Power Government Departments Closing in 11 days TDR #57078546

Tender For Erection Work Of 220/132Kv 200 Mva Transformer At 220Kv Gss Balotra (Boq1)

Issued by Government Departments · Barmer, Rajasthan
Tender Value
9.86 Lakhs
Estimated cost
Bid Submission
31 Aug 2026
11 days left
EMD
19800
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Barmer → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Erection Work Of 220/132Kv 200 Mva Transformer At 220Kv Gss Balotra (Boq1)

BOQ

Name of Work:- ERECTION WORK OF 220/132KV 200 MVA TRANSFORMER AT 220KV GSS BALOTRA (BOQ1)
Sl. No. Item Description
1Laying of earth mesh with 25mm / 28mm dia. M.S. Rod at a depth of 0.80 metre from top level of foundations, including excavation of trench of required depth and backfilling of the same, transportation of M. S. Rods from site store to locations, welding of M. S. Rod to M. S. Rod along the length, at crossings and with earth electrodes as per drawing, application of bitumen compound and covering with bitumen impregnated tape on all welded joints, for the type of soil prevalent at 0.80 metre below top level of foundations (M. S. Rod of above sizes & M. S. Flat as required shall be made available by RVPN).a)In case electricity is made available by RVPN without chargesi)Any soil,soft rock other than hard rock
2Laying of earthing risers of 50x6mm / 50x10mm / 50x12mm size M.S.Flat at a depth of 0.80 meter from top level of foundations, Including excavation of trench of required depth and backfilling of the same, transportation of M.S.Flat from site store to location, preparation of risers, bending as per requirement (after heating if necessary), fixing on and welding / bolting to equipment / structure and peak of structures, laying in the trench, welding to the earth mesh of M.S. Rod as per drawing, including welding of extra length of M.S.Flat if required, application of bitumen compound and covering with bitumen impregnated tape on all welded joints, painting of all surface of risers above ground level with red oxide and green paint, for the type of soil prevalent at 0.80 meter below top level of foundations (M.S.Rod of above Sizes & M.S .Flat as required shall be made available by RVPN)a)In case electricity is made available by RVPN without chargesi)Any soil, soft rock other than hard rock
3Placing / Driving of earth electrode of 25 / 28mm dia M.S.Rod of Length 3.30 meters (approx) to a depth of 3.80 meters from the top level of foundation, including excavation of pit as required and back filling of the same, transportation of M. S. Rod from site store to locations, cutting of M.S.Rod to desired length, preparation of one end as spike if necessary, welding of earth electrode to earth mesh of M. S. Rod as per drawing, application of bitumen compound and covering with bitumen impregnated tape on all welded joints, for the type of soil prevalent at 3.80 meters below top level foundations (M.S.Rod of above sizes & M.S.Flat as required shall be made available by RVPN)a)In case electricity is made available by RVPN without charges.i)Any soil,soft rock other than hard rock
4BUS- BAR WORK:STRINGING of 220 KV, 132 KV, 33 KV & 11KV Bus Bar of ACSR & Tarantulla conductor, including transportation of conductor, disc insulators and tension hardware from site stores to location, laying and cutting required length of conductor, cleaning and assembly of disc insulators as required along with fitting of bolted type or compression type tension hardware as made available, making up at one end, stringing of conductors between the beams with specified sag and tension, also equalizing sag and fitting spacers and spacer T-clamps for twin conductor, for three phases of conductors in each bus-section.(Per jumper basis)ii) Any Double Conductor
5JUMPERS of any conductor ( 3 nos. Y- type) between bus to equipment. or between equipment to equipment or between bus to bus, including transportation of conductor, disc insulators and hardware from site stores to locations, cleaning and assembly of disc insulators as required along with fitting of suspension hardware and erection as required, cutting required length of conductor, making connections, fixing of spacers & spacer T-clamps as required, tightening of clamps / connectors, dressing, etc, for three phases. (Per jumper basis)i) Any Conductor
6ERECTION OF SUB-STATION EQUIPMENTS:Erection of Current Transformer / Potential Transformer / Capacitive voltage Transformer / Series Reactor / Residual Voltage Transformer / Neutral Current Transformer with clamps & connectors on already erected steel structure including transportation from site store to location, fabrication of base frame, fixing of terminal connectors, tightening of nuts & bolts etc. complete in all respects.ii) 132 KV CT / PT / CVT
7Erection of IsoIators (Motorised/Non motorised) on already erected steel structure including transportation of base frame, P. I.’s, contacts, mechanism box, clamps & connectors, etc. from site store to locations, minor fabrication as required, and fixing of terminal connectors, etc., adjustment/ alignment of isolator and its earth blade, if provided, for their smooth operation and final adjustment if required after jumpering including erection of PIi)220KVa)Without Earth blade
8f) Tandom
9Erection of IsoIators (Motorised/Non motorised) on already erected steel structure including transportation of base frame, P. I.’s, contacts, mechanism box, clamps & connectors, etc. from site store to locations, minor fabrication as required, and fixing of terminal connectors, etc., adjustment/ alignment of isolator and its earth blade, if provided, for their smooth operation and final adjustment if required after jumpering including erection of PIii) 132KVa)Without Earth blade
10f) Tandom
11Erection of 220KV Class EHV Transformer (Gas filled tank already placed on foundation with wheels), including transportation of accessories from site store to locations, erection of HV, IV, LV & Neutral bushings, erection of cooler bank with associated pipe line, radiators, fans, pump, main & OLTC conservators, equalizing pipe line, marshalling kiosk, fans etc. as per manufacturer’s drawing, preparation of oil, oil filling, dehydration of transformer along with cooler bank & diverter switch (filter machine, oil tank & operating staff shall be provided by RVPN), electrical wiring from individual equipment, e.g., Buchholz relay, MOLG, OSR, Fans, Pumps, Bushing CT’s etc. to marshalling kiosk, etc., but excluding testing & commissioning of transformer.a) If electricity is available & arranged by RVPN without charges.
12Erection of Control & Relay panel complete in all respect, including transportation from site store to control room , placing on foundation /cable trench as per layout, interconnection between control & relay panel and with existing panel fixing of site /top covers and doors earthing to existing earth strip in control room, connection of bus wiring to existing panel and between control and relay panel as required.iii) Simplex panel, Dc panel, RTCC panel, PLCC panel, etc
13LAYING AND TERMINATION OF CABLES:Control Cable:i) Laying of P.V.C insulated unarmoured / armoured control cable of 1.1 KV grade with copper conductor in cable trenches as per specification as required, including transportation of cable drums from site store to locations, laying in cable trenches, cutting to required length, placing them on cable racks / cable trays / cable batten & dressing, including removing and re-fixing trench covers as required, making necessary connections, testing, cable marking on both the terminating ends, etc. as required for all sizes from 2C x 2.5 sq.mm to 20C x 2.5 sq.mm, 4C x 4 sq.mm and 4C x 6 sq.mm.a)Unarmoured control cable
14ii) Fixing of control cable in position with single compression nickel plated brass cable glands confirming to IS :12943 &having three matel washers and one rubber ring, including preparation of cable and drilling of corresponding holes in gland plates etc. as required,& including cost of cable glands, for each cable gland of size.a) 19mm unarmoured control cable
15c) 25mm unarmoured control cable
16iii) Termination of wires of cables with copper conductor using copper terminal ends (pin or ring type) as required of Dowell’s or equivalent make as approved by the Engineer –in- charge duly crimped with crimping tool, including making wire ends ready for crimping , ferruling & dressing of wires etc. as required, including cost of material ends for all wires, for each cable at both ends for cables of the following sizes.a) 2.5 Sq. mm for any number of core
17b) 4 Sq. mm for any number of core
18Dismantling of 220 KV, 132 KV, 33 KV & 11KV Bus Bar of ACSR & Tarantulla conductor, including transportation of conductor, disc insulators and tension hardware from location to site stores, laying and cutting required length of conductor, cleaning and assembly of disc insulators as required along with fitting of bolted type or compression type tension hardware as made available, making up at one end, stringing of conductors between the beams with specified sag and tension, also equalizing sag and fitting spacers and spacer T-clamps for twin conductor, for three phases of conductors in each bus-section.(Per jumper basis)ii) Any single conductor
19Dismantling of jumpers of any conductor ( 3 nos. Y- type) between bus to equipment. or between equipment to equipment or between bus to bus, including transportation of conductor, disc insulators and hardware from site stores to locations, cleaning and assembly of disc insulators as required along with fitting of suspension hardware and erection as required, cutting required length of conductor, making connections, fixing of spacers & spacer T-clamps as required, tightening of clamps / connectors, dressing, etc, for three phases. (Per jumper basis) i) Any Conductor
20Dismantling of Current Transformer / Potential Transformer / Capacitive voltage Transformer / Series Reactor / Residual Voltage Transformer / Neutral Current Transformer with clamps & connectors on already erected steel structure including transportation from location to site store, dismantle of terminal connectors with nuts & bolts etc. complete in all respects.ii) 132 KV CT / PT / CVT
21Dismantling of IsoIators (Motorised/Non motorised) on already erected steel structure including transportation of base frame, P. I.’s, contacts, mechanism box, clamps & connectors, etc. from site store to locations, minor fabrication as required, and dismantle of terminal connectors & PI's.a) 220KV Isolator Without Earth Blade
22f) 220KV Isolator Tandem
23a) 132KV Isolator Without Earth Blade
24d) 132KV Isolator Tandem
25Dismantling of 220 KV Class ENV Transformer (Gas filled tank already placed on foundation with wheels), including transportation of accessories from site store to locations, erection of HV, IV, LV & Neutral bushings, erection of cooler bank with associated pipe line, radiators, fans, pump, main & OLTC conservators, equalizing pipe line, marshalling kiosk, fans etc. as per manufacturer’s drawing, preparation of oil, oil filling, dehydration of transformer along with cooler bank & diverter switch (filter machine, oil tank & operating staff shall be provided by RVPN), electrical wiring from individual equipment, e.g., Buchholz relay, MOLG, OSR, Fans, Pumps, Bushing CT’s etc. to marshalling kiosk, etc., but excluding testing & commissioning of transformer.a) If electricity is available & arranged by RVPN without charges.
26Dismantling of Control & Relay Panels complete in all respects including transportation from site store to control room, placing on foundation / cable trench as per layout, interconnection between Control & Relay panels and with existing panels, fixing of side / top covers and doors, remove earthing to existing earth strip in control room, disconnect of bus wiring to existing panel and between control and relay panel, as required.iii) Simplex Panel, DC Panel, RTCC Panel, PLCC Panel, etc.
27LAYING AND TERMINATION OF CABLES:A. Control Cables:ii) Fixing of control cables in position with single compression nickel plated brass cable glands confirming to IS: 12943 & having three metal washers and one rubber ring, including preparation of cable and drilling of corresponding holes in gland plates etc. as required & including cost of cable glands, for each cable gland of size.a) 19mm unarmoured control cable
28c) 25mm unarmoured control cable
29iii) Termination of wires of cables with copper conductor using copper terminal ends (pin or ring type as required of Dowell’s or equivalent make as approved by the Engineer-in-Charge) duly crimped with crimping tool, including making wire ends ready for crimping, ferruling & dressing of wires etc. as required, including cost of terminal ends for all wires, for each cable at both ends for cables of the following sizes.a) 2.5 Sq.mm for any number of core
30b) 4 Sq.mm for any number of core
31Dragging charges for 220/132KV 100MVA Transformer from foundation to suitable place in yard of 220KV GSS Balotra including removing wheel as per requirement.
32Air dryer generator unit for erection / installation work of 220/132KV 200 MVA transformer at 220KV GSS Balotra
33Vacuuming of Transformer & Dehydration / Filtration & recondition of transformer oil of 220/132KV, 200 MVA Power Transformer at 220 KV GSS Balotra along with man and machine (By Providing high vacuum filter machine With 2 Nos. vacuum pipes & oil testing kit having 100KV capacity)
34For providing the tank of capacity (approx.) 20 to 25KL by contractor on per day basis including transportation charges Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57078546
AUTHORITY Government Departments
TENDER VALUE 9.86 Lakhs
LAST DATE 31-08-2026
Authority
Authority Name Rajasthan Rajya Vidyut Prasaran Nigam Ltd
Work Description Tender for Erection Work Of 220/132Kv 200 Mva Transformer At 220Kv Gss Balotra (Boq1)
Basic Detail
Tender No BN-1410002607
Bidding Type Tender
Location
City Barmer
State Rajasthan
Key Dates
Publish Date 18 Aug 2026
Submission Date 31 Aug 2026
Open Date 31 Aug 2026
Finance
Tender Value 9.86 Lakhs
Tender Fee 1180
EMD 19800
Exemption Available
Document List
5f12da9d-59f0-4165-915a-8d69693066c7.html
Biddoc1.pdf
BOQ_1048144.xls
Tendernotice_1 (52).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Aug 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

5f12da9d-59f0-4165-915a-8d69693066c7.html

pdf

Biddoc1.pdf

xls

BOQ_1048144.xls

pdf

Tendernotice_1 (52).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders