Tender For Repairs To Flooring, Joinery,Sanitary Fittings , Cleaning Of Sewage Lines And Periodical Services At Icgs Kavaratti At Under Ge(Navy) Lakshadweep
Tender Value
24.63 Lakhs
Estimated cost
Bid Submission
08 Sep 2026
15 days left
EMD
49260
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Lakshadweep District → Lakshadweep
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repairs To Flooring, Joinery,Sanitary Fittings , Cleaning Of Sewage Lines And Periodical Services At Icgs Kavaratti At Under Ge(Navy) Lakshadweep
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of brick work / PCC block masonry built in cement mortar complete all as specified and as directed. |
| 2 | M&L pre-cast cement concrete block masonry 1:3:6 type C1 (20mm graded aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar 1:4 complete all as specified and as directed. |
| 3 | M&L PCC 1:4:8 type D2 by by using 40mm graded crushed stone aggregate as in foundations, filling and mass concreting complete all as specified and as directed. |
| 4 | Taking down cement plaster on brick walls or stone walls any descrition etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 5 | M&L for 15mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar (1:4) finished even and smooth without using extra cement including mixing of water proofing compound complete all as specified and directed (Note: WPC will be measured and paid seperately) |
| 6 | Supply only liquid water proofing compound |
| 7 | M&L for 15mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar (1:6) finished even and smooth without using extra cement complete all as specified and directed |
| 8 | M&L for 05 mm thick cement plaster on faces of brick work or concrete surfaces in cement mortar (1:3) as in ceiling finished even and fair complete all as specified and directed. |
| 9 | M&L cement concrete 1:2:4 type B0 byusing 12.5 mm graded stone aggregate in coping, kerbs, benching and the like, including weathering slighthy rounded or chamfered angles and throating as directed including necessary form work complete all as specified and as directed |
| 10 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi- tred/stopped ends etc complete all as specified and as directed. |
| 11 | M&L RCC 1:2:4 type B1(using 20mm graded stone aggregate) as in beams, cantilevers,bressumers, lintels over 1.5m span including necessary form work complete all as specified and as directed . |
| 12 | M&L Precast reinforced cemeri concrete cover slab 1:1.5:3 type A- 1, (using 20mm graded stone aggregate) set in cement moprtar 1:4 including necessary form work complete all as specified and as directed . |
| 13 | M& L mild steel TMT CRS bars 10 mm dia and over cut to length, bent to shape, required including cranking, bending, spirally for hopping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips , including embedding in concrete, as necessary, complete all as specified and directed. |
| 14 | Cleaning of gully traps/ inspection chamber of any size by any means including flushing by water complete all as specified and directed. |
| 15 | Removing the blockage of WC Indian / Europen type, urinal / bath or kitchen traps including cleaning of WC pan / floor traps / Nahani traps and removing blockage of down take pipes up to 1st manholes complete all as specified and as directed . |
| 16 | Pumping out complete water , liquid water and removing / desilting the sludge and cleaning the septic tank complete including plugging the inlet line temporary and diverting the flow into the drain at newly made trench and taking precautionary and safety measures and removing silt to a distance exc 50m but n exc 100 m from the septic tank and burring in pit including provision of pit of required size in any type of soil after spreading line etc for septic tanks of capacity 10 to 25 users complete all as specified and as directed. |
| 17 | All as per item No 16.00 here-in-before but septic tanks of capacity 25 to 50 users complete all as specified and as directed. |
| 18 | Cleaning of blocked sewage line of 150 mm dia bore by rodding from one manhole to next manhole, washing thouroughly with fresh water & removing all sludge at a distance exceeding 100m but not exceeding 200m from the sewage line incuding removing existing manhole covers & refixing properly after cleaning and taking all safety precautions complete all as specified and as directed. |
| 19 | Cleaning of man holes of size 750X750mm to 900 X1200mm including pumping out liquid sludge / waste materials, taking out solid materials from man holes /chambers burrying the debris obtained from the man hole at a distance exc 100 m and n.exc 200m and washing manhole with fresh water including all precautionary and safety measures complete all as specified and directed. |
| 20 | S&F in repairs 200 mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints laid in trenches or in floors including PCC bed and excavation in any type of soil and dismantling of pipe and bed of existing sewer line complete all as specified and directed. |
| 21 | S&F in repairs 150 mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints laid in trenches or in floors including PCC bed and excavation in any type of soil and dismantling of pipe and bed of existing sewer line complete all as specified and directed. |
| 22 | S&F in repairs 100 mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints laid in trenches or in floors including PCC bed and excavation in any type of soil and dismantling of pipe and bed of existing sewer line complete all as specified and directed. |
| 23 | S&F in repairs 75 mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed. |
| 24 | S&F UPVC (Sch-80) 150mm square euro guard rain water harvesting roof gutter pipe including bend, stopper all fitting including necessary form work and making good existing surface up to 10 mtr complete all as specified and directed. |
| 25 | S&F in repair 110 mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed on wall including taking down existing rain water pipe complete all as specified and directed. |
| 26 | S&F GI flat bands,straps, supports or stays for rain water , ventilating pipes including bolts if required hooks (stay) heavy for large gates, hook and pintle hinges, clamps, wall ties, plate washers and similar work complete all as specified and directed. |
| 27 | S&F 75mm PVC (SWR) bends any radius complete all as specified and directed. |
| 28 | S&F 110 mm PVC (SWR) bends any radius complete all as specified and directed. |
| 29 | S&F 150 mm PVC (SWR) bends any radius complete all as specified and directed. |
| 30 | S&F PVC floor trap 75mm with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B-1 with CP grating with ot without hole for waste pipe complete all as specified and directed. |
| 31 | S&F PVC (SWR) gully trap 125/110mm setting and jointed with cement solvent complete all as specified and directed. |
| 32 | Cleaning of Rainwater harvesting filter beds of size 0.9m x 0.9m x 0.9m and supply and refilling in three layers with 0.2m with hard core (size not exceeding 63mm and exceeding 40mm) and second layer of 0.2m with aggregates (10 to 20mm size) and third layer 0.2 m with washed M sand complete all as specified and as directed. |
| 33 | Cleaning of Rainwater gutter of size 150mm dia at the height upto 3.2m complete all as specified and as directed. Note : Cost of scaffoldings/stagings, safety measures are deemed to be included rate qutoed. |
| 34 | Cleaning of Rainwater gutter of size 150mm dia at the height upto 7.0m complete all as specified and as directed. Note : Cost of scaffoldings/stagings, safety measures are deemed to be included rate qutoed. |
| 35 | Cleaning of PVC water storage tank of capacity exc 250 Ltr but n.exc 500 ltr on roof or any position by disconnecting if required ,removing sludge,mud ,brushing ,rubbing and removing of alge if any and washing with bleaching powder and reconnecting /placing at its original position and writing date of cleaning complete all as specified and as directed. |
| 36 | Cleaning of PVC water storage tank of capacity exc 500 Ltr but n.exc 1000 ltr on roof or any position by disconnecting if required ,removing sludge,mud ,brushing ,rubbing and removing of alge if any and washing with bleaching powder and reconnecting /placing at its original position and writing date of cleaning complete all as specified and as directed. |
| 37 | Cleaning of PVC water storage tank of capacity exc 1000 Ltr but n.exc 5000 ltr on roof or any position by disconnecting if required ,removing sludge,mud ,brushing ,rubbing and removing of alge if any and washing with bleaching powder and reconnecting /placing at its original position and writing date of cleaning complete all as specified and as directed. |
| 38 | Rotational moulded polyethlene water storage tanks of capacity 2000 litres three layers (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete including 20mm dia ball brass valve high pressure with polythene float and dismantling of existing PVC tank complete all as specified and as directed. |
| 39 | Cleaning of open well including removal of sludge to a distance exc 50m but n exc 100 m complete all as specified and as directed. |
| 40 | Preparation of newly plastered surface of wall and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and as directed . |
| 41 | M&L for preparation old decorated painted surfaces of walls and applying one coat oil bond distumper complete all as specified and directed. |
| 42 | Complete removal of existing treatment and applying two coats of oil bound distemper over a coat of wall care putty not less than 1mm thick complete all as specified and directed. |
| 43 | M&L for preparation old decorated painted surfaces of ceiling and applying one coat oil bond distumper complete all as specified and directed. |
| 44 | M&L for preparation old decorated painted surfaces of walls and applying one coat of white wash complete all as specified and directed. |
| 45 | M&L for preparation old decorated painted surfaces of ceiling and applying one coat of white wash complete all as specified and directed. |
| 46 | M& L for Preparation of new plastered surface of wall and over a coat of wall care putty not less than 1 mm thick and making the surface smooth and applying two coat of oil emulsion distemper complete all as specified & directed. |
| 47 | M&L for preparation old decorated painted surfaces of walls and applying one coat exterior emulsion weather proof paint complete all as specified and directed. |
| 48 | M&L for Complete removal of existing treatment and applying two coats of exterior emulsion weather proof paint over a coat of cement based wall care putty not less than 1mm thick complete all as specified and directed. |
| 49 | M&L applying for exterior emulsion weather proof paint (Apex Ultima or equivalent) of any colour two coats over a coat primer, over a coat of cement based exterior putty not less than 1mm thick on newly plastered wall column projection, chajjas sides etc completely all as specified and directed. |
| 50 | M&L for one coat of synthetic enamel paint on steel surfaces of flag post 12mtr height including preparation of old surfaces over 10cm width or girth complete all as specified and directed. |
| 51 | M & L for complete removal of exisiting treatment on wall surfaces and applying damp proof coating in three layer treatement by applying first coat of Dr. fixit Dampguard classic followed by a coat of Dr. fixit Dampguard classic putty prepared by mixing 1 part of Damguard classic with 1 part of white cement (OPC) mixed so as to obtain consistency of a putty and finally applying second coat of Dr. fixit Dampguard classic, complete all as per manufacturers instructions, the treated surfaces shall be finished smooth and followed by two coats of distemper oil emulsion over a coat of alkali resistant primer, complete all as specified and directed. Note: Rate quoted is deemed to include for providing 104 Dampguard classic of Make Dr. Fixit completely in three layers including layer of putty, as per manufactures instruction upto the satisfaction of Engineer-in-Charge inorder to obtain desired finish and for arresting dampness completely. |
| 52 | Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 53 | M & L 75 mm thick PCC 1:4:8 type D 2 by using 40mm graded agregates, as in sub base complete all as specified and as directed |
| 54 | M & L 40 mm thick PCC 1:2:4 type B1 by using 20mm graded agregates, as in sub base complete all as specified and as directed |
| 55 | Dismantling of floor, hearth or wall tiling including cement mortar bedding & backing coat and rubbish off the premises complete all as specified and directed. |
| 56 | M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectengular) area of each tile exc 0.11 sqm but not exc 0.18 sqm in floors etc set and jointed in net cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 57 | M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectengular) area of each tile exc 0.18 sqm but not exc 0.36 sqm in floors etc set and jointed in net cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 58 | M&L Glazed ceramic coloured tiles in vertical surface 300x450x7mm/ 300x600x7 mm thick set and jointed in net cement slurry and pointed in white or colour cement to match over 10mm thick cement plaster in CM 1:4 complete all as specified and directed. |
| 59 | M&L 75 mm thick cement concrete 1:3:6 type C1 using 20 mm graded aggregate as in plinth protection finished fair and even with using extra cement complete all as specified and directed. |
| 60 | S&F in repairs 20 mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ ceilings/floors complete all as specified and as directed. |
| 61 | S&F in repairs 25 mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ ceilings/floors complete all as specified and as directed. |
| 62 | S&F in repairs 40 mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ ceilings/floors complete all as specified and as directed. |
| 63 | S&F in repair fancy type angle Stop cock CP cast copper alloy for 15 mm bore pipe , complete all as specified and directed. |
| 64 | S&F in repair fancy type Bib taps cast copper alloy chromium plated for 15 mm bore pipe, complete all as specified and directed. |
| 65 | S & F in repairs for pillar tap 15 mm bore chromium plated screwed down, high pressure screwed for iron pipe complete all as specified and directed. |
| 66 | S&F PVC waste pipe 32 mm dia, 750mm long suitable for kitchen/ WHB complete all as specified and as directed. |
| 67 | S&F PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 68 | S&F in repair 25 mm oore ball vallves nigh pressure of PTMT with epoxy coated Aluminium rod & high denisity plastic ball screwed for iron pipe and fixed complete all as specified and as directed. (Minimum weight 210 gms) |
| 69 | S&F in repair stop vlave 40 mm bore of PTMT any colour high pressure screwed for iron pipe and fixed (minimum weight 90 gms) complete all as specified and as directed. |
| 70 | S&F in repairs aluminium handles cast type anodised, size of handle 150mm complete all as specified and as directed. |
| 71 | S&F in repairs 150 mm aluminium , anodised, barrel tower bolt of extruded section complete all as specified and as directed. |
| 72 | S&F in repairs floor door stopper of aluminimum alloy body and tongue,, anodised with hard drawn steel spring fixed in floor, overall length of cover plat 140mm complete all as specified and as directed. |
| 73 | S&F in repairs 100mm size aluminium butt hinges, extruded alumigjum aloy with galvanised mild steèl hinge pin, anodised and fixed, type B-22 complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysSep 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender