Defence Statutory Bodies & Commissions/Committees Closing in 17 days TDR #57080476

Tender For Repair And Maintenance Of Winter Appliances, Geysers, Solar Water Heater At Af Station Jammu And Kaluchak Under Ge(Af) Jammu

Issued by Statutory Bodies & Commissions/Committees · Jammu, Jammu and Kashmir
Tender Value
28 Lakhs
Estimated cost
Bid Submission
09 Sep 2026
17 days left
EMD
56000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jammu → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair And Maintenance Of Winter Appliances, Geysers, Solar Water Heater At Af Station Jammu And Kaluchak Under Ge(Af) Jammu

BOQ

Name of Work:- REPAIR AND MAINTENANCE OF WINTER APPLIANCES, GEYSERS, SOLAR WATER HEATER AT AF STATION JAMMU AND KALUCHAK UNDER GE(AF) JAMMU
Sl. No. Item Description
1M&L for servicing solar FP collector by removing the flange plates, cleaning the collectors internally by using Descalo solution, removing the blockages in the collectors and refixing the flange plates, testing for satisfactory function all as specified and directed by Engr-in-charge.Solar Make : Kotak, inter Solar.
2M&L for servicing solar manifold and tank by removing all the tubes in the monifold, cleaning the tubes internally, removing the blockages in the tubes and cleaning the tank and removing all the impurities, assembling and testing for satisfactory funtion complete all as specified and directed by Engr-in-Charge. Solar Make : Kotak, inter Solar.
3S&F in repairs heating element 25mm to 32mm dia, ISI marked for solar water heating plant of capacity 3KW complete all as specified and directed by Engr in charge. Make : Kotak, inter Solar
4S&F in repairs flange plates of size 25 mm dia suitable for flat plate collectors complete all specified and directed by Engr-in-Charge.Solar Make : Kotak, Inter Solar.
5S&F in repairs thermostat for solar water heating plant suitable size and ratings etc complete all as specified and directed by Engr-in-Charge. Solar Make : Kotak, inter Solar
6S&F in repairs flexible heat resistance rubber pipe (from inter connect plate collector to hot water tank) of size 25 mm to 32 mm dia etc with fixing clamp etc complete all as specified and directed by engr-in-charge.. Solar Make : Kotak,Inter Solar
7Taking down the Solar water heater collector from its position, removing the top glass of collector and carry out welding/brazing work to the collector and arresting the leakages in the collector, refixing top glass back, testing for satisfactory function including servicing, descaling etc complete all as specified and directed by Engr-in-Charge. Make : Kotak, Inter Solar
8M&L for sub main wiring with two run of 2.5 sqmm single core multi stranded PVC insulated and unsheathed copper conductor (red for phase and black for neutral) of grade 1100 volt FRLS cable in and including electrical grade PVC conduits of desired colour not less than 1.2 mm thick and of 25 mm dia & 2.5 sqmm copper conductor cable PVC unsheathed green coloured for earthing with complete accessories duly connected with earth dolly complete all as specified and directed by engr-in-charge. incl taking down old unserviceable one.
9Repair, maintenance and servicing of storage type electric water heater (geyser) of capacity 25 to 50 litres comprising of the following tasks at different locations including taking down, transportation to work shop, opening the geyser, replacement of defective spares and reinstalling the same including testing as directed by Engineer-in-charge.
10Note :-(a) Inspection of geysers includes taking down, transporting to works shop for repair, (dismantling) opening descaling, brushing cleaning of storage tank(b) Check and correct earth continuity of electrical items(c) Replacement of neon lamp / indicator lamp if defective.(d) Inspect over flow/vent pipes and remove blockage/ obstructions if any.(e) Examine water tightness tank after cleaning and necessary measures to make the same water tight if not.(f) Check thermostat for its proper functioning(g) Visual examination of fusible plug to ensure its intactness.(h) Checking of dead weight type high pressure release valve ( PRV ) by removing dead weight protection cleaning the seat and ensuring that the vent hole is not blocked / chocked.i) Descalling of the immersion type heating element and cleaning with diluted hydrochloric acid and refixing.j) Checking and adjustments of pressure reducing valves, carrying out operation of all stop cocks & ensure free movement of all working parts.k) Replacement of the rubber / PVC gasket to ensure water tightnessl) Testing of Geysers after repairsm) Replacement of defective components such as thermostat safety valves fusible plug, Heating elements/Glass line elements , storage tank apparatus plate etc. Note:- Spare components will be measured and paid separately as supply only under relevent item of Sch 'A'. These parts shall be of the same make of which the geyser is in repair.n) Replacement of plug and top to refixing with new.o) Inspection and repair of seal gaps,crack and joints in the insulating material .
11S&F Of Glass line Heating element 2KW Suitable with all Make og Geyser complete with all accessories complete all as specified directed by Engr-in-Charge.
12Supply only Heating element with rubber washer ('O' ring) cap 1.5KW/2 KW, trangular/round any type of geyser and any make of geyser complete all as specified and directed by engr-in-charge.
13Supply only indicator bulb neon round / square type single phase 230 Volt complete all as specified and directed by engr-in-charge.Make: Legrand/Schenieder/Havells/Bajaj
14Supply only Safety plug 15mm ( brass ) for geyser cap 25/50 Ltrcomplete all as specified and directed by engr-in-charge. Make: As per recommendation of manufacturer's of Geyers of approved makes
15Supply only Thermostat 30°C to 70°C, 230 Volts complete all as specified and as directed.Make- Bajaj / Theetta / Micron / DasPass
16Repair the leakge of copper/steel inner tank of geysers of any capacity by gas welding/brazing for water tightness complete and test under pressure. complete all as specified and directed by engr-in-charge.
17Supply only gasket rubber ring for heater plate of any size geyser complete all as specified directed by Engr-in-Charge.
18Supply only non return valve (NRV) brass of 15mm bore, after dismantling old unserviceable NRV of any size complete all as specified and directed by engr-in-charge.
19Supply olny PUF spray 500 ml ,used to seal gaps, cracks and joints and to provide high performance for geysers by offering thermal and acoustic insulation, complete with all accessories and complete all as specified and directed by Engr-in-Charge.
20Taking down loose geysers of any capacity from wall & shifting to new place within 1 to 1.5m distance (available in same location) , refixing the geysers complete with fastners and grouting of bolts & all necessary pipe connections and making good the disturbed wall surfaces complete all as specified and directed by engr-in-charge. Note :- GI tubing if required shall be measured and paid separately.
21S&F in repairs MCB SPN 32 Amp, 240 volts, 50Hz, C series of breaking capacity 10 KA, complete all as specified and directed by engr-in-charge..
22S&F in repairs MCB SP 20 Amp, 240 volts, 50Hz, C series of breaking capacity 10 KA,complete all as specified and directed by engr-in-charge.
23S&F in repairs PVC connection 450 mm long complete with brass nut, washers, seals, etc suitable for hot & cold water fixed in repairs complete all as specified and directed by engr-in-charge.
24S&F in repairs PVC connection 600 mm long complete with brass nut, washers, seals, etc suitable for hot & cold water fixed in repairs complete all as specified and directed by engr-in-charge.
25S&F Multi core round PVC insulated copper conductor PVC sheathed cable, 1100 Volts grade cable 3 core 2.5 Sqmm complete all as specified and directed by engr-in-charge. Make: Plaza/Havells/Polycab/Anchor
26S&F switch socket combination but 15A/16A, 5 in 1 flush type universal with fuse & neon incator including taking down old u/s socket outlet of any type complete all as specified and directed by engr-in-charge.
27S&F Bib taps, 15mm dia fancy type, with crutch or butterfly handle screwed down, screwed for iron pipe or for brass furrule and fixed in repairs complete all as specified and directed by engr-in-charge.
28S&F in repairs for stop valve/angle valve cast copper alloy, screw down high pressure, crutch handle screwed both end for iron pipe, fancy type, chromium plated for 15mm bore pipe.complete all as specified and directed by engr-in-charge.
29Taking up or down steel tubing 15mm bore dia and connection, including for refixing or removal to store complete all as specified and directed by Engr-in-Charge.
30M&L for 15mm dia bore galvanized steel water tubing, “medium grade,” together with all fittings; (ISI marked) such as elbows, bends tees, nipples, union sockets, sockets etc and short pieces and fixed complete to walls and ceilings or laid in floors/trenches complete including taking up or down old GI tubing complete all as specified and directed by engr-in-charge.
31S&F geyser water (inlet/outlet) assembly for geyser cap 25 Ltr of any type and any make of Geyser complete all as specified directed by Engr-in-Charge.
32Supply only geyser water (inlet/outlet) assembly for geyser cap 50 Ltr of any type and any make Geyser complete all as specified directed by Engr-in-Charge.
33S&F top/bottom plate of size suitable for 25 litres capacity geyser with new machine screws complete all as specified and directed by engr-in-charge..Make: As per recommendation of manufacturer's of Geyers of approved makes
34S&F top/bottom plate of size suitable for 50 litres capacity geyseras per existing type and make with new machine screws complete all as specified and directed by engr-in-charge.
35S&F Copper tube heavy duty 1/2\\" dia complete all as specified and directed by engr-in-charge.Make: As per recommendation of manufacturer's of Geyers of approved makes
36S&F Copper tube heavy duty 3/8\\" dia complete all as specified and directed by engr-in-charge.Make: As per recommendation of manufacturer's of Geyers of approved makes
37S&F in repairs electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc and deposite into MES store complete all as specified and directed by engr-in-charge.
38S&F in repairs electric water heater, storage type steel body with copper inner tank and heating element upto 3 KW capacity 50 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc.and deposite into MES store complete all as specified and directed by engr-in-charge.
39M&L for painting of geyser and also written MES No on geyser complete all as specified and directed by Engineer-in-Charge.
40Supply only 15/20Amp pulg top three pin type with 240 volts, 50Hz complete all as specified directed by Engr-in-Charge.
41S&F in repairs Geyser safety power cord 3 pin 16 Amps 240 V With ELCB Tripper Switch For any type Geyser complete with all accessories complete all as specified directed by Engr-in-Charge.
42S&F of Capillary cut out of geyser suitable with all make of geyser complete with all accessories complete all as specified directed by Engr-in-Charge.
43S&F of Capillary Type adjustable thermostat with 2 pin suitable with all make of geyser complete with all accessories complete all as specified directed by Engr-in-Charge.
44S&F in repairs of Instant Geyser with capacity of tank upto 3 ltrs body compact type BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. and deposite into MES store complete all as specified and directed by engr-in-charge.
45S&F in repairs steel tank of geyser capacity 25 ltrs complete all as specified and directed by engr-in-charge.
46S&F in repairs steel tank of geyser capacity 50 ltrs complete all as specified and directed by engr-in-charge.
47Repair, maintenance and servicing of storage type electric water heater (geyser) of capacity 500 litres including taking down, transportation to work shop, opening the geyser,descaling and reinstalling the same including testing as directed by Engineer-in-charge.
48SCHEDULE 'A' PART-II (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch 'A' Part-II of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57080476
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 28 Lakhs
LAST DATE 09-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair And Maintenance Of Winter Appliances, Geysers, Solar Water Heater At Af Station Jammu And Kaluchak Under Ge(Af) Jammu
Basic Detail
Tender No CA NO GE/AFJ-51/2026-27
Bidding Type Tender
Location
City Jammu
State Jammu and Kashmir
Key Dates
Publish Date 19 Aug 2026
Submission Date 09 Sep 2026
Open Date 16 Sep 2026
Finance
Tender Value 28 Lakhs
Tender Fee 500
EMD 56000
Exemption Available
Document List
BOQ_879550.xls
cfc16ed7-1d2c-48af-ab62-aa2cd526089f.html
Tender51.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Sep 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 24 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_879550.xls

html

cfc16ed7-1d2c-48af-ab62-aa2cd526089f.html

pdf

Tender51.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders