Defence Statutory Bodies & Commissions/Committees Closing in 17 days TDR #57081140

Tender For Certain Repairs To Fencing, Gate,Cgi Sheets, Culverts Drain, Reinforced Cement Concrete Cover, And Hardstanding In Area Under Age B/R-Ii At Af Stn Ad Ur

Issued by Statutory Bodies & Commissions/Committees · Jalandhar, Punjab
Tender Value
45 Lakhs
Estimated cost
Bid Submission
10 Sep 2026
17 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jalandhar → Punjab
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Certain Repairs To Fencing, Gate,Cgi Sheets, Culverts Drain, Reinforced Cement Concrete Cover, And Hardstanding In Area Under Age B/R-Ii At Af Stn Ad Ur

BOQ

Name of Work:- CERTAIN REPAIRS TO FENCING, GATE,CGI SHEETS, CULVERTS DRAIN, RCC COVER, AND HARDSTANDING IN AREA UNDER AGE B/R-II AT AF STN AD UR
Sl. No. Item Description
1Excavation in trenches not exc 1.5 m wide and n. exc 1.5 m deep in trenches on soft soil and getting out complete all as specified and directed.
2Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each, complete, all as specified and as directed.
3Removing excavated spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified and as directed.
4Excavation in post holes in sof loose soil ( or similar holes) each not exc. 0.5 cum getting out, returning filling and ramming earth or broken rubble mixed with earth around, in layers not exc. 25 cm complete all as specified and directed.
5M&L for cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregates) in walls or retaining walls, any thickness, size or shape including pilasters, butresses columns, pillars, boundary pillars and posts (including caps and bases ) complete all as specified and directed.
6M&L PCC 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundations filling and mass concrete complete all as specified and directed.
7M&L PCC 1:2:4, type B-2 (using 20 mm graded stone aggregate) as in filling and mass concrete complete all as specified and directed.
8M&L for forming contraction (dummy) joints 30 cm deeep x 10 mm wide, filled with sealing compund grade 'A' complete all as specified and directed.
9M&L for cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregates) in foundation, filling and mass concrete and in surface channel or drains complete all as specified and directed.
10M&L for cement concrete (1:5:10) type E-2 (using 40mm graded stone aggregate) as in foundation, filling complete all as specified and as directed.
11M&L for 75 mm thick cement concrete 1:2:4 type B-1 (Using 20 mm graded stone aggregate) finished even and smooth without using extra cement as in plinth protection and joints shall be sealed with joint sealing compound grade 'A' complete all as specified and as directed.
12M&L for RCC 1:2:4 (nominal mix) type B-1 (using 20mm graded aggregate) for footing and plinth beam complete all as specified and directed.
13M&L for RCC 1:2:4 (nominal mix) type B-1 (using 20mm graded aggregate) for floor beams , roof beams, tie beams, gable beams complete all as specified and directed.
14M&L for RCC 1:2:4 type B-1 (using 20mm graded aggregate) for columns complete all as specified and directed.
15M&L for providing cast in situ RCC 1:2:4 type B-1 (using 20mm graded aggregate) as in cover slab of man hole covers and drains covers with 40 mm dia holes made in the slabs to drain off runoff complete all as specified and directed.
16M&L for formwork to sides of footings, plinth beams for rough finished surface for concrete complete all as specified and directed.
17M&L for formwork to sides of columns square or rectangle in plain for rough finished surface for concrete complete all as specified and directed.
18M&L for Formwork to soffits of floor or roofs beams, beam haunchings, gorders,bressummers, lintles, cantilever, shelves including sub- ports, overhangs etc. also splays between floors and beams complete all as specified and directed.
19S & F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
20S & F Mild steel TMT bars 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
21M&L for Brickwork in cement mortor 1:6 with flyash 'B' old size bricks, straight or curved on plan exc 6m mean radius built in etc complete all as specified and as directed.
22M&L for Brickwork ( except bricks) in cement mortor 1:6 with flyash 'B' old size bricks, straight or curved on plan exc 6m mean radius built in etc complete all as specified and as directed.
23M&L for brickwork with subclass flyash 'B' bricks, straight or curved on plan in any radius as in half brick wall, built in cement mortar (1:4) and pointed flush with the same mortar as the work proceeds , complete all as specified and directed.
24M&L for brickwork with subclass flyash 'B' bricks (except bricks), straight or curved on plan in any radius as in half brick wall, built in cement mortar (1:4) and pointed flush with the same mortar as the work proceeds , complete all as specified and directed.
25M&L for Brickwork with flyash bricks or brick tiles in brick-on-edge walls ( less than half brick thick) built in cement mortar (1:4) complete all as specified and as directed.
26M&L for Brickwork with sub class 'B' bricks (except bricks) in brick-on- edge walls ( less than half brick thick) built in cement mortar (1:4) complete all as specified and as directed.
27M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished fair & even in CM 1:4 mixed without using extra cement compound complete all as specified and directed.
28M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished fair & even in CM 1:6 mixed compound complete all as specified and directed.
29Taking down cement plaster of any description on brick walls or concrete surfaces etc. including racking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
30M&L for Preparation of new plastered wall surfaces of any description complete all as specified and applying the following: -(a) Applying wall care putty 1mm thick, in two coats & smoothening the surfaces with sand papers/ mechanized sanding etc., (preparatory to paint as directed). (b) Two coats of interior acrylic distemper/ distemper oil emulsion (OBD)over and including a coat of acrylic emulsion primer.
31M&L for Preparation of new plastered wall surfaces of any description complete all as specified and applying the following: -a) Applying wall care putty 1mm thick , in two coats & smoothening the surfaces as specified. (preparatory to paint as directed).complete all as specified. (b) Two coats of exterior acrylic emulsion over and including a coat of water based exterior primer in disruptive/camouflaging pattern of six/four shades complete all as specified and directed.
32M&L for cement concrete 1:2:4 type B-1 (using 20 mm graded aggregate) as in lintels upto 1.5 m clear span, cills, steps seismic and similar bands, plinth courses, lacing courese, parapets and railings utpo 60 cm in height, copings kneelers, apex stones, bed kerbs, kerbs not provided for in item 04028, water troughs and tke like including weatering slightly rounded or chamfered angles and throrating complete all as specified and directed.
33Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement , including forms mi-tred/ stopped ends complete all as specified and directed.
34M&L for mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket farming (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. quality conforming to grade Fe-290-Gde E-165 complete all as specified and directed.
35M&L for steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to ISI 1161-1979 grade St- 240 complete all as specified and directed.
36S&F mild steel plates (plain or checqured) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed.
37S&F Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) confirming to Fe-410- W (Gde E-250) Grade A complete all as specified and as directed.
38S&F prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of a colour having tensile strength of 550 Mpa as in roof covering to wall fixed with self tapping screw complete all as specified and directed.
39S&F prepainted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of a colour having tensile strength of 550 Mpa as in roof covering to wall fixed with self tapping screw complete all as specified and directed.
40S&F mild steel work for posts and struts in fencing including cutting tops to shapes as directed, drilling holes, notching for wire etc: flat iron fillets (For securing wire mesh etc) incl all necessary drilling bolting or riveting etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed by Engineer-in-Charge.
41S&F mild steel screw bolts ( Machine made ) 8 to 10mm dia of neck with hexagonal or square heads at one end and screwed the other, or screwed both ends each screwed end to fitted with washers and one hexagonal or square nuts exc 5cm but not exc 10cm long fixed complete all as specified and directed by Engr-in-Charge.
42supply only Mild Steel Round bars 10 mm dia and over cut to length bent to shape required including bending spirally , hooking ends and binding with steel wire (annealed) securing clips or welded with MS angle Conforming Fe-410-W (Gde.E-250) quality-A or Fe 290 (Gde - E-165)all as specified and directed by Engineer in-charge.
43S&F Framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to beprepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
44Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed.
45S&F in replacement Galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings withand provision of galvanised mild steel wire, staples or steel pins etc complete all as specified and directed.
46Tightening /restraining and resecuring of old existing barbed wire including making good staples etc in same position complete all as specified and directed.
47S&F in repair Concertina coil with punched tape 600 mm dia with high tensile galvanised wire having diameter not less than 2.5 mm and blade size 15 x 12 mm x 0.5 mm, spacing of blade not more than 26 mm, fixed in position over walls etc., complete all as specified and directed.
48Supply only chain link mild steel galvanised hot dipped fencing (mesh size not more than 75mm x 75mm of 10 gauge wire and weight exc. 3.00 kg/Sq.m) complete all as specified and directed.NOTE:- The weight of chain link fencing shall be ascertained by BOO as ordered by GE and payment shall be made acoordingly..
49M&L for Repairing of old chain link fencing, including removing from fillets, straining bolt, removing and refixing of post with PCC, if required and fixing in position in a straight line complete all as specified and as directed.
50M & L for 100 mm thick, Cement concrete type D-2, 1:4:8 (40mm graded aggregate), etc as in sub floors complete all as specified and directed.
51M&L for Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line , level and curvature,jointed withcement mortar 1:3 ( 1 cement : 3 coarse sand ) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm) , including making drainage opening whereever required complete all as specified and directed.
52M&L for Providing and laying 60 mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved design & pattern as in footpath , parks , lawns,drive ways or light traffic parking etc. of required strength , thickness & size/shape, made by table vibratory method using PU mould , laid in required pattern over and including 25 mm thick compacted bed of fine sand , compacting and proper embedding/laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator,filling joints with sand andcutting of paver block as per required size and pattern,finishing and sweeping extra sand complete all as specified and directed.
53M&L for Providing and laying 80 mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved design & pattern as in footpath , parks , lawns,drive ways or light traffic parking etc. of required strength , thickness & size/shape, made by table vibratory method using PU mould , laid in required pattern over and including 25 mm thick compacted bed of fine sand , compacting and proper embedding/laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator,filling joints with sand andcutting of paver block as per required size and pattern,finishing and sweeping extra sand complete all as specified and directed.
54Fixing only cement concrete paver block of any thickness as in footpath, parks, lawns, drive ways or light trafic parking etc. Including taking out paver block of any size from sunk portion with and including requisite PCC 1:4:8 type D-2 ( 40mm graded aggregate) exceeding 50 mm thick but not exc 100 mm thick and including 25 mm thick compacted bed of coarse sand , compacting complete all as specified and directed.
55M&L for Preparing steel and iron surfaces (new) of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer complete all as specified and directed.
56M&L reinforced concrete pipes , class NP-2 drain pipes laid in trenches and jointed as specified Internal diameter of pipe in 150 mm complete all as specified and directed.
57M&L reinforced concrete pipes , class NP-2 drain pipes laid in trenches and jointed as specified Internal diameter of pipe in 200 mm complete all as specified and directed.
58M&L for providing concrete bed in PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in bed to drain pipes of 150mm bore including packing under and haunching against the sides of the pipes completely after they are laid and tested complete all as specified and as directed by the Engineer-in-Charge.(Note: Width of concrete bed shall be outer diameter of drain pipe plus 30cm)
59M&L for providing concrete bed in PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in bed to drain pipes of 200mm bore including packing under and haunching against the sides of the pipes completely after they are laid and tested complete all as specified and as directed by the Engineer-in-Charge.(Note: Width of concrete bed shall be outer diameter of drain pipe plus 30cm)
60Maintenance of drain /Nallah by cutting all bushes, shrubs, sarkandas and any type of vegetation and desilting all deposit of soil and other material to have a free flow of water and to get a uniform trapezoidal/ rectangular shape of drain and removing all spoil from MOD area to a distance exc 250m but n exc 500m and deposited in layer n exc 25cm thick , cross sectional area of drain /nallah n exc 1.5 sqm complete all as specified and directed
61M&L for Bitumen blown any grade, applied hot, two coats, to concrete surfaces at the rate of 1.5kg. per sq. m per coat as in Damp proof course including cleaning surfaces etc, complete all as specified and directed.
62Demolition of stone/ boulder, brick work built in cement mortar including all quoins, arches, pillars etccomplete all as specified and directed.
63Demolition of un-reinforced cement concrete in ground floor and paving not exceeding 15 cm thick (below or above ground level) complete all as specified and directed.
64Demolition of reinforced cement concrete in ground floor and paving not exceeding 15 cm thick (below or above ground level) complete all as specified and directed.
65Dismantling of old chain link fencing of any description of weight not exc. 4.0 kg/sqm from existing fencing fixed with steel or concrete posts complete all as specified and directed.
66Dismantling posts or strutts (wood, steel or RCC) any section including taking out embedded portion (post embeded in concrete, brick work etc.) and making good the disturbed ground complete all as specified and directed.
67Demolition and breaking up of drain pipes ( salt glazed ware or AC or reinforced cement concrete) set in cement mortar of 150 mm dia complete all as specified and directed.
68Demolition and breaking up of drain pipes ( salt glazed ware or AC or reinforced cement concrete) set in cement mortar of 200 mm dia complete all as specified and directed.
69Dismantling unframed timber scantlings 40 sqcm and over in section , in any position complete all as specified and directed.
70Dismantling framed timber scantlings 40 sqcm and over in section , in any position complete all as specified and directed.
71Dismantling framed timber scantlings in filltets, rails, posts, rafters, purlins etc under 40 sqcm , in any position complete all as specified and directed.
72Disamntling asbestos cement (corrugated, semicorrugated etc.) sheets in roof coverings complete all as specified and directed.
73Dismantling of wrought iron of mild steel work of any description in any position not otherwise specifically provided for complete all as specified and directed.
74Notes: Amount of credit for retrieved materials is mentioned in tender documents in pdf form which will be deducted while acceptance of tender offline. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57081140
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45 Lakhs
LAST DATE 10-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Certain Repairs To Fencing, Gate,Cgi Sheets, Culverts Drain, Reinforced Cement Concrete Cover, And Hardstanding In Area Under Age B/R-Ii At Af Stn Ad Ur
Basic Detail
Tender No GE(AF)/ADM/T-39 OF 2026-27
Bidding Type Tender
Location
City Jalandhar
State Punjab
Key Dates
Publish Date 19 Aug 2026
Submission Date 10 Sep 2026
Open Date 12 Sep 2026
Finance
Tender Value 45 Lakhs
Tender Fee 500
EMD 90000
Exemption Available
Document List
93b7099a-364a-42a3-8f3e-67717e8ced65.html
BOQ_879766.xls
tender.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Sep 12, 2026

Bid Opening Date

Technical bids will be opened and evaluated.