Tender For Special Repair To Building No P-28 ‘A Vehicle Garage Of 1 Horse At Patiala Military Station
Tender Value
Ref. Documents
Estimated cost
Bid Submission
08 Sep 2026
15 days left
EMD
41540
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Patiala → Punjab
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repair To Building No P-28 ‘A Vehicle Garage Of 1 Horse At Patiala Military Station
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of brick work including all quoins archs pillars etc built in cement mortar complete all as specified. |
| 2 | M & L for brick work in cement mortar (1 : 6) using sub class 'B' bricks staight of curved on plan exc 6.0 m mean radius complete all as specified. |
| 3 | Demolition of cement concrete (un reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 4 | M&L for cement concrete (1:3:6) type B-1 using 20 mm graded stone aggregate 50mm thick, surfaces finished even and smooth without using extra cement as in plinth protection including forming joints and filling bitumenus mastic joint fillar grade 'A' form work to edges complete all as directed by Engr-in-Charge and complete as specified. |
| 5 | Taking down Cement plaster on brick or stone walls incl raking out joints hacking for key & scrubbing down with water etc compplete all as specified and directed. |
| 6 | Rendering 15mm thick on fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:4), using water proofing compound complete all as specified. NOTE:WPC will be measured and paid for separately |
| 7 | Supply only liquid water proofing comound ISI Marked complete all as specified and directed. . |
| 8 | M&L 10mm thick cement plastering in CM 1:6 on fair faces of brik work or concrete surfaces finished even & smooth without using extra cement complete all as specified and directed. |
| 9 | M&L 10mm thick cement plastering in CM 1:3 on fair faces of cocnrete ceiling surfaces finished even & smooth wihtout using extra cement complete all as specified and directed. |
| 10 | Material & labour for Preparation of plastered surfaces of walls and applying two coats of cement base paint and preperation of plastered surface, complete all as specified and directed by Engineer-in-Charge. |
| 11 | Material & labour for preparation of plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed by Engineer-in-Charge. |
| 12 | M&L for applying acrylic thick wall care putty on internal/external surfaces of walls/ceilings/soffits (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving painting etc complete all as specified and directed |
| 13 | Applying 02 coats of interior oil bound distemper (light shade) to wall surfaces over & including a coat of interior wall primer as recommended for under coat by manufacturer of OBD and primer complete all as specified and directed. |
| 14 | Supplying and applying two component elastomeric acrylic polymer modified cementitious waterproofing coating, SmartCare Damp Block 2K or approved equivalent, having 100% elongation as per ASTM D412, resisting 5 bars hyrostatic pressure as per DIN 1048, reduction to rapid chloride shall be 70 as per DIN 1048, crack bridging upto 1.2mm as per ASTM 4548.5. The coating shall have food grade certificate from laboratories like CFTRI. The mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing, etc., complete as per manufacturer specifications. Make of Chemical/Product : Sikka/Dr Fixit/Fosroc |
| 15 | Supply and apply cementitious coating for corrosion protection having a cement base polymer modified rebar corrosion protection system by applying the first coat approx 1mm thick layer of product carbonation resistance 2mm of sikatop ArmatecR -108 or equivalent as specified corresponds to 20 mm of normal mortar;bond strength 1N/mm2 according to ASTM C 882-78 applying @ 4kg/m2 for two coats onto the prepared reinforcing steel with a medium-stiff brush.it is unavoidable that specified product will also be applied in the same way after a waiting time of 2-3 hours (+20C) complete all as per manufacturers instructions and all as specified. Make of Chemical/Product : Sikka/Dr Fixit/FosrocNote: The application of cementitious coating for corrosion protection shall be got done through the authorised applicator of manufacturer of membrane only all as specified and directed. |
| 16 | Proving ,mixing & applying two components Epoxy resin concrete bonding coat on prepared RCC surfaces as per manufacturers apecification incl prepration of surface by chipping and throughly cleaning of surface complete wherever required and as per directions of Engineer-in-charge.Consumption: o.5 kg/m2 complete all as per manufacturers instructions and all as specified.Product requirements : complies with ASTM C 881 Type II Grade 2 class B+C. Make of Chemical/Product : Sikka/Dr Fixit/FosrocNote: The application of epoxy bonding primer shall be got done through the authorised applicator of manufacturer of membrane only all as specified and directed. |
| 17 | Supply and apply a pre-batched one component polymer modifies cementitious patch repair mortar in 25mm thickness.Yield:approx 0.84 ltr/kg.System requirements:compressive strength =50 N/mm2 (28 days)according to ASTM C 109 : flexural strength = 3 N/mm2 (7 days)according to ASTM C 293-79consumption of 2.1 kg/sqm/mm Make of Chemical/Product : Sikka/Dr Fixit/FosrocNote: The applicator of polymer repair mortar shall be got done through the authorised applicator of manufacturer of membrane only all as specified and directed. |
| 18 | Demolition of cement concrete (reinforced) in roofs, floors (other than ground floors) beams, slabs, staircases, landing, chajjas and similar suspended work complete all as specified and directed. |
| 19 | M&L for reinforced cement concrete nominal mix of type B-1 1:2:4 (20mm graded aggregates) for slabs supported on walls, beams, coloumn in floors,roofs,landings, balconies, canopies deck slab and shelves and the like complete all as specified and directed. |
| 20 | Use and waste of formwork to sides and soffits of slabs n. exc. 200 mm thick and similar works fair finished surfaces of concrete complete all as specified and directed. |
| 21 | S & F mild steel TMT bar 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, beam , slab etc hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clip complete all as specified and directed. |
| 22 | Dismantling of brick tiles or terracing tiles single layers on roofs complete all as specified and directed by Engineer-in-Charge. |
| 23 | Demolition of mud phuska on roof any thickness complete all as specified and directed by Engineer-in-Charge. |
| 24 | Roughening surfaces of old concrete floor/roof or brick surfaces by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified. |
| 25 | Plain cement concrete (1:3:6) type B-0, using 12.5 mm graded mechanically crushed stone aggregates as in padding to roof to maintain the required slope and finished the surface even and smooth without using extra cement, complete all as specified. |
| 26 | Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified. |
| 27 | Material & labour for Providing and laying 3mm thick APP (Atactic Polyproplene Polymer) APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) laid over and including bitumen primer @ 0.30 kg / sqm by forced application complete all as specified and directed by Engineer-in-Charge. |
| 28 | Applying 02 (Two) coats of bituminous Aluminum painting over and including a coat of primer over APP surfaces by using roller/brush as per manufacture's instructions complete all as specified and as directed by Enginner- in -Charge. |
| 29 | M & L for PCC 1:2:4, type B-0 using 12.5mm graded stone agg as in roof curve, benching, mud stops, steps, coping and the like items slightly rounded or chamfered on the edges complete all as specified and directed. |
| 30 | Material & labour for Repair to RCC sunshades, Chajjas, Balconies, Columns, bands, beams and similar RCC work at any position/height by dismantling loose/disintegrated portion and dubbing out with Cement Concrete 1:1½:3, 15mm to 50mm thick using 6 to 12mm graded stone aggregate to make up and finished to required shape including provision of necessary supports if required and stitching of cracks with mild steel U clamps made out of 8mm dia @ 150mm c/c with inserting concrete block stretcher with cement mortar 1:3 mixed with adhesive chemical (Polymer based) and reinforced with PVC chicken mesh including form work where ever required and finished with10 mm thick plastering in CM 1:4 finished even and fair without using extra cement including preparation of surfaces to receive finishes complete all as specified and directed. Make of Chemical/Product : Sikka/Dr Fixit/Fosroc |
| 31 | M& L for providing precast cement concrete 12.5mm graded aggregate (1:2:4) type B-0 in CM 1:4 for louvres and jallies, 25mm thick (measured solid), including all mould- ings but excluding frame (Pre cast frame shall be measured separately as specified and directed. |
| 32 | Taking down carefully existing points wiring on surface conduit/concealed conduit including conduit from surface and expect conduit in concealed wiring for light/fan/socket/power/bell from wall & roof along with fitting and fixtures such as switches, sockets, ceiling roses, batten holders, unserviceable light fittings, pieces of wires, gutties, conduit, wooden boards etc removing materials to store for keeping in safe custody of contractor for which the credit has been considered under schedule of credit and making good the disturbed portion of all floor, ceiling etc all as specified and directed. |
| 33 | Point wiring with 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper conductor for one light/fan/bell in new PVC conduit to be terminated in pressed steel terminal boxes with top cover plate including 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper earth continuity conductor controlled by one switch and/or one regulator complete including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified and directed by Engineer in-charge Note-I-(Switches and regulators shall be measured and paid for separately). Note-II- ( Wiring shall be done as per colour code in IS for phase, neutral and earth). Note-III- (The cost of modular cover plate and metal flush boxes is deemed to be included in the unit rate quoted for this item). Note -IV - cost of Eye/bottle thimbles used for connection in switches/sockets & MCBs in DBs is deemed to be included in the unit rate quoted for this item. Note:- V- Rate of cutting chasing included in the unit rate quoted for this item |
| 34 | All as per Sl item No 33.00 above herein before but one socket out let 5 pins 5 Amp on the same board with other switches complete all as specified and directed. |
| 35 | All as per Sl item No 33.00 above herein before but for one socket out let 5 pins 5 Amp on independent board complete all as specified and directed. |
| 36 | All as per item No. 33.00 herein before but 2.5 Sqmm PVC insulated and unsheathed FRLSH single core multistranded copper conductor incl 2.5 Sqmm PVC insulated and unsheathed FRLSH copper earth wire for switch socket combination 3 pin 15 amps on independent board. |
| 37 | Supply & fix in replacement of Modular switch 1 way, 6 Amps, 1 module, 230 volts complete all as specified. |
| 38 | Supply & fix in replacement of Modular switch 1 way, 16 Amps, 1 module, 230 volts complete all as specified. |
| 39 | Supply & fix in replacement of Modular socket 5 pin 6 Amps, 2 module 230 volts complete all as specified. |
| 40 | Supply & fix in replacement of Modular socket 5 pin 6 &16 Amps, combination type 2 module complete all as specified. |
| 41 | S&F ceiling rose surface bakelite surface 65 x 50mm 3 terminals all as specified & directed |
| 42 | Lamp holder including LED bulb 9 W including flexible wire 0.5 Sqmm copper cable all as specified & directed by Engr-in-charge. |
| 43 | New generation energy saving and environmental friendly long life LED building security light 1x35 watts made up of pressure die cast alluminium housing with high power LED as light source and lense embedded PC cover having TOP OPENING separate driver compartment with IP65 protection and impact resistance of IK07, with all accessories including suitable bracket with 32mm bore light grade GI pipe bemd to shape, including MS clamp of size of required size and PVC cable 1.5 Sqmm twincore from ceiling rose to light fittings complete all as specified and directed by Engineer-in-charge. |
| 44 | M & L for Sub main wiring with two single core 6.0 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia including 6.0 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note 1:-2(two) Runs of 6.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 6.00 Sqm Copper conductor Earth wire shall be measured as one unit) Note 2 :(i) Rate quoted for this items shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of 25 mm dia with tees, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. (ii) Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to match the existing surfaces and cutting not exc. 10 cm girth . (iii) Including taking out/down existing unserviceable sub main wiring. |
| 45 | MCCB, 4 Pole, 100 A, 16 KA for fixing in DB including proper thimble connection, thermal and magnetic release protection complete all as specified and directed by Engineer-in-charge. |
| 46 | Supply and fix epoxy power coated MCCB distribution box double door VTPN 4 way vertical type AC 415 V with IP 43 protection for MCBs alongwith provision of MCCB as incomer with commen bus-bar at incoming end of outgoing MCBs grouted/ flush to wall, complete all as specified by Engineer-in-charge. (Note :- MCCB will be measured and paid under seperate item) (i) Cost of Eye/bottle thimbles used for connection MCBs in DBs shall deemed to be included in unit rate quoted for this items, (ii) Electric wiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth. (iii) connection of theMCCBs/ MCBs with cable shall be made through appropriate size pin /bottle type thimble -properly crimped. all the vacant holes of the DB shall be provided with blank plates of appropriate size. |
| 47 | Supply and fix Sheet metal enclosure 8 ways double door for DBs when MCBs are to be used 240,volts including 200 Amps standard bus bar of suitable size and common neutral link all flush mounting type, drilling holes for incoming and out going cables with IP 43 protection complete all as specified & directed by Engr-in-charge. |
| 48 | Supply and fix MCB , SPN, 240 Volts ,32-40 amp for fixing in DBs of including proper thimble connections complete all as specified and directed by Engineer-in-Charge. |
| 49 | Supply and fix MCB, single pole 240 volts 6 to 32 Amp capacity for fixing in DB’s including proper thimble connections complete all as specified and directed by Engineer-in-Charge. |
| 50 | M & L for Earthing complete with galvanized iron earth plate electrode of size 600x600x6.0mm , buried directly in ground (earth pit not less than 2.25 mtrs below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanized earth lead wire 4.0 mm dia by means of bolts , nuts , check nuts and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate 20 mm dia watering pipe medium grade 1.70 mtr long with a plug at top, GI protection pipe light grade 15 mm dia from earth pit to main board including PCC pit in cement concrete 1:2:4 along with CI frame and cover 10mm thick duly hinged to CI frame as shown in the electrical plate No3 of SSR 2009 part 1 specification at page 497. |
| 51 | Supply and fix Tube light fitting Self Ballasted LED Batten. Extruded Thermoplastic body with PC Diffuser in square LED Batten 18/20W 6500K of capacity ,20 watt,4 ft long incl 3 core flexible wire 0.5 sqmm copper cable all as specified and directed by Engr-in-charge. |
| 52 | S & F INDUSTRIAL HIGH BAY LED light of capacity 80 W ,The LED make must be of minimum 100 lumen/ watt .The driver must be power factor > 0.95 with short circuit protection , open circuit protection, reverse polarity protection, high voltage protection. the luminaire must have secondary optics with perfectly matched lens for better light control with CMRI approved correleted color temperature (CCT) of Emitting light 5700 K with with die cast aluminium housing with heat resistant toughened glass IP 66 protection comlete with control gear box and all accessories require to fix the light on wall/structure/pole like clamps nus, bolts et cwith suitable size and including connecting up with twin core twisted flexible copper conductor cable 1.5x2 sqmm with proper clamps. complete all as specified and directed by Engr in Charge. |
| 53 | S&F industrial type heavy duty wall mounting fan made of steel body air circulator 600MM sweep, 220 watt motor, 1440 RPM air delivery 16200 CMM single phase AC 230 V, 50 Hz, supply all as specified and as directed. Note- The new clamp/any fixng item required during installation of wall mounted fan is included in this item. |
| 54 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cables including getting out in any kind of soil complete all as specified and directed. |
| 55 | Returning filling in including spreading, levelling, and well ramming, in layers not exceeding 25 cm thick each layer of any kind of soil. |
| 56 | Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point. |
| 57 | Material and labour for sand cushioning for cables 8 cm below the cable and 15 cm above with dry river sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming completed all as specified and directed. |
| 58 | Cutting of hardstanding floor/wall for laying of cable including matching with suface by using cement concrete 1:2:4 type B-0 all as specified and directed. |
| 59 | M&L for Boring of holes under road, pavement, hard standing by trench-less technology using ultrasound technique and necessary machine suitable to pass through 40 to 80 mm bore GI tubing and cable etc complete all as specified and directed.Note: GI pipe shall be measured and paid seperately under relevant item. |
| 60 | Supplying & laying factory made unreinforced Precast concrete cable covers class LV type 1, flat, Size 250x150x40mm laid in trenches as protection to cables complete all as directed by Engr-in-Charge |
| 61 | Material and labour for replacement of GI tubing light grade 40 mm bore for passing through cables under the floor ,along the wall or along the pole complete all as specified and directed. |
| 62 | XLPE Insulated ,screened, PVC bedded, galvanized steel wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core supplied & laid in replacement complete all as specified& directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysSep 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender