BOQ
| Sl. No. | Item Description |
| 1 | Supply & fixing of 9 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 155 mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. (561 Nos. - 265 Nos. = 296 Nos.)UPPWD 2018 / Sl. No. 645 |
| 2 | Supplying, installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4- 5, Driver efficiency >85%, THD < 10% as per IEC 61000-3-2, P. F.20.95, IP- 66,IK-10, CRI >80, under voltage and over voltage protection, EMI- EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), |
| 3 | SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 Im/Watt output. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).DSR-2025 Vol-II/Sl. No. 8.14.19 Pg. No. 13 |
| 4 | 200 Watt |
| 5 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.UPPWD 2018 / Sl. No. 501 |
| 6 | 16 sq. mm 4 core (i) Deduct Rate for cables is passed through DWC Pipe(343.00-170.00 = ) |
| 7 | 35 sq. mm 3-1/2 core (L) |
| 8 | Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer Incharge.UPPWD 2018 / Sl. No. 503 |
| 9 | 16sq. mm 4 core (i) |
| 10 | 35 sq. mm 3-1/2 core (L) |
| 11 | Supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge.UPPWD 2018 / Sl. No. 504 |
| 12 | 25 sq. mm |
| 13 | 16 sq. mm |
| 14 | 35 sq. mm |
| 15 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part Il complete with fitting and cutting, jointing etc.direct in ground (75 cm _ below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. DSR (E&M) 2025 / Sl. No. 15.16.1 |
| 16 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 17 | Numbering of poles with combination of yellow and black colour paint etc. complete in all respect as per direction of the Engineer-Incharge at SITE SOR 42/ FTS No. 128181 |
| 18 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.DSR-2025 /Sl. No. 5.2 Pg. No. 30 |
| 19 | S/L of 90 mm dia DWC pipe for drawing of power cable across the road by drilling of 120 mm dia at 1 mtr. below the road level thereby doing the work of providing DWC pipe by trenchless method GNIDA Approved Rate 2024 / Sl. No. 15 |
| 20 | S/F of G.I. pipe 100 mm dia 'B' class ZINDAL / TATA make including required material T&P etc. complete in all respect as per direction of the Engineer-Incharge at SITE SOR 37/ FTS No. 128181 |
| 21 | Supply & Fixing of MS rod for earthing with 2.5 m long, solid, 20 mm dia hot dipped galvanised MS rod buried till the top reaches 1.7 mts. below the GL complete with bolts & nuts & GI earth wire 7/14. Complete in all respect, as per direction of E-I/C.GNIDA Approved Rate 2024 / Sl. No. 41 |
| 22 | Supply & Drawing of 3 x 2.5 Sqmm of FRLS / HFFR PVC insulated copper concutor, single core cable in the existing surface / recessed steel / PVC conduit as required. Complete in all respect, as per direction of E-I/C.DSR 2025 / Sl. No. 1.17.12 |
| 23 | Providing & Fixing 25 mm x 5 mm G.I. strip on surface or in recess for connection etc. as required complete in all respect.DSR-2025 /Sl. No. 5.15 Pg. No. 31 |
| 24 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. 40 A TPN (F-II)UPPWD 2018 / Sl. No. 807 |
| 25 | Dismantling / Loading / Unloading of Street Light pole & street light Fitting standard/ strut Stacking side to store (Contractor & GNIDA) embedded in cement concrete foundation etc. as required.DSR 2018 / Sl. No. 13.42 |
| 26 | Pole Erection and Foundation Charges for by cutting existing surface for making of suitable pit of size 450 x 450 x 1700 mm construction RCC foundation grade for grouting the pole with 4 Nos. of J -Bolt (24 mm x 700mm, 100 mm thread 100 mm L with 2 Nos. & washer per bolt) and fitting with RCC mix of 1:2:4 (Cement coarse sand: grit) M-25 grade for proper grouting of pole along with suitable size 12 mm steel cage grouted I the ground inclusive of all material labour. T & P etc. water cuing up to 7 days for completion of work as per direction of I/I-c at siteAOR |
| 27 | Fixing of Street Light FittingUPPWD 2018 / Sl. No. 1425 (A) |
| 28 | Labour Cess and GST will be paid extra as per govt. orders Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender