Tender For Construction Of Synthetic Volleyball Court At Govt. Hs Kaneri Distt Jammu Under Ut Capex Buget 2026-27
Tender Value
23.10 Lakhs
Estimated cost
Bid Submission
29 Aug 2026
0 days left
EMD
46200
Bank guarantee accepted
Document Fee
600
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jammu → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Synthetic Volleyball Court At Govt. Hs Kaneri Distt Jammu Under Ut Capex Buget 2026-27
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as10 sqm on plan including disposal of excavated earth, leadupto50meterand lift upto 1.5m, as directed by Engineer-in-Charge. All kinds of soil |
| 2 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge All kinds of soil : |
| 3 | Excavating, supplying and filling of local earth (RBM) (including royalty)by mechanical transport upto a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 4 | Treatment of soil using chemical like round up for anti weeding laid in holes @ 300 mm c/c and consumpution @ 600 ml/ 10 Sqm |
| 5 | Consolidation of subgrade with power road roller of 8 to 12 tonne capacity including making good the undulations etc. with earth or quarry spoils etc. and rerolling the subgrade |
| 6 | P/L and compacting stone agrregates of different sizes to form contour and elevation to the desired level as per the Drawing and instruction of Engineer Iincharge (size 40 mm /20 mm/10mm ) down black stone aggregate up to a depth of 300 mm from below primary backing . Layers of stone to be rolled as per desired slope and compaction using 8-10 tonnes Road roller over open area & pitch roller over areas with drainage pipes. |
| 7 | Supply and installation of artificial UV resistanat polyethylene synthetic grass with rigid monofilment yarn, minimum 40mm pile height.The turf should have minimum 40mm Pile Height made of POLYETHYLENE Monofilament & Pile weight minimum 900 g/m2 and above and stitched rate minimum @ 120/ mtr or above. The turf should have Dtex/Denier >=12300. The Primary backing of turf should be made of 100% POLYPROPYLENE, minimum weight 240 gram/m2 and above with Coating with Carboxylated SBR Latex appr. 1200 gr/m2 or Butadiene Styrene with weight of 900 g/sqm and total backing wt should not be less than 1140 g/sqm or as approved by FIFA under FIFA Quality/ FIFA Quality Pro Category.The Product shall be procured from FIFA Prefered Provider and FIFA Standard Licencee of European / American Make onlyThe infill must be 15-20 Kg Silica Sand, minimum 15-20 kg & above SBR Rubber Granules. The line marking shall be stitched tufted material (Painted lines are not acceptable). The rate is inclusive of All applicable taxes, Lavies, Octoria, transportation loading/unloading complete except custom duty exemption & Including Maintenance of 3 years by way of brushing and adding infill as and when required. |
| 8 | Providing of Fixing Height Adjustable Fixed Volley Poles 4 INCH with Net ( Yonex or Spartan made ) and Anteena |
| 9 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering . All works upto plinth level 1:4:8 mix (1 cement: 4 coarse sand:8 graded stone aggregates) 40 mm nominal size (crushed) |
| 10 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 11 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 12 | Centring and shuttering including strutting, propping etc. and removal of form work for Lintel, beams, plinth beams, girders, bressumers and cantilevers |
| 13 | Steel work welded in built up section framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer. |
| 14 | Providing and fixing G.I Chain link Fabric fencing of required width in mesh size 50x50mm including strengthening with 2mm dia wire or nuts, bolts and washers as required complete as per direction of Engineer in Charge Made of G.I wire dia 4mm |
| 15 | Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) |
| 16 | Applying priming coat: With ready mixed red oxide Zinc Chromate primer of approved brand and manufacture on steel galvanized iron/steel works |
| 17 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coat on new work |
| 18 | Supply and laying of PVC insulated and PVC Sheathed/xlpe aluminium power cable of 1.1 KV grade of vfollowing sizes on surface/direct in ground including sand cushioning protective covering and refiling the trench as required as per direction of Engineer Incharge 16 sq. mm 2 core |
| 19 | Supply and fixing of following sizes of medium class PVC conduct along with accessories in surfcae/recess including cutting the wall and making good the same in case of recessed conduct as required 20 mm |
| 20 | Supplying and fixing End Box (Loss Wire Box) suitable for following single pole and neural, sheet steel, MCB distribution board 240 Volts on surface/recess, complete with testing and commissioning etc as required for 6 way, Double door SPN MCBDB |
| 21 | Supply and fixing 5 A to 32 A rating240/415 V,10 KA, \\"C\\" curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required Single pole and netural 32 Amp |
| 22 | Supplying and fixing 5 amps to 32 amps rating 240 volts 'C' series, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required Single Pole |
| 23 | Installation, Testing and commissioning IP 66 Flood lights 200 watt minimum uminous flux of luminaire 120 Lm/w, colour temperature of 5700 K, netural white , CRI>80,50,000 operating hours with PC lense and necessary wire for connection and other accessories required for fixing lights on exiting poles. Firm has to submit originallity certificate of material from OEM or Authorized Distributor with 05 years of warranty |
| 24 | Providing and fixing ACP main board 3mm thickness on 1 x 1 inch tubular frame with writing of Name of stadium etc as per direction of engineer incharge |
| 25 | carriage of sand for distance of 30 Kms by mt |
| 26 | carriage of stone aggregate for distance of 40 Kms by mt |
| 27 | Provision for supply and Installation of Pedestal for Inaguration / Foundation made of Brick work with Tile work for fasard and Granite Plate of size 3 feet X 2 feet 6 inch as per direction of Engineer in chrage Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedAug 31, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender