Power Government Departments Closing in 6 days TDR #57078624

Tender For Stage Contract For Maintenance Of 33/11 Kv Receiving Stations For Sub Division Sumbal And Bandipora Only Within The Jurisdiction Of Std Ganderbal For The Year 2026-27 Or Till Next Stage Contract Is Finalized

Issued by Government Departments · ganderbal, Jammu and Kashmir
Tender Value
30 Lakhs
Estimated cost
Bid Submission
29 Aug 2026
6 days left
EMD
60000
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
ganderbal → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Stage Contract For Maintenance Of 33/11 Kv Receiving Stations For Sub Division Sumbal And Bandipora Only Within The Jurisdiction Of Std Ganderbal For The Year 2026-27 Or Till Next Stage Contract Is Finalized

BOQ

Name of Work:- Stage contract for Maintenance of 33/11 KV Receiving Stations for Sub Division Sumbal and Bandipora only within the jurisdiction of STD Ganderbal for the Year 2026-27 OR till next Stage Contract is finalized
Sl. No. Item Description
1Stage Contract for Maintenance of 33/11 KV Receiving Stations in respect of STD Ganderbal Sub Division Sumbal and Bandipora only
2Supply, Fabrication, testing and Commissioning of PVC insulated Copper Bus Bar including nuts and Bolts.(The job includes necessary modification fabrication of Busbar as per requirement & alignment to existing Panels).
3Supply installation Testing & Commissioning of 11 KV Vacuum Interrupters (800A/600A as per already installed) for below make.The job includes dismantling of damaged interrupter.
4Vijai, Easun Reyrolle, Alind, Alind, Electric Field, Pasca, Crompton, ABB, and out door type 11kv Breakers.
5Sudhir, Schneider
6Installation/Fixing, Testing & Commissioning of 11 KV Vacuum Interrupters of above makes including dismantling of damaged interrupter.
7Supply installation Testing & Commissioning of 11 KV vacuum Interrupters Housing of below mentioned make.
8Vijai and Easun Reyrolle (Per Phase)
9Alind (Assembly upper set/ Lower set).
10ABB/Electric Field/Crompton/S&S ( per Phase)
11Sudhir and Schneider (Per phase)
12Outdoor type PCVCB upper and lower part(Per phase)
13Installation, testing and commissioning of 11KV vacuum Interrupters Housing of above mentioned make including dismantling of damaged assembly.
14Supply Installation, testing and commissioning of of 11 KV CTs indoor type cast resin of following make and ratios including dismantling of damaged CT's and transportaion of Red material back to Divisonal store.
15750-375/5-5-5A Metering, Protection and Differential Core
16800-400/5-5-5 A Metering, Protection and Differential Core
17600-300/5-5-5 A Metering, Protection and Differential Core
18600-300/5-5 A Metering and Protection Core.
19400-200/5-5 A Metering & Protection Core
20300-150/5-5 A Mertering & Protection Core
21100-50/5-5 A Metering & Protection Core
2240-20/5-5A Metering & Protection Core
23Installation, testing and commissioning of 11 KV CTs indoor type cast resin of above makes & Ratios including dismantling of damaged CT's and Transportation of new set from divisional store to site including transportaion of Red material upto Divisonal store. (The job includes identification of damaged part so that exact part can be arranged from OEM)
24Supply, Installation, Testing and commissioning of Energy meter of Secure make with latest series premier 5000 of 11kv level and 33kv level with 5A secondary. 11kv/110v-5A / 33kv/110v-5A
25SITC of G.I channel iron, angle iron, flat iron etc including necessary fabrication as per requirement including paint job.
26Supply, Installation, testing and commissioning of 11 KV CT's outdoor type Dead tank type including dismantling of damaged CT's. (CT set to be provided should be of OEM as per already installed CT set) (The job includes identification of damaged part so that exact part can be arranged from OEM) including transportaion of Red material upto Divisonal store.
27600-300/5-5-5 A Metering, Protection and Differential Core
28400-200/5-5A Metering, Protection and Differential Core
29400-200/5-5A Metering & Protection Core
30SITC of 11 KV PT set indoor type (11KV/110V) ER, Electric Field, Alind etc.
31SITC of 11 KV PT indoor type (11KV/110V) of Schneider, CG etc.
32SITC of 11 KV outdoor Dead tank type PT's ( 11KV/110 V).
33Installation, testing and commissioning of 11 KV PT's (11 KV/110 V) indoor type and outdoor type including Transportation of new one from divisional store or otherwise to site including dismantling of existing PTs & transportation of Red Material upto Divisional Store
34Supply Installation, testing and commissioning of 33 kV Current Transformer with Metering and Protection core, P S Class (36kV, 70kV (rms), 170kVp, 25 KA for 3 sec, Accuracy 0.5, Burden 30 VA, 1Φ, Outdoor) (1 No per Φ) of following ratios.
35400-200/5-5-5 A (Metering, Protection and Differential Core )
36250-125/5-5-5 A (Metering, Protection and Differential Core )
37300-150/5-5-5 A (Metering, Protection and Differential Core )
38Installation, testing and Commissioning of 33 kV Current Transformer including Transportation of new one from divisional store or otherwise and Transportation of Red item back to Divisional store.
39Supply Installation, testing and commissioning of 33 kV PT's (33 kV /110 V single Phase outdoor type Potential Transformers
40Installation, testing and Commissioning of various 33 KV PT's
41Supply Installation, Testing and Commissioning of 11 KV VCB Panel including Transportation and supply of all accessories, clamps & Stand for commissioning of panel in (along with GTP and Test Certificate)
42Installation, Testing and Commissioning of 11 KV VCB Panel and supply of all accessories, clamps & Stand for commissioning of panel. including Transportation from divisional store
43Supply, installation, testing and commissioning of items in 33 KV C&R Panel of make OEM (The job includes identification of damaged part so that exact part can be arranged from OEM)
443 Element Master Trip Relay ( 2NC+8NO for each element)
45Single Element Master Trip Relay ( 2NC+8NO for each element)
46TNC Switch 25 Amp.
47Ampere meter with Selector switch Digital Programmable
48Voltmeter with selector switch Digital
49Tripping/Closing coils with housing complete 300 W Burden
50Repairing of items in 33 KV C&R Panel.
51Master Tripping Relay 4NO + 4NC, 36 Volt DC
52TNC Switch 25 Amp.
53Ampere meter with Selector switch Digital Programmable
54Voltmeter with selector switch Digital
55Supply,Installation, testing and Commissioning of various 33 KV VCB including supply of all accessories, clamps & collars for commissioning of VCB (along with GTP and Test Certificate)
56Installation, testing and Commissioning of various 33 KV VCB including supply of all accessories, clamps & collars for commissioning of VCB
57Supply,Installation, testing and Commissioning of various 33 KV C&R Panel including supply of all accessories, clamps & Stand for commissioning of C&R panel including Transportation from divisional store including earthing termination complete Job (along with GTP and Test Certificate)
58Installation, testing and Commissioning of various 33 KV C&R Panel including supply of all accessories, clamps & Stand for commissioning of C&R panel including Transportation from divisional store including earthing termination complete Job.
59Supply installation Testing & Commissioning of G I Pipe 9\\" Dia, 10 feet Long, 6mm thick along with Top end Base Plate (450mm x 450mm).
60Supply installation Testing & Commissioning of G I Pipe 6\\" Dia, 10 feet Long, 6mm thick along with Top end Base Plate (450mm x 450mm).
61Supply, installation, testing and commissioning of items of 33 KV VCB (The job includes identification of damaged part so that exact part can be arranged from OEM)
6233 KV Porcelain Post Insulator
63Operating Rods
64Closing Coils with Housing
65Tripping Coils wih Housing
66Contactor
67Gasket
68Operating Shaft
69Mechanism Housing
70Gear Assembly
71vacuum/gas charging valve
72Input/Output housing terminal pads
73Repairing of items of 33 KV VCB
74Operating Rods
75Operating Shaft
76Gear Assembly
77Supply of 33 KV Vacuum Interrupters (1250A as per already installed) for below make.
78Vijai, Easun Reyrolle, Alind, Alind, Electric Field, Pasca, Crompton, ABB, and out door type 11kv Breakers.
79Sudhir, Schneider
80Installation/Fixing, Testing & Commissioning of 33 KV Vacuum Interrupters of above makes including dismantling of damaged interrupter Including transportation of Red Material upto Divisional Store).
81Supply of 33 KV vacuum Interrupters Housing of below mentioned make .
82Vijai and Easun Reyrolle (Per Phase)
83Alind (Assembly upper set/ Lower set).
84ABB/Electric Field/Crompton/S&S ( per Phase)
85Sudhir and Schneider (Per phase)
86Outdoor type PCVCB upper and lower part(Per phase)
87Installation, testing and commissioning of 33 KV vacuum Interrupters Housing of above mentioned make including dismantling of damaged assembly including transportation of Red material upto Divisional store.
88Supply, installation, testing and commissioning of 33/11 KV Power Tranformer equipments/Items (The job includes identification of damaged part so that exact part can be arranged from OEM) including dismantelling of parts.
89Bucholz Relay
9033KV Bushing
9133KV Bush Rods
9211 KV Bushing
9311 KV Bush Rods
94Tap Changer complete
95WTI set with probe
96OTI set with probe
97Repairing of 33/11 KV Power Tranformer equipments/Items
98Bucholz Relay
99Tap Changer complete
100WTI set with probe
101OTI set with probe
102Installation, Testing & commissioning of Power Transformer including fixing of radiators (if required), topping up (oil to be provided by department) etc
1031 MVA OR of lower capacity
1043.15 MVA
1054 MVA
1065 MVA
1076.3 MVA
10810 MVA
109Dehydration/Filteration of Power Transformer Oil including providing of Filtration machine capable of centrifuge, heating, degassing, filtration value upto level load.
110Installation, Testing and Commissioning of following MCCB's with copper spreaders ISI Mark.
111100A 3-pole 36 KA
112125A 4-pole 36 KA
113250A 4-pole 36 KA
114400A 4-pole 36 KA
115630A 4-pole 36 KA
116Supply, Installation, Testing and Commissioning of MCCB Enclosure Box
117Providing and fixing of Gaskets of 12mm,10mm,6mm including drainage of oil (if reqd.), Dismantling of damaged gaskets/oil sealings and vice-versa of same after completing the job by way of dismantelling of transformer parts and Re-fixing of same.
118Radiator valve Gasket (12mm)
119Top cover peripheral gasket (12mm)
120Oil Sealing of HV-LV Bushings
121Tap Changer Body gasket (12mm)
122Sight glass (6mm)
123Inspection Plate (6mm)
12433KV outdoor CT Gaskets (10mm)
125Supply , Laying testing & commisioning of 33 KV 3 core XLPE Cable along with suitable heat shrinkable/push on cable termination kits (Make-3M/ Polycab/ Anchor/ Havells/ Gloster)
126300 sqmm
127120 sqmm
128Supply , fixing, testing & commisioning of 3 Core 33 KV Jointing Cable kits for XLPE cable of sizes
129400 sqmm
130300 sqmm
131120 sqmm
132Supply & Fixing of Heat shrinkable/ Push on cable kits with allied accessories Suitable for 33 KV 3-core XLPE cable including dismantling of existing damaged cable kits of following sizes
133400 sq.mm
134300 Sq.mm
135120 Sq.mm
136Supply , Laying testing & commisioning of 11 KV 3 core XLPE Cable along with suitable heat shrinkable/push on cable termination kits (Make-3M/ Polycab/ Anchor/ Havells/ Gloster)
137120 sqmm
138185 sqmm
139240 sqmm
140300 sqmm
141400 sqmm
142630 sqmm
143Supply , fixing, testing & commisioning of 3 Core 11 KV Jointing Cable kits for XLPE cable (Make-3M/ Polycab/ Anchor/ Havells/ Gloster)
144120 sqmm
145185 sqmm
146240 sqmm
147300 sqmm
148400 sqmm
149630 sqmm
150Fixing of 11 KV Heat shrinkable cable kits with allied accessories Suitable for 3-core XLPE cable including dismantling of existing damaged cable kits of following sizes
151185 Sq.mm
152240 Sq.mm
153300 Sq.mm
154400 Sq.mm
155630 Sq.mm
156Providing and fixing of 1'x1'Junction box of 14 SWG IP 65 protected as per Bis with inbuilt 36 No's Brass connectors mounted on din rail channels complete.
157Oil topping of equipments including Power Transformers, CT's, PT's and auxillary X-mers.
158Rectification of minor leaks of Power Transformers, CT's, PT's and auxillary X-mers.
159Supply & fixing of following battery charger accessories including dismantling & Modification of damaged accessories/ Items. (The job includes identification of damaged part so that exact part can be arranged from OEM)
160Power Diodes P-type/ N-type ( 40 to 100 A)
161Charger Coil 240/36V AC
162AVR Cord
163DC Voltmeter ( 0-60V) Digital
164DC Ampere meter (0-50A) Digital
165Variac 15/25 Amp, 0-240 A
166Repairing of following battery charger accessories
167DC Voltmeter ( 0-60V) Digital
168DC Ampere meter (0-50A) Digital
169Variac 15/25 Amp, 0-240 A
170Supply, laying, routing, installation, testing & Commissioning of damaged panel wiring using multistandard wire of sizes 1.5/2.5 sqmm including ferruling, thimbling etc
171Installation, testing commissioning of 33/0.433 KV Transformer equipments (if required) fixing of following items
1720.433 KV LV Bushing
1730.433 KV Bush rods
174Supply, Routing, laying, testing and commissioning of 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS , connecting ribs, bunching wire, ferruling, thimbling etc
17512 Core .
1768 Core
1776 Core
1784 Core
1792 Core
180Supply, Laying, installation, testing and commissioning of Chemical Earthing including digging of pits including connecting with present earthing complete job which includes 3m Copper in GI electrode 43mm diameter and termination using 40*6mm GI strip with mainhole cover
181Supply, Fixing, Fabrication, testing, commissioning of mechanical parts for various 11kV VCB's (including dismantling of assembly and damaged parts and refixing as per requirement to existing breakers (Pascal, Electric field, Schneider, ER, Alind, CG etc)
182Spring charging mechanism with allied accessories complete set of assembly for different 11kv vcb's
183HSS Gears of sorts for different sizes and applications used in VCB's of different make
184Close release steel pins of sorts
185Trip release steel pins of sorts
186locking cam set of sorts
187Rack and pinion set
188Torsion springs of sorts
189operating rod of sorts
190operating corn of sorts
191Making/Breaking springs of sorts
192loading spring of sorts with dampers
193epoxy holding insulators
194Main Links
195copper flexible ribbon/braid connections
196Copper finger contact 8mm french curved single type
197copper 12 finger contact
198Bunched strip copper contact for alind
199Spring charging Ratchet gear assesmbly with lever and gear complete
200Trippin coil housing with allied accessories of sorts
201Closing coil housing with allied accessories of sorts
202Expoxy/porcelain spout with copper bus bars of sorts of all kinds of breaker excluding Alind make
203Expoxy/porcelain spout with copper bus bars with inbuild CT Alind make.
204Cotter pins of sorts HSS
205Cotter spring pins HSS
206Dowell Steel pins
207Shaft locks/Pin Locks
208Trip strike lever of sorts
209Close strike lever of sorts
210Minor Re-alignment/Readjustment of mechanical parts
211DC Sprng Charging motors 25 to 250 V DC
212DC Sprng Charging motors 240V AC
213Repairing of mechanical parts for various 11kv VCB's (including dismantling of assembly and damaged parts and refixing as per requirement to existing breakers (Pascal, Electric field, Schneider, ER, Alind, CG etc)
214Spring charging mechanism with allied accessories complete set of assembly for different 11kv vcb's
215Supply, Fixing, Fabrication, testing, commissioning and repairing of Electrical parts/ Circuits for various 11kv/33KV VCB's (including dismantling of damaged Electrical parts/Circuits and refixing by way of re-wiring as per requirement to existing breakers/Pannels (Pascal, Electric field, Schneider, ER, Alind, CG etc)
21612 Point Male female control circuit contact
21724 Point Male female control circuit contact
21836 Point Male female control circuit contact
219Auxillary Switch 12 No+12 NC 16-25A with lever
220Auxillary Switch 8 No+8 NC 16-25A with lever
221Auxillary Switch 6 No+6 NC 16-25A with lever
222Anti pumping device with allied accessories
223Limit switch with 2 No+2Nc 16-25A with accessories
224Repairing of Trip circuit super vision circuit
225Reparing of Closing circuit
22636 VDC Master trip relay with 4 NO+4NC 25A High speed
22736VDC Auxilliary relay with 4NO+4NC High speed
228Driver relay DPDT 12 vdc with 2 NO+NC High speed
22911KV/110v based 4\\" Voltmeter digital programeable type
230CT Ratio Based 4\\" Amp. Meter digital programeable type
231ASS Switchs 25A
232VSS Switchs 25A
233LED indicators of different colors 36 VDC
234Push buttons 25A with 2NO+2NC
235MCB's of sorts 2A-32A 10KA c curve type
236Repairing of Pannel wiring complete job as per REC Standards.
237Installation Testing and commissioning of Tri-vector meters
238Supply, Testing and commissioning of Control relays with 3OC+1EF 2 Element based digital including necessary modification and minor wiring works complete job of following make.
239MIT- 114/104 (ER) make.
240Schneider
241Crompton 14C
242Ashida ADR241B/242B
243Simens 7SR
244Ashida 131A
245Ashida 141
246LNT M314A
247Supply, Installation, testing and commissioning of 11KV epoxy compound spouts with required Copper busbar as per requirement and as per the existing pannel requirement of below mentioned make including dismantling of damaged spouts including transportation of Red material upto Divisional store.
248Vijai (Per Phase)
249Alind (Sput with required CT/phase).
250Easun Reyrolle ( per Phase)
251ABB ( per Phase)
252ABB (Per Set)
253S&S ( per Phase)
254Electric Field ( Per Phase)
255Electric Field ( Per Set)
256Crompton ( Per Phase)
257Crompton ( Per Set)
258Sudhir/Schneider (Per phase)
259Sudhir/Schneider (Per Set)
260Hartek (Per Phase)
261Hartek (Per Set)
262Supply installation testing and commisioning of following tripping and closing coils for different types of VCB's including dismantling of existing damaged coils. The Tripping and closing coils must have burden between 250 to 350 watts at 30VDC & must follow the specifications of design of VCB's .
263Tripping/Closing coil of 11KV Alind make VCB
264Tripping/Closing coil of 11 KV ER/Vijai Make VCB
265Tripping/Closing coil of 11KV Electric Field Make VCB
266Tripping/Closing coil of 11KV ABB Make VCB
267Tripping/Closing coil of 11KV Crompton Make VCB
268Tripping/Closing coil of 11KV Stelmac Make VCB
269Tripping/Closing coil of 11KV Sudhir/Schneider Make VCB
270Tripping/Closing coil of 11KV Pascal Make VCB
271Tripping/Closing coil of 33KV ABB Make VCB
272Tripping/Closing coil of 33KV Crompton Make VCB
273Tripping/Closing coil of 33KV Stelmac Make VCB
274Tripping/Closing coil of 33KV Megawin Make VCB
275Installation, Testing, and commissioning of tripping and closing coils for different types of VCB's including dismantling of existing damaged coils. The Tripping and closing coils must have burden between 250 to 350 watts at 30VDC & must follow the specifications of design of VCB's .
276Supply installation testing and commisioning of
27733 KV Lightining Arrestor (33kV , 10KA)
27811 KV Gapeless surge arrestor, 9KV , 10KA LA
279Installation testing and commisioning of
28033 KV LA
28111 KV LA
282Providing & Fixing of
2833/5 15 AMP socketwith switch
2843/5 6 AMP socket
2856 Amp switches
286Lamp Holders
28712 V DC emergency Lamp
288Fan dimmer
2899/15 W LED Lamps
2901400 mm Ceiling Fan
291200 mm Exhaust Fan
2926-32 Amp MCB
29340 Amp MCB
29425 Amp Industrial type Plug Socket with MCB in MS box
295Providing and laying of Insulating HT Rubber Mats ( 1000x 2500) 12 to 25 mm thick
296Providing and laying of 2 core 16 sqmm 1.1 KV PVC cable for AC / DC distribution including Termination
297Supply, installation, testing and commissioning of Following items for use in both 11KV VCB Panel & 33KV C&R Panels
298BMR mechanism of different makes
299Shower contact
300Selector switch 16 Amp
301Trip circuit supervision Relay
302Indication LED's of various colors
303Buzzer
304Supply, installation, testing and commissioning of OLTC Panel for Power Transformers
305Supply, installation, testing and commissioning of XLPE LT Cable 3.5 Core, armoured, Fire resistant of sizes
30695 sq.mm
307120 sq.mm
308185 sq.mm
309240 sq.mm
310300 sq.mm
311400 sq.mm
312Loading Transportation and unloading at site of work from Divisional stores
31333KV VCB/ 33KV C&R Panel/ 11 KV VCB Panel
31433KV CT/PT Set
315Transportation of 11KV VCB to the workshop of the contractor and back to the Receiving station in case the repairing of 11KV VCB is not possible at site.
316Carriage of Major Red Materials from Site to Store including unloading
31711KV Pannels
318C&R Pannels
31933 KV CT
32033KV PT
32133KV/ 11 KV isolators and small item battery etc
322Damaged Cable
323Ac/DC Board
3247.5 KV, 90-240 , Servo Stablisers
325SITC of following Items
32611 kV Isolator, Double Break,3-pole, 630Amp, horizontal mounting Type, with Earth Switch.
327800 AMP 11 KV Isolator without Earth balde
32833 kV Isolator with Earthing Blade (36kV,800A, Outdoor,3 poles, 25 kA)
32933 kV Isolator without Earthing Blade (36KV,800A,Outdoor,3 poles,25 KA)
33033 kV Lightening Arrestors (33 kV, 10kA, Station class, ZnO, Polymer) gap less (1 No. per Φ)
33133 kV 10kN Polymer Post Insulator 36kV,170kV Impulse, creepage distance 1224m
33233 kV 10kN porcelene Post Insulator 36kV,170kV Impulse, creepage distance 1224m
33311kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp
334120 mm² XLPE LT Cable 4 Core, armoured, FRLS
335MCCB ‐ 160 Amps , 36 kA, 4P Ics =100% Icu at 415 (kA rms)
33611 kV Horn Gap Fuse Set 3 Phase 200A
3378 Pin Plug in relay DC- 24 t0 36 Volt , 10-25 AMP
3388 Pin Plug in relay AC- 240 Volt , 10-25 AMP
3393 element Auxlary relays , ABB for Trf protection
3406 Way Multi-way Microprocessor based electronic Annunciator to be programmable for at least two types of sounds) for the visual and audible alarm with built-in watch dog. it shall have provision for connection with accept/reset/lamp test/mute Push buttons for proper functions. Electronic annunciator shall have provision for connection with Electronic Buzzer/Electronic Bell for Trip & Non-Trip Audio Alarm of common annunciation scheme.it should have separate colored windows for Trip & Non-Trip Annunciation for easy detection. Annunciator fascia units shall have translucent plastic windows for each alarm point.Electronic Annunciator shall have first Fault Indication Facilities & System Watch Dog. Annunciator fascia plate shall be engraved in black lettering with respective alarm inscription, size of the lettering shall be about 5 mm. The inscriptions shall be visible only when the respective fascia LED will glow.one alarm buzzer meant for non-trip alarms and one bell meant for trip alarms shall be provided.Control Voltage 30 V DC+/-25%. 2 No.,s of LEDs per window
34116 Way Multi-way Microprocessor based electronic Annunciator to be programmable for at least two types of sounds) for the visual and audible alarm with built-in watch dog. it shall have provision for connection with accept/reset/lamp test/mute Push buttons for proper functions. Electronic annunciator shall have provision for connection with Electronic Buzzer/Electronic Bell for Trip & Non-Trip Audio Alarm of common annunciation scheme.it should have separate colored windows for Trip & Non-Trip Annunciation for easy detection. Annunciator fascia units shall have translucent plastic windows for each alarm point.Electronic Annunciator shall have first Fault Indication Facilities & System Watch Dog. Annunciator fascia plate shall be engraved in black lettering with respective alarm inscription, size of the lettering shall be about 5 mm. The inscriptions shall be visible only when the respective fascia LED will glow.one alarm buzzer meant for non-trip alarms and one bell meant for trip alarms shall be provided.Control Voltage 30 V DC+/-25%. 2 No.,s of LEDs per window
342Hooters for trip alarm
343Bell for DC & AC Fail
344LED semaphone for Breaker for C&R Pannels ( The semaphore indicators shall be three position type, having one intermediate position to indicate the \\"DCsupply fail\\" condition)
345LED semaphone for Isolator with Earth balde for C&R Pannels
346LED semaphone for Isolator without Earth balde for C&R Pannels
347Push Buttons
348Cubical Illuminating Lamps 9- 18 watt LED
349Pannel thermo stat
350AC Fail & DC Fail Relays ( 80C & 80D)
351Pannel Heaters
3522 -16 AMP cartiridge fuses
353Rating Kit Kat fuses with base
354terminal blocks
355terminal blocks stud type 2.5mm
356CT & PT Marshalling Box with 36 Teminal blocls
3571250 Amp Flexible Copper Jumpers (bread tye )
3583Phase CT Based Voltmeter, Ampere meter and multifunctional meter should be used of size96 x96 with accuracy class of CL-0.5
35911 KV porceline pannel insulators
36050 mm dia .10mm thick alimunium IPS Tubes
36150 mm dia .10mm thick alimuniom IPS Tubes Tubes jointors
362Transfromer LT Distribution Box for:- 100 kVA DTR with 160 Amp MCCB 3P 16 kA for incomer & 100 Amp MCCB 3P 16 kA 2 No.s for Outgoing Circuits. , 3Pase , with indicators , Neutral Bus Bar, & Volt meter
363LT Cable 3.5 core sqmm 70 Sqmm
364LT Cable 3.5 core sqmm 95 Sqmm
3651.1 kV Heat Shrinkable Cable Termination Kits (Indoor/Outdoor)
3664NO+4NC auxilary contact with rod
3676NO+6NC auxilary contact with rod
3688NO+8NC auxilary contact with rod
36912NO+12NC auxilary contact with rod
37024 male female contract for 11 KV Pannel
3715-10 Amp Limit switches
372Pannel Motors
37330 to 250 volt Brige Rectiifes for motors
3742\\", 3HP dewartering Pump along with all accessiries line delivery pipe,Starter, suction pipe & fiundation ,Cabling etc
37532Amp , 3 Phase , DC 24-250 Volt Contactors
37632Amp , 3 Phase , AC 240 Volt Contactors 3 Pole Power Contactors - Type MNX-22
377Limit Switchs wuth 2 No+ 1 NC contacts
378Distribution Panel (415 V, AC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43. 200 Amps Switch Fuse disconnector for incoming supply and 5 No TPN MCB's (16-125 Amps ) and 5 No DP MCBs (0-32A), rectangular busbar suitable for 200 Amps continuous Supply including indication lamps and cables and other accessories
379Distribution Panel (30 V, DC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43 for 2 No battery incoming supply with 2 No 63 Amps DP MCBs for incoming supply Double busbar of adequate size, 12 No DP DC MCB (0-32A) including indication lamps and cables and other accessories
380Yard Lighting by way of Providing 12.5 Mtr motorised High Mast with 4 No.s of 200 W LED flood lights on each High Mast complete with earthing , and foundations
3811200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required
3822x 16 sqmm 1.1 KV aroured Cable
38312 x5mm copper Battery connector
384Chequered Plates 6mm thick MS
385Rubber Mat 1mx2m 19mm thick
386300mm Heavy Duty Exhuast Fan
387SITC of Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group A
388SITC of Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
389SITC of Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required
3902 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
3912 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
3922 X 4 sq. mm + 1 X 4 sq. mm earth wire
3932 X 6 sq. mm + 1 X 6 sq. mm earth wir
3942 X 10 sq. mm + 1 X 6 sq. mm earth wir
395Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required
3965/6 amps switch
39715/16 amp switch
3983 pin 5/6 amp socket outlet
3996 pin 15/16 amp socket outlet
400Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
401Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required
4021 or 2 Module (75mmX75mm)
4033 Module (100mmX75mm)
4044 Module (125mmX75mm)
4056 Module (200mmX75mm)
4068 Module (125mmX125mm)
40712 Module (200mmX150mm)
408Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
409Supplying and fixing suitable size GI box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required
410Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required
4118 way, Double door
41212 way, Double door
413Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without CB/RCCB/Isolator)
4144 way (4 + 12), Double door
4156 way (4 + 18), Double door
416Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
417Single pole
418Double pole
419Triple pole and neutral
420Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. asrequired.
421Supply installation Testing and commissioning of
42218 Watt LED Lamps
423Chargable DC lights
424Feeder Name Board
425Danger Board
42636 Volt , 1NC+3No 24-26 Volt Relay 10 Amp
42711 KV Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
428G.I Steel of all sorts
429150 mm GI Pipe with reqd. Number of collars (6\\")
430Anti-Climbing Device with Clamps
431Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 3 mtr long through GI Strip (25x3)mm
432Rotary /Selector switch Voltage between Phases with OFF 16amp
433Rotary /Selector switch Voltage between Phases & individual Phase to Neutral with OFF 16amp
434Rotary /Selector switch Line Currents with OFF with CT
435Breaker Control Switches (Trip - Neutral - Close) 1Trip + 1Close 25AMP
436Breaker Control Switches (Trip - Neutral - Close) 2Trip + 2Close 25AMP
437QuartzTime Switch ,240 VAC Base/DIN Mounting
438Digital Time Switch ,24 VDC 1 C/O Base/DIN 25 ON/OFF Each
439Standard Illuminated Actuators With LED [8531) Twin Touch Y-Yellow A-Amber
440Standard Push Button Actuators Ø 22.5 mm
441Mushroom Head Actuator ‘Push Turn Type’with Legend - STOP Contact - 1 ‘NC’ for Stop
442Pannel indicators Gen Next Pro LED Indicator 22.5 mm( Red, Green ,Yellow & A-Amber ) 24 - 48V DC ,240VAC
443Pannel indicators Gen Next Pro LED Indicator 22.5 mm( Blue & White ) 24 - 48V DC ,240VAC
444Pannel indicators Gen Next Pro LED Indicator 22.5 mm( Red, Green ,Yellow & A-Amber ) 24 - 48V DC
445LATCHING FLUSH PUSH BUTTONS with 1NO+1NC
446TWIN ACTUATORS Control & Signalling Devices 22.5 Ø Double Flush with IO Mark Plastic
447TWIN ACTUATORS Control & Signalling Devices 22.5 Ø Double Flush with IO Mark and WITH LED Metal
448TimeDelay relay TDR 240 VAC/24 VAC/DC
449HRC fuse 2- 32 Amp CNS (Off Set) clip in Type
450HRC fuse 2- 32 Amp
451Fuse holders & Fuse bases suitable 2-32 Amp
452Porcelain Rewirable Fuse Holder (Kit-Kat
4533Phase volt meter 3 line display
4543Phase Ampere meter 3 line display
455VAF meter
456Limit Switch With Push Rod & PlasticProtective Cover 1 NO+ 1 NC
457Junior Stroke Counter
458Limit Switch With Push Rod & PlasticProtective Cover 2NO + 2NC 1436
459Copper Brushes for Spring charging motor
460solder less Terminals
461Insulated Ring Terminals 3.7 to 6.4 mm
462Insulated Spade Terminals 3.7 to 6.4 mm
463Insulated Pin Terminals 1.7 to 2.7 mm
464HRC fuses (BS) 3NW Blade tag type 0.5 to 16Amp
465HRC fuses (BS) 3NW Blade tag type 25 to 32Amp
466Fuse holders 3NW type
4677PJ Trip Relays 7PJ1321-5AA21-0AA0 TCS relay, 2CO, SR, Aux 24-240VAC/DC, BI 24-240VDC
4687PJ Trip Relays 7PJ1212-6EB01-0AA0Trip relay with hand reset contacts with flag, DC 24-48, 4NO+1NC, high burden
4697PJ Auxiliary Relays 7PJ1132-6CA00-0AA0Auxiliary relay Three Element, hand reset with flag, 24-48 DC, 2NO, Low burden
4707PJ Auxiliary Relays 7PJ1111-6DA20-0AA0Auxiliary relay Single Element with self reset contacts with flag, 110V DC, 3NO+2CO,Low burden
471Auxiliary Contactors , 3RH2 (S00) with “Mechanically linked contact elements” with AC coil ( 3NO+1NC)
472Auxiliary Contactors , 3RH2 (S00) with “Mechanically linked contact elements” with DC coil ( 3NO+1NC)
473Supply of following items
474Supply of PORTABLE 5KW PETROL GENSET with FUEL CONSUMPTION 2L/HOUR(APPROX) Mileage) FUEL TANK CAPACITY: 25L NOISE LEVEL:85DB(APPROX)
475250A Stick Welder, 220V MMA Welding Inverter Gasless Tool, IGBT Inverter Welding Machine, Portable Mini MMA Welder Machine with Digital LED Display, Arc Force, Hot Start, Anti-Stick
476Hydraulic Crimping Tool 10 Tons Battery Cable Lug Terminal Crimper
477Gas Can Butane/LPG Single Nozzle With 1Pc Torch Gun + Butane Can 500ML
478Brush Cutter 52cc 2 Stroke 2.4 HP Petrol Engine Heavy Duty Grass Trimmer with 80T Blade Chain Head and Trimmer Attachments
479suction pump 5 HP
480Havells 100W LED Flood Light, Centura Neo 6K IP66 Waterproof Led Lights with 120° Wide Beam-LED Lamp Lights for Yard,
481STRONG WAVE Ultrasound Rat Repellent
482Portable 12mm Drill
483Magnetic Drill
484Pulling Machine /Turfer along with Camlog suitable upto 200 sqmm ACSR
485Pulling Machine /Turfer with Chain Pulley along with Camlog suitable upto 200 sqmm ACSR
486Grinder Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57078624
AUTHORITY Government Departments
TENDER VALUE 30 Lakhs
LAST DATE 29-08-2026
Authority
Authority Name Power Development Department
Work Description Tender For Stage Contract For Maintenance Of 33/11 Kv Receiving Stations For Sub Division Sumbal And Bandipora Only Within The Jurisdiction Of Std Ganderbal For The Year 2026-27 Or Till Next Stage Contract Is Finalized
Basic Detail
Tender No STDGBL e-NIT NO 21 OF 2026-27 DATED 17-08-26
Bidding Type Tender
Location
City ganderbal
State Jammu and Kashmir
Key Dates
Publish Date 18 Aug 2026
Submission Date 29 Aug 2026
Open Date 31 Aug 2026
Finance
Tender Value 30 Lakhs
Tender Fee 1000
EMD 60000
Exemption Not Available
Document List
BOQ_1072865.xls
df0d9b1b-6930-45eb-8590-0b849728e4cf.html
SBD21.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Aug 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1072865.xls

html

df0d9b1b-6930-45eb-8590-0b849728e4cf.html

pdf

SBD21.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders