Tender For Creation Of 100 Kva Sub-Station At Hafiz Mohalla/Nengro Mohalla Prichoo, Under Workcode Pddss2627100239 - Creation Of Sub-Stations, Under Ut Capex For The Year 2025-26.
Tender Value
8.20 Lakhs
Estimated cost
Bid Submission
31 Aug 2026
8 days left
EMD
16400
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pulwama → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Creation Of 100 Kva Sub-Station At Hafiz Mohalla/Nengro Mohalla Prichoo, Under Workcode Pddss2627100239 - Creation Of Sub-Stations, Under Ut Capex For The Year 2025-26.
BOQ
| Sl. No. | Item Description |
| 1 | Supply, Installation, Testing & Commissioning of 11/0.433kV, 3-phase, 100KVA Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, and with LV Cable Box having detachable Aluminium Gland plate. Transformer should have arrangement for vertical Take off. |
| 2 | Installation and commissioning of 9 Mtr. Long Poles (ST-410 SP33), including loading, unloading and transportation from the Divisional Store to the site of installation (Departmental Supply). |
| 3 | Supply, Installation, Testing & commissioning of 8 Mtr. Long Pole (ST-410 SP15) |
| 4 | Supply, Installation, Testing & commissioning of ACSR 0.05 Conductor (50 mm² ACSR Conductor) |
| 5 | Supply, Installation, Testing & commissioning of G I Channel/ Angle/ Flat iron for cross, braces of sizes including clamps and GI Nut Bolts with all accessories |
| 6 | Supply, Installation, Testing & commissioning of Mucki clamps/LT Shackles with insulators |
| 7 | Supply, Installation, Testing & commissioning of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 8 | Supply, Installation, Testing & commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 9 | Supply, Installation, Testing & commissioning of 11KV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
| 10 | Supply, Installation, Testing & commissioning of Gapless Surge Arrestor,9 kV, 10kA, LA with polymer housing, Stn. Type |
| 11 | Supply, Installation, Testing & commissioning of 185 mm2 Single Phase Cable, 1.1K V Grade, PVC Insulated Al. Stranded Conductor FRLS type |
| 12 | Supply, Installation, Testing & commissioning of LT Fuse set of standard make & quality. |
| 13 | Supply, Installation, Testing & commissioning of Al-Thimbles |
| 14 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover as per REC standards. |
| 15 | Earthing Complete by GI Pipe 40 mm 3 mtr long through GI Strip 25x3 mm as per REC Standards. |
| 16 | Providing of Painting of Poles 01 coat of Red Oxide and 02 coats Aluminium Paint as per standards |
| 17 | Providing of Cement bottoming of poles 1:2:4 mix as per REC standards 0.48cum /pole |
| 18 | Providing of Cement bottoming of poles 1:2:4 mix as per REC standards 0.44cum /pole |
| 19 | Providing of Danger Plates with Clamps for 9 meter HT Poles as per REC standards. |
| 20 | GEO tagged photographs of size not less than 8x6 inches on good quality photopaper (along with soft copy). |
| 21 | Supply, Installation, Testing & Commissioning of 11/0.433kV, 3-phase, 63KVA Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, and with LV Cable Box having detachable Aluminium Gland plate. Transformer should have arrangement for vertical Take off. |
| 22 | Installation and commissioning of 9 Mtr. Long Poles (ST-410 SP33), including loading, unloading and transportation from the Divisional Store to the site of installation (Departmental Supply). |
| 23 | Supply, Installation, Testing & commissioning of 8 Mtr. Long Pole (ST-410 SP15) |
| 24 | Supply, Installation, Testing & commissioning of ACSR 0.05 Conductor (50 mm² ACSR Conductor) |
| 25 | Supply, Installation, Testing & commissioning of G I Channel/ Angle/ Flat iron for cross, braces of sizes including clamps and GI Nut Bolts with all accessories |
| 26 | Supply, Installation, Testing & commissioning of Mucki clamps/LT Shackles with insulators |
| 27 | Supply, Installation, Testing & commissioning of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 28 | Supply, Installation, Testing & commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 29 | Supply, Installation, Testing & commissioning of 11KV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
| 30 | Supply, Installation, Testing & commissioning of Gapless Surge Arrestor,9 kV, 10kA, LA with polymer housing, Stn. Type |
| 31 | Supply, Installation, Testing & commissioning of 185 mm2 Single Phase Cable, 1.1K V Grade, PVC Insulated Al. Stranded Conductor FRLS type |
| 32 | Supply, Installation, Testing & commissioning of LT Fuse set of standard make & quality. |
| 33 | Supply, Installation, Testing & commissioning of Al-Thimbles |
| 34 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover as per REC standards. |
| 35 | Earthing Complete by GI Pipe 40 mm 3 mtr long through GI Strip 25x3 mm as per REC Standards. |
| 36 | Providing of Painting of Poles 01 coat of Red Oxide and 02 coats Aluminium Paint as per standards |
| 37 | Providing of Cement bottoming of poles 1:2:4 mix as per REC standards 0.48cum /pole |
| 38 | Providing of Cement bottoming of poles 1:2:4 mix as per REC standards 0.44cum /pole |
| 39 | Providing of Danger Plates with Clamps for 9 meter HT Poles as per REC standards. |
| 40 | GEO tagged photographs of size not less than 8x6 inches on good quality photopaper (along with soft copy). Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 31, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysAug 31, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer