Tender For maintenance and repair To Shendra - Jalna Water Supply Scheme At Khodegaon.. Repairs And Up-Gradation Of Cctv Camera System And miscellaneous Works At Wtp Khodegaon .
Tender Value
Ref. Documents
Estimated cost
Bid Submission
03 Sep 2026
2 days left
EMD
23600
Bank guarantee accepted
Document Fee
5900
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Aurangabad → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for maintenance and repair To Shendra - Jalna Water Supply Scheme At Khodegaon.. Repairs And Up-Gradation Of Cctv Camera System And miscellaneous Works At Wtp Khodegaon .
BOQ
| Sl. No. | Item Description |
| 1 | Supplying & laying rigid steel conduit 16 SWG 20mm dia. with necessary accessories in RCC work etc complete |
| 2 | Supplying and erecting HMS PVC conduit 25mm dia. with PVC accessories on wall/ceiling as per specification complete. |
| 3 | Supplying and erecting 20mm dia. corrugated flexible polypropylene conduit |
| 4 | Supplying & erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit |
| 5 | Supplying and erecting modular type switch 16A on provided plate and box with wiring connections etc complete. |
| 6 | Supplying and erecting modular type 3 pin 6/16A multi socket with safety shutter on provided plate etc complete. |
| 7 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module comple |
| 8 | Supplying, erecting & terminating 3 m HDMI cord low voltage grade minimum 4k compliant to be laid in |
| 9 | Supplying and installing FR PVC sheathed HDPE insulated copper cat-6 cable suitable for networking complete. |
| 10 | Supplying and erecting 6 fibers LSZH armoured multimode optical fiber cable with, core dia 50/125 µm |
| 11 | Supplying, fixing, and configuring 8-ports 1 GE un-managed gigabit PoE switch compliant with IEEE 80 |
| 12 | Supplying and fixing tool-less IO (ethernet) flush/surface type in provided modular box as per speci |
| 13 | Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x550x347 mm) as per specification no. |
| 14 | Supplying, fixing and configuring 10/100 BASE-TX to 100 BASE-FX (SC) Multimode Media converter for t |
| 15 | Supplying, erecting, testing & commissioning of 1 kVA capacity on line pure sine wave,PWM,IGBT bas |
| 16 | Supplying and erecting 12 V/65Ah SMF battery with battery terminal wire, duly charged complete with |
| 17 | Supplying, erecting, testing & commisioning plywood 12 mm thick fixed to wall or on provided panel b |
| 18 | Supplying, erecting, testing & commisioning self-locking arrangement with keys in duplicate, made of |
| 19 | Supplying, erecting, testing & commisioning metal work in CRCA sheet including Iron work for support |
| 20 | Providing, erecting, testing & commissioning of 2 Mega Pixel Full HD Vandal Resistance Vari Focal IR |
| 21 | Supplying & erecting 8 TB internal Surveillance HDD suitable for SATA Port of NVR interface transfe |
| 22 | Supplying, installing, testing & commissioning of 16/20 Ch. Network Video Recorder (NVR), suitable for 2 MP cameras only with HDMI/VGA outputs provided HDMI output of 4K resolution or VGA output with output up to 1920 × 1080. Support H.265 or higher, H.264, MJPEG, Incoming Bandwidth 160Mbps with minimum 2 SATA Hard Disks, ANR Technology, 2 SATA interfaces for 2 HDDs and capacity of each HDD up to 8TB, minimum 02 USB port,8TB, minimum 02 USB port, Alarm I/O 10 4/1, /100/1000 self-adaptive RJ-45 Mbps Ethernet interface, support multibrand network Cameras, ONVIF conformance, Multiple network monitoring: Web viewer. support protocol TCP/IP, DHCP, DNS, DDNS, NTP, SADP, SMTP, NFS, iSCSI, UPnP™, HTTPS. RoHS, UL, CE, FCC certified. duly erected in provided U Rack with wiring connections, tagging and programming etc. complete as per specifications CCTV-NVR |
| 23 | Supplying & erecting 55\\" professional LED display with 1920 *1080 ( Full HD) Display, suitable for 32/64 channel NVR and following features Brightness: minimum 500 Cd/m2 Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg. Response time: maximum 8 ms Inputs: HDMI, VGA, BNC,USB, Audio In, Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON |
| 24 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside DWC pipe for laying cabel or any other purpose etc complete. |
| 25 | Supplying, erecting, testing & Commissioning of Internet charges for all three location for 1 year period . |
| 26 | Repairing of existing faulty camera, cat 6 cable, SMPS, connectors, DVR etc completed Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysSep 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender