Educational and Research Institute Local Bodies Closing in 9 days TDR #57081522

Tender For Purchase Of Equipment , Spectrofluorometer , • Optical System And Monochromator: Optical Design: Single/Double Monochromator Using Holographic Concave Grating - Excitation & Emission Range: Zero Order, 200 Nm To 750 Nm (Or) Better - Wavelength

Issued by Local Bodies · Coimbatore, Tamil Nadu
Tender Value
Ref. Documents
Estimated cost
Bid Submission
02 Sep 2026
9 days left
EMD
24000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Coimbatore → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Purchase Of Equipment , Spectrofluorometer , • Optical System And Monochromator: Optical Design: Single/Double Monochromator Using Holographic Concave Grating - Excitation & Emission Range: Zero Order, 200 Nm To 750 Nm (Or) Better - Wavelength Accuracy: Should Be At Least +/-1.5 Nm (Or) Better - Wavelength Repeatability: +/- 1.0 Nm (Or) Better - Spectral Bandwidth (Slits): Variable And Minimum Should Be 1, 2.5, 5,10,20, L5, L10Nm On Both Excitation And Emission Monochromators - High-Order Diffraction Removal: Automatic Software-Controlled Higher-Order Diffraction Cut Filters Must Be Provided As Standard On Both Channels. • Light Source And Detection Light Source: High-Stability, Long-Life 150 W Ozone-Free Xenon Annual Rate Contract Lamp With Shielded Lamp Housing (Rated Lifetime ≥ 3,000 Hours).- Validation Standard: Built-In / Integrated Mercury (Hg) Lamp For Automatic Wavelength Calibration And Instrument Validation.- Photofading Protection: Automatic Software-Controlled Shutter System To Protect Sensitive Biological Or Chemical Samples From Photobleaching During Idle Periods. - Detectors; Excitation Channel: Silicon Photodiode For Real-Time Reference Monitoring. Emission Channel: High-Performance, High-Sensitivity Photomultiplier Tube (Pmt). Sensitivity (Signal-To-Noise): Water Raman Peak S/N Ratio ≥ 8,000 : 1(Rms) • Performance & Measurement Capabilities -Wavelength Scan Speed: 10 To 20,000 Nm/Min (Or Better). - Slew Speed: 30,000 Nm/Min Or Better. - Photometric Range: -10,000 To +10,000 Or Wide Dynamic Range (≥6 Orders Of Magnitude). Software Package: Windows 10/11-Compatible Control & Processing Software Supporting: 2D & 3D Excitation-Emission Matrix (Eem) Scanning, Fixed Wavelength & Multi-Wavelength Kinetics / Time-Course Decay, Synchronous Scan Mode (Constant Wavelength And Constant Energy), Relative Quantum Yield Calculation, Absorbance Measurement & Automatic Spectral Correction, Instrument Self-Diagnostics And Auto-Accessory Recognition • Sample Compartment & Accessories - Liquid Sample Handling: Standard 10 Mm Rectangular Cell Holder Assembly. Must Include 1 Pair (2 Nos.) Of Quartz Fluorescence Cuvettes (10 Mm Path Length, 3.5 Ml Volume, 4-Sided Polished Windows) With Ptfe Stoppers/Lids. Solid/Powder Sample Handling: Dedicated Solid/Powder Sample Holder For Thin Films, Powders, And Opaque Substrates. Temperature Control: Provision/Capability To Integrate A Peltier-Based Thermostatted Cell Holder System. Expansion Options: System Must Support Future Upgradeability To Micro-Volume Cell Holders (Up To 5Μl). • Warranty & Delivery Terms: Warranty: Minimum 3-Year Comprehensive Warranty On The Complete System Including Light Source And Accessories From The Date Of Successful Installation. Installation & Training: Free On-Site Installation, Demonstration, And User Training By Factory-Trained Service Engineers.

BOQ

Name of Work:- Purchase of Equipment
Sl. No. Item Description
1SPECTROFLUOROMETER
2• Optical System and Monochromator: Optical Design: Single/Double Monochromator using Holographic concave grating - Excitation & Emission Range: Zero Order, 200 nm to 750 nm (or) better - Wavelength Accuracy: Should be at least +/-1.5 nm (or) Better - Wavelength Repeatability: +/- 1.0 nm (or) Better - Spectral Bandwidth (Slits): Variable and minimum should be 1, 2.5, 5,10,20, L5, L10nm on Both excitation and emission monochromators - High-Order Diffraction Removal: Automatic software-controlled higher-order diffraction cut filters must be provided as standard on both channels.• Light Source and Detection Light Source: High-stability, long-life 150 W Ozone-Free Xenon Arc Lamp with shielded lamp housing (rated lifetime ≥ 3,000 hours).- Validation Standard: Built-in / integrated Mercury (Hg) lamp for automatic wavelength calibration and instrument validation.- Photofading Protection: Automatic software-controlled shutter system to protect sensitive biological or chemical samples from photobleaching during idle periods. – Detectors; Excitation Channel: Silicon Photodiode for real-time reference monitoring. Emission Channel: High-performance, high-sensitivity Photomultiplier Tube (PMT). Sensitivity (Signal-to-Noise): Water Raman Peak S/N ratio ≥ 8,000 : 1(RMS)• Performance & Measurement Capabilities -Wavelength Scan Speed: 10 to 20,000 nm/min (or better). - Slew Speed: 30,000 nm/min or better. - Photometric Range: -10,000 to +10,000 or wide dynamic range (≥6 orders of magnitude). Software Package: Windows 10/11-compatible control & processing software supporting: 2D & 3D Excitation-Emission Matrix (EEM) scanning, Fixed wavelength & multi-wavelength kinetics / time-course decay, Synchronous scan mode (constant wavelength and constant energy), Relative Quantum Yield calculation, Absorbance measurement & automatic spectral correction, Instrument self-diagnostics and auto-accessory recognition • Sample Compartment & Accessories - Liquid Sample Handling: Standard 10 mm rectangular cell holder assembly. Must include 1 pair (2 Nos.) of Quartz Fluorescence Cuvettes (10 mm path length, 3.5 mL volume, 4-sided polished windows) with PTFE stoppers/lids. Solid/Powder Sample Handling: Dedicated Solid/Powder Sample Holder for thin films, powders, and opaque substrates. Temperature Control: Provision/capability to integrate a Peltier-based thermostatted cell holder system. Expansion Options: System must support future upgradeability to Micro-volume cell holders (up to 5µL). • Warranty & Delivery Terms: Warranty: Minimum 3-Year comprehensive warranty on the complete system including light source and accessories from the date of successful installation. Installation & Training: Free on-site installation, demonstration, and user training by factory-trained service engineers. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57081522
AUTHORITY Local Bodies
TENDER VALUE Ref. Documents
LAST DATE 02-09-2026
Authority
Authority Name Department Of Higher Education
Work Description Tender For Purchase Of Equipment , Spectrofluorometer , • Optical System And Monochromator: Optical Design: Single/Double Monochromator Using Holographic Concave Grating - Excitation & Emission Range: Zero Order, 200 Nm To 750 Nm (Or) Better - Wavelength Accuracy: Should Be At Least +/-1.5 Nm (Or) Better - Wavelength Repeatability: +/- 1.0 Nm (Or) Better - Spectral Bandwidth (Slits): Variable And Minimum Should Be 1, 2.5, 5,10,20, L5, L10Nm On Both Excitation And Emission Monochromators - High-Order Diffraction Removal: Automatic Software-Controlled Higher-Order Diffraction Cut Filters Must Be Provided As Standard On Both Channels. • Light Source And Detection Light Source: High-Stability, Long-Life 150 W Ozone-Free Xenon Annual Rate Contract Lamp With Shielded Lamp Housing (Rated Lifetime ≥ 3,000 Hours).- Validation Standard: Built-In / Integrated Mercury (Hg) Lamp For Automatic Wavelength Calibration And Instrument Validation.- Photofading Protection: Automatic Software-Controlled Shutter System To Protect Sensitive Biological Or Chemical Samples From Photobleaching During Idle Periods. - Detectors; Excitation Channel: Silicon Photodiode For Real-Time Reference Monitoring. Emission Channel: High-Performance, High-Sensitivity Photomultiplier Tube (Pmt). Sensitivity (Signal-To-Noise): Water Raman Peak S/N Ratio ≥ 8,000 : 1(Rms) • Performance & Measurement Capabilities -Wavelength Scan Speed: 10 To 20,000 Nm/Min (Or Better). - Slew Speed: 30,000 Nm/Min Or Better. - Photometric Range: -10,000 To +10,000 Or Wide Dynamic Range (≥6 Orders Of Magnitude). Software Package: Windows 10/11-Compatible Control & Processing Software Supporting: 2D & 3D Excitation-Emission Matrix (Eem) Scanning, Fixed Wavelength & Multi-Wavelength Kinetics / Time-Course Decay, Synchronous Scan Mode (Constant Wavelength And Constant Energy), Relative Quantum Yield Calculation, Absorbance Measurement & Automatic Spectral Correction, Instrument Self-Diagnostics And Auto-Accessory Recognition • Sample Compartment & Accessories - Liquid Sample Handling: Standard 10 Mm Rectangular Cell Holder Assembly. Must Include 1 Pair (2 Nos.) Of Quartz Fluorescence Cuvettes (10 Mm Path Length, 3.5 Ml Volume, 4-Sided Polished Windows) With Ptfe Stoppers/Lids. Solid/Powder Sample Handling: Dedicated Solid/Powder Sample Holder For Thin Films, Powders, And Opaque Substrates. Temperature Control: Provision/Capability To Integrate A Peltier-Based Thermostatted Cell Holder System. Expansion Options: System Must Support Future Upgradeability To Micro-Volume Cell Holders (Up To 5Μl). • Warranty & Delivery Terms: Warranty: Minimum 3-Year Comprehensive Warranty On The Complete System Including Light Source And Accessories From The Date Of Successful Installation. Installation & Training: Free On-Site Installation, Demonstration, And User Training By Factory-Trained Service Engineers.
Basic Detail
Tender No C7/CRTD/Physics/CMRG/2421
Bidding Type Tender
Location
City Coimbatore
State Tamil Nadu
Key Dates
Publish Date 18 Aug 2026
Submission Date 02 Sep 2026
Open Date 03 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 24000
Exemption Available
Document List
7bdf5f65-90aa-4fe5-84b8-ca02ac575b0d.html
BOQ_836200.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Sep 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

7bdf5f65-90aa-4fe5-84b8-ca02ac575b0d.html

xls

BOQ_836200.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders