Heavy Industries and Public Enterprises Government Departments Closing in 8 days TDR #57079007

Tender For Erection Of 11 Kv Platform Mounted Sub-Station Facilities At Pump House-A In Vfj Estate

Issued by Government Departments · Jabalpur, Madhya Pradesh
Tender Value
31.97 Lakhs
Estimated cost
Bid Submission
02 Sep 2026
8 days left
EMD
64000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jabalpur → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Erection Of 11 Kv Platform Mounted Sub-Station Facilities At Pump House-A In Vfj Estate

BOQ

Name of Work:- Erection of 11 KV Platform Mounted Sub-Station Facilities at Pump House-A in VFJ Estate
Sl. No. Item Description
1Supplied & Installed of Transformer, step-down, 11/0.433 KVA complete, outdoor/indoor, copper wound capacity 500 KVA ,Level -3 (Make:Siemens/ABB/ Kirloskar/ BHEL/Bharat Bijli )
2M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 185 sq. mm ,3.5 core.(Make:Havells/Polycab/RR/finolex/KEI)
3M&L for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured,electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed,grade cross sectional area 185 sq. mm(Make:Havells/Polycab/RR/finolex/KEI)
4M&L for Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint.
5M&L for Air break (switch) insulator for 11000 volts, single pole for outdoor use Suitable for current rating of 200 amp.
6M&L for Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable for 11000 volts .
7M&L for Triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps, 11000 Volts.(Note:Horizontal Mounted AB Switch)
8M&L for Expulsion fuse single pole upto 25A, 6.6KV
9M&L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to185 sqmm.(Make:Rachem/Denson/3M)
10M&L for Anti-climbing device; spikes type fabricated out of M.S. bars (round,square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole
11M&L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size
12Cement concrete in surface channels and drains Type B2 1:2:4 (40 mm graded aggregate) .
13M&L for Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified ype 410 SP-64 (12.0 metres long)
14Tubes, 'medium grade' bore of tube 50mm galvanised, with all fitting and fixed complete to walls and ceilings or laidin floors
15M&L for sand filling under floor or in foundation including watering and consolidation
16Supplying and laying un- reinforced precast concrete cable cover, class LV, type 2,flat , size 300mm x 180mm x 40mm
17Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire
18Supply only Chain link MS galvanisd fencing, any size or type
19Excavating in trenches, in hard dense soil n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out.
20Excavating in trenches, in hard dense soil n exc 1.5 m wide and n exc 3.0 m in depth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out
21Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. in hard dense soil
22M&L for Stay assembly Diameter of stay rod 20mm complete with accessories as shown in electrical plate No. 1 ( loop type insulator, stay clamps, excavation and concrete.measured seperately )
23M&L for Loop type insulator, vitreous porcelain, white, brown or green, Large size, with overall dimensions 90mmX140mm, clearance of hole 25.5mm.
24Supply only for Galvanised stay strand (Grade 2), size 7/4.0mm
25M&L Earthing complete with Copper earth plate electrode 60×60cm ×3.15mm thick electrode and copper strip as earthing lead, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to copper strip 20×3mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion (Note: Earth Value for Neutral should be less than 01 Ohm and other less than 02 Ohm)
26M&L for Providing precast cement concrete in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces. Type B1 1:2:4 (20mm graded aggregate) set in cement mortar 1:4.
27S&F for GI pipes Heavy Class 25 mm Dia.
28M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6mm galvanised iron strip.
29Supply and fixing of Earthing cover plate 0.3.x0.3M with hinges and frame for earth pit chamber .
30S& F G I funnel with wire mesh with 25mm G I socket.
31Supply ,Instasllation & commissioning of Main Power Supply LT Panel having Adjustable type 4 pole MCCB incomer of capacity 400A with 400A Automatic Transfer switch Gear & outgoing 3 pole MCCB/MCB of suitable current rating with proper neutral link of mentioned rating and necessary requirement as per attached Annexure-D . Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57079007
AUTHORITY Government Departments
TENDER VALUE 31.97 Lakhs
LAST DATE 02-09-2026
Authority
Authority Name Vehicle Factory
Work Description Tender for Erection Of 11 Kv Platform Mounted Sub-Station Facilities At Pump House-A In Vfj Estate
Basic Detail
Tender No ND-2502/VFJ
Bidding Type Tender
Location
City Jabalpur
State Madhya Pradesh
Key Dates
Publish Date 18 Aug 2026
Submission Date 02 Sep 2026
Open Date 04 Sep 2026
Finance
Tender Value 31.97 Lakhs
Tender Fee Ref. Documents
EMD 64000
Exemption Not Available
Document List
6daad38c-394d-4393-b80f-7e5d04c20248.html
AnnexureASafetyInstructio_1.pdf
AnnexureBforMakeinIndiacertificate.pdf
AnnexureCforGSTrateandHSN_2.pdf
AnnexureDDescriptioncumTe_3.pdf
BOQ_335935.xls
TandCPartIIIStandardCondi_4.pdf
TandCPartIinstructiontotenderers.pdf
TandCPartIITechnicalSpecification.pdf
TandCPartIVSpecialConditi_5.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Sep 04, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

6daad38c-394d-4393-b80f-7e5d04c20248.html

pdf

AnnexureASafetyInstructio_1.pdf

pdf

AnnexureBforMakeinIndiacertificate.pdf

pdf

AnnexureCforGSTrateandHSN_2.pdf

pdf

AnnexureDDescriptioncumTe_3.pdf

xls

BOQ_335935.xls

pdf

TandCPartIIIStandardCondi_4.pdf

pdf

TandCPartIinstructiontotenderers.pdf

pdf

TandCPartIITechnicalSpecification.pdf

pdf

TandCPartIVSpecialConditi_5.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders