Tender For Repair, Maintenance Of 11 Kv Transformer And Ht Pole Repair, Replacement Of God, Mccb And Connected Accessories Under Ge (N) Ahilyanagar
Tender Value
75.13 Lakhs
Estimated cost
Bid Submission
15 Sep 2026
22 days left
EMD
1.38 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ahmednagar → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair, Maintenance Of 11 Kv Transformer And Ht Pole Repair, Replacement Of God, Mccb And Connected Accessories Under Ge (N) Ahilyanagar
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exc 1.5 metre wide and not exc. 1.5 mtr in depth for laying of under ground cable, pole foundation and stays etc and getting out in soft / loose soil all as specified and as directed |
| 2 | Excavation in trenches not exc 1.5 metre wide, exe 1.5m depth and n.exc 3 m deep and getting out in any type of soil for laying of cable complete all as specified and directed by Engineer-in-charge. |
| 3 | Returning and filling in, including spreading and levelling, water and well remming in layers not exc. 25cm all as specified and directed. |
| 4 | Removing excavated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed. |
| 5 | Supply, laying, testing & commissioning of HT 11 KV (Earthed) XLPE insulated screened PVC bedded, electric power cable (heavy duty) ISI marked with aluminium conductor 11000 volts grade, circular screened with extruded semi conducting compound in combination with copper tape, inner sheath of PVC tape galvanized steel strip flat, around and overall PVC sheathed, armoured conforming to IS 7098 Part II, 1985 amended upto date, of size 3 core 95 Sqmm, ISI marked, laid in trenches or passing through pipes/ducts including taking down old cable of any size all as specified and as directed. |
| 6 | Supply, laying, testing & commissioning of HT 11 KV (Earthed) XLPE insulated screened PVC bedded, electric power cable (heavy duty) ISI marked with aluminium conductor 11000 volts grade,circular screened with extruded semi conducting compound in combination with copper tape, inner sheath of PVC tape galvanized steel strip flat, around and overall PVC sheathed, armoured conforming to IS 7098 Part II, 1985 amended upto date, of size 3 core 120 Sqmm, ISI marked, laid in trenches or passing through pipes/ducts including taking down old cable of any size all as specified and as directed. |
| 7 | Supply, laying, testing & commissioning of HT 11 KV (Earthed) XLPE insulated screened PVC bedded, electric power cable (heavy duty) ISI marked with aluminium conductor 11000 volts grade,circular screened with extruded semi conducting compound in combination with copper tape, inner sheath of PVC tape galvanized steel strip flat, around and overall PVC sheathed, armoured conforming to IS 7098 Part II, 1985 amended upto date, of size 3 core 150 Sqmm, ISI marked, laid in trenches or passing through pipes/ducts including taking down old cable of any size all as specified and as directed. |
| 8 | Notes for ser item No. 5, 6 & 7 :- 1. Excavation and earthwork, sand cushioning , GI pipe, cable protection will be measured and paid for separately 2. Cable shall be tested at high voltage test before & after laying. 3. No straight through joint will be permitted inside pipe or duct. 4. Cost of straight through if any deemed to be included in cost of cable. |
| 9 | Supply & laying of heavy duty HDPE DWC pipe for HT cable pipe ISI marked of outer dia 110 mm and Inner dia 95 mm polythylene with smooth internal and external surface for non pressure under ground cable icluding coupler and bends complete all as specified and directed Make : Supreme/Finolex/Prince/Jain |
| 10 | Supply and fix in repairs on load change over switch existing panel, wall or LT pole of any size, triple pole and neutral, 400 Amps, 415 V, 50 Hz front handle operated, including connecting and testing all as directed. |
| 11 | Supply and fix in repairs on load change over switch existing panel, wall or LT pole of any size, triple pole and neutral, 200 Amps, 415 V, 50 Hz front handle operated, including connecting and testing all as directed. |
| 12 | Supply and fixing in existing panel board for replacement MCCB, 4 Pole, 400 Amps, with breaking capacity 36 KA, fixed type (HBC Series), adjustable type thermal setting 70-100% and magnetic adjustable 5-10 times AC 415 volt, 50 HZ conforming to IEC:60947-II/IS:13947-II and connecting all as directed. |
| 13 | Supply and fixing in existing panel board for replacement MCCB, 4 Pole, 315 Amps, with breaking capacity 36 KA, fixed type (HBC Series), adjustable type thermal setting 70-100% and magnetic adjustable 5-10 times AC 415 volt, 50 HZ conforming to IEC:60947-II/IS:13947-II and connecting all as directed. |
| 14 | Supply and fixing in existing panel board for replacement MCCB, 4 Pole, 250 Amps, with breaking capacity 36 KA, fixed type (HBC Series), adjustable type thermal setting 70-100% and magnetic adjustable 5-10 times AC 415 volt, 50 HZ conforming to IEC:60947-II/IS:13947-II and connecting all as directed. |
| 15 | Supply and fixing in existing panel board for replacement MCCB, 4 Pole, 200 Amps, with breaking capacity 36 KA, fixed type (HBC Series), adjustable type thermal setting 70-100% and magnetic adjustable 5-10 times AC 415 volt, 50 HZ conforming to IEC:60947-II/IS:13947-II and connecting all as directed. |
| 16 | Supply and fixing in existing panel board for replacement MCCB, 4 Pole, 160 Amps, with breaking capacity 36 KA, fixed type (HBC Series), adjustable type thermal setting 70-100% and magnetic adjustable 5-10 times AC 415 volt, 50 HZ conforming to IEC:60947-II/IS:13947-II and connecting all as directed. |
| 17 | Material and labour for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick, buried vertically in ground (Each pit not less than 2.25 mtrs deep below normal ground level with top edge of plate not less than 1.50 M below normal ground level) connected to GI strip 32 x 6 mm by means of bolts, nuts and check nuts and washers etc encased in GI protection pipe 40 mm dia light grade pipe for protection of GI earth strip both to be provided to the extet of 7.5 meters, all as shown on electrical plate No 3 of MES SSR - 2004 Part - I, GI protection pipe buried in ground, laid under floors / plinths or mixed on walls / pole etc or concealed in walls etc; with provision of mixture of charcoal dust and common salt packed upto minimum 150 mm all around the earth plate, including PCC 1:2:4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with GI 20 mm dia medium grade pipe and MS funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of soil / strata and testing on completion complete all as specified and directed. |
| 18 | S&F in replcement of vertical type air break switch, gang operated, triple pole, mechnically operated, outdoor type, with all fittings and accessories mounted on and including HT 11 KV porcelain insulators and steel channel frame, GI operating rod 25 mm dia of suitable length to worked from ground, including locking arrangements , suitable for 11000 volts, 400 Amps current rating complete including dismantling existing one all as specified and as directed. |
| 19 | S&F Drop out fuse unit, explusion type for out door air break gang oprated switch, single pole mounted on and including insulators for 11 KV working pressure fixed to and including MS channel with nuts, bolts and washer etc synthetic bounded fuse tube complete with line capacity suitable for current carrying capacity upto 100 Amps all as directed including taking down old one all as specified and as directed |
| 20 | S&F in replacement of HT 11 KV out door non-linear type lightning arrestor with mountings, accessories complete fixed on cross arms of two pole structure / GI flat strip and connect with same size of ACSR conductor encashed in PVC alkathine pipe with all fittings connected to earth strip with nuts, bolts and washers, transmission class having discharge capacity of 10 KA and suitable for working pressure 9 KV RMS compelete including taking down old lightning arrestor all as specified and as directed including dismantling existing one all as specified and as directed. |
| 21 | M&L for cable jointing kit for 11 KV grade cable for straight through heat shrinkable joint suitable for XLPE armoured aluminium conductor cable of size 3 core 95 Sqmm all as specified and directed. Make: Denson/ M Seal/Siemens |
| 22 | M&L for cable jointing kit for 11 KV grade cable for straight through heat shrinkable joint suitable for XLPE armoured aluminium conductor cable of size 3 core 120 to 150 Sqmm all as specified and directed. Make: Denson/ M Seal/Siemens |
| 23 | M&L for end termination cable jointing kit for 11 KV grade cable heat shrinkable joint, out door suitable for XLPE armoured aluminium conductor cable complete with jointing materials and accessories suitable for 3 core 120 to 185 Sqmm all as specified and directed. Make: Denson/M Seal/Siemens/Cabsil |
| 24 | M&L for end termination cable jointing kit for 11 KV grade cable heat shrinkable joint, out door suitable for XLPE armoured aluminium conductor cable complete with jointing materials and accessories suitable for 3 core 95 Sqmm all as specified and directed. Make: Denson/M Seal/Siemens/Cabsil |
| 25 | M&L for end termination cable jointing kit for 11 KV grade cable heat shrinkable joint, out door suitable for XLPE armoured aluminium conductor cable complete with jointing materials and accessories suitable for 3 core 120 Sqmm all as specified and directed. Make: Denson/M Seal/Siemens/Cabsil |
| 26 | Supply, erecting and fixing in true vertical position of steel tubular swaged pole, 11 mtr long complete with cast iron base plate, finial taper plug, bolt, nuts and screws as specified and of type 410 SP-55, conforming to relevant IS, including one primer coat of red oxide and two coats of aluminium paint and two coats of bituminous paint inside and outside of bottom portion up to 1.8 mtr length all as specified and provide circular bend 1 No of width 2 cm complete all as specified and directed. (Excavation and earth work , foundation concrete and PCC coping shall be measured and paid separately) |
| 27 | M&L for cement concrete (1:4:8 ) type D2 using graded stone aggregate as in foundation for pole including necessary form work all as specified & directed. |
| 28 | M&L cement concrete (1:3:6 ) type C1 using graded stone aggregate as in foundation for pole including necessary form work all as specified & directed. |
| 29 | M & L for PCC(1:2:4) type B1 using 20mm grade stone aggregates for coping and similar work all as specified and directed. |
| 30 | Demolition of cement concrete in copings etc complete all as specified and directed by Engineer-in-Charge. |
| 31 | Repair / Maint of air break switch by replacing stationary and moving contacts, flexible copper chord, GI nuts, bolts etc including alingment for smooth functioning from ground level all as required at site and all as specified & directed. Please Enable Macros to View BoQ information |
| 32 | Repair / Maint of air break switch by replacing stationary and moving contacts, flexible copper chord, GI nuts, bolts etc including alingment for smooth functioning from ground level all as required at site and all as specified & directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 15, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 22 daysSep 22, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 29 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender