodiode For Real-Time Reference Monitoring. Emission Channel: High-Performance, High-Sensitivity Photomultiplier Tube (Pmt). Sensitivity (Signal-To-Noise): Water Raman Peak S/N Ratio ≥ 8,000 : 1(Rms) • Performance & Measurement Capabilities -Wavelength Scan Speed: 10 To 20,000 Nm/Min (Or Better). - Slew Speed: 30,000 Nm/Min Or Better. - Photometric Range: -10,000 To +10,000 Or Wide Dynamic Range (≥6 Orders Of Magnitude). Software Package: Windows 10/11-Compatible Control & Processing Software Supporting: 2D & 3D Excitation-Emission Matrix (Eem) Scanning, Fixed Wavelength & Multi-Wavelength Kinetics / Time-Course Decay, Synchronous Scan Mode (Constant Wavelength And Constant Energy), Relative Quantum Yield Calculation, Absorbance Measurement & Automatic Spectral Correction, Instrument Self-Diagnostics And Auto-Accessory Recognition • Sample Compartment & Accessories - Liquid Sample Handling: Standard 10 Mm Rectangular Cell Holder Assembly. Must Include 1 Pair (2 Nos.) Of Quartz Fluorescence Cuvettes (10 Mm Path Length, 3.5 Ml Volume, 4-Sided Polished Windows) With Ptfe Stoppers/Lids. Solid/Powder Sample Handling: Dedicated Solid/Powder Sample Holder For Thin Films, Powders, And Opaque Substrates. Temperature Control: Provision/Capability To Integrate A Peltier-Based Thermostatted Cell Holder System. Expansion Options: System Must Support Future Upgradeability To Micro-Volume Cell Holders (Up To 5Μl). • Warranty & Delivery Terms: Warranty: Minimum 3-Year Comprehensive Warranty On The Complete System Including Light Source And Accessories From The Date Of Successful Installation. Installation & Training: Free On-Site Installation, Demonstration, And User Training By Factory-Trained Service Engineers.
BOQ
| Sl. No. | Item Description |
| 1 | SPECTROFLUOROMETER |
| 2 | • Optical System and Monochromator: Optical Design: Single/Double Monochromator using Holographic concave grating - Excitation & Emission Range: Zero Order, 200 nm to 750 nm (or) better - Wavelength Accuracy: Should be at least +/-1.5 nm (or) Better - Wavelength Repeatability: +/- 1.0 nm (or) Better - Spectral Bandwidth (Slits): Variable and minimum should be 1, 2.5, 5,10,20, L5, L10nm on Both excitation and emission monochromators - High-Order Diffraction Removal: Automatic software-controlled higher-order diffraction cut filters must be provided as standard on both channels.• Light Source and Detection Light Source: High-stability, long-life 150 W Ozone-Free Xenon Arc Lamp with shielded lamp housing (rated lifetime ≥ 3,000 hours).- Validation Standard: Built-in / integrated Mercury (Hg) lamp for automatic wavelength calibration and instrument validation.- Photofading Protection: Automatic software-controlled shutter system to protect sensitive biological or chemical samples from photobleaching during idle periods. – Detectors; Excitation Channel: Silicon Photodiode for real-time reference monitoring. Emission Channel: High-performance, high-sensitivity Photomultiplier Tube (PMT). Sensitivity (Signal-to-Noise): Water Raman Peak S/N ratio ≥ 8,000 : 1(RMS)• Performance & Measurement Capabilities -Wavelength Scan Speed: 10 to 20,000 nm/min (or better). - Slew Speed: 30,000 nm/min or better. - Photometric Range: -10,000 to +10,000 or wide dynamic range (≥6 orders of magnitude). Software Package: Windows 10/11-compatible control & processing software supporting: 2D & 3D Excitation-Emission Matrix (EEM) scanning, Fixed wavelength & multi-wavelength kinetics / time-course decay, Synchronous scan mode (constant wavelength and constant energy), Relative Quantum Yield calculation, Absorbance measurement & automatic spectral correction, Instrument self-diagnostics and auto-accessory recognition • Sample Compartment & Accessories - Liquid Sample Handling: Standard 10 mm rectangular cell holder assembly. Must include 1 pair (2 Nos.) of Quartz Fluorescence Cuvettes (10 mm path length, 3.5 mL volume, 4-sided polished windows) with PTFE stoppers/lids. Solid/Powder Sample Handling: Dedicated Solid/Powder Sample Holder for thin films, powders, and opaque substrates. Temperature Control: Provision/capability to integrate a Peltier-based thermostatted cell holder system. Expansion Options: System must support future upgradeability to Micro-volume cell holders (up to 5µL). • Warranty & Delivery Terms: Warranty: Minimum 3-Year comprehensive warranty on the complete system including light source and accessories from the date of successful installation. Installation & Training: Free on-site installation, demonstration, and user training by factory-trained service engineers. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender