Tender For Repair/ Maintenance And Cleaning Of Sewage Lines, Manholes, Septic Tanks & Sokage, Well/ Pits And Connected Work At Alg And S&S Unit Under Ge (East) Ferozepur Cantt
Tender Value
46 Lakhs
Estimated cost
Bid Submission
08 Sep 2026
16 days left
EMD
92000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Firozepur → Punjab
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Maintenance And Cleaning Of Sewage Lines, Manholes, Septic Tanks & Sokage, Well/ Pits And Connected Work At Alg And S&S Unit Under Ge (East) Ferozepur Cantt
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exc. 1.5 mtr wide and not exc. 1.5 mtr depth for cesspits, manholes etc. and getting out soft/loose soil even in foul position, complete all as specified and as direcetd. |
| 2 | Excavation in trenches n. exc. 1.5 mtr wide and exc. 1.5 mtr but n.exc. 3.00 mtr depth for cesspits, manholes etc. and getting out soft/loose soil even in foul position complete all as specified and as direcetd. |
| 3 | Demolition of Cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed |
| 4 | M&L for PCC (1:4:8), type C2 (40 mm graded aggregate ) in foundation filling of manholes etc and mass concrete, complete all as specified and as direcetd. |
| 5 | M&L for Cement concrete 1:3:6 type C-1 as in surface channels and drains in manhole inside area etc, complete all as specified and as direcetd. |
| 6 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, mounds, mitred/stopped end etc.as in manhole pipe line portion only, complete all as specified and as direcetd. |
| 7 | Demolition and breaking of drain pipe (SGSW/PVC/RCC etc) set in cement mortar of internal dia 100 mm, complete all as specified and as direcetd. |
| 8 | S&F 100m dia soil glazed stone ware (SWG) drain pipes laid in trenches and jointed, complete all as specified and as direcetd. |
| 9 | M&L for cement concrete 1:3:6 type C-2 in concrete bed to 100mm dia drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in complete all as specified and directed. |
| 10 | Demolition and breaking of drain pipe (SGSW/PVC/RCC etc) set in cement mortar of internal dia 150 mm, complete all as specified and as direcetd. |
| 11 | S&F 150m dia soil glazed stone ware (SWG) drain pipes laid in trenches and jointed, complete all as specified and as direcetd. |
| 12 | M&L for cement concrete 1:3:6 type C-2 in concrete bed to 150mm dia drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in complete all as specified and directed. |
| 13 | Demolition and breaking of drain pipe (SGSW/PVC/RCC etc) set in cement mortar of internal dia 200 mm, complete all as specified and as direcetd. |
| 14 | S&F 200m dia soil glazed stone ware (SWG) drain pipes laid in trenches and jointed, complete all as specified and as direcetd. |
| 15 | M&L for cement concrete 1:3:6 type C-2 in concrete bed to 200mm dia drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in complete all as specified and directed. |
| 16 | Supply and fixing 110 mm bore PVC (SWR) pipes single socketed in any length laid in trenches or in floors and walls complete all as specified and as directed. |
| 17 | Supply and fixing 110 mm bore PVC (SWR) bends with access door any radius complate all as specified and as directed. |
| 18 | S&F PVC(SWR) 'T' single (equal or unequal) 110 mm dia with access doors complete all as specified and directed |
| 19 | Returning,filling in, spreading, levelling, watering and well ramming in layers not exc 25cm thick each in soft/loose soil, complete all as specified and directed. |
| 20 | Removing excavated material to a distance n.exc 50 mtr and depositing where directed at a level not exc 1.50 metre above the starting point, complete all as specified and as direcetd. |
| 21 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) (in Man holes) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 22 | M&L for RCC (1:2:4), type B1 using 20 mm graded stone aggregate in precast cement concrete cover slab for manhole and similar article with plain face, set in cement mortar 1:4 including form work complete all as specified and directed. |
| 23 | M&L for RCC , (1:1.5 :3) type B1 (20 mm graded aggregate) as in slab supported on walls, beams and columns in roofs etc. complete all as directed by Engr-in-Charge. |
| 24 | Formwork to soffit of suspended slabs such as roof slabs floor slabs, landings and similar works not exc 200 mm thick (Horizontal or sloping).complete all as directed by Engg-in charge. |
| 25 | Formwork to edges of concrete flats, treads, breaks in floors,window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide. complete all as directed by Engg-in charge. |
| 26 | S&F deformed or twisted TMT bars 10 mm dia and over, cut to length bent to shape required including cranking binding with MS wire (annealed) not less than 0.9 mm dia complete all as specified and as directed. |
| 27 | S&F deformed or twisted TMT bars 6 to 8mm dia, cut to length bent to shape required including cranking binding with MS wire (annealed) not less than 0.9 mm dia complete all as specified and as directed. |
| 28 | Dismantling of brick work built in cement mortar, seperation, cleaning and stacking of serviceable bricks for reuse and removal of debris, rubbish to a distance n. exc 50m, complete all as specified and as direcetd. |
| 29 | Material and labour for brick work with sub-class 'B' bricks straight or curved on plan exceeding 6 metres mean radius built in cement mortar 1:4 complete all as specified and directed. |
| 30 | All as per srl item No 29 above but except bricks(Old serviceable dismantalled bricks obtained from srl item no.28 shall be reused after cleaning of bricks), complete all as specified and as direcetd. |
| 31 | Providing cement concrete type C1 1:3:6 (20 mm graded aggregate) as in copings to brick wall, manholes, septictanks, sokage well etc and all other similar works including necessary form work complete all as specified and directed. |
| 32 | Taking down cement plaster in any surfaces complete all as specified and directed |
| 33 | M&L for 15 mm thick rendering in cement mortar 1:4 inside and outside wall of manhole of brick work/ concrete surface complete all as specified & as direcetd. |
| 34 | M&L for 15 mm thick rendering in cement mortar 1:3 inside and outside wall of septic tank, soakage well etc of brick work/ concrete surface with water proofing compound @3% by weight of cement complete all as specified & as direcetd.Note: WPC shall be measured and paid separately) |
| 35 | Supply only integral waterproofing compound complete all as specified and directed. |
| 36 | M&L for Cutting into existing manholes for connecting new drain making good for 150mm/200mm/300mm bore of pipes & rendering cutting out existing benching and forming branch (1/2 round or ¾ section) channel in PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate surface finished even and smooth and reforming benching in reqd, complete all as specified and as direcetd. Please Enable Macros to View BoQ information |
| 37 | M&L for Cutting into existing manholes for connecting new drain making good for 150mm/200mm/300mm bore of pipes & rendering cutting out existing benching and forming branch (1/2 round or ¾ section) channel in PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate surface finished even and smooth and reforming benching in reqd, complete all as specified and as direcetd. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysSep 15, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender