Tender For Repairing And Maintenance Of Defective Addressable Fire Alarm Devices Of Ndcc Convention Center.
Tender Value
14.70 Lakhs
Estimated cost
Bid Submission
27 Aug 2026
7 days left
EMD
29405
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repairing And Maintenance Of Defective Addressable Fire Alarm Devices Of Ndcc Convention Center.
BOQ
| Sl. No. | Item Description |
| 1 | Replacement/Supply, Installation, Testing and Commissioning of Addressable Optical Smoke Detector (Model No FAP-425-O) including mounting base with LED etc. complete as required, Each Detector should have inbuilt isolator for maintaining operational availability of all elements in the loop, even in the event of a short circuit & Drift Compensation feature & Automatic addressing. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 Shall be EN54/ VDscertification. (Make Bosch Only) |
| 2 | Replacement/Supply, Installation, Testing and Commissioning of Addressable Thermal Heat Detector (Model No FAP-425-T) including mounting base with LED etc. complete as required, Each Detector should have inbuilt isolator for maintaining operational availability of all elements in the loop, even in the event of a short circuit & Drift Compensation feature & Automatic addressing. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 Shall be EN54/ VDscertification. (Make Bosch Only) |
| 3 | Replacement/Supply, Installation, Testing and Commissioning of addressable Stand alone Loop Powered Addressable Sounder Model No FNM-420-A-BS-RD with mullti programmable tones/ sound patterns. The sound pressure not less than 90 DB, Sounder and Strobe both should be programmed from the panel shall be VDS . (In case of separately powered sounders, cost of the power cable shall be inclusive in the cost of sounders itself and shall not be paid separately and power of sounders shall be fed from main Fire Alarm Panel only) (Make Bosch Only) |
| 4 | Replacement/Supply, Installation, Testing and Commissioning of addessable manual break glass unit (Double action) with inbuilt isolators as per NFPA 72 style 7 wiring requirements, with flexible network structures & necessary fixing arrangements with key complete as required. Shall be EN 54 / Vds/UL Certification etc as required. (Make Bosch Only) Model No. FMC-210-DM-G-R |
| 5 | Supply, installation, testing, and commissioning of Avenar 8000 Fire Alarm Panel Controller, including all accessories, integration components, and programming functions required for full operability. 7-inch full-color touch display with a resolution of 800 × 480 pixels, providing intuitive operation, clear visualization, and user-friendly navigation. Supports up to 32 detection loops, enabling integration of large-scale fire detection architectures. Customizable user interface, supporting tailored screen layouts, system menus, event displays, and operational workflows.Integrated networking capability, enabling connection to multiple panels, fire control networks, and distributed control systems. Provision of interfaces for Building Management Systems (BMS), ensuring real-time data exchange and supervisory control. All necessary wiring, mounting accessories, programming, software licenses, and configuration tools shall be provided. |
| 6 | Supply, installation, testing and commissioning of LSN 300 Loop Control Module for Microprocessor based intelligent addressable main fire alarm panel Central processing Panel, supporting not less than 126 devices (including detectors) and minimum 126 detectors per loop complete all as specified and as directed by the Fire Officer / Engineer-InCharge. (Make:- Bosch) |
| 7 | Supplying, installation, testing & commissioning of addressable beam detector with short circuit isolator (inbuilt or seperate) complete with emitter and receiver including connections with remote test features etc complete as required. |
| 8 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS/HFFR outer sheath complete as required. |
| 9 | Credit -old non functional fire detector 100/- perold non functional soundar 100/- perold non functional MCP 100/- per Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysAug 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender