Tender For Supply, Installation, Testing And Commissioning Of New Electrical Wiring At Section Office Within The Premises Of 160 Mld Salauli Wtp.
Tender Value
9.03 Lakhs
Estimated cost
Bid Submission
25 Aug 2026
1 days left
EMD
18067
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
goa → Goa
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supply, Installation, Testing And Commissioning Of New Electrical Wiring At Section Office Within The Premises Of 160 Mld Salauli Wtp.
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in PVC casing caping with modular switch modular plates suitable size modular surface box of specified Category and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc. as required.;(a) Group A -- with Cat C Modular Accessories |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in PVC casing caping with modular switch modular plates suitable size modular surface box of specified Category and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc. as required.;(b) Group B -- with Cat CModular Accessories |
| 3 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in PVC casing caping with modular switch modular plates suitable size modular surface box of specified Category and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc. as required.;(c) Group C -- with Cat C Modular Accessories |
| 4 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor single core cable in the independent PVC casing capping of appropriate size as required.;(a) 2 x 1.5 sq.mm + 1 x 1.5 sq.mm earthwire (20mm casing ) |
| 5 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor single core cable in the independent PVC casing capping of appropriate size as required.;(c) 2 x 4 sq.mm + 1 x 4 sq.mm earthwire (20mm casing ) |
| 6 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor single core cable in the independent PVC casing capping of appropriate size as required.;(j) 4 x 6 sq.mm + 2 x 6 sq.mm earthwire (32mm casing ) |
| 7 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor single core cable in the independent PVC casing capping of appropriate size as required.;(k) 4 x 10 sq.mm + 2 x 10 sq.mm earthwire (32mm casing ) |
| 8 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor single core cable in the independent PVC casing capping of appropriate size as required.;(l) 4 x 16 sq.mm + 2 x 16 sq.mm earthwire (40mm casing ) |
| 9 | Supplying and fixing of following sizes of PVC casing caping alongwith accessories on surface as required.;(c)32mm casing capping |
| 10 | Supplying and fixing following modular switch/ socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required;(h) 5/6 A switch Cat B |
| 11 | Supplying and fixing following modular switch/ socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required;(j) 15/16 A switch Cat B |
| 12 | Supplying and fixing following modular switch/ socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required;(k) 3 pin 5/6 A socket outlet Cat B |
| 13 | Supplying and fixing following modular switch/ socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required;(l) 6 pin 15/16 A socket outlet Cat B |
| 14 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required;(b) Cat B |
| 15 | Supplying and fixing modular blanking plate on the existing modular plate switch box excluding modular plate etc. as required;(b) Cat B |
| 16 | Supplying and fixing 3 pin 5 A ceiling rose on the existing junction box/ wooden block including connections etc as required. |
| 17 | Supplying and fixing brass batten/ angle holder including connections etc as required. |
| 18 | Supplying and fixing call bell/ buzzer suitable for single phase 230 V complete as required.;(a) Ding Dong Bell |
| 19 | Supplying and fixing call bell/ buzzer suitable for single phase 230 V complete as required.;(c) Electronic Door Bell Bird Chime |
| 20 | Supplying and fixing following size modular PVC box alongwith modular base and cover plate for modulator switches in recess etc. as required;(i) 3 Module Cat B |
| 21 | Supplying and fixing following size modular PVC box alongwith modular base and cover plate for modulator switches in recess etc. as required;(k) 6 Module Cat B |
| 22 | Supplying and fixing following size modular PVC box alongwith modular base and cover plate for modulator switches in recess etc. as required;(l) 8 Module Cat B |
| 23 | Supplying and fixing following size modular PVC box alongwith modular base and cover plate for modulator switches in recess etc. as required;(m) 12 Module Cat B |
| 24 | Supplying and fixing following size modular PVC box alongwith modular base and cover plate for modulator switches in recess etc. as required;(o) 18 Module ) Cat B |
| 25 | Supplying and fixing suitable size modular PVC box with modular plate and cover in front on surface or in recess including providing and fixing 2 no 6 pin 15/16 A modular socket outlet and 2 nos 15/ 16 A modular switch connection painting etc. as required. ( For workstations);(b) Cat B |
| 26 | Supplying and fixing suitable size modular PVC box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/ 6 A modular switch connection painting etc. as required.;(b) Cat B |
| 27 | Installation earthing testing and commissioning of pre-wired fluorescent fitting/ compact fluorescent fittings of all types complete with all accessories and tube etc. directly on ceiling / wall including connections with 1.5 sq .mm FRLS PVC insulated copper conductor single core cable and earthing etc. as required. |
| 28 | Installationearthing testing and commissioning of ceiling fan including wiring the down rod of standard length ( upto 30 cm) with 1.5 sq .mm FRFRLS PVC insulated copper conductor single core cable etc. as required. |
| 29 | Supplying and fixing following way TPN sheet steel double door Horizontal type MCB distribution board 415 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required ( but without MCB/RCCB/Isolator);(d) 8 way (8+24) double door Horizontal type Cat A |
| 30 | Supplying and fixing following way TPN sheet steel double door Horizontal type MCB distribution board 415 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required ( but without MCB/RCCB/Isolator);(g) 6 way (4+18) double door Horizontal type Cat B |
| 31 | Supplying and fixing 6 A to 32 A C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.;(f) SP Cat B |
| 32 | Supplying and fixing following rating four pole 415 V isolator in the existing MCB DB complete with connections testing and commissioning etc as required;(g) 63 A Cat B |
| 33 | Supplying and fixing following rating four pole 415 V isolator in the existing MCB DB complete with connections testing and commissioning etc as required;(i) 100 A Cat B |
| 34 | Supplying and fixing SP blanking plate in the existing MCB DB complete as required |
| 35 | Earthing with GI earth pipe 2 mts long 40 mm dia medium class with ISI mark of approved brands including accessories and providing masonry enclosure with CI/RCC cover having locking /Lifting arrangement and watering pipe etc. (but without charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size not less than 1.0x1.0x 2.0 mtrs(min) and disposal of excavated soil. b) Class B GI pipe 40mm diameter as per specifications. c) Charcoal/salt as per specs ( paid seperately). d) Refilling the pit of size not less than 1.0x1.0x 2.0 mtrs(min) with soft black soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe. g)watering arrangement(plumbing will be paid seperately).;(b) In rocky strata |
| 36 | Extra for using salt and charcoal for pipe earth electrode as required( 65 Kgs of Charcoal and 5 Kgs of Salt). |
| 37 | Providing and fixing 4 mm dia copper wire on surface or in recess for loop arthing along with existing surface/ recessed conduit/ submain wiring/ cable as required |
| 38 | Supply and erecting of 48 inch (1200mm sweep) ceiling fan double ball bearing type complete with all accessories.;(b) Cat B |
| 39 | Supply and erecting of 9 inch (225 mm sweep) exhaust fan with double ball bearings 1400 rpm complete with all accessories.;(a) Cat A |
| 40 | Supply and erecting meter box suitable for three phase energy meter and incoming SP/DP MCB fabricated out of 16 SWG sheet steel powder coated complete as required and conforming to the requirements of Goa Electricity Department. |
| 41 | Supply installation testing and commissioning of electronic type three phase energy meter (KWh) 4 wire ISI marked in polycarbonate or sgheet steel body ( base mounting type) with counter display/LCD display with ELT in Class 1.0 50 Hz 240 V. AC duly tested by MRT along with Test Certificates complete as required of following capacity of make L & T only.;(b) 10 to 40 A |
| 42 | Supply and erecting S type Mild Steel fan hook fabricated out of 12 mm round bar complete as required. |
| 43 | Supply and fixing PVC Square/Round block on wall/surface |
| 44 | Supply of 4 feet, LED Single Box type, powder coated CRCA body fitting with all accessories, suitable for 18/20/22W LED tube, including 1no. of LED tube having integral driver, complete as required of makes: Havells, model-Regal Batten, T8 upto 1X22w SSBSWH (tube - Photon Ultra, E2.0 121 3T8 SSTL 20w LED 865 SPC).//Crompton, model-Eco-1, IGP 161 LT8-16 (tube-Ultron, LT8-20-865(2).//Jaguar, model-LUNI 01x120xc, CW, 20w (tube-LTBL 01x020Xc Tube, Al-PC based, CW, 20w).//Bajaj, model-BLRB-DB 118 ( tube-BLRB 20w LED 6500k). or equivalent models of above makes only (superseding at the time of execution), as directed by the Engineer-in-charge. |
| 45 | Supply of 9/10 Watts LED Bulb of make Philips/Crompton/Bajaj |
| 46 | Supplying and drawing/fixing indoor type 0.5 sq.mm FR PVC insulated copper conductor unarmoured telephone cable ITD/DOT approved with GI saddles on wal or in the existing surface/recesed steel/PVC conduit having folowing pair(s) complete as required.;(b) 5 Pair |
| 47 | Supplying and drawing of Cat - 6 UTP 4 pair annealed tinned copper conductor PVC insulated PVC sheathed unarmoured data cable in existing surface/recessed steel/PVC conduit of appropriate size including connection etc. complete as required;(a) Cat 6 |
| 48 | Supplying installation and testing of suitable size modular GI box modular plate and cover complete with RJ-45 connector(modular LAN socket TX1000/ CAT6) including concealed metal box/surface GI/PVC Box modular plate punching identifying complete as required.;CAT B |
| 49 | Supplying installation and testing of suitable size modular GI box modular plate and cover complete with RJ-11 connector(modular telephone socket) including concealed metal box/surface GI/PVC Box modular plate punching identifying complete as required.;CAT B |
| 50 | Dismantling of old wiring, casing and caping, wall mounted wooden switch boards, tubelight frames, ceiling fans etc complete with stacking of serviceable items and disposal of unserviceable items. |
| 51 | Supply of 3 1/2 core armoured PVC/XLPE insulated PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) IS:7098(Part I) with latest amendments of following size.;3 1/2 Core 35 sq.mm |
| 52 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Inchargesand cushioning with screened sand bed of 20mm thick protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required.;(b) In rocky strata Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 25, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayAug 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender