Power Boards / Undertakings / PSU Closing in 10 days TDR #57080598

Tender For Augmentation Work Of (+) 01 Nos 220/132 Kv 200 Mva Power Transformer In Place Of ( - ) 01 Nos 220/132 Kv 100 Mva Power Transformer At 220 Kv Gss Rvpnl , Lalsot

Issued by Boards / Undertakings / PSU · Dausa, Rajasthan
Tender Value
9.65 Lakhs
Estimated cost
Bid Submission
01 Sep 2026
10 days left
EMD
19318
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Dausa → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Augmentation Work Of (+) 01 Nos 220/132 Kv 200 Mva Power Transformer In Place Of ( - ) 01 Nos 220/132 Kv 100 Mva Power Transformer At 220 Kv Gss Rvpnl , Lalsot

BOQ

Name of Work:- AUGMENTATION WORK OF (+) 01 NOS 220/132 KV 200 MVA POWER TRANSFORMER IN PLACE OF ( - ) 01 Nos 220/132 KV 100 MVA POWER TRANSFORMER AT 220 KV GSS RVPNL , Lalsot
Sl. No. Item Description
1Laying of earth mesh with 25mm / 28mm dia M.S. Rod at a depth of 0.80 metre from top level of foundation, including excavation of trench of required depth and backfilling of the same, transportation of M.S. Rods from site store to location, welding of M.S. Rod to M.S. Rod along the length, at crossings and with earth electrodes as per drawing, application of bitumen compound and covering with bitumen impregnated tape on all welded joints, for the type of soil prevalent at 0.80 metre below top level of foundations (M.S. Rod of above sizes & M.S. Flat as required shall be made available by RVPN).(a) In case electricity is made available by RVPN without charges. i) Any soil, soft rock other than hard rock
2Laying of earthing risers of 50x6mm / 50x10mm / 50x12mm size M.S. Flat at a depth of 0.80 metre from top level of foundations, including excavation of trench of required depth and back filling of the same, transportation of M.S. Flat from site store to locations, preparation of risers, bending as per reqiurement (after heating if necessary), fixing on & belding / bolting of equipment / structure & peaks of structure, laying in the trench, welding to earth mesh of M.S. Rod as per drawing, including welding of extra length of M.S. Flat if required, application of bitumen compound and covering with bitumen impregnated tape on all welded joints, painting of all surfaces of risers above ground level with red oxide and green paint, for the type of soil prevalent at 0.80 metre below top level of foundations (M.S. Rod of above sizes & M.S. Flat as required shall be made available by RVPN).(a) In case electricity is made available by RVPN without charges.i) Any soil, soft rock other than hard rock
3Placing / Driving of earth electrode of 25 / 28mm dia. M.S. Rod of length 3.30 metres (approx.) to a depth of 3.80 metres from the top level of foundations, including excavation of pit as required and back filling of the same, transportation of M.S. Rod from site store locations, cutting of M.S. Rod to desire length, preparation of one end as as spike if necessary, welding of earth electrode to earth mesh of M.S.Rod as per drawing, application of bitumen compound and covering with bitumen impregnated tape on all welded joints, for the type of soil prevalent at 3.80 mtrs below top level of foundations (M.S. Rod of above sizes & M.S. Flat as required shall be made available by RVPN).(a) In case electricity is made available by RVPN without charges. i) Any soil, soft rock other than hard rock
4STRINGING of 220KV, 132KV, 33KV & 11KV Bus Bar of ACSR & Tarantulla conductor including transportation of conductor, disc insulator & tension hardware from site store to location, laying & cutting required length of conductor, cleaning & assembly of disc insulators as required along with fitting of bolted type or compression type tension hardware as made available between the beams with specified sag and tension, also equilising sag and fitting spacers and spacer T-clamps for twin conductor for three phase of conductors in each sub-section.(Per jumper basis) i) Any Double Conductor
5JUMPERS of ACSR conductor (3 nos. Y-type) between bus to equipment or between equipment to equipment or between bus to bus, including transportation of conductor, disc insulators and hardware from site stores to locations, cleaning & assembly of disc insulators as required along with fitting of suspension hardware and erection as required length of conductor, making connections, fixing of spacers & spacer T-clampsas required, tightening of clamps / connectors, dressing etc., for three phases.(Per jumper basis)
6Erection of CONTROL & RELAY PANALS complete in all respects including transportation from site store to control room, placing on foundation / cable trench as per layout, interconnection between Control & Relay panels and with existing panels, fixing of side / top covers and doors, earthing to existing earth strip in control room, connection of bus wiring to existing panel and between control and relay panel as required iii) Simplex Panel, DC Panel, RTCC Panel, PLCC Panel etc
7Erection of Current Transformer / Potential Transformer / Capacitive Voltage Transformer / Series Reactor / Residual Voltage Transformer / Neutral Current Transformer with clamps & connectors on already erected steel structure including transportation from site store to locations, fabrication of base frame, fixing of terminal connectors, tightening of nuts & bolts etc, complete in all respects. iii)132 KV CT/PT/CVT
8Erection of 1220 KV Class EHV Transformer (tank already placed on foundation with wheels) including transportation of accessories from site store to locations, erection of HV, IV, LV & Neutral bushings, main & OLTC conservators, radiators, equilizing pipe line, marshalling kisok etc as per manufacturer's drawing, preparation of oil, oil filling, dehydration of transformer (filter machine, oil tank & operating staff shall be provided by RVPN), electrical wiring from individual equipment e.g. Buchholz Relay, MOLG, OSR etc to marshalling kiosk etc but excluding testing & commissioning of transformer.(a) If electricity is available & arranged by RVPN without charges. i) Transformer received Oil filled
9ERECTION OF MARSHALLING KIOSK / Line Matching Unit (LMU) / Line Matching & Distribution Unit (LMDU) complete in all respect including transportation from site store to location, placing on foundation / cable trench as per layout, preparing for grouting of foundation bolts but excluding grouting etc. i) 220 KV or 132 KV Marshlling Kiosk
10i) Laying of PVC insulated unarmoured / armoured control cables of 1.1 KV grade with copper conductor in cable trenches as per specification as required, including transportation of cable drums from site store to locations, laying in cable treches, cutting of required length, placing them on cable racks / cable trays / cable batten & dressing, including removing and re-fixing trech covers as required , making necessary connections, testing, cable marking on both the terminating ends etc as required for all sizes from 2C x 2.5 sq. mm. to 20C x 2.5 sq. mm, 4C x 4 sq. mm and 4C x 6 sq. mm. b) Armoured control cable
11ii) Fixing of control cable in position with single compression nickel plated brass cable glands confirming to IS: 12943 & having three metal washers and one rubber ring, including preparation of cable and drilling of corresponding holes in gland plates etc as required & including cost of cable glands for each cable gland size a) 19 mm unarmoured control cable
12ii) Fixing of control cable in position with single compression nickel plated brass cable glands confirming to IS: 12943 & having three metal washers and one rubber ring, including preparation of cable and drilling of corresponding holes in gland plates etc as required & including cost of cable glands for each cable gland size c) 25 mm unarmoured control cable
13ii) Fixing of control cable in position with single compression nickel plated brass cable glands confirming to IS: 12943 & having three metal washers and one rubber ring, including preparation of cable and drilling of corresponding holes in gland plates etc as required & including cost of cable glands for each cable gland size e) 32 mm unarmoured control cable
14iii) Termination of wires of cables with copper conductor using copper terminal ends (pin or ring type as required of Dowell's or equivalent make as approved by the Engineer - In - Charge) duly crimped with crimping tool, including making wire ends ready for crimping, ferruling & dressing of wires etc as required including cost of terminal ends for all wires for each cable at both ends for cables of the following sizes.a) 2.5 Sqmm for any number of core
15iii) Termination of wires of cables with copper conductor using copper terminal ends (pin or ring type as required of Dowell's or equivalent make as approved by the Engineer - In - Charge) duly crimped with crimping tool, including making wire ends ready for crimping, ferruling & dressing of wires etc as required including cost of terminal ends for all wires for each cable at both ends for cables of the following sizesb) 4 Sqmm for any number of core
16Dismentaling of 220KV, 132KV, 33KV & 11KV Bus Bar of ACSR & Tarantulla conductor including transportation of conductor, disc insulator & tension hardware from site store to location, laying & cutting required length of conductor, cleaning & assembly of disc insulators as required along with fitting of bolted type or compression type tension hardware as made available between the beams with specified sag and tension, also equilising sag and fitting spacers and spacer T-clamps for twin conductor for three phase of conductors in each sub-section.(Per jumper basis) 9i0 any single conductor
17Dismentaling of JUMPERS of ACSR conductor(3 nos Y type)between equipment or between bus to bus,including transportion of conductor,disc insulators and hardware from site stores to locations ,cleaning and assembly of disc insulators as along with fitting of suspension hardware and erectoin as reqired, cutting reqired length of conductor, making connections,fixing of spacers & spacer T-clamps as reqired,tightiening of clamps/connectors,dressing ect. For three phases.(Per jumper basis) (i) nay conductor
18DISMENTELLING of Current Transformer / Potential Transformer / Capacitive Voltage Transformer / Series Reactor / Residual Voltage Transformer / Neutral Current Transformer with clamps & connectors on already erected steel structure including transportation from site store to locations, fabrication of base frame, fixing of terminal connectors, tightening of nuts & bolts etc, complete in all respects. i) 132 KV CT / PT / CVT
19DISMENTALLING 220/132 KV 100 MVA of 220 KV Class EHV Transformer (Gas filled tank already placed on foundation with wheels ) including transportation of Accessories from site store to location , Erection of HV , IV , LV & Netural bussing tank already placed on foundation with wheels) including transportation of accessories from site store to locations, erection of HV, IV, LV & Neutral bushings, erection of cooler bank with associated pipe line , radiators , fans , pumps main & OLTC Conservators , Equalizing pipe line , marshalling Kisosk , etc. as per manufacturer's drawing prepration of oil , oil filling , dehydration of transformer along with cooler bank & diverter switch (filter machine, oil tank & operating staff shall be provided by RVPN), electrical wiring from individual equipment e.g. Buchholz Relay, MOLG, OSR etc to marshalling kiosk etc but excluding testing & commissioning of transformer.(a) If electricity is available & arranged by RVPN without charges. i) Transformer received GAS Filled
20Dismentling of CONTROL & RELAY PANALS complete in all respects including transportation from site store to control room, placing on foundation / cable trench as per layout, interconnection between Control & Relay panels and with existing panels, fixing of side / top covers and doors, earthing to existing earth strip in control room, connection of bus wiring to existing panel and between control and relay panel as required iii) Simplex Panel, DC Panel, RTCC Panel, PLCC Panel etc
21i)un Laying of PVC insulated unarmoured / armoured control cables of 1.1 KV grade with copper conductor in cable trenches as per specification as required, including transportation of cable drums from site store to locations, laying in cable treches, cutting of required length, placing them on cable racks / cable trays / cable batten & dressing, including removing and re-fixing trech covers as required , making necessary connections, testing, cable marking on both the terminating ends etc as required for all sizes from 2C x 2.5 sq. mm. to 20C x 2.5 sq. mm, 4C x 4 sq. mm and 4C x 6 sq. mm.(a) Unarmoured Control Cable
22ii) unlaying and de termination of cable of control cable in position with single compression nickel plated brass cable glands confirming to IS: 12943 & having three metal washers and one rubber ring, including preparation of cable and drilling of corresponding holes in gland plates etc as required & including cost of cable glands for each cable gland size a) 19 mm unarmoured control cable
23ii) unlaying and de termination of control cable in position with single compression nickel plated brass cable glands confirming to IS: 12943 & having three metal washers and one rubber ring, including preparation of cable and drilling of corresponding holes in gland plates etc as required & including cost of cable glands for each cable gland size c) 25 mm unarmoured control cable
24ii) unlaying and de termination of control cable in position with single compression nickel plated brass cable glands confirming to IS: 12943 & having three metal washers and one rubber ring, including preparation of cable and drilling of corresponding holes in gland plates etc as required & including cost of cable glands for each cable gland size e) 32 mm unarmoured control cable
25iii) DE Termination of wires of cables with copper conductor using copper terminal ends (pin or ring type as required of Dowell's or equivalent make as approved by the Engineer - In - Charge) duly crimped with crimping tool, including making wire ends ready for crimping, ferruling & dressing of wires etc as required including cost of terminal ends for all wires for each cable at both ends for cables of the following sizes.a) 2.5 Sqmm for any number of core
26iii) DE Termination of wires of cables with copper conductor using copper terminal ends (pin or ring type as required of Dowell's or equivalent make as approved by the Engineer - In - Charge) duly crimped with crimping tool, including making wire ends ready for crimping, ferruling & dressing of wires etc as required including cost of terminal ends for all wires for each cable at both ends for cables of the following sizesb) 4 Sqmm for any number of core
27Dragging/shifting charges for 220/132 KV, 100 MVA Power Transformer from Track to new location at 220 KV GSS lalsot
28Air Dryer Generator unit for erection/installation work of 220/132 KV, 200 MVA Transformer, at 220 KV GSS RVPNL , Lalsot .
29Dehydration/Filtration and reconditioning of transformer oil of 220/132 KV 200 MVA power transformer at 220 kV GSS Lalsot( by providing high vacuum filtration machine and oil testing kit having 100 KV Capacities as per norms and testing (Electricity supplied by department ) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57080598
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 9.65 Lakhs
LAST DATE 01-09-2026
Authority
Authority Name Rajasthan Rajya Vidhyut Utpadan Nigam Limited
Work Description Tender for Augmentation Work Of (+) 01 Nos 220/132 Kv 200 Mva Power Transformer In Place Of ( - ) 01 Nos 220/132 Kv 100 Mva Power Transformer At 220 Kv Gss Rvpnl , Lalsot
Basic Detail
Tender No TN-10/2026-27
Bidding Type Tender
Location
City Dausa
State Rajasthan
Key Dates
Publish Date 19 Aug 2026
Submission Date 01 Sep 2026
Open Date 01 Sep 2026
Finance
Tender Value 9.65 Lakhs
Tender Fee 1180
EMD 19318
Exemption Available
Document List
3fc2af86-1f96-498d-b1f3-30fb5d6a5413.html
BId10.pdf
BOQ_1042956.xls
Tendernotice_1 (52).pdf
Tendernotice_2 (10).pdf
TN10.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Sep 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

3fc2af86-1f96-498d-b1f3-30fb5d6a5413.html

pdf

BId10.pdf

xls

BOQ_1042956.xls

pdf

Tendernotice_1 (52).pdf

pdf

Tendernotice_2 (10).pdf

pdf

TN10.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders