Tender For Repair / Renovation Of Internal / External Electrification Works At Zro Office Giri Nagar In Kalkaji Constituency.
Tender Overview
Project Description
Tender for Repair / Renovation Of Internal / External Electrification Works At Zro Office Giri Nagar In Kalkaji Constituency. , Dismantling Of Old Defective / Burnt Batten Wiring, Unusable Ms Box, Db, Mcb, Wires, Ceiling Fan And Exhaust Fan Etc. Required At Site As Per Site Requirement. , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Group C. Sor Code No.1.10.3 , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire Sor Code No.1.14.2 , 2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire Sor Code No.1.14.3 , 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire Sor Code No.1.14.4 , Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5/6 A Modular Socket Outlet And 5/6 A Modular Switch, Connections Etc. As Required. Sor Code No.1.13 , Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5/6 & 15/16 A Modular Socket Outlet And 15/16 A Modular Switch, Connections Etc. As Required. Sor Code No.1.32 , Supplying And Fixing 5 A To 32 A Rating, 240/415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. (Single Pole) Sor Code No.2.10.1 , Earthing With G.I. Earth Pipe 4.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal/ Coke And Salt As Required. Sor Code No.5.2 , Supplying And Laying 6 Swg G.I. Wire At 0.50 Metre Below Ground Level For Conductor Earth Electrode, Including Connection/ Termination With Gi Thimble Etc. As Required. Sor Code No.5.7 , Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Sor Code No.1.25 , Supplying And Fixing Pvc Batten/ Angle Holder Including Connections Etc. As Required. Sor Code No.1.58 , Supplying And Fixing Call Bell/ Buzzer Suitable For Single Phase, 230 V, Complete As Required. Sor Code No.1.38 , Higher Wattage Decorative Ultra Slim Aluminum Led Lighting Fixture With High Lumen Output, Environmental Friendly, Energy Efficient Ready To Use Pack.36 W Led 6500 K Sor Code No.19.3.3 , New Generation Energy Saving And Environmental Friendly Long Life Led Street Light Made Up Of Pressure Die Cast Aluminum Housing With High Efficient Led As Lighting Source And Pc Cover Having Top Opening Separate Driver Compartment With Ip66 Protection And Impact Resistance Of Ik07. 70/72 W Led Sor Code No.19.10.6 , Supply Of 1200 Mm Sweep, Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current (Bldc) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value (Cmm/W) Minimum 6.85, Air Delivery Minimum 215 Cmm, 350 Rpm (Tolerance As Per Is : 374-2019), Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C (Max.), Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Complete As Required. Make :- ( Bajaj/ Crompton/ Usha/ Havells ). Sor Code No.20.1.2 , Supply Of 380 Mm Exhaust Fan Heavy Duty Make :- ( Bajaj / Khaitan / Crompton/ Usha ). Sor Code No.20.2.2 , Supply Of Wall Fan 400 Mm Make: ( Bajaj / Khaitan / Crompton/ Usha ). Sor Code No.20.4.1 , Installation, Testing And Commissioning Of Pre-Wired, Fluorescent Fitting / Compact Fluorescent Fitting Of All Types, Complete With All Accessories And Tube/Lamp Etc. Directly On Ceiling/ Wall, Including Connections With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable And Earthing Etc. As Required. Sor Code No.1.41 , Installation, Testing And Commissioning Of Ceiling Fan, Including Wiring The Down Rods Of Standard Length (Upto 30 Cm) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required. Sor Code No.1.44 , Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required. Upto 450 Mm Sweep. Sor Code No.1.50.1 , Providing And Fixing Of 32 Mm Dia X 2.00 Meter Long Gi Pipes (Medium Class) Bracket For Mounting Of Florescent/Hpmv/Hpsv Street Light Fitting On Wall/Pole Including Bending The Pipe To The Required Shape, 2 Nos. 40 Mm X 3 Mm Flat Iron Clamps With Nuts, Bolts And Washer Or Anchor Bolts/Fastnut Painting The Flat Iron With Primer And Finish Paint Etc. As Required. Sor Code No. (Dar 2025-13.34 , Supply Of Smc Junction Box Anti-Corrosive Water Resistant, Uv Protected, High Temp Resistant, Conforming To Ul 94, Erda Approved, Weatherable, And Suitable For All Kinds Of Climatic Conditions. Self-Colored Fire Retardant And High Di-Electric Strength Maintenance-Free With All Accessories. Make:- Sintex, Sumip, Aeron, Binani. , Providing Of 2 Core 16 Sq. Mm Armored Aluminum Conductor Xlpe Cable 1.1 Kv Confirming To Is 1554/1/88 With Latest Amendment. Make:- Havells, Gloster, Grandlay/ Djb Approved Make , Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Wall Surface As Required. Upto 35 Sq. Mm (Clamped With 1Mm Thick Saddle) Sor Code No.37.7.1 , Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. 2 X 16 Sq. Mm (22Mm). Sor Code No.39.1.3 , Supplying, Installation, Testing & Commissioning Of Following Capacity At Full Load (Unity Power Factor) On Line Uninterrupted Power Supply (Ups) System Suitable For Single Phase Input, Single Phase Output Ac Supply. The Ups Shall Include A Rectifier, Inverter, Battery Bank Suitable For 30 Minutes Back Up (Battery Vah Capacity Shall Not Be Less Than 1600 Vah Per Kva Of Ups Rating Per Hour Backup Time) On Full Load (Battery Shall Be Vrla, Smf In Abs Container) And Static Bypass Switch Along With Manual Bypass, Suitable Isolation Transformer For Additional Protection Against Neutral Faults Etc. The Ups Systems Shall Be Microprocessor Based Digital Control, Using Insulated Gate Bipolar Transistor (Igbt)S Both For The Rectifier & Inverter With Pwm (Pulse Width Modulation) Technology. The Quality Of Design, Manufacturing And Inspection Process Should Confirm To The Relevant Inter-National Standards Such As Iec/En/Vde. The Operating Efficiency Of The Ups Systems Shall Be 95% At 100% Non-Linear Loads. Current Total Harmonic Distortion(Ithd)/ Total Demand Distortion (Tdd) On The Input Grid Shall Be 5% At 100 %Load. (The Required Lc Filters Shall Be Included In Ups Cost), Extreme Power Factor Kit To Be Include To Limit The Input providing fixing To 0.99 And Output Power Factor Shall Be Unity (I.E. Kw Rating Of The Ups Shall Be Kva Rating X 1 ) However Ups Shall Be Suitable To Take Load At 0.7 Laging To 0.7 Leading Power Factor Loads. Ups Shall Be Suitable For Incoming Supply Ac Single Phase 160-270V 50 Hz And Delivering Output Ac Supply True Sine Wave Single Phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload Capacity Of 120% For 10 Mins And 150% For 1 Minute. Operating Temperature 0 To 40 °C, Relative Humidity 0-95% Non Condensing, Noise Level Less Than 60Db At 1 Meter Distance, Protection For Under Voltage, Over Voltage, Abnormal Output Voltage, Battery Over Charging, Output Over Current, Short Circuit, Battery Deep Discharge , 10 Kv Surge. Display For Watt/Va,Amp And Voltage Power Parameters Etc. Ups Shall Comply With Low Voltage Electromagnetic Compatibility (Emc) Achieved As Per En 6204, En6204 Part I And Part 2, It Shall Be A Voltage And Frequency Independent (Vfi) Type Ups (As Per Standard Iec 62040-1, 2 & 3) .The Ups Should Be With Igbt Based Inverter Technology, Communication Rs232/ Rs485/ Snmp Port Open Protocol For Bms Integration As Per Approved By Engineering In Charge. Required Battery Racks, Dc Breaker Of Suitable Rating And Interconnecting Copper Conductor Cable Of Suitable Size And Connectors And All Required Accessories Are Inclusive In The Construction The Ups Should Have Qr Code Which Should Contain Drawing, Test Report Oem Manual, Geo- Tag Of Manufacturing Location Etc As Per Sor Code No.26.1 10 Kva. As Per Sor Code No.5.1.4 , Supply, Installation, Testing And Commissioning Of 5 Star Rated Window Air Conditioner, 1.7 Ton Capacity, Conforming To The Latest Bee Star Labelling Requirements As Per Gazette Notification S.O. 2794(E) Dated 16.07.2024, Complete With Eco-Friendly Refrigerant Conforming To Is 16656 / Iso 817 Having Zero Ozone Depletion Potential (Odp), Copper Condenser And Evaporator Coils, Rotary Compressor, Suitable Voltage Stabilizer (If Required), Mounting Arrangement, Drain Pipe, Power Cable, All Accessories, Interconnections, And Complete In All Respects As Required At Site. , Supply, Installation, Testing And Commissioning Of 5 Star Rated Wall Mount Type Split Air Conditioner, 1.7 Ton Capacity, Conforming To The Latest Bee Star Labelling Requirements As Per Gazette Notification S.O. 2794(E) Dated 16.07.2024, Complete With Eco-Friendly Refrigerant Conforming To Is / Iso Having Zero Ozone Depletion Potential (Odp), Copper Condenser And Evaporator Coils, Rotary Compressor, Suitable Voltage Stabilizer (If Required), Mounting Arrangement, Drain Pipe, Power Cable, All Accessories, Interconnections, And Complete In All Respects As Required At Site , Testing And Commission Of Above Items.
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of old defective / burnt batten wiring, Unusable MS box, DB, MCB, wires, Ceiling Fan and Exhaust Fan etc. required at site as per site requirement. |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C. SOR Code No.1.10.3 |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire SOR Code No.1.14.2 |
| 4 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire SOR Code No.1.14.3 |
| 5 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire SOR Code No.1.14.4 |
| 6 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. SOR Code No.1.13 |
| 7 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. SOR Code No.1.32 |
| 8 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Single pole) SOR Code No.2.10.1 |
| 9 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. SOR Code No.5.2 |
| 10 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. SOR Code No.5.7 |
| 11 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. SOR Code No.1.25 |
| 12 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. SOR Code No.1.58 |
| 13 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. SOR Code No.1.38 |
| 14 | Higher wattage decorative ultra slim aluminum LED lighting fixture with high lumen output, environmental friendly, energy efficient ready to use pack.36 W LED 6500 K SOR Code No.19.3.3 |
| 15 | New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminum housing with high efficient LED as lighting source and PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07. 70/72 W LED SOR Code No.19.10.6 |
| 16 | Supply of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Make :- ( Bajaj/ Crompton/ Usha/ Havells ). SOR Code No.20.1.2 |
| 17 | Supply of 380 mm Exhaust fan heavy duty Make :- ( Bajaj / Khaitan / Crompton/ Usha ). SOR Code No.20.2.2 |
| 18 | Supply of Wall fan 400 mm Make: ( Bajaj / Khaitan / Crompton/ Usha ). SOR Code No.20.4.1 |
| 19 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. SOR Code No.1.41 |
| 20 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. SOR Code No.1.44 |
| 21 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep. SOR Code No.1.50.1 |
| 22 | Providing and fixing of 32 mm dia x 2.00 meter long GI pipes (Medium Class) bracket for mounting of florescent/HPMV/HPSV street light fitting on wall/pole including bending the pipe to the required shape, 2 Nos. 40 mm x 3 mm flat iron clamps with nuts, bolts and washer or anchor bolts/fastnut painting the flat iron with primer and finish paint etc. as required. SOR Code No. (DAR 2025-13.34 |
| 23 | Supply of SMC junction box anti-corrosive water resistant, UV protected, High temp resistant, Conforming to UL 94, ERDA Approved, Weatherable, and suitable for all kinds of climatic conditions. Self-colored Fire retardant and High di-electric strength maintenance-free with all accessories. Make:- Sintex, Sumip, Aeron, Binani. |
| 24 | Providing of 2 core 16 sq. mm armored aluminum conductor XLPE cable 1.1 KV confirming to IS 1554/1/88 with latest amendment. Make:- Havells, Gloster, Grandlay/ DJB approved make |
| 25 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle) SOR Code No.37.7.1 |
| 26 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 16 sq. mm (22mm). SOR Code No.39.1.3 |
| 27 | Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion(ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 °C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge. Display for watt/VA,Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) .The UPS should be with IGBT Based Inverter Technology, Communication RS232/ RS485/ SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accessories are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc as per SOR Code No.26.110 KVA. As per SOR Code No.5.1.4 |
| 28 | Supply, Installation, Testing and Commissioning of 5 Star Rated Window Air Conditioner, 1.7 Ton Capacity, conforming to the latest BEE Star Labelling requirements as per Gazette Notification S.O. 2794(E) dated 16.07.2024, complete with eco-friendly refrigerant conforming to IS 16656 / ISO 817 having Zero Ozone Depletion Potential (ODP), copper condenser and evaporator coils, rotary compressor, suitable voltage stabilizer (if required), mounting arrangement, drain pipe, power cable, all accessories, interconnections, and complete in all respects as required at site. |
| 29 | Supply, Installation, Testing and Commissioning of 5 Star Rated Wall Mount Type Split Air Conditioner, 1.7 Ton Capacity, conforming to the latest BEE Star Labelling requirements as per Gazette Notification S.O. 2794(E) dated 16.07.2024, complete with eco-friendly refrigerant conforming to IS / ISO having Zero Ozone Depletion Potential (ODP), copper condenser and evaporator coils, rotary compressor, suitable voltage stabilizer (if required), mounting arrangement, drain pipe, power cable, all accessories, interconnections, and complete in all respects as required at site |
| 30 | Testing and commission of above items. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender