Tender For Installation Of Plug Point For Vc Set Up In Every Court At Malda Sadar, Chanchal Subdivision And Juvenile Justice Board, Malda. (Job No. 07 / M / Ow Of 2026 - 27).
Tender Overview
Project Description
Tender for Installation Of Plug Point For Vc Set Up In Every Court At Malda Sadar, Chanchal Subdivision And Juvenile Justice Board, Malda. (Job No. 07 / M / Ow Of 2026 - 27).
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 18-Aug-2026 | BOQ | BOQ | 31-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Supply, Installation, Testing, and Commissioning of air-cooled Hi-Wall split type air conditioners of following capacities comprising Indoor and Outdoor Units with factory-charged Rotary/Scroll compressors (R-32/R-410A) including surface/concealed copper refrigerant piping insulated with closed-cell elastomeric nitrile rubber insulation and wrapping tape (up to 3 m), FRLS type copper power cable (up to 3.5 m) with suitable plug top, 3 meters of drain pipe, and wireless remote control with suitable battery. The system shall operate on 230V, 50Hz (±tolerance as per applicable standard), single-phase AC supply, providing cooling, dehumidification, and air circulation functions conforming to IS-1391 (Part-II ) with all amendments, and shall be capable of efficient performance at outdoor ambient temperatures up to 50°C, with a minimum 5- year OEM warranty on both the compressor and PCB. The system shall be installed with S&F appropriate fixing arrangements as per OEM recommendations, including wall openings, mending well the damages and making necessary connections including T&P & labour etc as required complete in all respect as per the direction of EIC. (O-General/Mitsubishi Electric) |
| 2 | Cooling Capacity- 5.2 kW (Minimum) , Air Flow Rate:600 CFM (Minimum) Minimum ISEER - 5.0, BEE level - 4-Star(min) |
| 3 | Cooling Capacity- 6.1 kW (Minimum) , Air Flow Rate:800 CFM (Minimum) Minimum ISEER - 5.0, BEE level - 4-Star(min) |
| 4 | Supplying, Installation, testing and commissioning including ccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, ointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : |
| 5 | 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 6 | 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 7 | S&F of additional following items for length exceeding 3.5 mtr for complete installation and commissioning of aboove AC machines.i) 2.5 sqmm, 3/4 core copper cable (FRLS type) |
| 8 | Supply & laying Soft Drawn PVC Drain Pipe 19mm dia with proper supports & brackets as per direction EIC. |
| 9 | Supply of 7ft long and 3ft width 25x25x6 mm Iron angle frame and 19x6mm Iron Flat dully fabricated by skilled welder & fixing the same after making holes into wall also supply & Fixing of 19 mm thick water proof plywood with necessary fixing meterials for installation of indoor unit of Split AC. |
| 10 | Supply & Fixing of 19 mm thick 1200mm x320mm water proff Plywood on HW block for installation of indoor unit of 1.5 Tr. Split AC machine as required.(Make:-Century Ply) |
| 11 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 12 | Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections. |
| 13 | Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 14 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required |
| 15 | 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC |
| 16 | 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC |
| 17 | Supplying and delivery of following size Armoured cables XLPE/PVC insulated are designed for 1.1 kV Stranded Aluminium conductor, high tensile galvanized steel wire/strip armour for mechanical protection, and PVC/FR PVC outer sheathing power cable of following size. (IS 7098 Part - 1/2011 with Up To Date Amendments.) (Polycab / Havells / KEI). |
| 18 | 2 core 6 sqmm |
| 19 | Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting |
| 20 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below |
| 21 | 2 core 6 sqmm |
| 22 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials |
| 23 | 2 core 6 sqmm |
| 24 | Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint |
| 25 | Supply and Fixing 240 V 10W LED bulk head ceiling fitting on wall /ceiling by screws etc. [Make- Crompton, (RIGEL) Model-TIS-303-10-57-SL-DP-NWH / Philips/Havells] |
| 26 | Supply & Erection of 1.5m long pole 80mm dia GI pipe pole with base plate & pole cap Providing CC (6:3:1) muffing 600x600x760 mm in size or equivalent size of cylindrical muffing above ground level /roof top around the pole base complete with 3 mm thick neatly finished cement plaster all round after dismantling the unserviceable muffing if any incl. painting and making earth bolt washer and G.I. earth bolt on plate as to G.S. with out loop box |
| 27 | Supply and Fixing CMDA type Non-detachable 40mm dia(14SWG) 1.5mtr long arm bracket at an angle10 degree to horizontal with necy bolts nuts etc incl. pinting two coats of Al paint over one coat of RO primer as per GS and as per direction od EIC. |
| 28 | Supplying, installation, Testing & Commissioning of Street light LED ixture powder coated pressure die cast aluminum body finish with orrosion resistance fasteners (SS hardware) & silicon gasket for proper sealing with driver as per the requirement with Driver efficiency >80%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range 0º to 50º C and working RH 10% - 90%, internal surge protection of 5 KV internal and external SPD min. 10 KV, L,N,E as per IEC 61000-4-5. The driver rated output wattage should be 10% to 15% higher than lamp rating and at least 2 driver for 200W & above and Driver efficiency >85%, THD < 10% as per IEC 61000-3-2 , P. F.≥0.9, IP- 66, IK-08 specified below, CRI >70, under voltage and over voltage protection, high efficiency lens with type II/III distribution as required with UV stabilized optical lens, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours (Life projection shall be calculated as per TM-21 methodology) and 70% of initial Lumen maintained till life ends. CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect and LED Chips of SMD mid to high-power (2.5 to 4 watt for 200 watt above, as per required (LM- 80 tested) and inter-connections with 1.5 sq mm FR, PVC insulated Cu. Conductor. System lumen efficacy ≥135 lm/Watt. |
| 29 | 150 W |
| 30 | Supplying, installation, Testing & Commissioning of Flood light LED fixture powder coated pressure die cast aluminum body finish with corrosion resistance fasteners (SS hardware) & silicon gasket for proper sealing with driver as per the requirement with Driver efficiency >80%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range 0o to 50o C and working RH 10% - 90%, internal surge protection of 5 KV internal and external SPD min. 10 KV, L,N,E as per IEC 61000-4-5. The driver rated output wattage should be 10% to 15% higher than lamp rating and at least 2 driver for 200W & above and Driver efficiency >85%, THD < 10% as per IEC 61000-3-2 , P. F.≥0.9, IP- 66, IK-08 specified below, CRI >70, under voltage and over voltage protection, high efficiency lens with type II/III distribution as required with UV stabilized optical lens, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours (Life projection shall be calculated as per TM-21 methodology) and70% of initial Lumen maintained till life ends. CCT 3000°K / 4000°K /5700°K /6000°K/6500°K, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect and LED Chips of SMD mid to high-power (2.5 to 4 watt for 200 watt and above, as per required (LM- 80 tested) and inter-connections with 1.5 sq mm FR, PVC insulated Cu. conductor. System lumen efficacy ≥135 <135 lm/Watt |
| 31 | 50 Watt |
| 32 | S & F of Timer Switch comprising of 40A DP MCB (Make: L&T / Legrand / Seimens) as incomer & 1 Channel digital astronomical timer switch (Make: L&T, Cat. No. - T2DDT7 or equivalent model of Legrand / Seimens) with 1 No. 25A Modular Contactor (Make: L&T, Cat. No. - AUMC2002501 or equivalent model of Legrand / Seimens), 1 No. 16-32A SP MCB ('C'- Curve , Make - L&T / Legrand / Seimens) on 12 way Double door SPN MCB DB enclosure (Make - L&T / Legrand / Seimens) after cutting the wall and mending good the damages to original finish. incl. necessary inter connection with suitable size copper wire as per direction of EIC. |
| 33 | TERMS & CONDITIONS |
| 34 | (i) Rate should be quoted inclusive of all applicable taxes and Duties etc including GST.(ii) The Agency must procure the materials for the Manufacturer / OEM or from their authorized sales channel, so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them.iii) Documents that authenticate such procurement from the manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution of work / submission of bill.iv) If any refurbished material is supplied and installed, penal action will be taken as per existing rules. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 10 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender