Tender For Repair To Sewage Line, Manholes, Septic Tanks, Soakage Wells Under Age B/R-Ii (W) Of Ge (W) Agra
Tender Value
48 Lakhs
Estimated cost
Bid Submission
08 Sep 2026
14 days left
EMD
96000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Agra → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair To Sewage Line, Manholes, Septic Tanks, Soakage Wells Under Age B/R-Ii (W) Of Ge (W) Agra
BOQ
| Sl. No. | Item Description |
| 1 | M&L for cleaning blockage manually or mechanically WHB,Kitchen,Bath Room, gully traps, nahani traps, floor traps to the entire satisfaction of Engineer-in-charge .Note:- (i) Printed complaint slip area wise as per format approved by Engineer-in-Charge shall be provided and maintained by contractor.(ii) Rate quoted above shall be deemed to incl the cost of T&P, equipment, saftey device etc alongwith sufficient labour to full fill the requirement to the entire satisfaction of Engineer-in-charge.(iii)The entire schedule of all the items executed upto Four storey |
| 2 | Cleaning/clearing of IWC/ EWC, including CI pipe / PVC pipe upto first manhole by roding, taking out all residue including waste and testing by pouring water after cleaning etc complete all as specified and directed by Engr-in-Charge. (Note: Cleaning of PVC/CI pipe from first floor / ground floor embedded in floor or fixed to wall included in this item) complete all as specified and directed. |
| 3 | Cleaning of under ground sewer lines of any type and size exc 75 mm dia and n exc 200dia incl manholes upto 3mtr depth and removing sludges upto 200mtr of any type of blockage of any kind of manhole or lines by means mechanical rodding with vibrations/drilling concept ie truck mounted machanished sewer jetting cum suction machine incl desludging descaling & clear the chocking where ever flushing the entire strectch with combind high pressure water jetting cum suction (Vacum) type machine suitably fabricated on HCV having facility of hydraulic application through. |
| 4 | Cleaning sewage sump wells, septic tanks, man holes,soak well of any depth and in any location etc by taking out complete sludge water & solids of any type by mechanically HCV mounted suction discharge machine having blow back facility with sludge tank of capacity not less than 6000 litres removing & disposing the entire retrieved materials to a distance not exceeding 1000mtr outside the perihery of defence land & covering the entire sludge & solids with local earth complete all as directed. |
| 5 | S&F in repair Grating doom 125 mm dia with waste hole of PTMT. (Minimum weight 40gms) including jointing with solvent /cement. |
| 6 | S&F in repair for PVC (SWR) Floor trap of 75 mm outlet plain with stainless steel grating including jointing with solvent /cement. |
| 7 | Excavation in trenches, in any kind of soil not exceeding 1.50 meter wide and not exceeding 1.50 meter in depth and getting out in soft/loose soil complete all as specified and directed by Engr -in-Charge. |
| 8 | All as per ser item No 7 hereinbefore but exceeding 1.5 meter and not exceeding 3 mtr depth. |
| 9 | Excavation over area not exceeding 1.50 meter in depth and getting out in soft/loose soil complete all as specified and directed by Engr -in-Charge. |
| 10 | All as per ser item No 9 hereinbefore but exceeding 1.5 meter and not exceeding 3 mtr depth. |
| 11 | Returning filling in including spreading levelling, watering and well remming in layers not exc 25cm thick complete all as specified and directed by Engr-in-Charge. (Surplus soil if any shall not be removed & left proud over the trench) |
| 12 | Removing excavated soil n.exc. 50m and deposited where directed at a level n.exc. 1.5m above the starting point. |
| 13 | PCC (1:4:8) type D-2 (using 40mm graded mechanically crushed stone aggregate) as in foundation of manhole complete all as specified and directed. |
| 14 | Brick work, with sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4 using old size bricks incl demolition of brick work built in cement mortar complete all as specified and directed. |
| 15 | All as per item No 14 above but using old bricks obtained from demolition. |
| 16 | Taking down cement or cement lime plaster of any discription on brick or stone walls/ ceilings etc, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 17 | M&L for 15 mm smart care ready mix repair plaster is specially designed ready to use cement-based plaster with high quality polymer additives and well graded sand and fillers which can be used for plastering (as per manufacturer instructions) over exterior wall surface complete all as specified and directed |
| 18 | M & L for Preparing newly plastered or un plastered surfaces of wall and applying two coat of cement base paint over a coat of primer complete all as specified and directed. |
| 19 | M&L cement concrete 1:2:4 , type B-1 using 20 mm graded mechanically crushed stone aggregate as in benching in manholes, coping, plinth courses, bands stopts etc including necessary form work complete all as specified foundation, mass concrete etc complete all as specified and directed. |
| 20 | Supply and laying Reinforced concrete pipes, class NP2,150mm bore laid and jointed complete with collars jointed in cement mortar 1:1 including testing and demolition of existing pipe complete all as specified and directed. |
| 21 | Plain cement concrete (1:4:8), type D-2, using 40 mm graded stone aggregates as in concrete bed to drain pipes of 150 mm bore laid to falls in trenches in any depth including packing under and haunching against the sides of pipes with concrete after the pipes are laid and tested complete all as specified and directed. |
| 22 | Supply and laying Reinforced concrete pipes, class NP2, 200 mm bore laid and jointed complete with collars jointed in cement mortar 1:1 including testing and demolition of existing pipe complete all as specified and directed. |
| 23 | Plain cement concrete (1:4:8), type D-2, using 40 mm graded stone aggregates as in concrete bed to drain pipe of 200 mm bore laid to falls in trenches in any depth including packing under and haunching against the sides of pipes with concrete after the pipes are laid and tested complete all as specified and directed. |
| 24 | Plain cement concrete (1:4:8), type D-2, using 40 mm graded stone aggregates as in concrete bed to drain pipe of 100 mm bore laid to falls in trenches in any depth including packing under and haunching against the sides of pipes with concrete after the pipes are laid and tested complete all as specified and directed. |
| 25 | M&L for Precast RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in slabs for covers of manholes including necessary form work and placing of manholes cover in position incl necessary demolition of existing RCC cover complete all as specified and directed by.Note: Reinforcement will be measured and paid seperately |
| 26 | M&L RCC Nominal mix 1:2:4 Type B1 (using 20mm graded aggregate) in slab supported on walls, beam, and columns in floors, roof and the like incl necessary demolition of existingall as specified and directed. |
| 27 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) rough finished flat surfaces of concrete . |
| 28 | Formwork to edges of concrete flats, treads breaks in floors, window cill, conctete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10 cm but n exc 20 cm wide |
| 29 | M&L TMT bars of 10mm dia and over, dia cut to length bent to shape required including cranking bending spirally, hooking ends and binding with mild steel wire not less than 0.9 mm dia(annealed) complete all as specified and directed by Engr-in-Charge. (Note - The payment shall be made only after placing of cover on manholes. |
| 30 | M&L Cutting into existing manholes for connecting internal dia of pipe 150mm in new drain, making good to pipe and rendering cutting out existing benching for channel (1/2 or 3/4section) in cement concrete 1 : 2 : 4 type B-1 by repairing benching as required complete all as specified and directed by Engr-in-Charge. |
| 31 | Cutting into existing manholes for connecting internal dia of pipe 200mm to 225mm in new drain, making good to pipe and rendering cutting out existing benching for channel (1/2 or 3/4section) in cement concrete 1 : 2 : 4 type B-1 by repairing benching as required complete all as specified and directed by Engr-in-Charge. |
| 32 | S & F in repairs Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern to squatt pattern closet including all joints and making good to the floor complete all as specified and directed |
| 33 | S & F in repairs 40mm for spout in sunken Polyethylene(PE-AL-PE) compositc pressure pipes includinall Crimp type internal sealing Plastic-Metal Composite fittings (such as elbows, tees, reducers, etc.) complete |
| 34 | Supply only integral water proofing compount (for mixing in cement mortar or concrete) complete all as specified and directed |
| 35 | S&F in repairs glazed earthen ware viterous china wash down water closet(pedestal pattern) white coloured with and including plastic water closed seat, white, closed pattern with recessed bottom, and cover and mild steel chromium plated hinging device etc complete all as directed. |
| 36 | S&F vitreous china rimless single piece WC of Size: 370x665x750 mm, Single Piece WC with PP Soft Seat cover, Hinges, Fixing Accessories, Accessories Set, and Cistern fittings, P trap-180mm complete all as specified and directed |
| 37 | S&F in repairs vitreous China squatting pan (Orissa pattern), white, of size 580x440mm white, along with integral foot rests including flush pipe, lime concrete bedding inlcuding taking out of old WC pan, old lime concrete bedding, unserviceable connections etc connecting up new and making good disturbe portion complete all as specified and directed. |
| 38 | S&F in repairs glazed earthen ware viterous china wash basin white coloured (flat back or angle back type), size 550x400 mm and including CI brackets, outlet of 32 mm bore HDPE outlet pipe with necessary fittings ,32 mm bore brass CP waste couplings and bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed etc complete all as directed. |
| 39 | Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) including complete all as specified and directed. |
| 40 | S&F non-skid coloured of approved shade ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed 15mm thick in CM 1:6 incl necessary demolition of existing tiles complete all as specified and directed. |
| 41 | M&L for glazed ceramic coloured tiles of size 600x300x7mm/ 450x300x6 to 7mm thick fixed over and including 10mm thick plaster in CM 1:4 on vertical surfaces such as skirting, dados and risers to steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete incl necessary demolition of existing tiles all as specified and drected |
| 42 | M&L 25 mm thick cement concrete 1:2:4 type B1 (20 mm graded aggregate) as in sub base complete all as specified and directed. |
| 43 | Cutting the roots of trees from the outlet of rainwater ,wastewater or sewage water pipe line in brick / stone wall made in cement mortar exc half and not exc one brick thick wall and making good the distrubed surface to arrest further growth to the roots with the cement sand mortar 1:3 or PCC 1:2:4 complete all as specified and directed. Note: Entire bldg cosidered as one Job |
| 44 | S&F in repars Plastic water closet seat, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed. |
| 45 | S&F in repair PVC (SWR) pipes 110mm dia single socketed in any length with rubber ring joints laid in trenches or in floors including dismantling etc complete all as specified and directed . |
| 46 | S&F in repair PVC (SWR) pipes 110mm dia single socketed in any length with rubber ring joints fixed on wall including dismantling etc complete all as specified and directed.Note: Fixing accessories ie profile braket, sloted channel, & U bolt will be measured and paid separately as supply only under item No 64, 65 & 67 of BOQ |
| 47 | S&F in repair PVC (SWR) pipes 75mm dia single socketed in any length with rubber ring joints laid in trenches or in floors including dismantling etc complete all as specified and directed . |
| 48 | S&F in repair PVC (SWR) pipes 75mm dia single socketed in any length with rubber ring joints fixed on wall including dismantling etc complete all as specified and directed . Note: Fixing accessories ie profile braket, sloted channel, & U bolt will be measured and paid separately as supply only under item No 64, 65 & 66 of BOQ |
| 49 | S&F in repair PVC (SWR) bends any radius 110mm dia complete all as speified and directed |
| 50 | S&F in repair PVC (SWR) bends any radius 110mm dia with access doors complete all as speified and directed. |
| 51 | S&F in repair PVC (SWR) bends any radius 75mm dia complete all as speified and directed |
| 52 | S&F in repair PVC (SWR) bends any radius 75mm dia with access doors complete all as speified and directed. |
| 53 | S&F in repair PVC(SWR) 'T' single (equal or unequal) 110 mm dia with access doors complete all as specified and directed |
| 54 | S&F in repair PVC(SWR) 'T' single (equal or unequal) 75 mm dia with access doors complete all as specified and directed |
| 55 | S&F in repairs in repairs 10 litres capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, flushing pipe and PVC connections 15mm size with PTMT nuts of length 450mm inlcuding taking out of old unserviceable connections etc, connecting up new and making good disturbe portion complete all as specified and directed. |
| 56 | S&F in repairs Vitreous China urinals, half stall type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; including fixing Brass chromium plated bottle traps 32mm bore for urinal with inlet and outlet screwed for pipe or connections including necessary packing, union fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. etc complete all as specified and directed. |
| 57 | S&F in repair CP jet Spray heavy duty with PVC connection complete all as specified and directed. |
| 58 | S&F in repair CP health faucet ABS body with wall hook and 1 mtr stainless steel braided rubber hose complete all as specified and directed. |
| 59 | S&F in repair Waste coupling of PTMT (half or full threaded) . (Minimum weight 32mm- 45gms/40mm-60 gms) of 32mm bore suitable for wash hand basin complete all as specified and directed. |
| 60 | S&F 32 mm dia PVC flexible waste pipe 800mm long etc. complete all as specified and directed. |
| 61 | Repair to leakage from junction of CP/PVC bend with EWC & cistern by providing M-Seal complete all as specified and directed. |
| 62 | Supply only plain profile Bracket (A3) 32mm wide X 3mm thick to maintain gap of 100mm from wall and fixed with SS304 Hex Flange Bolt and Fixing Nail Zn coated of thickness 6.5 mm and length 63 mm (2 1/2\\") for fixing PVC pipe 75mm/110mm dia has per HQ CEBZ drg no BTD 916, Sheet nos 1/4 completed all as specified as directed |
| 63 | Supply only ribbed low carbon steel continuous slotted C channel (B2) size 48mm x 3mm wall as per HQ CEBZ drg no BTD 916, Sheet nos 1/4 TO 2/4 completed all as specified as directed |
| 64 | Supply only U bolt rubber sleeve ,type C2 diameter 6 mm approx suitable PVC pipe of nominal 75mm diameter as per HQ CEBZ drg no BTD 916, Sheet nos 1/4 TO 2/4 completed all as specified as directed |
| 65 | Supply only U bolt rubber sleeve ,type C2 diameter 6 mm approx suitable PVC pipe of nominal 110mm diameter as per HQ CEBZ drg no BTD 916, Sheet nos 1/4 TO 2/4 completed all as specified as directed |
| 66 | M&L Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, alusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing holdpast and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 67 | M & L for applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surface over 10 cm width or girth, not otherwise described complete all as specified and directed. |
| 68 | Taking down existing sunken portion treatment by demolition of old concrete and carry out the sunken treatment as in following steps given below and procedure as per Appendix'A' of particular specifications.(a) S & F of drainage spout GI pipe 40mm dia bore light grade upto outside or outer wall ( Apprx 450mm to 600mm long).(b) M & L for PCC 1:1.5:3 type A-0 (using 12.50mm graded stone agg) 50mm thick laid in slope towards drainage out spout pipe mixed with waterproofing chemical as per manufacturer instructions for Khurra 150mmx150mm (min) at appropriate location for free flow (of leaked water if any) towards drainage spouts shall be provided integrally while laying PCC. Fixing of spout shall be done with same PCC as in this item.(c) M & L for 18mm thick cement plaster in CM 1:3 on verticalfaces mixed with water proofing chemical while concrete is green and proper curing and ponding test shall be done before laying dfrainage water supply pipes upto the entire satisfaction of Engineer-In-Charge.(d) Applying two coats of seal coat on vertical as well as horizontal surface.(e) Drainage and water supply pipe if required and test for leakage /sanitary pipes and shall be laid to slope and a clear gap underneath the pipes shall be made avbailable by providing suitable cement concrete block. |
| 69 | (f) M & L PCC 1:5:10 type E-2 using 40mm graded stone aggregate as reqd depth at site over and including 150mm thick 20mm single sized stone agg to provide a filter media.(g) M&L PCC 25mm thick 1:2:4 type B-0 using 12.5 mm graded stone aggregate for level course.(h) M&L for 7 to 8 mm thick non skid ceramic coloured joint less tiles (aquare/rectangur) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors etc laid jointing in neat cement slurry and pointed filled with epoxy chemical mixed with pigment to match with shade of tiles over and including 15mm thick screed bed in CM(1:6) complete all as specified and directed.Note : (i) Waterproofing treatment shall be undertaken alongwith laying of drainage pipe/sanitary pipes/drainage spout etc.(ii) The work shall be carried out as per the direction of Engineer-In-Charge.(iii) The sunken treatment work shall only be carried out after written approval of Engineer in charge for leakage/seapage of water/ sanitary pipes.(iv) Cost of drainage spout shall deemed to be included in the item however sanitary pipe, water ipe line if required shall be paid separately under respective items.(v) Laying of chemicl required for varios applications shall be as per manufacturer instructions.(vi) Plan area shall only be measured and paid. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 08, 2026
17:00 IST