Tender For Repair, Replacement And Renovation Of Electrical Installation Work At Basement Area And Other Allied Works At Madhusudan Mancha, Dhakuria.

Issued by Government Departments · Kolkata, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
01 Sep 2026
8 days left
EMD
13257
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair, Replacement And Renovation Of Electrical Installation Work At Basement Area And Other Allied Works At Madhusudan Mancha, Dhakuria.

BOQ

Name of Work:- Repair, replacement and renovation of Electrical Installation work at basement area and other allied works at Madhusudan Mancha, Dhakuria.
Sl. No. Item Description
1Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment
24 way [Make-Legrand/L&T/Siemens as approved by E.I.C]
3Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.
42+12 Way Enclosure [Make-Legrand/Siemens/L&T as approved by E.I.C]
5Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. (Make: Legrand/Siemens/L&T as approved by E.I.C.)
663Amp FP Isolator
740 Amp DP Isolator
8Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. (Make: Legrand/Siemens/L&T as approved by E.I.C.)
96-32 Amps SP MCB
1063 Amps TP MCB
11Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Havells/Finolex/RR Kabel/Gloster/Polycab) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Legrand: Myrius/Arterior /ROMA Urban as approved by E.I.C) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish.
12Average run 8 mtr
13Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire ((Finolex/RR Kabel/Havells/Polycab/Gloster)) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Legrand: Myrius/Arterior /ROMA Urban as approved by E.I.C) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works.
14a) On Board
15Cutting Channel of size (43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 25 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika)and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles
1625 mm dia 3 mm thick polythene pipe without earth continuity wire.
17Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] of following sizes on wall, ceiling with saddles and other accessories as required and mending good damages to building works
18a) 20 mm size
19b) 25 mm size
20Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex/RR Kabel / Havells / Polycab/Gloster) of the following sizes in the 19mm/25mm prelaid polythene pipe/PVC rigid conduit as per GS.
21i) 3 x 22/0.3 (1.5 sqmm)
22ii) 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) as ECC
23iii) 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC
24iv) 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC
25Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
26a)1.5 sq mm
27b) 2.5 sq mm
28c) 4 sqmm
29d) 6 sq mm
30Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works.
314 module
326 module
33Supply & Fixing 240 V 6 A Modular type switch (Legrand: Myrius/Arterior /ROMA Urban as approved by E.I.C) on existing GI Modular type switch board having top cover plate and making necessaryconnections as required.
34Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Legrand: Myrius/Arterior /ROMA Urban as approved by E.I.C), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
35Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket [Make-(Legrand: Myrius/Arterior /ROMA Urban as approved by E.I.C] with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
36Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) ((Legrand: Myrius/Arterior /ROMA Urban as approved by E.I.C) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.
37Supply & fixing of Blank plate for modular board. (Make:- Legrand: Myrius/Arterior /ROMA Urban as approved by E.I.C])
38Fixing only single/twin fluorescent light fitting complete with all accessories directly on wall/ceiling by screws etc.
39Fixing only fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports incl. S&F EI conduit, ball socket/socket type ceiling plate and connecting the length of PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm) flexible copper wire of 1.10 mt. length.
40Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
41Fixing only lamp
42Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling.
43Fixing only outdoor / street light type light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc.
44Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
45Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter
4645 cm (18\\")
4730 cm (12\\")
4823 cm (9\\")
49Supply & Fixing Al. louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long)
50For 45 cm Exhaust fan (18\\")
51For 30 cm Exhaust fan (12\\")
52For 23 cm (9\\") Exhaust fan
53Fixing of wall bracket fan on wall/ceiling, S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length with wooden base on wall and complete with all fixing accessories incl. interconnection as per direction by EIC
54Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
55a) For 4 core 25 sqmm
56Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
57a) 4 core 25 sqmm cable
58Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish
59From 2.5 sqmm to 35 sqmm at an average depth of 75 mm infloor/pavement/wall etc.
60Laying of 4 core 25 sqmm cable on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting a s per direction of EIC
61Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
6232 mm dia
63Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:
64a) By ISI-Medium GI pipe
65Excavation of soil for installation of Earth Electrode and filling & ramming as to GS. (For soft soil)
66Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below in [13mm heavy gauge Polythene Pipe] on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages
67(i) No. 10 SWG Solid GI wire
68(ii) No. 4 SWG Solid GI wire
69Supplying & drawing of heavy gauge 13 mm, 3 mm thick Polythene pipe
70Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
71Supplying and delivery of LED Industrial Batten light made of CRCASheet Body (Thickness ≥ 0.50 mm) and construction as per relevantIS, along with LED lamp (Opal finish polycarbonate housing with Aluminium end-cap) voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range 0o to 40o C, internal surge protection of 2.5 KV(internal) with Short & Open circuit protection , THD < 10% , P. F.≥0.9, IP20, CRI >80, and minimum 40000 Burning Hours (Life projection shall be calculated as per TM-21 methodology), CCT 5700°K /6500°K, and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing, with Minimum 5 year OEM warranty. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. (System lumen efficacy ≥115 lm/Watt (Make: Signify / LT / Wipro)
72Twin fittings along with S/F of 2 no. 18-20 W LED lamps as per specification
73Single fittings along with S/F of 1 no. 18-20 W LED lamp as per specification
74Supply & delivery of 230 V, 50 Hz, single phase, 52 watts, 48\\" (1200 mm) Sweep, speed 320 rpm (minimum), A.C. Ceiling Fan and class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod (14 SWG & higher thickness), 2 nos. canopies, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 140 cu.m/min (minimum), without Regulator including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. (Make:- Crompton Greaves/EPC/Orient)
75Supply & delivery of 230 V, 50 Hz, single phase, 40 watts , 9\\" (230 mm) Sweep, speed 1350 rpm (minimum), A.C. Exhaust Fan and class of insulation: B, 3 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 650 cmh (minimum) including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. (Make:- Crompton Greaves/EPC/Orient)
76Supply & delivery of 230 V, 50 Hz, single phase, 48 watts, 12\\" (300 mm) Sweep, speed 920 rpm (minimum), A.C. Exhaust Fan and class of insulation: B, 4 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 1145 cmh (minimum) capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. (Make:- Crompton Greaves/EPC/Orient)
77Supply & delivery of 230 V, 50 Hz, single phase, 132 watts, 18\\" (450 mm) Sweep, speed 900 rpm (minimum), A.C. Exhaust Fan and class of insulation: B, 4 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 3965 cmh (minimum) capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. (Make:- Crompton Greaves/EPC/Orient)
78Supply & Delivery of 230 V, 50 Hz, single phase, 85 watts, 18\\" (450mm), speed 1325 rpm (minimum), Bracket Fan and class of insulation: B, 4 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body with metal back cover. Power Factor not less than 0.9 and minimum air delivery 110 cu.m/min (minimum), including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. (Make:- Crompton Greaves/EPC/Orient)
79Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminum body finish with corrosion resistance fasteners (SS hardware) & silicon gasket for proper sealing with driver as per the requirement with Driver efficiency >80%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range 0o to 50o C and working RH 10% - 90%, internal surge protection of 5 KV internal and external SPD min. 10 KV, L,N,E as per IEC 61000-4-5. The driver rated output wattage should be 10% to 15% higher than lamp rating and at least 2 driver for 200W & above and Driver efficiency >85%, THD < 10% as per IEC 61000-3-2 , P. F.≥0.9, IP- 66, IK-08 specified below, CRI >70, under voltage and over voltage protection, high efficiency lens with type II/III distribution as required with UV stabilized optical lens, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours (Life projection shall be calculated as per TM-21 methodology) and 70% of initial Lumen maintained till life ends. CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect and LED Chips of SMD mid to high-power (2.5 to 4 watt for 200 watt and above, as per required (LM- 80 tested) and necessary inter-connections with 1.5 sq mm FR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM comprehensive on-site warranty against manufacturing defects including driver and LED module. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (System lumen efficacy ≥135 lm/Watt) (Make: Signify / LT / Wipro)
8072 Watt
81Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD with powder-coated pressure Die-cast Aluminium with high-transmission opal PMMA/ polycarbonate/ prismatic diffuser having uniform light distribution and construction as per IS : 10322. The driver rated output wattage should be 10% to 15% higher than lamp rating and efficiency Driver >80%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range 00 to 400 C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD <10% , PF ≥0.9, IP20, CRI >80, life time (LED, Driver & electrical circuitary), of minimum 50000 Burning Hours (Life projection shall be calculated as per TM-21 methodology) and 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect and LED Chips of SMD Low to mid-power, as per requirement (LM-80 tested) and necessary inter-connections with 1.5 sq mm FR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM comprehensive on-site warranty against manufacturing defects including driver and LED module. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. System lumen efficacy ≥ 110 lm/Watt (Make:- Signify/LT/Wipro)
8222-24 Watt
83Supplying and delivery of following size Armoured cables XLPE/PVC insulated are designed for 1.1 kV Stranded Aluminium conductor, high tensile galvanized steel wire/strip armour for mechanical protection, and PVC/FR PVC outer sheathing power cable of following size. (IS 7098 Part - 1/2011 with Up To Date Amendments.) [Make: Gloster/Polycab/Havells/RR Kable as approved by E.I.C]
844 Core 25 Sqmm
85Supply & delivery of 4' 18W LED tube light (Philips MAS 1200mm 18W 865 T8I -2100lm LED Tube or equivalent model of LT / Wipro)
86Supply & delivery of 9W LED lamp (Philips Eye Pro or Wipro/LT eq.)
87Supply & fixing automatic single phase AC starter of 25 Amp capacity equipped with Timecheck, Voltcheck & Ampcheck and 3-digit display (Make- Electron-model no.-OPL-3+ or equivalent model of LT/Legrand as per dierction of E.I.C) to be fixed on 4 Module GI box with all fixing accessories complete as to G.S.
88Supplying and delivery of following size Un-Armoured cables XLPE insulated are designed for 1.1 kV Stranded copper conductor and PVC/FR PVC outer sheathing power cable of following size. (IS 7098 Part - 1/2011 with Up To Date Amendments.) [Make: Gloster/Polycab/Havells/RR Kabel as approved by E.I.C] through existing 25 mm dia PVC pipe incl. all required inter-connection etc. as per direction of EIC.
89a) single core 35 sq mm
90Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
91a) 35 sq mm
92Supply and fixing of Polyamide Cable Glands, High Quality PG Type (PG36 ) IP68 Waterproof Cable Gland [Make-Daystar or eq.] for supporting 35 sq mm copper conductor
93Supply and fixing 16 SWG GI sheet with 1.6 mm thick and dimensions of (300 mm x 200 mm) at gland position of motor terminals box by using screw or nut bolts, making holes (4 nos) for fixing PVC cable gland of type PG16.
94Disconnection & dismantling existing old Electrical installation, Switch-board, wiring, Electrical fitting/fixtures, fans, MCBDBs, cables etc with owns tools & takles incl. mending good damages and clearing/removing from the site and handed over to the authority or as directed by EIC. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57078741
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 01-09-2026
Authority
Authority Name Public Works Department
Work Description Tender for Repair, Replacement And Renovation Of Electrical Installation Work At Basement Area And Other Allied Works At Madhusudan Mancha, Dhakuria.
Basic Detail
Tender No WBPWD/EE-ECD/e-NIQ-56/2026-27
Bidding Type Tender
Location
City Kolkata
State West Bengal
Key Dates
Publish Date 18 Aug 2026
Submission Date 01 Sep 2026
Open Date 03 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 13257
Exemption Not Available
Document List
BOQ_5090990.xls
e4240701-c8e0-4d04-9276-7156497862c3.html
Tendernotice_1 (25).pdf
Tendernotice_2 (3).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Sep 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_5090990.xls

html

e4240701-c8e0-4d04-9276-7156497862c3.html

pdf

Tendernotice_1 (25).pdf

pdf

Tendernotice_2 (3).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders