Housing Urban and Rular Development Local Bodies Closing in 10 days TDR #57072969

Tender For Modernization/Upgradation Of Existing Parks/Green Belts.Sh: Supply Installation Testing and Commissioning of 4 Mtr. Gi Poles Along With 45-Watt Led Street Lights And Accessories Including Panel Etc. At Dda Green Land Behind Pocket-11, Sect

Issued by Local Bodies · Delhi, Delhi
Tender Value
46.71 Lakhs
Estimated cost
Bid Submission
29 Aug 2026
10 days left
EMD
93426
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Modernization/Upgradation Of Existing Parks/Green Belts.Sh: Supply Installation Testing and Commissioning of 4 Mtr. Gi Poles Along With 45-Watt Led Street Lights And Accessories Including Panel Etc. At Dda Green Land Behind Pocket-11, Sector-23, Rohini Under Hd-5.

BOQ

Name of Work:- Modernization/Upgradation of Existing Parks/Green Belts.SH: SITC of 4 mtr. GI Poles along with 45-Watt LED Street Lights and accessories including Panel etc. at DDA Green Land behind Pocket-11, Sector-23, Rohini under HD-5.
Sl. No. Item Description
1Supplying, Fabrication and Installation of 4 mtr. High Pole made out of 65 mm dia. NB, B-class GI Pipe ISI marked duly welded with MS Base Plate of size 300 mm x 300 mm x 12 mm thick with stiffener of size 130 mm x 60 mm x 5 mm thick; top edge to be blunted (No Sharp Edge), suitable Earth Stud on Base Plate, making suitable size hole in Pole at a Height of 2.5 meter from Base Plate for Cable entry/exit, Painting & Numbering of Pole, making suitable size hole in Base Plate for Cable entry/exit into the Pole and Fixing the Pole on the Existing Foundation with the existing nuts-bolts, washers etc. complete as required.
2Supplying and Fixing of Single Over Hang (SOH) Bracket- for 50-80 dia. MS/GI Pole made of MS Pipe with 300 mm long MS Tube of suitable diameter for Light Fitting accommodation, connection etc. complete as required.
3Supplying and Fixing of Double Over Hang (DOH) Bracket- for 50-80 dia. MS/GI Pole made of MS Pipe with 300 mm long MS Tube of suitable diameter for Light Fitting accommodation (Angle as per EIC/AE direction).
4SITC of 500 mm Gate Bollard made out of dia. 165 mm GI Pipe with PC Diffuser for Glare Free Lighting suitable for 12-W LED Lamp suitable for B‐22d Lamp Holder i/c Supply and Fixing of suitable mounting accessories (Like Bracket/Nut-bolts etc.) & suitable size Wiremesh complete as required.
5Supplying, Installation, Testing & Commissioning of Street Light LED Fixture Powder Coated Pressure Die Cast Aluminum body with driver as per the requirement with Driver Efficiency>85%, Input voltage: 140-270 Volt AC, Frequency 50/60 Hz, Operating Temp range-5°C to 50°C, Internal Surge Protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency>85%, THD<10% as per IEC 61000-3-2 , PF≥0.95, IP- 66, IK-10, CRI>70, Under Voltage and Over Voltage Protection, EMI-EMC As per CISPR 15, Lenses for Beam Angle as per IESNA type I/II/III as per the width of the road and the project requirement, suitable to fit in up to 65 mm dia. pipe, life time (LED, Driver & Electrical Circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K/4000°K/5700°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching)<5, Maximum Power Consumption should not more than the specified rating and Fixture shall be of relevant BIS Standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC Insulated Copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System Lumen Efficacy≥120<135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED Fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal Management: Heat Sink of Aluminum Housing such that LED Junction Temperature shall not rise above 90°C).45 Watt
6Supply & Installation of Pole Connector Box made out of Glass Reinforced Polyester Sheet Moulding Compound Conforming to IS:13410-1992 Grade-S1 of Outside Dimensions 280 mm (H) x 170 mm (W) x 115 mm (D) (all the corners of the box should be round & not pointed ones) suitable to mount on 40/50/65/80 mm dia. GI Pole with the following Provisions/Accessories mounting in Box etc. complete as required.a) 2 Nos. Clamps made out of 19 mm x 3 mm GI Strip of suitable Length for Mounting Box on the Pole.b) Water Tight Front Cover with 2 Nos. Stainless Steel Hinges & 1 No. Screw for Tightening.c) 4-Way, 220 V, 30 A, Dough Moulded Connector with SMC with Stainless Steel Inserts- 1 No.d) 16 A, Moulded SMC Rewireable Kit-Kat- 1 No.e) Suitable size Hole at suitable Location on Rear Wall for Cable & Wire Entry in the Connector Box.f) Earthing Bolt M6 x 20 mm.g) Neutral Link- 1 No.
7Providing and Laying in Position, 1:2:4 (1 Cement : 2 Coarse sand : 4 Graded Stone Aggregate) Reinforced Cement Concrete Foundation of size 450 mm x 450 mm x 1200 mm deep (900 mm below Ground Level and 300 mm above Ground Level) including excavation of earth, refilling, providing, cutting, bending and placing in position, Reinforcement of Cold Twisted Bars of 12 mm dia.- 1200 mm long (approx.)- 8 Nos. and Reinforcement Ring of Cold Twisted Bar of 8 mm dia.- 1400 mm long (approx.)- 6 Nos. (with suitable spacing) including centering & shuttering as required with Providing, Fixing and Positioning of One Set of Foundation Bolts comprising of 4 Nos., 16 mm dia. 750 mm long J-Type MS bolts (Threaded portion shall be galvanized) along with 3 Nos. GI nuts and 2 Nos. GI washers etc. per bolt and 1 No. anchor plate (3 mm thick) of suitable size and providing 63 mm (OD) DWC pipe ISI marked for cable entry & exit and foundation should be finished with neat cement punning technique on the exposed portion of foundation complete. as required.
8Supplying of following sizes of XLPE (Cross Linked Poly Ethylene) Insulated PVC Sheathed Alumimium Conductor Armoured Power Cable of 1.1 KV grade including connection, testing etc. as required.2C x 16 sq. mm
94C x 25 sq. mm
10Providing and Fixing 6 SWG dia. GI wire on surface or in recess for loop earthing along with existing surface/recessed conduit/sub-main wiring/cable as required.
11Supplying and Laying of following size DWC HDPE Pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS: 14930, Part-II complete with fitting and cutting, jointing etc. direct-in-ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia. (OD-63 mm & ID-51 mm nominal)
12Laying of one number PVC Insulated and PVC Sheathed/XLPE Power Cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL Pipe as required.Up to 35 sq. mm
13Supplying and drawing of following sizes FRLS PVC Insulated Copper Conductor, Single Core Cable in the existing surface/recess steel/PVC conduit as required.3C x 1.5 sq.mm
14SITC of Floor Mounted LT Feeder Pillar Cubical type Double Door of size 1000 mm x 900 mm x 300 mm deep duly compartmentalized and with general arrangement made out of 2 mm thick CRCA Sheet having hinged gasket cover and screwed knobs with double locking arrangement and rain protection covers 100 mm and supported with MS Angle Iron legs and bottom frame of size 35 mm x 35 mm x 5 mm x 1 mtr. long grouted with 1:3:6 CC Foundation and should be 0.7 mtr. above ground level. Legs should be covered with brick walls, duly 1:4 cement plaster, connections, inter connections with suitable size of FRLS PVC insulated copper conductor using thimbles, ferrules wherever required, painting, numbering including supply and fixing of following accessories complete etc. as required (as per drawing approved by Engineer-in-Charge).a) 100 A, 30 kA, 4 Pole MCCB (‘C’-Series)- 1 No. (Incomer).b) 6 A to 32 A ratings, SP MCB, “C” curve, 10 KA breaking capacity- 6 Nos.c) 6 A to 32 A ratings, DP MCB, “C” curve, 10 KA breaking capacity- 1 No.d) Analogue Timer Switch for daily operation and Toggle Switch for Auto/Manual- 1 No.e) 3-Pole Power Contactor of AC3 Rating 32 Amp- 1 No.f) 30 Amp, 4-Way Neutral Link/Connector- 2 Nos.g) Voltmeter (0-500 V) 96 mm x 96 mm Square type with Selector Switch- 1 No.h) Ammeter (0-30 A) 96 mm x 96 mm Square type- 1 No.i) Phase Indication Lamp (RYB) with Fuses- 1 Set.j) Danger Notice Plate- 1 No.k) 200 A, 4-Strip Al. Bus-Bar of minimum 300 mm long with sleeve and nut-bolts- 1 Set.l) Lifting Hook on the Top of Panel Board and Lighting arrangement inside the Feeder Pillar- 1 No.
15Supplying, Fabrication and Installation of Wire Mesh Protection Frame for Existing Feeder Pillar, constructed from 10 SWG MS wire mesh with a Nominal size of 75 mm x 25 mm Rectangle. The Frame dimensions are 1.5 mtr. (Width) x 1.00 mtr. (Depth) x 2.00 mtr. (Height). It includes a Base Frame made of 40 mm x 40 mm x 6 mm MS Angle Iron, MS Strip Supports of 40 mm x 6 mm, and 0.5-meter-long leg supports of the same Angle Iron, all as per the approved drawing. Additionally, provide a suitably sized door, Supply and Fix a godown lock with locking arrangement, painting, and grouting with 1:2:4 Cement Concrete Foundation, as approved by the Engineer-in-Charge, complete as required.
16Earthing with GI Earth Pipe 4.5 meter long, 40 mm dia. including accessories, and Providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
17Providing and Fixing 25 mm x 5 mm GI Strip on surface or in recess for connection etc. as required.
18Providing & Laying of DWC HDPE Pipe of size 63 mm Outer dia. by Trenchless Technology with No Dig Method by making Bore Hole in Horizontal direction across the Road/Path with Boring equipment i/c jointing/cleaning of Pipes, excavation of pits of required size & depth etc. complete as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57072969
AUTHORITY Local Bodies
TENDER VALUE 46.71 Lakhs
LAST DATE 29-08-2026
Authority
Authority Name Delhi Development Authority
Work Description Tender for Modernization/Upgradation Of Existing Parks/Green Belts.Sh: Supply Installation Testing and Commissioning of 4 Mtr. Gi Poles Along With 45-Watt Led Street Lights And Accessories Including Panel Etc. At Dda Green Land Behind Pocket-11, Sector-23, Rohini Under Hd-5.
Basic Detail
Tender No 35/EE(E)/ELD-12/DDA/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 18 Aug 2026
Submission Date 29 Aug 2026
Open Date 31 Aug 2026
Finance
Tender Value 46.71 Lakhs
Tender Fee Ref. Documents
EMD 93426
Exemption Available
Document List
16c4a76f-7bcb-4381-b95d-3984056ef2be.html
BOQ_969523.xls
NIT35.pdf
PressNotice35.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Aug 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
html

16c4a76f-7bcb-4381-b95d-3984056ef2be.html

xls

BOQ_969523.xls

pdf

NIT35.pdf

pdf

PressNotice35.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders