Tender For Replacement Of Very Old And Damaged Lt Panel And Allied Works At Pkt-10B Dda Flat Jasola Vihar Bps In Okhla Constituency Ac-54.

Issued by Boards / Undertakings / PSU · Delhi, Delhi
Tender Value
Ref. Documents
Estimated cost
Bid Submission
26 Aug 2026
2 days left
EMD
14900
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Replacement Of Very Old And Damaged Lt Panel And Allied Works At Pkt-10B Dda Flat Jasola Vihar Bps In Okhla Constituency Ac-54. , Lt Distribution Panel Sheet Steel Enclosure Made Out Of 2 Mm Crca Sheet Totally Enclosed, Powder Coated Free Standing, Floor Mounted Type, Dust& Vermin Proof, Outward Opening, Lockable Doors Having Hidden Hinges And A Bolted Back Cover Both Using Non-Deteriorating Neoprene Rubber Gaskets To Provide Ip-54 Protection .The Each Part Of The Fabricated Panel Will Be Strictly Subjected To Seven Tank Treatment. The Various Components, Assemblies And Sub Equipments Of The Panel Will Be As Per Standard Given In Relevant Is. The Bus Bar Of The Panel Will Be Shaped Out Of High Conductivity, Electrolytic Conductor And Shall Be Liberal Sized In Aluminium. The Control Wiring Of The Panel Will Be Done With Pvc Flexible Copper Wires Of 1.5 Mm Cross Section. Each Wire Will Be Terminating With A Ferule Crimped To The Wire. The Panel Size Must Be Of 1800Mmx1800mmx450mm Mounted On Ms Angle Having 4 Legs Of 1 Feet Height. , Mccb 125 Amp. 4 Pole 3Phase High Breaking Capacity 50Ka 50Hz, 430V With Spreader & Handle Make : L&T/ Siemens/ Schneider/ Havells/ Djb Approved Make.. , Mccb 63 Amp. 4 Pole 3Phase High Breaking Capacity 50Ka 50Hz, 430V With Spreader & Handle. Make: L&T/ Siemens/ Schneider/ Havells/ Djb Approved Make. , Mccb 415V, 4 Pole, 3 Phase 50Ka 50Hz, 40 annual periodical maintenance With Spreader & Handle. Make : L&T/Siemens/Schneider/Havells/Djb Approved Make.. , Mcb Single Pole 6 Amp. Make:- L&T/Havells/Schneider/ Djb Approved , Mcb Triple Pole 32 Amp. Make :-L&T/Havells/ Djb Approved , Mcb Triple Pole 63 Amp. Make:- L&T/Havells/ Djb Approved , Power Capacitors(Heavy Duty) 415V Unit Of 10 Kvar Make:- Havells /L&T/ Djb Approved , Shunt Power Capacitors(Heavy Duty) 415V Unit Of 5 Kvar Make :- Havells /L&T/ Djb Approved , Over Load Relay 24-32 annual periodical maintenance Make:-L&T/Siemens/ Djb Approved , Over Load Relay 15-22 annual periodical maintenance Make:- L&T/Siemens Djb Approved , Over Load Relay 6-9 annual periodical maintenance Make:- L&T/Siemens Djb Approved , Digital Amp. Meter Make Ae/L&T/ Djb Approved , Digital Volt Meter 0-500V .Make:- Ae/L&T/ Djb Approved , Motor Protection/Phase Failure Relay Make:- L&T/Siemens/ Djb Approved , Power Contactor 220V 3Phase 32 Amp. Make:- L&T/Siemens/ Djb Approved , Power Contactor 220V 3Phase 25 Amp. Make:-L&T/Siemens/Djb Approved , Power Contactor 220V 3Phase 16 Amp. Make:- L&T/Siemens/ Djb Approved , Star Delta Timer On Delay. Make:- L&T/Siemens/ Djb Approved , Indicating Lights Led Type Ryb & On/Off Make:-L&T/Havells/ Djb Approved , Supply Of On / Off Push Button. Make:- L&T/Havells/ Djb Approved , Providing And Fixing Of Suitable Size Ct 50/5, & 30/5. Make:- Ae /Advance/ Djb Approved , On Load Change Over Switch 200 Amp. 415V, Open Execution Type Make:- L&T/Havells/C&S/ Djb Approved , Supply Of Flexible Copper Cable 16 Sq Mm Single Core. Make: Grandlay/Havells/Djb Approved , Fitting Of The Above Components In Panel Enclosure With Terminal Blocks, Channels, Ferrules, Thimble, Support Insulator On Bus Bar, Required Hard Wares, Control Wiring In 1.5 Sq. Mm, 2.5 Sq.Mm & 4.00 Sq.Mm Wire Complete In All Respect. Job Including Making Of Star Delta Starter Provision In Panel. , Dismantling Of Old Panel, Structure, Damaged Components And Installation Of New Panel At Site By Making Foundation, Termination Of Cable Both Incoming And Outgoing Side, Including Cable Connections. This Includes Cartage ,Loading And Unloading By Crane Or Heavy Labour Etc. , Providing Of Energy Efficient Totally Enclosed Fan Cooled (Tefc) Squirrel Cage Induction Motor (Ie2), Enclosure Confirming To Protection Ip55, Horizontal Foot Mounted Induction Motor, Continuously Rated Suitable For Operation 415 +/- 10% V, 3 Phase 50Hz+/- 5% Ac Supply With Ambient 50 Degree C, Class F Insulation And Altitude Less Than 1000 M Above Msl And Confirming To Iec: 60034-1 & Is 12615:2018. Rating: 15 Hp/11Kw. Pole : 04 Pole Rpm: 1500 Make: Abb/Kec/Cg Power/Bharat Bijli/Djb Approved. , Dismantling Of Old Damaged Motor From Base Frame, Removing Of Electric Connection From Panel And Fixing Of New Motor At Base Frame With Nut Bolt And Washer , Providing Of Suitable Size Coupling Set, Coupling With Existing Pump, Connection Of Cable From Lt Panel To Starter. The Job Also Includes Cutting, Fitting And Welding Of Base Frame And Alignment Of Pump Set At Base Frame. , Providing And Fixing 25 Mm X 5 Mm G.I. Strip In 40 Mm Dia. G.I. Pipe From Earth Electrode Including Connection With G.I. Nut Bolt, Spring, Washer Excavation And Re-Filling Etc. As Required. Djb Sor E&M 2024-25 Item Code - 35.1.11 , Earthing With G.I. Earth Pipe 4.5 Meter Long, 40 Mm Dia Including Accessories, And Providingmasonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal/ Coke And Salt As Required. Djb Sor E&M 2024-25 Item Code - 35.1.2 , Testing & Commissioning Of Panel, As Per Required Parameters With Relevant Is. Testing Of The Panel Prior To Switching On As Follow :- I) 1. Continuity And Earth Testing Ii) 2. Meggaring Of All Equipments For Phase To Phase, Neutral To Body, Neutral To Earth And Phase To Earth. 3. Checking For All Tightness Of Nut And Bolts. 4. Alignments Of Doors Etc. 5. Interlocking Tests. 6. All Function Tests.

BOQ

Name of Work:- Replacement of very old and damaged LT Panel and allied works at Pkt-10B DDA Flat Jasola Vihar BPS in Okhla Constituency AC-54.
Sl. No. Item Description
1LT Distribution panel sheet steel enclosure made out of 2 mm CRCA sheet totally enclosed, powder coated free standing, floor mounted type, dust& vermin proof, outward opening, lockable doors having hidden hinges and a bolted back cover both using non-deteriorating neoprene rubber gaskets to provide IP-54 protection .The each part of the fabricated panel will be strictly subjected to seven tank treatment. The various components, assemblies and sub equipments of the panel will be as per standard given in relevant IS. The bus bar of the panel will be shaped out of high conductivity, electrolytic conductor and shall be liberal sized in aluminium. The control wiring of the panel will be done with PVC flexible copper wires of 1.5 mm cross section. Each wire will be terminating with a ferule crimped to the wire. The panel size must be of 1800MMX1800MMX450MM mounted on MS angle having 4 legs of 1 feet height.
2MCCB 125 Amp. 4 Pole 3phase High breaking capacity 50KA 50Hz, 430V with spreader & Handle Make : L&T/ Siemens/ Schneider/ Havells/ DJB approved make..
3MCCB 63 Amp. 4 Pole 3phase High breaking capacity 50KA 50Hz, 430V with spreader & Handle. Make: L&T/ Siemens/ Schneider/ Havells/ DJB approved make.
4MCCB 415V, 4 Pole, 3 phase 50KA 50Hz, 40 Amp with spreader & handle. Make : L&T/Siemens/Schneider/Havells/DJB approved make..
5MCB Single pole 6 Amp. Make:- L&T/Havells/Schneider/ DJB approved
6MCB Triple pole 32 Amp. Make :-L&T/Havells/ DJB approved
7MCB Triple pole 63 Amp. Make:- L&T/Havells/ DJB approved
8Power capacitors(Heavy Duty) 415V unit of 10 Kvar Make:- Havells /L&T/ DJB approved
9Shunt Power capacitors(Heavy Duty) 415V unit of 5 Kvar Make :- Havells /L&T/ DJB approved
10Over load relay 24-32 Amp Make:-L&T/Siemens/ DJB approved
11Over load relay 15-22 Amp Make:- L&T/Siemens DJB approved
12Over load relay 6-9 Amp Make:- L&T/Siemens DJB approved
13Digital Amp. Meter Make AE/L&T/ DJB approved
14Digital Volt Meter 0-500V .Make:- AE/L&T/ DJB approved
15Motor protection/Phase failure Relay Make:- L&T/Siemens/ DJB approved
16Power contactor 220V 3phase 32 Amp. Make:- L&T/Siemens/ DJB approved
17Power contactor 220V 3phase 25 Amp. Make:-L&T/Siemens/DJB approved
18Power contactor 220V 3phase 16 Amp. Make:- L&T/Siemens/ DJB approved
19Star delta timer on delay. make:- L&T/Siemens/ DJB approved
20Indicating lights LED type RYB & On/OFF Make:-L&T/Havells/ DJB approved
21Supply of ON / OFF Push Button. make:- L&T/Havells/ DJB approved
22Providing and fixing of suitable size CT 50/5, & 30/5. Make:- AE /Advance/ DJB approved
23On load change over switch 200 Amp. 415V, Open execution type Make:- L&T/Havells/C&S/ DJB approved
24Supply of flexible Copper cable 16 sq mm single core. Make: Grandlay/Havells/DJB approved
25Fitting of the above components in panel enclosure with terminal blocks, channels, ferrules, thimble, support insulator on bus bar, required hard wares, control wiring in 1.5 sq. mm, 2.5 sq.mm & 4.00 sq.mm wire complete in all respect. Job including making of star delta starter provision in panel.
26Dismantling of old panel, structure, damaged components and installation of new panel at site by making foundation, termination of cable both incoming and outgoing side, including cable connections. This includes cartage ,loading and unloading by crane or heavy labour etc.
27Providing of Energy efficient totally enclosed fan cooled (TEFC) Squirrel cage induction motor (IE2), enclosure confirming to Protection IP55, Horizontal foot mounted Induction motor, continuously rated suitable for operation 415 +/- 10% V, 3 Phase 50Hz+/- 5% AC supply with ambient 50 degree C, Class “F” insulation and altitude less than 1000 m above MSL and confirming to IEC: 60034-1 & IS 12615:2018.Rating: 15 HP/11KW. Pole : 04 PoleRPM: 1500 Make: ABB/KEC/CG Power/Bharat BIjli/DJB Approved.
28Dismantling of Old damaged Motor from base frame, removing of electric connection from panel and fixing of New Motor at base frame with nut bolt and washer , providing of suitable size coupling set, coupling with existing pump, connection of cable from LT Panel to Starter. The job also includes cutting, Fitting and welding of base frame and alignment of pump set at base frame.
29Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia. G.I. pipe from earth electrode including connection with G.I. nut bolt, spring, washer excavation and re-filling etc. as required. DJB SOR E&M 2024-25 item code – 35.1.11
30Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providingmasonry enclosure with cover plate havinglocking arrangement and watering pipe etc. with charcoal/ coke and salt as required. DJB SOR E&M 2024-25 item code – 35.1.2
31Testing & commissioning of panel, as per required parameters with relevant IS. Testing of the panel prior to switching on as follow :- i) 1. Continuity and earth testing ii) 2. Meggaring of all equipments for phase to phase, neutral to body, neutral to earth and phase to earth.3. Checking for all tightness of nut and bolts.4. Alignments of doors etc.5. Interlocking tests. 6. All function tests. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57079801
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 26-08-2026
Authority
Authority Name Delhi Jal Board
Work Description Tender for Replacement Of Very Old And Damaged Lt Panel And Allied Works At Pkt-10B Dda Flat Jasola Vihar Bps In Okhla Constituency Ac-54. , Lt Distribution Panel Sheet Steel Enclosure Made Out Of 2 Mm Crca Sheet Totally Enclosed, Powder Coated Free Standing, Floor Mounted Type, Dust& Vermin Proof, Outward Opening, Lockable Doors Having Hidden Hinges And A Bolted Back Cover Both Using Non-Deteriorating Neoprene Rubber Gaskets To Provide Ip-54 Protection .The Each Part Of The Fabricated Panel Will Be Strictly Subjected To Seven Tank Treatment. The Various Components, Assemblies And Sub Equipments Of The Panel Will Be As Per Standard Given In Relevant Is. The Bus Bar Of The Panel Will Be Shaped Out Of High Conductivity, Electrolytic Conductor And Shall Be Liberal Sized In Aluminium. The Control Wiring Of The Panel Will Be Done With Pvc Flexible Copper Wires Of 1.5 Mm Cross Section. Each Wire Will Be Terminating With A Ferule Crimped To The Wire. The Panel Size Must Be Of 1800Mmx1800mmx450mm Mounted On Ms Angle Having 4 Legs Of 1 Feet Height. , Mccb 125 Amp. 4 Pole 3Phase High Breaking Capacity 50Ka 50Hz, 430V With Spreader & Handle Make : L&T/ Siemens/ Schneider/ Havells/ Djb Approved Make.. , Mccb 63 Amp. 4 Pole 3Phase High Breaking Capacity 50Ka 50Hz, 430V With Spreader & Handle. Make: L&T/ Siemens/ Schneider/ Havells/ Djb Approved Make. , Mccb 415V, 4 Pole, 3 Phase 50Ka 50Hz, 40 annual periodical maintenance With Spreader & Handle. Make : L&T/Siemens/Schneider/Havells/Djb Approved Make.. , Mcb Single Pole 6 Amp. Make:- L&T/Havells/Schneider/ Djb Approved , Mcb Triple Pole 32 Amp. Make :-L&T/Havells/ Djb Approved , Mcb Triple Pole 63 Amp. Make:- L&T/Havells/ Djb Approved , Power Capacitors(Heavy Duty) 415V Unit Of 10 Kvar Make:- Havells /L&T/ Djb Approved , Shunt Power Capacitors(Heavy Duty) 415V Unit Of 5 Kvar Make :- Havells /L&T/ Djb Approved , Over Load Relay 24-32 annual periodical maintenance Make:-L&T/Siemens/ Djb Approved , Over Load Relay 15-22 annual periodical maintenance Make:- L&T/Siemens Djb Approved , Over Load Relay 6-9 annual periodical maintenance Make:- L&T/Siemens Djb Approved , Digital Amp. Meter Make Ae/L&T/ Djb Approved , Digital Volt Meter 0-500V .Make:- Ae/L&T/ Djb Approved , Motor Protection/Phase Failure Relay Make:- L&T/Siemens/ Djb Approved , Power Contactor 220V 3Phase 32 Amp. Make:- L&T/Siemens/ Djb Approved , Power Contactor 220V 3Phase 25 Amp. Make:-L&T/Siemens/Djb Approved , Power Contactor 220V 3Phase 16 Amp. Make:- L&T/Siemens/ Djb Approved , Star Delta Timer On Delay. Make:- L&T/Siemens/ Djb Approved , Indicating Lights Led Type Ryb & On/Off Make:-L&T/Havells/ Djb Approved , Supply Of On / Off Push Button. Make:- L&T/Havells/ Djb Approved , Providing And Fixing Of Suitable Size Ct 50/5, & 30/5. Make:- Ae /Advance/ Djb Approved , On Load Change Over Switch 200 Amp. 415V, Open Execution Type Make:- L&T/Havells/C&S/ Djb Approved , Supply Of Flexible Copper Cable 16 Sq Mm Single Core. Make: Grandlay/Havells/Djb Approved , Fitting Of The Above Components In Panel Enclosure With Terminal Blocks, Channels, Ferrules, Thimble, Support Insulator On Bus Bar, Required Hard Wares, Control Wiring In 1.5 Sq. Mm, 2.5 Sq.Mm & 4.00 Sq.Mm Wire Complete In All Respect. Job Including Making Of Star Delta Starter Provision In Panel. , Dismantling Of Old Panel, Structure, Damaged Components And Installation Of New Panel At Site By Making Foundation, Termination Of Cable Both Incoming And Outgoing Side, Including Cable Connections. This Includes Cartage ,Loading And Unloading By Crane Or Heavy Labour Etc. , Providing Of Energy Efficient Totally Enclosed Fan Cooled (Tefc) Squirrel Cage Induction Motor (Ie2), Enclosure Confirming To Protection Ip55, Horizontal Foot Mounted Induction Motor, Continuously Rated Suitable For Operation 415 +/- 10% V, 3 Phase 50Hz+/- 5% Ac Supply With Ambient 50 Degree C, Class F Insulation And Altitude Less Than 1000 M Above Msl And Confirming To Iec: 60034-1 & Is 12615:2018. Rating: 15 Hp/11Kw. Pole : 04 Pole Rpm: 1500 Make: Abb/Kec/Cg Power/Bharat Bijli/Djb Approved. , Dismantling Of Old Damaged Motor From Base Frame, Removing Of Electric Connection From Panel And Fixing Of New Motor At Base Frame With Nut Bolt And Washer , Providing Of Suitable Size Coupling Set, Coupling With Existing Pump, Connection Of Cable From Lt Panel To Starter. The Job Also Includes Cutting, Fitting And Welding Of Base Frame And Alignment Of Pump Set At Base Frame. , Providing And Fixing 25 Mm X 5 Mm G.I. Strip In 40 Mm Dia. G.I. Pipe From Earth Electrode Including Connection With G.I. Nut Bolt, Spring, Washer Excavation And Re-Filling Etc. As Required. Djb Sor E&M 2024-25 Item Code - 35.1.11 , Earthing With G.I. Earth Pipe 4.5 Meter Long, 40 Mm Dia Including Accessories, And Providingmasonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal/ Coke And Salt As Required. Djb Sor E&M 2024-25 Item Code - 35.1.2 , Testing & Commissioning Of Panel, As Per Required Parameters With Relevant Is. Testing Of The Panel Prior To Switching On As Follow :- I) 1. Continuity And Earth Testing Ii) 2. Meggaring Of All Equipments For Phase To Phase, Neutral To Body, Neutral To Earth And Phase To Earth. 3. Checking For All Tightness Of Nut And Bolts. 4. Alignments Of Doors Etc. 5. Interlocking Tests. 6. All Function Tests.
Basic Detail
Tender No NIT No. 16/EE(EM)M-11/(26-27)
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 19 Aug 2026
Submission Date 26 Aug 2026
Open Date 26 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 14900
Exemption Available
Document List
854dfd54-1e86-4e50-8d4a-87a9574cb0f4.html
BOQ_395892.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 26, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Aug 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
html

854dfd54-1e86-4e50-8d4a-87a9574cb0f4.html

xls

BOQ_395892.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders