Defence Statutory Bodies & Commissions/Committees Closing in 15 days TDR #57078943

Tender For Repair/Maint Of Geyser, Internal Wiring, Cold Weather Appliances, Cooling Appliances Including Connected Works At Chcc And College Of Nursing Area Of Age E/M (Hosp) Under Ge E/M Lucknow

Issued by Statutory Bodies & Commissions/Committees · Lucknow, Uttar Pradesh
Tender Value
40 Lakhs
Estimated cost
Bid Submission
08 Sep 2026
15 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Lucknow → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maint Of Geyser, Internal Wiring, Cold Weather Appliances, Cooling Appliances Including Connected Works At Chcc And College Of Nursing Area Of Age E/M (Hosp) Under Ge E/M Lucknow

BOQ

Name of Work:- REPAIR/MAINT OF GEYSER, INTERNAL WIRING, COLD WEATHER APPLIANCES, COOLING APPLIANCES INCLUDING CONNECTED WORKS AT CHCC AND COLLEGE OF NURSING AREA OF AGE E/M (HOSP) UNDER GE E/M LUCKNOW
Sl. No. Item Description
1Taking down water heaters / Geysers of any capacity for overhauling / serviceing / repairing by opening of base plate, descaling of water taknk, heating element, cleaning of entire geyser, checking & tighting of all internal electric connection, replacement of nut bolt etc, reassembling, refixing, re-installation of water heaters / Geysers to their original position, making all necessary water and electric connections and testing, complete as specified and as directed.Note :- (i) Labour for assembling of all old/ serviceable and new parts to make the geyser in serviceable condition shall include in this items. (ii) Spears parts renewed shall be measured and paid spearately as supply only.
2Supply only heating element 1.5 KW (ISI marked) suitable for geyser of 25 litres capacity, horizontal or vertical type any make complete as specified and as directed.
3Supply only heating element 2 KW (ISI marked) suitable for geyser of 50 litres capacity, horizontal or vertical type any make complete as specified and as directed.
4Supply only thermostat, minimum 300 mm long, suitable for any & type of geyser 25 / 50 litres capacity horizontal or vertical type complete as specified and as directed.
5Supply only indicating lamp LED type for geysers of any type make & capacity, complete as specified and as directed.
6M&L for preparation of old painted surfaces of geysers of 25 litres capacity of any make and applying one coat synthetic enamel paint of approved shade and rewriting of MES Nos as approved size of letter complete as specified and as directed.
7S&F in repair PVC connection 15 mm dia with 2 Nos brass coupling, nuts from geyser inlet / outlet, 45 cm length suitable for 15 mm bore GI pipe complete as specified and as directed.
8S&F in repair 15 mm size stop cock cast copper alloy, chromium plated, fancy type with capstan head, screwed down, screwed for iron pipes complete as specified and as directed.
9S&F in repair 15 mm size bib taps cast copper alloy, chromium plated, fancy type with capstan head, screwed down, screwed for iron pipes complete as specified and as directed.
10S&F in repair 15 mm size non-return valve, gun metal, suitable for geyser of any capacity, complete as specified and as directed.
11S&F in repair 15 mm size pressure releasing valve ISI marked as per sample fixed to geyser,complete as specified and as directed.
12S&F in repair stainess steel tank verticle type suitable for 25 litre Geyser, complete as specified and as directed.
13S & F in repair stainless steel tank verticle type suitable for 50 ltr Geyser, complete as specified and as directed.
14Taking down detiorated, out lived, rusted and unsv storage type water heater & Supply and fix new storage type water heater 25 ltrs capacity, 5 Star rated, vertical mounting type, made out of CRCA outer body, copper storage tank, heating element, thermostat, thermal cut out, glass wool insulation etc. including making necessary electrical connections with suitable size copper multistranded cable and connecting to water supply, complete as specified and as directed.
15Taking down ceiling fans/ exhaust fans / wall mounting fans of any size after disconnecting from ceiling rose / connector and carriying out cleaning, servicing / oiling and greasing of fan by using appropriate grade of oil / grease, checking & tighting all electric connection and replacing defective parts such as bush bearing , split pin, rubber bush, capacitor etc and refixing the same after and making workable by providing 3 core 1.5 Sqmm size copper conductor flexible cable PVC insulated & PVC sheathed complete as specified and as directed. Note :- Spare parts / component / Painting & rewinding where required will be measured & paid seperatly under respective item of the BOQ.
16M&L for rewinding of ceiling fans/exhaust fans/wall mounting fans of any size, AC 230 volts single phase with super enamelled copper winding wire of appropriate / existing gauge / size including packing, insulating material soldering varnishing, assembling and testing including transportation charges to and back from contractor's workshop to office store, complete as specified and as directed.
17S&F in repair bearing of ceiling fans/exhaust fans/wall mounting fans of any size any sweep to suit for different makes of fans of approved quality including necessary greasing,complete as specified and as directed.
18S&F in repair bushes gun metal suitable for ceiling fans/exhaust fans/wall mounting fans of any size any sweep, complete as specified and as directed.
19Supply and fix in replacement for ceiling fan down rods of 15mm bore GI pipe medium grade of 1Mtr/1.5Mtr/2Mtr length as required including welding and fixing with clamps and nut bolts etc at any height, complete all as specified and as directed.
20M&L for preparation of old painted surface of ceiling fans of any size any sweep and applying one coat of synthetic enamelled white with spray machine and rerewriting of MES Nos. as approved size of letter all as specified and directed. Please Enable Macros to View BoQ information
21M&L for preparation of old painted surface of ceiling fans of any size any sweep and applying one coat of synthetic enamelled white with spray machine and rerewriting of MES Nos. as approved size of letter all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57078943
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40 Lakhs
LAST DATE 08-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maint Of Geyser, Internal Wiring, Cold Weather Appliances, Cooling Appliances Including Connected Works At Chcc And College Of Nursing Area Of Age E/M (Hosp) Under Ge E/M Lucknow
Basic Detail
Tender No GE/EM/LKO/HOSP/T-18 OF 2026-27
Bidding Type Tender
Location
City Lucknow
State Uttar Pradesh
Key Dates
Publish Date 18 Aug 2026
Submission Date 08 Sep 2026
Open Date 10 Sep 2026
Finance
Tender Value 40 Lakhs
Tender Fee 500
EMD 80000
Exemption Available
Document List
120d46d9-c0a3-4a53-80e8-f187c8b26684.html
BOQ_879653.xls
Tender.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Sep 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
html

120d46d9-c0a3-4a53-80e8-f187c8b26684.html

xls

BOQ_879653.xls

pdf

Tender.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders