Public Administrative Department Local Bodies Closing in 1 days TDR #57070084

Tender For Providing Lights At Various Vending Sites In Chandigarh.

Issued by Local Bodies · Chandigarh, Chandigarh
Tender Value
27.50 Lakhs
Estimated cost
Bid Submission
26 Aug 2026
1 days left
EMD
55009
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Providing Lights At Various Vending Sites In Chandigarh.

BOQ

Name of Work:- Providing Lights at various Vending Sites in Chandigarh.
Sl. No. Item Description
1Supply & erection of steel tubular 9 mtr pole 410 SP-27 conforming to IS-2713-1980, (Part-I & II) having overall length of 9 Meter and welded in 3 steps and having approximate Wt. 108 Kgs. With the following specifications: -a) The poll shall have cross-sectional length of 5.00, 2.00, 2.00 Mtrs.b) The outside dia and thickness shall be114.3x5.40mm, 88.9x4.85mm and 76.1x3.25mm.c) The pole shall be erected 1.50mtrs. Below the ground level in 8” internal readymade RCC muff.d) The gap between the pole and the muff shall be filled with the cement concrete 1:2:4. The cost includes all labour and material including carriage to the site of work. e) The bottom portion of the pole shall be painted with two coats of black paint after removing the dust/rust. The work shall be executed to the entire satisfaction of Engineer-in-Charge.
2S/Erection of steel tubular pole 410 SP-6 conforming to IS-2713-1980, (Part 1 & II) having over all length of 7.5 Mtr and welded in 3 steps and having approximate Wt.92 Kgs with the followings:- a) The poll shall have cross-sectional length of 4.50,1.5,1.5 Mtrs.,b) The out side dia and thickness shall be 114.3x5.40mm, 88.9x4.85mm and 76.1x3.25mm.c) The pole shall be erected 1.25mtrs. below the ground level in 8” internal ready made RCC muff. The gap between the pole and the muff shall be filled with the cement concrete 1:2:4.d) The cost includes all labour and material including carriage to the site of work. e) The bottom portion of the pole shall be painted with two coats of black paint after removing the dust/rust.The work shall be executed to the entire satisfaction of Engineer-in-Charge.
3Supply and Erection of 2.5” dia. GI Pipe pole 4.5 Mtrs long.Supply, Fabrication & erection of 2.5” dia G.I. pipe pole having length 4.5 long, B class (medium) ISI marked. The pole shall be erected 3’ below ground level in 8” dia. RCC muff ready made. The gap between the pole and muff shall be filled with cement concrete in ratio of 1:2:4 and making required no. of holes in the pole including carriage of pole to the site of work including all labour and material required to complete the job including suitable size of nipple welded with the pipe. The work shall be executed to the entire satisfaction of Engineer-in-Charge.
4S/E of Collars of CC Collars including following:- a) The box shall be enclosed in a cement collar made form cement concrete 1:2:4 with outside dia. 16”.b) The collar shall be embedded in the ground up to 6” shall stand 9” above ground shall have housed 10” high SMC Box and 6” top over the box.c) The collar shall be provided with 2 PVC Pipes of 40mm dia. and 45cm long to facilitate entry of cables in the Jn.Box.d)n The collar shall be plastered properly finished, curing and painted with 2 coats of snowcem of superior quality. (e) Providing and Fing Junction box of size 250x200x100mm inside dimensions of thermosetting sheet moulding compound material of robust construction with double hinge, side clamp locking arrangement, provision for MCB/Kit installatin provision alongwith connector strip of 30 amps rating suitable for minimum 4x16 sq.mm aluminium cable termination. The junction box should have two numbers PVC Glands with sufficient space for cable entry and loose wires complete in all respect to the best satisfaction of Engg.in.charge.
5Supply and Erection of Angle Iron of bracket of 3' long made out of Angle Iron of size 50x5mm, 1mtr long mounted on 3” to 5'' dia G.I. Pipe canopy (0.45 mtr long to support the bracket to be fitted on 9 to 12 mtr. Pole & top end of canopy shall be covered with 14 GMS sheet to avoid entry of rainwater in Steel Tubular Pole. Thecomplete in all respect with suitable clump and nuts/bolts to the entire satisfaction of the Engineer-in-charge.
6G.I. Earth pipe electrode with salt/ Charcoal:-Supply and laying of earth electrode made out of ISI marked 'B' class G.I. pipe 4.5 Mtr. long 40 mm dia including accessories. GI pipe electrode shall be cut tapered at the bottom, and provided with holes of 12mm dia, drilled not less than 7.5 cm from each other upto 2 Mtr. of length from bottom. The earth electode shall be laid in ground after boring as per CPWD specifications complete in all respect and to the entire satisfaction of the engineer-in-charge.
7P/F 6 SWG GI wire: Providing & fixing earth connection from earth electrode with 6 SWG dia G.I. wire to pole
8Dismantling of old broken CC Collar and junction box and Digging of Existing Loops Upto 1 Mtr Below in Kutcha/Pakka Floor, Cutting, Dressing and Reconnections with Thimbles /Nuts &Bolts Complete in the Jn.Box And Lifting Any Malba From Site And Dumping at the C&D plant Industrial Area Phase-I.
9Dismantling & Re-Erection of existing Steel tubular pole 7.5/9 Mtr. Long along with Jn. Box, fittings with Wire & bracket etc. & other material complete in all respect. The pole shall be erected 1.5 Mtr. below the ground level in 8” internal dia ready made RCC muff. The gap between the pole and the muff shall be filled with the cement concrete 1:2:4. The cost includes all labour and material. The bottom portion upto 1.25 Mtr. of the pole should be painted with two coats of black bituminous paint after removing the dust. The job shall be completed to the entire satisfaction of Engineer-in-Charge.
10Dismantling & Re-Erection of G.I. Pipe Pole 4.5 Mtr. Long alongwith Globe fitting etc. & other material complete in all respect. The pole shall be erected 1.5 Mtr. below the ground level in 8” internal dia ready made RCC muff. The gap between the pole and the muff shall be filled with the cement concrete 1:2:4. The cost includes all labour and material. The bottom portion upto 1.25 Mtr. of the pole should be painted with two coats of black bituminous paint after removing the dust. The job shall be completed to the entire satisfaction of Engineer-in-Charge.
11Supply & Laying of flexible PVC insulated FR PVC sheathed 3 Core 1.5 mm2 Copper Cable conforming to IS -694:2010 of make KEI,Havells ,Cirtina / finolex , Polycab within the9 mtr Steel tubular / Octagonal pole and within bracket fitted on pole.The job include the cost of other petty material required to complete the job to the entire satisfaction of engineer –in – change precautions of the work.
12Supply & Laying of flexible PVC insulated FR PVC sheathed 3 Core 2.5 mm2 Copper Cable conforming to IS -694:2010 of make KEI,Havells ,Cirtina / finolex , Polycab within the9 mtr Steel tubular / Octagonal pole and within bracket fitted on pole.The job include the cost of other petty material required to complete the job to the entire satisfaction of engineer –in – change precautions of the work.
13Supply & laying of ISI marked 4 core 16 mm sq PVC INSULATED Aluminium armoured cable loose in trench/ pipe:-Supply & laying of ISI marked 4 core 16 mm sq Aluminum conductor armoured cable of make Havell's/ Finolex/ Ecko/ Lapp/ Polycab/ KEI conforming IS:1554 (Pt.1) amended. The cable shall be laid as per DSR Code 7.5.1 . The job included all Connections, Commissioning and testing of phase. Supply complete in all respective to the entire satisfaction of the Engineer in charge.
14Supply & Laying of DWC pipe 50/63mm with hand bockey:-Supply and laying of 50/63 mm (I/D& O/D) Double Wall Corrugated (DWC) High Density Polyethylene pipe (HDPE Density 240 to 958 KG/Cm3) having corrugation on the outer wall and plain surface inner wall with average wall thickness for outer layer as 1.1+0.1mm of Make Duraline/Rex/Zen duct/Gemini. The pipe should be laid 3 feet below ground/road level with hand bockey without cutting of road for laying cables etc. including cost of digging and refilling of pits complete in all respects to the entire satisfaction of Engineer-in-Charge.
15Supply & Laying of DWC pipe 50/63mm with out hand bockey:-Supply and laying of 50/63 mm (I/D& O/D) Double Wall Corrugated (DWC) High Density Polyethylene pipe (HDPE Density 240 to 958 KG/Cm3) having corrugation on the outer wall and plain surface inner wall with average wall thickness for outer layer as 1.1+0.1mmof Make Duraline/Rex/Zen duct /Gemini. The pipe should be laid 75 cm below ground/road level by digging the ground or cutting the road/paver blocks upto required level & laying of DWC pipe for laying L.T. (up to 1.1 KV grade) cables etc. including cost of digging and refilling of pits/Trench complete in all respects to the entire satisfaction of Engineer-in-Charge of work.
16Painting and Numbering of 7.5/10 mtr long existing street light pole above ground level with two coats of Al. paint of superior quality alongwith single/ double/ triple arm/ round bracket. The pole surface should be cleaned well by removing dust/rust & other depositions .The job includes cost of labour required for holding the ladder and controlling the traffic while using crane/ boom.Numbering on the pole be done on two sides on each pole by painting 4\\" dia round with yellow paint and make number with black paint. The Cement collar around the pole should be painted with two coats of good quality white colored snowcem. The job includes the cost of paint of existing Junction box cover with Red paint and any other petty material require to complete the job to the entire satisfaction of Engineer-in-charge
17PAINTING & NUMBERING OF POLES 4.5 Mtr. LONG Painting of poles above ground level with two coats of Al paint of Nerolec/Asian/ICI duly approved by the Engineer-in-charge. The pole surface should be cleaned well by removing dust/rust & other depositions Numbering on the pole be done on two sides on each pole with yellow and the number should be written in black letters of 3” in length.The Cement collar around the pole should be painted with two coats of good quality white colored snowcem. The job includes the cost of paint of existing Junction box cover with Red paint and any other petty material require to complete the job to the entire satisfaction of Engineer-in-charge
18Supplying and fixing of following size of PVC conduit alongwith accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. Size 25mm
19Supply & Erection of Three Phase Sensor based Timer and Contactor assembled in 22 gauge CRCA sheet enclosure duly powder coated with the following accessories (Three Phase) of Make Amsons /L&T/Scheinder or equivalent as approved by the Engineer-in-Charge. It shall conform to latest relevant IS Code:-1. It shall have 3 contactors of capacity 40 Amp. Each of made BCH, Legrand, L&T or Siemons. The contractor should be of AC-3 duty 2 pole, 220/240 V coil Voltage. 2. It shall have Auto/Manual switch, light activated switching system with allied accessories as required. 3. It shall have kit-kat fuse unit of 40 Amp capacity. The fuse unit shall conform to latest relevant IS code for protection of timers, bakelite sheet & other components as per requirement as site. 4. It shall be housed in a powder coated 22 gauge M.S sheet cabinet fo its protection. 5.The device shall be provided/fixed in the existing pedestal box in such a way so that it operates at correct time i.e. at rising/setting of Sun. The Sensor shall be included time watch to operate as required. The work shall be executed to the entire satisfaction of Engineer-in-charge. Warranty:- IT SHOULD STAND WARRANTY FOR ONE YEAR TOWARDS ANY MANUFACTURING DEFECTS.
20Supply of Reducer for 25 Watt, 40 Watt, 45 Watt, 80 Watt, 90 Watt, 120 Watt for Street Lights to install the existing Steel tubular Pole/ MS Pole 7.5 Mtrs. to 12 Mtrs. Pole. The work shall be executed to the entire satisfaction of Engineer-in-Charge.
21Minor Repair of CC Collar: Minor Repair of Cemented Bollard/ CC Collar and all the necessary items for repair i.e. sand and cement and curing of CC Collar after repair complete in all respects to the entire satisfaction of Engineer-in-Charge.
22Dismantling of existing G.I. Pipe Pole 4.5 Mtr. Long along with Defective fitting with wire & CC Collar etc. & other material complete in all respect to the satisfaction of Engineer-in-Charge. The contractor shall hand over the dismantled material to the J.E. In-charge at central store in proper form duly accounted.
23Dismantling of existing Steel tubular pole 7.5/9 Mtr. Long along with Jn. Box, fittings with Wire & bracket etc. & other material complete in all respect to the satisfaction of Engineer-in-Charge. The contractor shall hand over the dismantled material to the J.E. In-charge at central store in proper form duly accounted.The poles to be dismantled at multiple locations in the area of sub division will be dismantled throughout the year, whenever online complaint will be rceived. Nothing extra will be paid for this.
24S/E of 32mm dia X1m Long GI Pipe (Medium Class) Bracket for mounting of LED Street Lighting/Fitting on wall including bending the pipe of suitable size to the required shape (90 to 105 deg), 2 Nos M.S. Clamps with Nut, Bolts and Washer. GI Coating/Painting the flat iron with primer and finish paint as per relevant tender specifications
25SUPPLY & ERECTION OF G.I.PIPE BRACKET 5 FEET O/H SINGLE ARM:-Supply and Erection of 5’ over hang bracket S/A made of G.I. pipe medium class ISI Marked with the following specifications of Make Tata/ Jindal. The work shall be executed to the entire satisfaction of engineer-in-charge.1. The bracket shall be made by G.I. pipe of 2” dia with an angle of inclination of 105 degrees to the vertical.2. The 2” dia G.I. pipe shall be welded to 3” dia G.I. pipe canopy at a distance of 2” from top end & top end of canopy shall be closed with 14 GMS sheet to avoid entry of rainwater in S.T. poles.3. The bracket shall be slipped over the top section of the steel tubular pole and fixed with 2 Nos. of ½” dia nuts and bolts suitable to hold the pipe absolutely tight in positions.4. Triangular 14 GMS sheet pieces of 6” diagonal shall be welded between two pipe.5. The sample of bracket shall be got approved from the Engineer in Charge before installation at the workshop where these are fabricated.
26Supply and laying of insulated 2 core x 10mm2 aluminium multi conductor twin core flat unarmoured cable to fixed on the suitable clamps and nuts /bolts etc make finolex/ lapp/ polycab/ havell's or its equivalent of ISI marked. The work shall be executed to the entire satisfaction of engineer-in-charge.
27Providing & Fixing Cable Junction box of size 250X200X100MM complete in all respect. The job included fixing of Junction box on the walll with all petty material as required. The work shall be executed to the entire satisfaction of Engineer-in-Charge.
28Outdoor type M.S. Cubical Pedestal : S&E of Outdoor type BOTH SIDE OPEN ABLE M.S. Cubical Pedestal of size 1200mmx 900mm x350mm fabricated from 16 G.M.S. sheet welded on M.S. angle iron frame of size 50mmx 50mm x6mm with 4 Nos. legs of angle iron of same size each of length 600mm with M.S. sheet of size 100mmx100mmx6mm thick at the bottom of the legs. The front side of the pedestal should be openable with hiunged door provided with Godrej type locking arrangements. A 'U' type support made from M.S. sheet of 16 G having width 75mmx6mm be welded vertically in the inner side of the door to avoid entry of water. The door of the pedestal should be provided with rubber gasket to avoid entry of other insects etc. The top of the pedestal shall be covered with canopy made out of 16 G M.S. sheet projected outside to avoid entry of water. M.S. sheet of 16 G thickness and 1200mm x 150mm size be fixed at the front to cover the entry of cables. Four No. supporting members each of size 50mmx6mm thick according to cubical size shall be welded for mounting switcher gear i.e. ICTPN,BBC, Timer and energy meter etc. The Pedestal shall be painted with two coats of P.O. red paint after applying one coat of red oxide. The legs of the pedestal shall be embedded in the 1:2:4 R C.C. mixture by digging 1½' deep as required. The letter 'M.C.C.' in 4\\" size shall be written on the front door of the Pedestal. The job also includes Supply & erection one No. wooden plank/ board of size 1'-6\\" x 1'-6\\" and 25mm thick suitable for fixing energy meter including cost of screws, nuts & bolts in cubical pedestal complete in all respects. The pedestal will be housed on RCC Foundation platform of size 900 mm deep (450 mm underground and 450 mm above ground x 910 mm long x 360 mm wide including sufficient number of entries for cable with DWC pipe The work shall be executed to the entire satisfaction of Engineer-in-Charge.
29Supply & Erection of Three Phase Aluminum Bus BarSupply & Erection of Single Phase Aluminum Bus Bar of size 600mmx40mmx4mm with L type fuse unit covered with the heat shrink insulation sheet to be fixed on Porcelein insulators in the existing pedestal with required material. The fuse links should be equal to the number of out going circuits. The work shall be executed to the entire satisfaction of Engineer-in-Charge.
30Providing and fixing 100 A 30 KA 4 POLE rating and breaking capacity MCCB withthermomagnetic release and terminal spreaders in existing cubicle panel boardincluding drilling holes in cubicle panel, making connections, etc. as required.
31Painting of pedestal size 1200x900x350mm/900x600x350mm with P.O. red paint complete in all respect and bonding to the existing earth etc. and platform of cement concrete 1:2:4 around the pillar box of size 3’x2’x0’-4”. The work shall be executed to the entire satisfaction of Engineer-in-Charge.
32Erection of LED Street Light/ Flood Light/ Globe Light on 4.5/7.5/9 mtr pole complete in all respect to the entire satisfaction of Engineer-in-charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57070084
AUTHORITY Local Bodies
TENDER VALUE 27.50 Lakhs
LAST DATE 26-08-2026
Authority
Authority Name Municipal Corporation
Work Description Tender for Providing Lights At Various Vending Sites In Chandigarh.
Basic Detail
Tender No 146/E/MCC/2026
Bidding Type Tender
Location
City Chandigarh
State Chandigarh
Key Dates
Publish Date 18 Aug 2026
Submission Date 26 Aug 2026
Open Date 26 Aug 2026
Finance
Tender Value 27.50 Lakhs
Tender Fee 3000
EMD 55009
Exemption Not Available
Document List
6ee4534a-eb51-4579-a2f4-994cc805f3dc.html
BOQ_116427.xls
Tendernotice_1 (18).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 26, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Aug 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
html

6ee4534a-eb51-4579-a2f4-994cc805f3dc.html

xls

BOQ_116427.xls

pdf

Tendernotice_1 (18).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender