Tender For Rate Contract For Total Hip Arthoplasty Impants At Jhalawar Hospital And Medical College Jhalawar
Tender Overview
Project Description
Tender for Rate Contract For Total Hip Arthoplasty Impants At Jhalawar Hospital And Medical College Jhalawar , Cemented Thr Sterile With All Instrument Set , Cemented Femoral Stem Highly Polished Double Taper S.S. With 12/14 Neck Taper, With Collerless Design, All Sizes Sterile , The Cemented Cup Should Have Ultra-High Molecular Weight Polyethylene 10 Degree Posterior Superior Lip With Pmma Cement Spacer Easily Identifiable The Cup Position On An X-Ray. Cup Should Be Available In All Sizes. , Metal Femoral Head Ss Should Have Dia.28Mm/32Mm/36Mm In All Neck Length Sizes Sterile , Cement Restrictor/Bone Plug Of Uhmwpe Sterile , Void Centralizer Uhmwpe Sterile All Sizes. , Un-Cemented Thr (Metal On Poly With Xlpe[Cross Link] Poly) Same Make Sterile With All Instrument Set , The Femoral Stem Should Have Fully Ha Coating Of 50-Micron Thick Body, With 12/14 Neck Taper, Made Up Of Ti6al4v Material Sterile. , The Acetabular Shell Should Utilize The Inner Change Locking Mechanism. The Acetabular Shell Should Be Porus Coated. The Acetabular Shell Should Feature Independent Locking Mechanisms For Cross Link Polyethylene Liners. The Acetabular Shell Sizes Should Come In Sizes From 44 To 62 Mm, All Sizes Sterile. , The Xlpe(Cross Link) Poly Liner Should Have 10-Degree Posterior Superior Lip. The Xlpe Poly Liner Should Be Compatible To Accommodate 28Mm, 32Mm, And 36Mm Heads, All Sizes Sterile. , Metal Femoral Head Cocr Should Have Dia. 28Mm/32Mm/36Mm In All Neck Length Sizes Sterile , Cancellous Low Profile Screw Titanium 6.5Mm In Diameter, All Sizes Sterile , Un-Cemented Thr (Ceramic On Poly [With Vitamin - E Poly]) Same Make Sterile With All Instrument Set , The Femoral Stem Should Have Morphometric Wedge Geometry And Ha Coating, Ha Coating Of 50-Micron Thick, Proximal Body Should Be Having Circumferentially Dual Coating, Ha On Plasma Sprayed/Porous Coating, With 12/14 Neck Taper, Made Up Of Ti6al4v Material Sterile , The Acetabular Shell Should Utilize The Inner Change Locking Mechanism. The Acetabular Shell Should Be Porus Coated. The Acetabular Shell Should Feature Independent Locking Mechanisms For Vitamin - E Polyethylene Liners. The Acetabular Shell Sizes Should Come In Sizes From 44 To 62 Mm, All Sizes Sterile. , The Vitamin - E Poly Liner Should Have 10-Degree Posterior Superior Lip. The Vitamin - E Poly Liner Should Be Compatible To Accommodate 28Mm, 32Mm, And 36Mm Heads, All Sizes Sterile. , Ceramic Femoral Head Should Have Dia.28Mm/32Mm/36Mm In All Neck Length Sizes Sterile , Cancellous Low Profile Screw Titanium 6.5Mm In Diameter, All Sizes Sterile , Hybrid Thr Sterile With All Instrument Set , Cemented Femoral Stem Highly Polished Double Taper S.S. With 12/14 Neck Taper, With Collerless Design, All Sizes Sterile , The Acetabular Shell Should Utilize The Inner Change Locking Mechanism. The Acetabular Shell Should Be Porus Coated. The Acetabular Shell Should Feature Independent Locking Mechanisms For Xlpe Polyethylene Liners. The Acetabular Shell Sizes Should Come In Sizes From 44 To 62 Mm, All Sizes Sterile. , The Xlpe Poly Should Have 10-Degree Posterior Superior Lip. The Xlpe Poly Should Be Compatible To Accommodate 28Mm, 32Mm, And 36Mm Heads, All Sizes Sterile. , Metal Femoral Head Cocr 28Mm/32Mm/36Mm All Neck Length Sizes Sterile , Cancellous Low Profile Screw Titanium 6.5Mm In Diameter, All Sizes Sterile , Cement Restrictor/Bone Plug Of Uhmwpe Sterile , Void Centralizer Uhmwpe Sterile All Sizes. , Reverse Hybrid Thr Sterile , The Femoral Stem Should Have Fully Ha Coating Of 50-Micron Thick Body, With 12/14 Neck Taper, Made Up Of Ti6al4v Material Sterile. , The Cemented Cup Should Have Ultra-High Molecular Weight Polyethylene 10 Degree Posterior Superior Lip With Pmma Cement Spacer Easily Identifiable The Cup Position On An X-Ray. Cup Should Be Available In All Sizes. , Metal Femoral Head Cocr Should Have Dia. 28Mm/32Mm/36Mm In All Neck Length Sizes Sterile , Calcar Cemented Femoral Stem In Different Size & Length With Stem Block As Spacer For Calcar With Two Screw For Stem Flange For Thr, Sterile , Calcar Cemented Femoral Stem In Ss In Different Size & Length With Flange For Stem Block/Spacer For Calcar With Screw Option In Stem With 12/14 Neck Taper, Sterile , Calcar Stem Block As Spacer In Ss In 10Mm, 20Mm & 30Mm Thickness/ Width Of The Block For Calcar With Two Screw For Calcar Cemented Stem Flange For Thr Sterile , Dual Mobility Un-Cemented Thr With Cocr Liner Of Same Make As Primary With All Instrument Set , The Femoral Stem Should Have Morphometric Wedge Geometry And Ha Coating, Ha Coating Of 50-Micron Thick, Proximal Body Should Be Having Circumferentially Dual Coating, Ha On Plasma Sprayed/Porous Coating, With 12/14 Neck Taper, Made Up Of Ti6al4v Material Sterile , The Acetabular Shell Should Provide Dual Mobility Cup Which Composed Of Cocr Metal Liner & Vitamin - E Poly Which Support 22- And 28-Mm Femoral Metal Head. The Acetabular Shell Sizes Should Come In Sizes From 44 To 62 Mm, Made Up Of (Titanium) Ti6al4v Material, All Sizes Sterile. , The Dual Mobility Cocr Metal Liner Of Different Sizes To Be Fit In The Above (Titanium)Ti6al4v Acetabular Shell & Should Also Accomodate Dual Mobility Vitamin - E Poly Liner Which Support 22- And 28-Mm Femoral Metal Head. All Sizes Sterile. , The Dual Mobility Vitamin - E Poly Liner(Which Support 22- And 28-Mm Femoral Metal Head) Of Different Sizes To Be Fit In The Above Dual Mobility Cocr Metal Liner Of Different All Sizes Sterile , Metal Femoral Head Cocr 22Mm/28Mm All Sizes Sterile , Cancellous Low Profile Screw Titanium 6.5Mm In Diameter, All Sizes Sterile , Dual Mobility Cemented Thr With Cemented Stem & Cemented Metal Shell Cup For Acetabular Highly Mirror Polished Inside To Accommodate Xlpe Poly Liner(Which Support 22- And 28-Mm Femoral Metal Head) Of Different All Sizes Sterile. , Cemented Femoral Stem Highly Polished Double Taper S.S. With 12/14 Neck Taper, With Collerless Design, All Sizes Sterile , The Dual Mobility Cemented Metal Shell Acetabular Cup Should Provide Highly Mirror Polished Surface Inside Which Composed Of Vitamin - E Poly Liner Which Support 22- And 28-Mm Femoral Metal Head. All Sizes Sterile. , The Dual Mobility Vitamin - E Poly Liner(Which Support 22- And 28-Mm Femoral Metal Head) Of Different Sizes To Be Fit In The Above Dual Mobility Cocr Metal Liner Of Different All Sizes Sterile , Metal Femoral Head Cocr 22Mm/28Mm All Sizes Sterile , Cancellous Low Profile Screw Titanium 6.5Mm In Diameter, All Sizes Sterile , Cement Restrictor/Bone Plug Of Uhmwpe Sterile , Void Centralizer Uhmwpe Sterile All Sizes.
BOQ
| Sl. No. | Item Description |
| 1 | Cemented THR Sterile with all instrument Set |
| 2 | Cemented Femoral Stem Highly Polished Double Taper S.S. With 12/14 Neck Taper, with collerless Design, All Sizes Sterile |
| 3 | The Cemented cup should have Ultra-High Molecular Weight Polyethylene 10 degree posterior superior lip with PMMA cement spacer easily identifiable the cup position on an X-ray. Cup Should be available in all sizes. |
| 4 | Metal Femoral Head SS should have Dia.28mm/32mm/36mm in All neck length Sizes Sterile |
| 5 | Cement Restrictor/Bone Plug of UHMWPE Sterile |
| 6 | Void Centralizer UHMWPE Sterile All Sizes. |
| 7 | Un-Cemented THR (Metal On Poly with XLPE[CROSS LINK] Poly) Same Make Sterile with all instrument Set |
| 8 | The femoral Stem should have fully HA coating of 50-micron thick body, With 12/14 Neck Taper, made up of Ti6Al4V Material Sterile. |
| 9 | The Acetabular Shell should utilize the Inner change Locking Mechanism. The acetabular shell should be Porus coated. The acetabular shell should feature independent locking mechanisms for Cross Link polyethylene liners. The Acetabular Shell sizes should come in sizes from 44 to 62 mm, All Sizes Sterile. |
| 10 | The XLPE(CROSS LINK) Poly Liner should have 10-degree posterior superior lip. The XLPE Poly Liner should be compatible to accommodate 28mm, 32mm, and 36mm heads, All Sizes Sterile. |
| 11 | Metal Femoral Head CoCr should have Dia. 28mm/32mm/36mm in All neck length Sizes Sterile |
| 12 | Cancellous Low Profile Screw Titanium 6.5mm in Diameter, All Sizes Sterile |
| 13 | Un-Cemented THR (Ceramic On Poly [with Vitamin - E Poly]) Same Make Sterile with all instrument Set |
| 14 | The femoral Stem should have morphometric wedge geometry and HA coating, HA coating of 50-micron thick, Proximal body should be having circumferentially dual coating, HA on plasma sprayed/porous coating, With 12/14 Neck Taper, made up of Ti6Al4V Material Sterile |
| 15 | The Acetabular Shell should utilize the Inner change Locking Mechanism. The acetabular shell should be Porus coated. The acetabular shell should feature independent locking mechanisms for Vitamin - E Polyethylene liners. The Acetabular Shell sizes should come in sizes from 44 to 62 mm, All Sizes Sterile. |
| 16 | The Vitamin - E Poly Liner should have 10-degree posterior superior lip. The Vitamin - E Poly Liner should be compatible to accommodate 28mm, 32mm, and 36mm heads, All Sizes Sterile. |
| 17 | Ceramic Femoral Head should have Dia.28mm/32mm/36mm in All neck length Sizes Sterile |
| 18 | Cancellous Low Profile Screw Titanium 6.5mm in Diameter, All Sizes Sterile |
| 19 | Hybrid THR Sterile with all instrument Set |
| 20 | Cemented Femoral Stem Highly Polished Double Taper S.S. With 12/14 Neck Taper, with collerless Design, All Sizes Sterile |
| 21 | The Acetabular Shell should utilize the Inner change Locking Mechanism. The acetabular shell should be Porus coated. The acetabular shell should feature independent locking mechanisms for XLPE polyethylene liners. The Acetabular Shell sizes should come in sizes from 44 to 62 mm, All Sizes Sterile. |
| 22 | The XLPE Poly should have 10-degree posterior superior lip. The XLPE Poly should be compatible to accommodate 28mm, 32mm, and 36mm heads, All Sizes Sterile. |
| 23 | Metal Femoral Head CoCr 28mm/32mm/36mm All neck length Sizes Sterile |
| 24 | Cancellous Low Profile Screw Titanium 6.5mm in Diameter, All Sizes Sterile |
| 25 | Cement Restrictor/Bone Plug of UHMWPE Sterile |
| 26 | Void Centralizer UHMWPE Sterile All Sizes. |
| 27 | Reverse Hybrid THR Sterile |
| 28 | The femoral Stem should have fully HA coating of 50-micron thick body, With 12/14 Neck Taper, made up of Ti6Al4V Material Sterile. |
| 29 | The Cemented cup should have Ultra-High Molecular Weight Polyethylene 10 degree posterior superior lip with PMMA cement spacer easily identifiable the cup position on an X-ray. Cup Should be available in all sizes. |
| 30 | Metal Femoral Head CoCr should have Dia. 28mm/32mm/36mm in All neck length Sizes Sterile |
| 31 | Calcar Cemented Femoral Stem in different size & Length with Stem Block as Spacer for Calcar with two screw for Stem Flange for THR, Sterile |
| 32 | Calcar Cemented Femoral Stem in SS in different size & Length with Flange for Stem Block/Spacer for Calcar with screw option in Stem With 12/14 Neck Taper, Sterile |
| 33 | Calcar Stem Block as Spacer in SS in 10mm, 20mm & 30mm thickness/ width of the Block for Calcar with two screw for Calcar Cemented Stem Flange for THR Sterile |
| 34 | Dual Mobility Un-Cemented THR with CoCr Liner of same make as primary with all instrument set |
| 35 | The femoral Stem should have morphometric wedge geometry and HA coating, HA coating of 50-micron thick, Proximal body should be having circumferentially dual coating, HA on plasma sprayed/porous coating, With 12/14 Neck Taper, made up of Ti6Al4V Material Sterile |
| 36 | The Acetabular Shell should provide Dual Mobility Cup which composed of CoCr Metal Liner & Vitamin - E Poly which support 22- and 28-mm femoral metal head. The Acetabular Shell sizes should come in sizes from 44 to 62 mm, made up of (Titanium) Ti6Al4V Material, All Sizes Sterile. |
| 37 | The Dual Mobility CoCr Metal Liner of different sizes to be fit in the above (Titanium)Ti6Al4V Acetabular Shell & should also accomodate Dual Mobility Vitamin - E Poly Liner which support 22- and 28-mm femoral metal head. All Sizes Sterile. |
| 38 | The Dual Mobility Vitamin - E Poly Liner(which support 22- and 28-mm femoral metal head) of different sizes to be fit in the above Dual Mobility CoCr Metal Liner of different All sizes Sterile |
| 39 | Metal Femoral Head CoCr 22mm/28mm All Sizes Sterile |
| 40 | Cancellous Low Profile Screw Titanium 6.5mm in Diameter, All Sizes Sterile |
| 41 | Dual Mobility Cemented THR with Cemented Stem & Cemented Metal Shell Cup for Acetabular Highly mirror polished inside to accommodate XLPE Poly Liner(which support 22- and 28-mm femoral metal head) of different All sizes Sterile. |
| 42 | Cemented Femoral Stem Highly Polished Double Taper S.S. With 12/14 Neck Taper, with collerless Design, All Sizes Sterile |
| 43 | The Dual Mobility Cemented Metal Shell Acetabular Cup should provide highly mirror polished surface inside which composed of Vitamin - E Poly Liner which support 22- and 28-mm femoral metal head. All Sizes Sterile. |
| 44 | The Dual Mobility Vitamin - E Poly Liner(which support 22- and 28-mm femoral metal head) of different sizes to be fit in the above Dual Mobility CoCr Metal Liner of different All sizes Sterile |
| 45 | Metal Femoral Head CoCr 22mm/28mm All Sizes Sterile |
| 46 | Cancellous Low Profile Screw Titanium 6.5mm in Diameter, All Sizes Sterile |
| 47 | Cement Restrictor/Bone Plug of UHMWPE Sterile |
| 48 | Void Centralizer UHMWPE Sterile All Sizes. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender