Housing Urban and Rular Development Government Departments Closing in 11 days TDR #57078749

Tender For Lighting Protection , Single Phase Protection From Wbsedcl Line Including Bypass Line Arrangement Work At (I) Haludkanali Bjrcy Girls Hostel , Jl No-102, Plot No- 232/391, Mouja- Haludkanali, Block- Rani Bandh Under Bcw & Td , Bankura. ( I

Issued by Government Departments · Bankura, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
03 Sep 2026
11 days left
EMD
81806
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bankura → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Lighting Protection , Single Phase Protection From Wbsedcl Line Including Bypass Line Arrangement Work At (I) Haludkanali Bjrcy Girls Hostel , Jl No-102, Plot No- 232/391, Mouja- Haludkanali, Block- Rani Bandh Under Bcw & Td , Bankura. ( Ii) Bibarda Bjrcy Girls Hostel , Jl No- 178 , Plot No. 413/512 Mouja- Bibarda, Block- Taldangra Under Bcw& Tw, Bankura (Iii) Ajodhya, Mouja- Ajodhya, Jl No- 10, Plot No-1595/1775, Block- Bishnupur Under Bcw& Td, Bankura ( Iv) Bagdiha Bjrcy Hostel C Us, Jl No- 129, Plot No- 156, Mouja- Bagdiha, Block - Indpur Under Bcw& Td , Bankura ( V) Kusumtikri Bjrcy Girls Hostel , Jl No- 178, Plot No- 413/ 512 Mouja- Kusumtikri, Block- Sarenga, Under Bcw& Td, Bankura ( Vi) Krishnapur - Goaldanga Bjrcy Hostel Camus , Jl No. 42. Plot No. 78/626 , Mouja- Krishnapur, Block- Sarenga, Under Bcw& Td , Bankura (Vii) Niveditacentral Hostel For Sc Girls Nutaanchati, Bankura ( Viii)Sabrakone Bjrcy Girls Hostel C Us , Jl No-130, Plot No- 352, Mouza - Amdangra, Block- Taldangra, Under Bcw& Td, Bankura.

BOQ

Name of Work:- Lighting protection , Single phase protection from WBSEDCL line including bypass line arrangement work at (I) Haludkanali BJRCY Girls Hostel , JL No-102, Plot no- 232/391, Mouja- HALUDKANALI, Block- Rani bandh under BCW & td , Bankura. ( II) Bibarda bjrcy Girls Hostel , JL NO- 178 , Plot no. 413/512 Mouja- Bibarda, Block- Taldangra under BCW& TW, Bankura (iii) Ajodhya, Mouja- AJODHYA, jl no- 10, plot no-1595/1775, Block- Bishnupur under BCW& TD, Bankura ( IV) Bagdiha BJRCY Hostel c us, JL NO- 129, Plot no- 156, Mouja- Bagdiha, Block - Indpur under BCW& TD , Bankura ( v) Kusumtikri BJRCY Girls Hostel , JL No- 178, Plot no- 413/ 512 Mouja- Kusumtikri, Block- Sarenga, under BCW& TD, Bankura ( vi) Krishnapur - Goaldanga BJRCY Hostel Camus , JL NO. 42. Plot no. 78/626 , Mouja- Krishnapur, Block- Sarenga, under BCW& TD , Bankura (VII) NiveditaCentral Hostel for SC Girls Nutaanchati, Bankura ( VIII)Sabrakone bjrcy girls Hostel C us , JL NO-130, Plot no- 352, Mouza - Amdangra, Block- Taldangra, under BCW& TD, Bankura.
Sl. No. Item Description
1Supplying and fixing 415V, TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. 63 Amp (Make:- LK(L&T)/ Siemens/ABB)
2Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. 2 WAY (Make:- LK(L&T)/ Siemens/ABB)
3Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.
420 Amp DP Isolator (Make: LK(L&T)/ ABB/ Legrand ) [ 5 KVA SOLAR ]
516 Amp DP Isolator ( Make:- LK(L&T)/ ABB/ Legrand ) [ 3.5 KVA SOLAR ]
6Supplying and fixing double-door (2+10 Way) SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Make: Legrand/LK(L&T)/ABB) and the DB Comprises of following instrument:- i) Supply and fixing of 250 V 20 amp DP MCB (Make: Legrand/ L&T/ABB )--- 02 Nos. ii) Supply and fixing of Automatic Change over switch (ACS) with current limiter 30A/20A(Make: LK(L&T) Cat no. AUCL01030012/ABB/Legrand) ----- 01 Nos. iii) Supply and fixing of Red LED Indicating lamp. (Make:-Legrand/ABB/LK(L&T) Cat no. AUIL01GRE00----1 Nos. iv) Supply and fixing of BLUE LED Indicating Lamp. (Make:-Legrand/ABB/LK(L&T) Cat no. AUIL01BLU00----01 Nos. v) Supply and fixing of BLUE LED Indicating Lamp. (Make:-Legrand/ABB/LK(L&T) Cat no. AUIL01YEL00----02 Nos. including necessary interconnection with 1.5/2.5/4.0/6.0 sq.mm PVC insulated copper wire, as required, complete with copper socketing/lugs and all necessary accessories, as per direction of E.I.C.
7Supplying and fixing double-door (2+10 Way) SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Make: Legrand/LK(L&T)/ABB) and the DB Comprises of following instrument:- i) Supply and fixing of 250 V 16 amp DP MCB (Make: Legrand/ LK(L&T)/ABB )---02 Nos. ii) Supply and fixing of Automatic Change over switch with current limiter 30A/12A (Make:ABB/ Legrand/LK(L& T) Cat no. AUCL01030012-----01 Nos. iii) Supply and fixing of Red LED Indicating lamp. (Make:-Legrand/ABB/LK(L&T) Cat no. AUIL01GRE00---- 01 Nos. iv) Supply and fixing of BLUE LED Indicating Lamp. (Make:-Legrand/ABB/LK(L&T) Cat no. AUIL01BLU00----01 Nos. V) Supply and fixing of BLUE LED Indicating Lamp. (Make:-Legrand/ABB/LK(L&T) Cat no. AUIL01YEL00----02 Nos. including necessary interconnection with 1.5/2.5/4.0/6.0 sq.mm PVC insulated copper wire, as required, complete with copper socketing/lugs and all necessary accessories, as per direction of E.I.C.
8Supplying and fixing double-door (2+4 way) SPN MCB distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Make: Legrand/ L&T/ABB)i) Supply & installation of SPD 50 Ka 3P + N 4 module . ( Make: LK(L&T) Cat no. AUSP123PN50 or equivalent of LEgrand/ABB) ------01 Nos. ( For protection of WBSEDCL power)including necessary interconnection with 1.5/2.5/4.0/6.010/16 Sq.mm PVC insulated copper wire, as required, complete with copper socketing/lugs and all necessary accessories, as per direction of E.I.C.
9Supply of plug-in spare cartridge/module for Surge Protection Device (SPD), suitable for AUSP121PN50/AUSP123PN50, (Make: Legrand/ABB/LK(L&T) Cat. No. AUSC121PN50), complete as required and as per manufacturer's specification.
10Supplying and fixing double-door (2+14 Way) SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Make: Legrand/LK(L&T)/ABB) and the DB Comprises of following instrument:- (i) Supplying and fixing 415 V MCB of Breaking capacity 10kA & C characteristics on din rail with necessary connection 63 A FP ( L&t / Legrand/ Siemens ) (ii) Supply & installation of VMR/ single phase protection device. (Make: Legrand/ABB/LK(L&T)---- 01 Nos. (iii) Supply and installation of 63A, 3NO, 3-Module Modular Contactor, suitable for 415V AC, ( Make: L&T (Lauritz Knudsen), Cat. No. AUMC3006303/Legrand/ABB)---- 01 Nos.(iii) Supplying and fixing 415 V Change over (MCB module) of on din rail and necessary connection 415V 63 AMP FP (Make: LK(L&T) Cat no. AUC00406300 /ABB/Legrand)- 01 Nos. iv) Supply and fixing of Red LED Indicating lamp. (Make:-Legrand/ABB/LK(L&T) Cat no. AUIL01GRE00---- 01 Nos. V) Supply and fixing of BLUE LED Indicating Lamp. (Make:-Legrand/ABB/LK(L&T) Cat no. AUIL01BLU00----01 Nos. iv) Supply and fixing of BLUE LED Indicating Lamp. (Make:-Legrand/ABB/LK(L&T) Cat no. AUIL01YEL00----02 Nos. , including necessary interconnection with 1.5/2.5/4.0/6.010/16 sq.mm PVC insulated copper wire, as required, complete with copper socketing/lugs and all necessary accessories, as per direction of E.I.C.
11Supplying and Drawing 1.1 KV single core stranded 'FR'PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required
122X84/0.3 (6 Sq.mm ) + 1X56/0.3 (4 Sq.mm ) as ECC
134X80/0.4 (10 Sq.mm ) + 2X84 /0.3 (6 Sq.mm ) as ECC
144X126/0.4 (16 Sq.mm ) + 2X80 /0.4 (10 Sq.mm ) as ECC
15Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
164 sqmm
176 sqmm
1810 sqmm
1916 sqmm
20Supply & delivery of ceiling fan 250 volt 1200 mm 380 RPM 75 WATT, 230 M3/min AC ceiling fan without regulator P2 capacitor, 1 star, with safety wire. ( Make: USHA Striker or Striker plus /Crompton-HS/Orient Electric- New Breeze) Colour white or Brown.
21Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
22Engraving the deptt. number with 10 mm lettering on the body of fan upto 10 letters incl. hifen, stroke or stop.
23Painting upto 10 letters of the engraved number with approved black /red paint as required.
24Supply and delivery of LED Tube Light Fitting, suitable for harsh environmental conditions, with sustained lighting performance, S4 version, 4000K, Make: Signify (Philips), Cat. No. BN100 C LED20 S-6500 PSU L120 GR S4 / SURYA/ BENLO)
25Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener.
26Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc.
27Supply and delivery of high-performance, low-wattage LED Street Light fitting, having luminous efficacy of minimum 120 lm/W, with high-power LED light source, IP66 ingress protection, PDC housing, impact resistance IK08 and UV-stabilized polycarbonate cover, complete with suitable LED driver. (Make: Signify (Philips) Cat No.BRP033 LED100 SLR GR PSU SPD / Surya/ Benlo)
28Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: 1) By ISI-Medium GI pipe.
29Excavation of soil for installation of Earth Electrode and filling & ramming. For Morrum Soil.
30Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
31Supply and installation of fabricated M.S. angle battery rack, made of 40 mm × 40 mm × 6 mm M.S. angle, suitable for accommodating 10 Nos. inverter tubular battery sets, each weighing approximately 250 kg, including necessary welding, cutting, fabrication, fixing/anchoring, and painting of the existing structure with suitable anti-corrosive primer and two coats of approved enamel paint, complete in all respects as per design, site condition and direction of E.I.C. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57078749
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 03-09-2026
Authority
Authority Name Public Works Department
Work Description Tender for Lighting Protection , Single Phase Protection From Wbsedcl Line Including Bypass Line Arrangement Work At (I) Haludkanali Bjrcy Girls Hostel , Jl No-102, Plot No- 232/391, Mouja- Haludkanali, Block- Rani Bandh Under Bcw & Td , Bankura. ( Ii) Bibarda Bjrcy Girls Hostel , Jl No- 178 , Plot No. 413/512 Mouja- Bibarda, Block- Taldangra Under Bcw& Tw, Bankura (Iii) Ajodhya, Mouja- Ajodhya, Jl No- 10, Plot No-1595/1775, Block- Bishnupur Under Bcw& Td, Bankura ( Iv) Bagdiha Bjrcy Hostel C Us, Jl No- 129, Plot No- 156, Mouja- Bagdiha, Block - Indpur Under Bcw& Td , Bankura ( V) Kusumtikri Bjrcy Girls Hostel , Jl No- 178, Plot No- 413/ 512 Mouja- Kusumtikri, Block- Sarenga, Under Bcw& Td, Bankura ( Vi) Krishnapur - Goaldanga Bjrcy Hostel Camus , Jl No. 42. Plot No. 78/626 , Mouja- Krishnapur, Block- Sarenga, Under Bcw& Td , Bankura (Vii) Niveditacentral Hostel For Sc Girls Nutaanchati, Bankura ( Viii)Sabrakone Bjrcy Girls Hostel C Us , Jl No-130, Plot No- 352, Mouza - Amdangra, Block- Taldangra, Under Bcw& Td, Bankura.
Basic Detail
Tender No WBPWD/SE/SWEC/NIQ26/2026-27
Bidding Type Tender
Location
City Bankura
State West Bengal
Key Dates
Publish Date 18 Aug 2026
Submission Date 03 Sep 2026
Open Date 07 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 81806
Exemption Not Available
Document List
257b2976-a637-4cd0-b4aa-f90db4607e92.html
BOQ_5090979.xls
Tendernotice_1 (25).pdf
Tendernotice_2 (3).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Sep 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
html

257b2976-a637-4cd0-b4aa-f90db4607e92.html

xls

BOQ_5090979.xls

pdf

Tendernotice_1 (25).pdf

pdf

Tendernotice_2 (3).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders