Tender For Repairing & Maintenance Of Fire Check Door Installed In Various Ndmc Building I.E. Palika Kendra, Ndcc Phase -Ii, Convention Center.
Tender Value
34.35 Lakhs
Estimated cost
Bid Submission
27 Aug 2026
4 days left
EMD
68703
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repairing & Maintenance Of Fire Check Door Installed In Various Ndmc Building I.E. Palika Kendra, Ndcc Phase -Ii, Convention Center.
BOQ
| Sl. No. | Item Description |
| 1 | Supply and fixing of 2 hour fire rated Steel Fire Door Frame 100x57mm single rebated as per site and location complete with directions of Engineer-in-charge/ Fire Officer.a) The door frame shall be 2 hours 3 criteria rating (Stability, Integrity and thermal Insulation) fire door- fabricated and complying with requirements of CBRI Roorkee/Government Department and conforming to relevant BS: 476 Part 20 & 22 & IS: 3614 Part II.b) The frame shall be fabricated from 1.6 mm thick galvanized steel sheet conforming to IS:277 with a factory pre-punhced groove so as to accomodate Fire & smoke seal size 10 x 4mm Frames should be butt jointed and field assembeled with bolting sytem for proper strength. Frames shall be provided with holdfasts, fasteners etc. complete to the entire satisfaction and direction of Fire Officer/Engr-in-Charge.Note: The frame shoule be finished with Powder coating in desired shade. |
| 2 | Providing and Fixing 46 mm thick Steel fire check door shutter of 120 minutes fire rating for stability & Integrity & 20 minutes of insulation confirming to BS:476 Part 22 and IS: 3614 Part II fabricated with 2 nos. 1.2 mm thick galvanized sheet with infill of fire rated Mineral Wool insulation filler of 64 Kg./M3 bonded to both faces of sheet with lock seam joints at stile edges and internal reinforcement at top, bottam and stile edges for fire rating. The door frames are manufactured from 1.6mm thick galvanized steel sheet pressed form to single Rebate profile of size 100mm 57mm. The door frames and door shutters are finished with \\"H\\" primer plus powder coating etc. complete to the entire satisfaction and direction of Fire Officer/Engr-in-Charge.Note: The shutter shoule be finished with Powder coating in desired shade. |
| 3 | Supply and fixing of 6mm thick, 2 Hrs. Fire Rated clear glass size 200 x 300, which can also withstand thermal shock upto 800 degree centigrade shall be used as in vision panel and is to be fixed in between the glass beading by using ceramic fiber and fire rated acrylic sealant in accordance with BS : 476 Part 22, EN 1363/EN 1364 for stability and integrity etc complete to the entire satisfaction and direction of Fire Officer/Engr-in-Charge. |
| 4 | Providing and fixing of 2 hour fire rated Door Closers UL tested for fire doors, fire tested in accordance of EN 1634-3 and for mechanical test to EN 1154 for 50000 cycles and shall be tested with fire door for 2 Hours fire rating door weight upto 36 kg, to 80 Kg and door width from 701mm to 1000 mm) with double speed adjustment with necessary accessories and screws etc. complete to the entire satisfaction and direction of Fire Officer/Engr-in-Charge. |
| 5 | Supplying and Fixing of Stainless Steel Tower Bolt of 300 x 10 mm 2 hrs Fire rated on existing double leaf door shutters openable inside or outside etc. complete U.L. listed, CBRI tested complete to the entire satisfaction and direction of Fire Officer/Engr-in-Charge. |
| 6 | Providing and fixing stainless steel 304 Grade D - Type pull handle 2 hrs fire rated of size 300 mm long and 22 mm Dia including stainless, Caps, nuts and bolts etc. of required size complete to the entire satisfaction and direction of Fire Officer/Engr-in-Charge. |
| 7 | Providing and Fixing of 2hrs fire rated Mortice dead Lock of superior quality complete to the entire satisfaction and direction of Fire Officer/Engr-in-Charge. |
| 8 | Supply & application of 2 hour fire rated Fire Sealant in Joints between frame & wall and Filling upto 25mm in width as per manufacturer’s specification with backup rod, paper taping on both the faces to avoid spoiling of adjacent walls, as required and as per direction of Engineer-In-Charge.(Note : Above 25 mm in width, the measurement will consider 25 mm in width) |
| 9 | Replacement of Reinforced Rubber Lined (RRL) Fire Hose Type 3, ISI Marked conforming to IS:636, 15 mtr long 50 mm dia with ISl marked Stainless Steel couplingdia 63 mm with GI Binding etc. complete to the entire satisfaction of Fire Officer. |
| 10 | Condition for credit - old damged wooden/ glass dismental door 400/- per door with frame including handel, hinghes, glass, buffer, lock. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysAug 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer