Tender For Repair /Maint Of Lt Oh/Ug Distribution System And Allied Works For Asd Kasubegu Area Under Ge (East) Ferozepur Cantt
Tender Value
33 Lakhs
Estimated cost
Bid Submission
08 Sep 2026
16 days left
EMD
66000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Firozepur → Punjab
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair /Maint Of Lt Oh/Ug Distribution System And Allied Works For Asd Kasubegu Area Under Ge (East) Ferozepur Cantt
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches n. exc 1.5mm wide and n.exc 1.5m deep for foundation of poles/stays/cable etc and getting out in soft /loose soil complete all as specified and directed by Engr-in-Charge. |
| 2 | Excavation in trenches exc 1.5mm wide and exc 1.5m deep for foundation of poles/stays/cable etc and getting out in soft /loose soil complete all as specified and directed by Engr-in-Charge. |
| 3 | Returning , filling in and incl spreading, levelling watering and well ramming in layers each n.exc 25cm thick in soft/loose soils complete all as specified and directed. |
| 4 | Removing surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point etc complete all as specified and directed. |
| 5 | M& L for Sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engr in charge. |
| 6 | Supply and laying well burnt, sub class 'B' brick old size for cable protection, complete all as specified and directed |
| 7 | M&L for cement concreted (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation of poles filling and mass concreting, complete all as specified and directed |
| 8 | M&L for cement concreted (1:3:6) type C-2 using 40 mm graded crushed stone aggregate in foundation of pole/ stay assembly/feeder pillar box/LT panel,etc, incl necessary form work and fair finsh to exposed surfaces without using extra cement etc, complete all as specified and directed |
| 9 | M&L Cement concreted (1:2:4) type B-1 using 20 mm graded stone aggregate as in foundation of electric poles/struts/ etc including necessary form work, fair finished surfaces without using extra cement, complete all as specified and directed |
| 10 | Dismantling & taking out old damaged PCC/Steel pole of any size and removing from site of work complete all as specified and directed. |
| 11 | Dismantling & taking out old damaged stay assembly complete with stay wire, loop type insulator,worntout clamps etc of any size and removing from site of work complete all as specified and directed. |
| 12 | Dismantling and taking down old wornt out ACSR conductor of any type and size complete all as specified and directed. |
| 13 | Dismantling & taking down old wornt out MS clamps/cross arms/channels complete with nuts & bolts etc complete all as specified and directed. |
| 14 | Dismantling and taking down old U/S insulators of any type and size complete all as specified and directed. |
| 15 | M&L Cross arms bracings, supported clamps and back plates, fabricated from structual steel sections, drilling holes for bolts, in any shape or size as indicated or directed and including necessary welding bending cold or hot inclusive of nuts, bolts, washers and two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces, complete all as specified and directed |
| 16 | Supply and fixing LT Pre-stressed concrete pole 9.0 metres long of cross section 102 mm x 172 mm at top and 102 mm x 279 mm at bottom class 10 complying with requirement of IS 1678-1978 incl painting of poles with two coats of synthetic enamel paint/over a coat of primer in black and white strips upto 1.5 mtr height from top of PCC as directed (PCC and earth work shall be measured and paid separately). complete all as specified and directed |
| 17 | Supplying and fixing stay assembly comprising of galvanised stay bow 40 cm long, 14 mm dia complete with 20 mm dia stay rod of 215 cm long with threaded ends and GI nut, two numbers thimbles, MS clamps made out of 40 x 6mm flat iron including nuts, bolts & washers, 300 x 300 x 6 mm stay plate , including painting of exposed MS work with two coat of aluminium paint over a coat of red oxide primer complete all as specified and as shown in electrial plate No 1 of SSR Part-I. Note: Necessary earth work , loop type insulator and stay strand shall be measured and paid separately under appropriate item of schedule/BOQ complete all as specified and directed |
| 18 | S & F in replacement of galvanised stay strand 7/4 mm size, complete all as specified and directed |
| 19 | M&L Aluminium conductor, steel reinforced (ACSR) of different sizes incl jointing and stritching for over head lines on LT poles including binding, jumpers, line taps etc complete all as specified and directed |
| 20 | Supply and Fixing in Repair of loop type insulator, porcelain, vitreous white brown of green of size 90mm x 140 mm and clearance of hole 25.5 mm complete all as specified and directed |
| 21 | Supply and Fixing in Repair of pin type, porcelain, viterous, white brown or green insulator including mild steel spindle & nut, two galvanised iron washers, one galvanised iron nuts 100 mm height , 65 mm dia for 1100 volts complete all as specified and directed |
| 22 | Supply and Fixing in Repair of shackle type porcelain viterous white brown or green insulator for working pressure 1100 V of 90 mm dia and 75 mm height etc incl galvanised mild steel straps made out of flat iron 31 mm incl 12 mm dia bolts, nuts, washers etc complete all as specified and directed |
| 23 | Stritching only of loosened existing ACSR conductor (Per Span consisting of any number and size of wire) any size, by opening the binding wire from insulator and re-fixining after streching with proper sag incl strenghtening of ACSR conductor and re-binding the same on insulators and binding complete all as directed by EIC. NOTE :- The unit rate includes attending the complaints of snapping of conductors as and when occured and as intimated. |
| 24 | S&F in replacement LT line poly proplain composite phase separators moulded type suitable for horizontal/ vertical 4 lines LT overhead lines complete all as specified and directed by Engr in Charge. |
| 25 | M&L for Pruning of tree branches of any size /dia from LT/HT overhead line up to a minimum clearance of 2.5 mtr from over head conductor incl T &P and transportation for disposal complete all as specified and directed by Engr in Charge. |
| 26 | M/L for Clearing of bushes/small plants upto root level around and surroundings areas E/M installations (i.e.Two Pole/ Four structures, outdoor-substation yards, pump house & E/M installations etc) including surface dressing n.exc 15 cm deep and removing debris to a distance n.exc 50m, complete all as specified and directed |
| 27 | M&L for painting of LT Panel complete with two coats of synthetic Enamel paints over a coat of red oxide and other necessary fabrication work like replacement of hinges ,locking Knobs, bending and welding work required for hinges etc as per required at site complete all as Specified and directed by Engr -in- ChargeNote :- The cost of item rate includes removal of old unservicable MCCBs of any type and capacity.New MCCBs, Voltmeter, Ammeter and Aluminium bus bar will be measured and paid separately under relevent item of BOQ. |
| 28 | M&L Painting of old LT PCC pole upto 1.5 mtr height from PCC, of synthetic enamel paint with black and white strips and including wiriting pole No all as specified and directed by Engr-in-Charge. |
| 29 | Dismantling and taking down old UNSV LT UG cable of any type and size complete all as specified and directed. |
| 30 | Supplying, laying and connecting XLPE insulated and sheathed armoured 1100 volts grade heavy duty electric cable with multistranded aluminium conductor laid in trenches/duct through pipe, in floor on poles in and including aluminium thimble or aluminium line tape of size 25 sq mm 4 core nominal cross section area complete all as specified and directed.Make - Polycab, Finolex and KEI. |
| 31 | All as per item No 30 here-in-before but size 35 sq mm 3.5 core, complete all as specified and directed. |
| 32 | All as per item No 30 here-in-before but size 50 sq mm 3.5 core, complete all as specified and directed. |
| 33 | All as per item No 30 here-in-before but size 70 sq mm 3.5 core, complete all as specified and directed |
| 34 | All as per item No 30 here-in-before but size 95 sq mm 3.5 core, complete all as specified and directed. |
| 35 | All as per item No 30 here-in-before but size 120 sq mm 3.5 core, complete all as specified and directed. |
| 36 | All as per item No 30 here-in-before but size 185 sq mm 3.5 core, complete all as specified and directed. |
| 37 | S&F in Repair of MCCB of capacity 400 Amps, Thermal Adjustable and fixed magnetic Type 4 pole, 415volt, 50Hz, rupturing capacity 36 KA (minimum) or higher, AC, 50 C/S, fixed in repairs, complete all as specified & directed. Make - ABB, C&S and SCHNEIDER, L&T. |
| 38 | S&F in Repair of MCCB of capacity 250 Amps, Thermal Adjustable and Fixed Magnetic Type 4 pole, 415volt, 50Hz, rupturing capacity 36 KA (minimum) or higher, AC, 50 C/S, fixed in repairs, complete all as specified & directed. Make - ABB, C&S and SCHNEIDER,L&T. |
| 39 | S&F in Repair of MCCB of capacity 200 Amps, Thermal Adjustable and fixed magnetic Type 4 pole, 415volt, 50Hz, rupturing capacity 36 KA (minimum) or higher, AC, 50 C/S, fixed in repairs, complete all as specified & directed. Make - ABB, C&S and SCHNEIDER, L& T. |
| 40 | S&F in Repair of MCCB of capacity 160 Amps, Thermal Adjustable and fixed magnetic Type 4 pole, 415volt, 50Hz, rupturing capacity 36 KA (minimum) or higher, AC, 50 C/S, fixed in repairs, complete all as specified & directed. Make - ABB, C&S and SCHNEIDER, L&T. |
| 41 | S&F in Repair of MCCB of capacity 100 Amps, Thermal Adjustable and Fixed Magnetic Type 4 pole, 415volt, 50Hz, rupturing capacity 25 KA (minimum) or higher, AC, 50 C/S, fixed in repairs, complete all as specified & directed. Make - ABB, C&S and SCHNEIDER, L&T. |
| 42 | Supply and laying GI pipe \\"light grade \\" for cable protection including taking out old/broken/rusty all as specified of size 80 mm bore, complete all as specified and directed |
| 43 | All as per item No 42 here-in-before but size 40 mm bore, complete all as specified and directed |
| 44 | Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated with aluminium solid conductor served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended, one twin core cable flat or circular of size 10 sq mm, complete all as specified and directed.Make - Polycab, Finolex and KEI. |
| 45 | All as per item No 44 above but size 16 sq mm, complete all as specified and directed. |
| 46 | S&F in repair of Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (Preferably in vertical position) earth pit not less than 2.25 metre below normal ground level with top edge of the earth plate not less 1.5 metre (BGL) connected to galvanized iron earth strip 32 x6 mm by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 50 mm bore “light grade” galvanized iron protection pipe for earth strip 32 x6 mm upto 5m length, charcoal, common salt, complete all as shown in EP No 1 of SSR 2009 Part-I, connected to test point complete, all as specified and testing on completion, complete all as specified and directed. |
| 47 | S&F in repair of Earthing complete, all as shown on electrical plate No 3 of MES schedule part-I , as specified including the following :-(i) Galvanised steel earth plate of size 60cmsx60cmsx6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.50 metre below normal ground level. (ii) Earth plate surrounded by and packed with char-coal and common salt in alternative layers (n.exc 15cms each layer). (iii) 4 mm dia (8 SWG) G.I earth wire from earth plate to main switch board including necessary GI bolts, nuts check nuts, washers, thimbles etc. (iv) 15 mm bore light grade, GI pipe for protection to earth-wire. (v) 20mm bore, medium grade, GI pipe for watering including GI funnel and wire mesh. Pipe shall be provided vertically upto top level of earth pit and then taken horizontally to the earth pit. (vi) 50mm thick pre-cast cover of cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate,Chamber in PCC(1:3:6), type-C2(to be constructed 1 m away from edge of earth pit) and MS angle iron 50x50x6mm frame including two coats of painting over a coat of red oxide to exposed steel surfaces. (vii) Excavation in soft/loose soil, returning filling & removal of surplus soil to a distance upto 50 metre as directed including testing etc all as specified. |
| 48 | Supply, installation, testing and commissioning in replacement of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, suitable for AC, 3 phase 4 wire, 50 cycles, 415 Volts, Front & Rear openable double door with locking arrangement. The panel board shall be made of 3.15 thick CRCA/MS sheet duly powder coated with pure polyester based paint on both externally and internally. The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm , thimbles including cable entry glands, all as directed. Panel Make-dvepl/tricolite/adlice/Milestone ,Base frame of the panel shall be made of angle iron of size 50 x 50 x 6 mm embedded in PCC (1:3:6) type C-2 using 40 mm stone aggregate of upto 1/2 mtr height below GL & 1/2 mtr for above GL.(i) Panel having common aluminium bus bar of capacity 500 Amp TPN each and suitable capacity TPN bus bar for outgoing MCCB's,including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable size. |
| 49 | (ii) Incoming:-(a) MCCB Adjustable type thermal released based with overload short circuit release suitable size and capacity, 250 Amp 4 Pole ICU = ICS = 36 KA with overload variation 40-100% - 01 No .(Incoming) Make-L&T/Schneider/Siemens/Indoasian.(iii) Outgoing:-(a) MCCB Adjustable type thermal released based suitable size and capacity, 125 Amp 4 Pole ICU = ICS = 25 KA with overload variation 40-100% - 03 Nos.(outgoing) Make-LK/Schneider/Siemens(b) All as per (a) above but MCCB of Capacity 63 Amps, 4 Pole 25 KA -01 Nos .(outgoing) Make-LK/Schneider/Siemens (iv) Volt Meter 0 - 500 Volts digital type square shape flush mounted with selector switch - 1 Nos(v) Ammeter 0 - 400 Amps digital type square shape 96mm flush mounted with selector switch and CT's 400/5 A - 1 Nos.(vi) Indicator lamp RYB :01 Set. with CT Coil complete. |
| 50 | Supply, installation, testing and commissioning in replacement of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, suitable for AC, 3 phase 4 wire, 50 cycles, 415 Volts, Front & Rear openable double door with locking arrangement. The panel board shall be made of 3.15 thick CRCA/MS sheet duly powder coated with pure polyester based paint on both externally and internally. Panel Make- dvepl/tricolite/adlice/Milestone, The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm , thimbles including cable entry glands, all as directed. Base frame of the panel shall be made of angle iron of size 50 x 50 x 6 mm embedded in PCC (1:3:6) type C-2 using 40 mm stone aggregate of upto 1/2 mtr height below GL & 1/2 mtr for above GL. (i) Panel having common aluminium bus bar of capacity 1000 Amp TPN each and suitable capacity TPN bus bar for outgoing MCCB's,including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable size. |
| 51 | (ii) Incoming:-(a) ACB 4 Pole, 415 V, Microprocessor release type (Manual Draw out type) of capacity 630 Amps.(Incoming) Make-L&T/Schneider/Siemens/Indoasian(iii) Outgoing:-(a) MCCB Adjustable type thermal released based type suitable size and capacity,400 Amp 4 Pole ICU = ICS = 36 KA with overload variation 40-100% - 01 Nos.(outgoing) Make-LK/Schneider/Siemens(b) All as per (a) above but MCCB of Capacity 125 Amps, 4 Pole 36 KA -04 Nos.(outgoing) Make-LK/Schneider/Siemens (iv) Volt Meter 0 - 500 Volts digital type square shape flush mounted with selector switch - 1 Nos(v) Ammeter 0 - 630 Amps digital type square shape 96mm flush mounted with selector switch and CT's 630/5 A - 1 Nos.(vi) Indicator lamp RYB :01 Set. with CT Coil complete. |
| 52 | Material & labour for boring hole under the road/payment/ hard standing upto 100 mm Bore Pipe not less than one metre below ground level complete all as specified and directed.. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysAug 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender